Coronary wall MR Imaging in patients with rapid heart rates: a feasibility study of black-blood steady-state free precession (SSFP)

verfasst von: Kai Lin, Xiaoming Bi, Kirsi Taimen, Sven Zuehlsdorff, Biao Lu, James Carr, Debiao Li

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

We assessed the hypothesis that black-blood steady-state free precession (SSFP) would provide coronary wall images comparable to images from TSE and have better performance than TSE under conditions of fast heart rate. With IRB approval, thirty participants without a history of coronary artery disease (19 men, 11 women, 26–83 y/o) were scanned with a 1.5 T MR scanner. Cross-sectional black-blood images of the proximal portions of coronary arteries were acquired with a two-dimensional (2D), double inversion recovery (DIR) prepared TSE sequence and a 2D DIR SSFP sequence on the same planes. Image quality (ranked with a 4-point system, scored from 0 to 3), vessel wall area and thickness, signal-to-noise ratio (SNR) of the wall and contrast-to-noise ratio (CNR, wall to lumen) were compared between SSFP and TSE with SPSS software (v 13.0). Totally 28 scans were completed. For SSFP and TSE, there was no difference in image quality. SSFP had a higher SNR (23.7 ± 10.1 vs. 14.4 ± 5.2, P < 0.001) and wall–lumen CNR (8.8 ± 4.5 vs. 6.7 ± 3.2, P = 0.001). Good agreements between measured wall area (r = 0.701, P < 0.001) and thickness (r = 0.560, P < 0.001) were found. For 10 participants with heart rate more than 80 beats/min, the image quality of SSFP was higher than TSE (P = 0.016). SSFP provided image quality and measurement accuracy that was comparable to TSE. With its higher performance under fast heart rate conditions, SSFP may break through the existing thresholds for heart rate and extend clinical applicability of coronary wall MR imaging to a larger population.
Literatur
1.
Zurück zum Zitat Lloyd-Jones D, Adams RJ, Brown TM et al (2010) Heart disease and stroke statistics–2010 update: a report from the American heart association. Circulation 121(7):e46–e215PubMedCrossRef Lloyd-Jones D, Adams RJ, Brown TM et al (2010) Heart disease and stroke statistics–2010 update: a report from the American heart association. Circulation 121(7):e46–e215PubMedCrossRef
2.
Zurück zum Zitat Miao C, Chen S, Macedo R et al (2009) Positive remodeling of the coronary arteries detected by magnetic resonance imaging in an asymptomatic population: MESA (multi-ethnic study of atherosclerosis). J Am Coll Cardiol 53(18):1708–1715PubMedCrossRef Miao C, Chen S, Macedo R et al (2009) Positive remodeling of the coronary arteries detected by magnetic resonance imaging in an asymptomatic population: MESA (multi-ethnic study of atherosclerosis). J Am Coll Cardiol 53(18):1708–1715PubMedCrossRef
3.
Zurück zum Zitat Berkowitz SJ, Macedo R, Malayeri AA et al (2009) Axial black blood turbo spin echo imaging of the right ventricle. Magn Reson Med 61(2):307–314PubMedCrossRef Berkowitz SJ, Macedo R, Malayeri AA et al (2009) Axial black blood turbo spin echo imaging of the right ventricle. Magn Reson Med 61(2):307–314PubMedCrossRef
4.
Zurück zum Zitat Koktzoglou I, Chung YC, Carroll TJ et al (2007) Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: initial experience. Radiology 243(1):220–228PubMedCrossRef Koktzoglou I, Chung YC, Carroll TJ et al (2007) Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: initial experience. Radiology 243(1):220–228PubMedCrossRef
5.
Zurück zum Zitat Heiberg E, Sjögren J, Ugander M et al (2010) Design and validation of segment—a freely available software for cardiovascular image analysis. BMC Medical Imaging 10:1PubMedCrossRef Heiberg E, Sjögren J, Ugander M et al (2010) Design and validation of segment—a freely available software for cardiovascular image analysis. BMC Medical Imaging 10:1PubMedCrossRef
6.
Zurück zum Zitat Bi X, Deshpande V, Simonetti O, Laub G, Li D (2005) Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5T and 3.0T. J Magn Reson Imaging 22(2):206–212PubMedCrossRef Bi X, Deshpande V, Simonetti O, Laub G, Li D (2005) Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5T and 3.0T. J Magn Reson Imaging 22(2):206–212PubMedCrossRef
7.
Zurück zum Zitat Stuber M, Botnar RM, Fischer SE et al (2002) Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48:425–429PubMedCrossRef Stuber M, Botnar RM, Fischer SE et al (2002) Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48:425–429PubMedCrossRef
8.
Zurück zum Zitat Fayad ZA, Fuster V, Fallon JT et al (2000) Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102(5):506–510PubMed Fayad ZA, Fuster V, Fallon JT et al (2000) Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102(5):506–510PubMed
9.
Zurück zum Zitat Wang Y, Vidan E, Bergman GW et al (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213(3):751–758PubMed Wang Y, Vidan E, Bergman GW et al (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213(3):751–758PubMed
10.
Zurück zum Zitat Jahnke C, Paetsch I, Achenbach S et al (2006) Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use. Radiology 239(1):71–78PubMedCrossRef Jahnke C, Paetsch I, Achenbach S et al (2006) Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use. Radiology 239(1):71–78PubMedCrossRef
11.
Zurück zum Zitat Spuentrup E, Ruebben A, Mahnken A et al (2005) Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent. Circulation 111(8):1019–1026PubMedCrossRef Spuentrup E, Ruebben A, Mahnken A et al (2005) Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent. Circulation 111(8):1019–1026PubMedCrossRef
12.
Zurück zum Zitat Botnar RM, Stuber M, Kissinger KV et al (2000) Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging. Circulation 102:2582–2587PubMed Botnar RM, Stuber M, Kissinger KV et al (2000) Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging. Circulation 102:2582–2587PubMed
13.
Zurück zum Zitat Constable RT, Gore JC (1992) The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 28:9–24PubMedCrossRef Constable RT, Gore JC (1992) The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 28:9–24PubMedCrossRef
14.
Zurück zum Zitat Listerud J, Einstein S, Outwater E, Kressel HY (1992) First principles of fast spin echo. Magn Reson Q 8:199–244PubMed Listerud J, Einstein S, Outwater E, Kressel HY (1992) First principles of fast spin echo. Magn Reson Q 8:199–244PubMed
15.
Zurück zum Zitat Deshpande VS, Shea SM, Laub G et al (2001) 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med 46(3):494–502PubMedCrossRef Deshpande VS, Shea SM, Laub G et al (2001) 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med 46(3):494–502PubMedCrossRef
16.
Zurück zum Zitat Malayeri AA, Macedo R, Li D et al (2009) Coronary vessel wall evaluation by magnetic resonance imaging in the multi-ethnic study of atherosclerosis: determinants of image quality. J Comput Assist Tomogr 33(1):1–7PubMedCrossRef Malayeri AA, Macedo R, Li D et al (2009) Coronary vessel wall evaluation by magnetic resonance imaging in the multi-ethnic study of atherosclerosis: determinants of image quality. J Comput Assist Tomogr 33(1):1–7PubMedCrossRef
17.
Zurück zum Zitat Lauenstein TC, Sharma P, Hughes T et al (2008) Evaluation of optimized inversion-recovery fat-suppression techniques for T2-weighted abdominal MR imaging. J Magn Reson Imaging 27(6):1448–1454PubMedCrossRef Lauenstein TC, Sharma P, Hughes T et al (2008) Evaluation of optimized inversion-recovery fat-suppression techniques for T2-weighted abdominal MR imaging. J Magn Reson Imaging 27(6):1448–1454PubMedCrossRef
18.
Zurück zum Zitat Udayasankar UK, Martin D, Lauenstein T et al (2008) Role of spectral presaturation attenuated inversion-recovery fat-suppressed T2-weighted MR imaging in active inflammatory bowel disease. J Magn Reson Imaging 28(5):1133–1140PubMedCrossRef Udayasankar UK, Martin D, Lauenstein T et al (2008) Role of spectral presaturation attenuated inversion-recovery fat-suppressed T2-weighted MR imaging in active inflammatory bowel disease. J Magn Reson Imaging 28(5):1133–1140PubMedCrossRef
19.
Zurück zum Zitat Fuchs F, Laub G, Othomo K (2003) TrueFISP: technical considerations and cardiovascular applications. Eur J Radiol 46:28–32PubMedCrossRef Fuchs F, Laub G, Othomo K (2003) TrueFISP: technical considerations and cardiovascular applications. Eur J Radiol 46:28–32PubMedCrossRef
20.
Zurück zum Zitat Antiga L, Wasserman BA, Steinman DA (2008) On the overestimation of early wall thickening at the carotid bulb by black blood MR IMAGING, with implications for coronary and vulnerable plaque imaging. Magn Reson Med 60:1020–1028PubMedCrossRef Antiga L, Wasserman BA, Steinman DA (2008) On the overestimation of early wall thickening at the carotid bulb by black blood MR IMAGING, with implications for coronary and vulnerable plaque imaging. Magn Reson Med 60:1020–1028PubMedCrossRef
21.
Zurück zum Zitat Hazirolan T, Gupta SN, Mohamed MA et al (2005) Reproducibility of black-blood coronary vessel wall MR imaging. J Cardiovasc Magn Reson 7(2):409–413PubMedCrossRef Hazirolan T, Gupta SN, Mohamed MA et al (2005) Reproducibility of black-blood coronary vessel wall MR imaging. J Cardiovasc Magn Reson 7(2):409–413PubMedCrossRef
Metadaten
Titel
Coronary wall MR Imaging in patients with rapid heart rates: a feasibility study of black-blood steady-state free precession (SSFP)
verfasst von
Kai Lin
Xiaoming Bi
Kirsi Taimen
Sven Zuehlsdorff
Biao Lu
James Carr
Debiao Li
Publikationsdatum
01.03.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 3/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9852-z

Weitere Artikel der Ausgabe 3/2012

The International Journal of Cardiovascular Imaging 3/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.