Excerpt

Head-neck modularity is a universally accepted option in hip arthroplasty, and it has worked extremely well in millions of cases over the years. But there is also a large body of evidence that modularity is a source of metallurgical problems including fretting corrosion and wear, producing particles that can potentially lead to clinical problems [1, 8]. …
Literatur
1.
Zurück zum Zitat Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE. Concerns with modularity in total hip arthroplasty. Clin Orthop Relat Res. 1994;298:27–36.PubMed Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE. Concerns with modularity in total hip arthroplasty. Clin Orthop Relat Res. 1994;298:27–36.PubMed
2.
Zurück zum Zitat Cook SD, Barrack RL, Baffes GC, Clemow AJ, Serekian P, Dong N, Kester MA. Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop Relat Res. 1994;298:80–88.PubMed Cook SD, Barrack RL, Baffes GC, Clemow AJ, Serekian P, Dong N, Kester MA. Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop Relat Res. 1994;298:80–88.PubMed
3.
Zurück zum Zitat Cooper HJ, DellaValle CG, Berger RA, Treteault M, Paprosky WG, Sporer SM, Jacobs JJ. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94:1655–1661.PubMed Cooper HJ, DellaValle CG, Berger RA, Treteault M, Paprosky WG, Sporer SM, Jacobs JJ. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94:1655–1661.PubMed
4.
Zurück zum Zitat Del Curto B, Diamanti MV, Dalla Pria P, Sbaiz F, Cigada A. Anodic Spark Deposition treatments to increase reliability of Ti6Al4V modular prostheses. J App Biomater Biomech. 2009;7:153–159. Del Curto B, Diamanti MV, Dalla Pria P, Sbaiz F, Cigada A. Anodic Spark Deposition treatments to increase reliability of Ti6Al4V modular prostheses. J App Biomater Biomech. 2009;7:153–159.
5.
Zurück zum Zitat Esposito CI, Wright TM, Goodman SB, Berry DJ, The Clinical, Biological and Bioengineering Study Groups from the Carl T. Brighton Workshop. What is the trouble with trunnions? Clin Orthop Relat Res. 2014;472:3652–3658.CrossRefPubMedPubMedCentral Esposito CI, Wright TM, Goodman SB, Berry DJ, The Clinical, Biological and Bioengineering Study Groups from the Carl T. Brighton Workshop. What is the trouble with trunnions? Clin Orthop Relat Res. 2014;472:3652–3658.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002;401:149–161.CrossRefPubMed Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002;401:149–161.CrossRefPubMed
7.
Zurück zum Zitat Hussenbocus S, Kosuge D, Solomon LB, Howie DW, Oskouei RH. Head-neck taper corrosion in hip arthroplasty. Bio Med Res Int. 2015;2015:758123. Hussenbocus S, Kosuge D, Solomon LB, Howie DW, Oskouei RH. Head-neck taper corrosion in hip arthroplasty. Bio Med Res Int. 2015;2015:758123.
8.
Zurück zum Zitat Jacobs JJ, Urban RM, Gilbert JL, Skipor AK, Black J, Jasty M, Galante JO. Local and distant products from modularity. Clin Orthop Relat Res. 1995;319:94–105.PubMed Jacobs JJ, Urban RM, Gilbert JL, Skipor AK, Black J, Jasty M, Galante JO. Local and distant products from modularity. Clin Orthop Relat Res. 1995;319:94–105.PubMed
9.
Zurück zum Zitat Mistry JB, Chughati M, Elmallah RK, Diedrich A, Le S, Thomas M, Mont Ma. Trunnionosis in total hip arthroplasty: A review. J Orthop Traumatol. 2016;17:1–6. Mistry JB, Chughati M, Elmallah RK, Diedrich A, Le S, Thomas M, Mont Ma. Trunnionosis in total hip arthroplasty: A review. J Orthop Traumatol. 2016;17:1–6.
10.
Zurück zum Zitat Panagiotidou A, Meswania J, Hua J, Muirhead-Allwood S, Hart A, Blunn G. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res. 2013;31:2032–2039.CrossRefPubMed Panagiotidou A, Meswania J, Hua J, Muirhead-Allwood S, Hart A, Blunn G. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res. 2013;31:2032–2039.CrossRefPubMed
11.
Zurück zum Zitat Saénz de Viteri V, Barandika MG, Ruiz de Gopegui U, Bayón R, Zubizarreta C, Fernández X, Igartua A, Agullo-Rueda F. Characterization of Ti-C-N coatings deposited on Ti6Al4V for biomedical applications. J Inorg Biochem. 2012;117:359–366. Saénz de Viteri V, Barandika MG, Ruiz de Gopegui U, Bayón R, Zubizarreta C, Fernández X, Igartua A, Agullo-Rueda F. Characterization of Ti-C-N coatings deposited on Ti6Al4V for biomedical applications. J Inorg Biochem. 2012;117:359–366.
Metadaten
Titel
CORR Insights®: Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
verfasst von
Mariano Fernandez-Fairen, MD, PhD
Publikationsdatum
14.07.2016
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 10/2016
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-016-4973-2

Weitere Artikel der Ausgabe 10/2016

Clinical Orthopaedics and Related Research® 10/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.