Skip to main content
Erschienen in: European Radiology 8/2020

Open Access 25.03.2020 | Correction

Correction to: Physical evaluation of an ultra-high-resolution CT scanner

verfasst von: Luuk J. Oostveen, Kirsten L. Boedeker, Monique Brink, Mathias Prokop, Frank de Lange, Ioannis Sechopoulos

Erschienen in: European Radiology | Ausgabe 8/2020

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise
The online version of the original article can be found at https://​doi.​org/​10.​1007/​s00330-019-06635-5
Correction to: European Radiology
The original version of this article, published on 10 February 2019, unfortunately contained a mistake. The axes of the graphs in Fig. 3 are incorrect. The correct figure is given below. Therefore, the last two sentences in “Results”, section “Noise”, should read: “The peak frequency of the HR and SHR was 0.21 lp/mm. For the NR mode and the MDCT, the peak frequencies were 0.17 lp/mm and 0.21 lp/mm, respectively.”
The X-axis of the graphs in Fig. B2 (Addendum B) has the same issue. The correct figure is given below. These changes do not affect any conclusion drawn from the results.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.
download
DOWNLOAD
print
DRUCKEN

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Metadaten
Titel
Correction to: Physical evaluation of an ultra-high-resolution CT scanner
verfasst von
Luuk J. Oostveen
Kirsten L. Boedeker
Monique Brink
Mathias Prokop
Frank de Lange
Ioannis Sechopoulos
Publikationsdatum
25.03.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 8/2020
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-06793-x

Weitere Artikel der Ausgabe 8/2020

European Radiology 8/2020 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.