Skip to main content
Erschienen in: BMC Musculoskeletal Disorders 1/2019

Open Access 01.12.2019 | Correction

Correction to: Validity and reliability of serratus anterior hand held dynamometry

verfasst von: Jos IJspeert, Hans C. J. W. Kerstens, Renske M. J. Janssen, Alexander C. H. Geurts, Nens van Alfen, Jan T. Groothuis

Erschienen in: BMC Musculoskeletal Disorders | Ausgabe 1/2019

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise
The original article can be found online at https://​doi.​org/​10.​1186/​s12891-019-2741-7
Correction to: BMC Musculoskelet Disord 2019 20:360
https://doi.org/10.1186/s12891-019-2741-7
Following publication of the original article [1], the authors reported that the headers in Table 2 in their paper were omitted. The original article [1] has been updated.
The correct Table 2 is shown below.
Table 2
test-retest and interrater reproducibility of serratus anterior hand held dynamometer strenght testing
 
Test (N)
Retest (N)
Diff test-retest (N)
95% LoA (N)
ICC3.1 agreement
SEM agreement
SDC agreement
mean (SD)
mean (SD)
mean (SD)
 
(95% CI)
(N)
(N)
test-retest
 Pos A
383.88 (77.65)
404.92 (84.96)
− 21.05 (60.22)
− 139.08; 96.98
0.712 (0.420; 0.871
44,10
122,40
 Pos B
314.43 (75.1)
322.34 (82.34)
−7.90 (65.90)
− 137.06; 121.26
0.658 (0.324; 0.846)
45,80
127,00
 Pos C
351,54 (100.36)
376.16 (93.55)
−24.62 (59.37)
− 140.99; 91.75
0.794 (0.490; 0.916)
44,52
123,40
 
Tester JI
Tester HK
Diff Tester JI VS HK
    
mean (SD)
mean (SD)
mean (SD)
    
Interrater
 Pos A
383.88 (77.65)
340.44 (82.95)
43.43* (92.74)
− 138.34; 225.20
0.794; (0.552; 0.912)
55,80
196,80
Pos B
314.43 (75.10)
264.21 (61.76)
50.21* (78.85)
− 104.34; 204.76
0.277 (−0.089; 0.605)
55,80
154,50
 Pos C
351.54 (100.36)
265.10 (40,0))
86.48* (86.21)
−82.49; 255.45
0.226 (−0.107; 559)
85,31
236,47
Legend: ICC 3.1 intraclass correlation coefficient model 3.1, 95%CI 95% confidence interval, LL Lower limit, UL upper limit
N Newton, SD Standard deviation, Diff Difference, LoA limits of agreement, ICC Intraclass correlation coefficient, CI Confidence interval, SEM Standard error of measurement, SDC Smallest detectable change, % percentage
*: p < 0.001
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
download
DOWNLOAD
print
DRUCKEN
Metadaten
Titel
Correction to: Validity and reliability of serratus anterior hand held dynamometry
verfasst von
Jos IJspeert
Hans C. J. W. Kerstens
Renske M. J. Janssen
Alexander C. H. Geurts
Nens van Alfen
Jan T. Groothuis
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
BMC Musculoskeletal Disorders / Ausgabe 1/2019
Elektronische ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-019-2780-0

Weitere Artikel der Ausgabe 1/2019

BMC Musculoskeletal Disorders 1/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.