Abstract

The aim of the present study was to compare the performance of the new VITEK2 AST-P551 card with the cefoxitin disk diffusion method for the daily detection of methicillin resistance with a high number of Staphylococcus aureus clinical isolates. Detection of the PBP2a protein or mecA gene was performed for each discordant case. Seventy (3.3%) isolates out of 2,107 clinical strains showed discordant results, two very major errors, four major errors and 64 minor errors. Fifty-nine (84%) discordant results were resolved, with a final overall agreement of 99.5%. Eleven (0.5%) strains remained discordant (minor error [mE]). Four of 370 MRSA strains were misclassified as susceptible in daily practice by the cefoxitin disk diffusion method. All of these strains were resistant to aminoglycosides and/or fluoroquinolones. The VITEK2 system is highly reliable for methicillin resistance detection at the routine level. Oxacillin-susceptible classified clinical strains with associated resistance patterns required attention.
Literatur
1.
Zurück zum Zitat Clinical and Laboratory Standards Institute/NCCLS (2007) Performance Standards for Antimicrobial Susceptibility Testing. 17th informational supplement M100-S17. Clinical and Laboratory Standards Institute, Wayne Clinical and Laboratory Standards Institute/NCCLS (2007) Performance Standards for Antimicrobial Susceptibility Testing. 17th informational supplement M100-S17. Clinical and Laboratory Standards Institute, Wayne
3.
Zurück zum Zitat Okuma K, Iwakawa K, Turnidge JD, Grubb WB, Bell JM, O’Brien FG, Coombs GW, Pearman JW, Tenover FC, Kapi M, Tiensasitorn C, Ito T, Hiramatsu K (2002) Dissemination of new methicillin-resistant Staphylococcus aureus clones in the community. J Clin Microbiol 40:4289–4294CrossRefPubMed Okuma K, Iwakawa K, Turnidge JD, Grubb WB, Bell JM, O’Brien FG, Coombs GW, Pearman JW, Tenover FC, Kapi M, Tiensasitorn C, Ito T, Hiramatsu K (2002) Dissemination of new methicillin-resistant Staphylococcus aureus clones in the community. J Clin Microbiol 40:4289–4294CrossRefPubMed
4.
Zurück zum Zitat Swenson JM, Lonsway D, McAllister S, Thompson A, Jevitt L, Zhu W, Patel JB (2007) Detection of mecA-mediated resistance using reference and commercial testing methods in a collection of Staphylococcus aureus expressing borderline oxacillin MICs. Diagn Microbiol Infect Dis 58:33–39CrossRefPubMed Swenson JM, Lonsway D, McAllister S, Thompson A, Jevitt L, Zhu W, Patel JB (2007) Detection of mecA-mediated resistance using reference and commercial testing methods in a collection of Staphylococcus aureus expressing borderline oxacillin MICs. Diagn Microbiol Infect Dis 58:33–39CrossRefPubMed
5.
Zurück zum Zitat Pottumarthy S, Fritsche TR, Jones RN (2005) Evaluation of alternative disk diffusion methods for detecting mecA-mediated oxacillin resistance in an international collection of Staphylococci: validation report from the SENTRY Antimicrobial Surveillance Program. Diagn Microbiol Infect Dis 51:57–62CrossRefPubMed Pottumarthy S, Fritsche TR, Jones RN (2005) Evaluation of alternative disk diffusion methods for detecting mecA-mediated oxacillin resistance in an international collection of Staphylococci: validation report from the SENTRY Antimicrobial Surveillance Program. Diagn Microbiol Infect Dis 51:57–62CrossRefPubMed
6.
Zurück zum Zitat Felten A, Grandry B, Lagrange PH, Casin I (2002) Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus aureus (MRSA): a disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-screen latex agglutination test. J Clin Microbiol 40:2766–2771CrossRefPubMed Felten A, Grandry B, Lagrange PH, Casin I (2002) Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus aureus (MRSA): a disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-screen latex agglutination test. J Clin Microbiol 40:2766–2771CrossRefPubMed
7.
Zurück zum Zitat Skov R, Smyth R, Clausen M, Larsen AR, Frimodt-Møller N, Olsson-Liljequist B, Kahlmeter G (2003) Evaluation of a cefoxitin 30 µg disc on Iso-Sensitest agar for detection of methicillin-resistant Staphylococcus aureus. J Antimicrob Chemother 52:204–207CrossRefPubMed Skov R, Smyth R, Clausen M, Larsen AR, Frimodt-Møller N, Olsson-Liljequist B, Kahlmeter G (2003) Evaluation of a cefoxitin 30 µg disc on Iso-Sensitest agar for detection of methicillin-resistant Staphylococcus aureus. J Antimicrob Chemother 52:204–207CrossRefPubMed
8.
Zurück zum Zitat Barbier-Frebourg N, Nouet D, Lemée L, Martin E, Lemeland JF (1998) Comparison of ATB staph, rapid ATB staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in Staphylococci possessing mecA. J Clin Microbiol 36:52–57 Barbier-Frebourg N, Nouet D, Lemée L, Martin E, Lemeland JF (1998) Comparison of ATB staph, rapid ATB staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in Staphylococci possessing mecA. J Clin Microbiol 36:52–57
9.
Zurück zum Zitat Roisin S, Nonhoff C, Denis O, Struelens MJ (2008) Evaluation of new Vitek 2 card and disk diffusion method for determining susceptibility of Staphylococcus aureus to oxacillin. J Clin Microbiol 46:2525–2528CrossRefPubMed Roisin S, Nonhoff C, Denis O, Struelens MJ (2008) Evaluation of new Vitek 2 card and disk diffusion method for determining susceptibility of Staphylococcus aureus to oxacillin. J Clin Microbiol 46:2525–2528CrossRefPubMed
10.
Zurück zum Zitat Torres E, Pérez S, Villanueva R, Bou G (2008) Evaluation of the vitek 2 AST-P559 card for detection of oxacillin resistance in Staphylococcus aureus. J Clin Microbiol 46:4114–4115CrossRefPubMed Torres E, Pérez S, Villanueva R, Bou G (2008) Evaluation of the vitek 2 AST-P559 card for detection of oxacillin resistance in Staphylococcus aureus. J Clin Microbiol 46:4114–4115CrossRefPubMed
Metadaten
Titel
Correlation between the VITEK2 system and cefoxitin disk diffusion for the daily detection of oxacillin resistance in a large number of clinical Staphylococcus aureus isolates
verfasst von
P. Bemer
M. E. Juvin
G. Le Gargasson
H. Drugeon
A. Reynaud
S. Corvec
Publikationsdatum
01.06.2010
Verlag
Springer-Verlag
Erschienen in
European Journal of Clinical Microbiology & Infectious Diseases / Ausgabe 6/2010
Print ISSN: 0934-9723
Elektronische ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-010-0920-4

Weitere Artikel der Ausgabe 6/2010

European Journal of Clinical Microbiology & Infectious Diseases 6/2010 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.