Abstract

Titanium alloys are most often used in the design of dental implants. Although these biomaterials have good mechanical and biological properties, their corrosion resistance is still critical for the overall success of the treatment procedure. Implant failure is more likely to occur in inflammatory diseases related to low pH levels. Er,Cr:YSGG laser is most often used in implant dentistry.
The aim of the this study was to assess the effect of Er,Cr:YSGG laser surface treatment on the corrosion behavior of titanium alloy (Ti–6Al–4V) at different pH.

Materials and methods

A total of 40 discs were used. Twenty discs were irradiated with Er,Cr:YSGG laser, which was operating in a normal room atmosphere and temperature at power 2 W. The corrosion behavior was investigated in simulated body fluid at pH of 7.40 and 5.20. At each pH, corrosion behavior was studied for up to 864 h at 192, 360, 696, and 864 h intervals using potentiodynamic polarization test and electrochemical impedance spectroscopy. The laser-treated and -untreated discs were examined with scanning electron microscope before and after the electrochemical tests.

Result

Laser treatment significantly improves the corrosion resistance compared to the untreated group. Immersion time and pH also significantly affect the corrosion behavior. The acidity yielded more aggressive changes on the untreated titanium alloy.

Conclusion

Er,Cr:YSGG laser could improve the corrosion resistance of Ti–6Al–4V.
Literatur
1.
Zurück zum Zitat Piotrowski B, Baptista AA, Patoor E, Bravetti P, Eberhardt A, Laheurte P (2014) Interaction of bone–dental implant with new ultra low modulus alloy using a numerical approach. Mater Sci and Engin C 38:151–160CrossRef Piotrowski B, Baptista AA, Patoor E, Bravetti P, Eberhardt A, Laheurte P (2014) Interaction of bone–dental implant with new ultra low modulus alloy using a numerical approach. Mater Sci and Engin C 38:151–160CrossRef
2.
Zurück zum Zitat Triplett RG, Frohberg U, Sykaras N, Woody RD (2003) Implant materials, design and surface topographies: their influence on osseointegration of dental implants. J Long-Term Eff Med Implants 13:485–501CrossRefPubMed Triplett RG, Frohberg U, Sykaras N, Woody RD (2003) Implant materials, design and surface topographies: their influence on osseointegration of dental implants. J Long-Term Eff Med Implants 13:485–501CrossRefPubMed
3.
Zurück zum Zitat Mathew MT, Abbey S, Hallab NJ, Hall DJ, Sukotjo C, Wimmer MA (2012) Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater 100:1662–1671CrossRefPubMed Mathew MT, Abbey S, Hallab NJ, Hall DJ, Sukotjo C, Wimmer MA (2012) Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater 100:1662–1671CrossRefPubMed
4.
Zurück zum Zitat Geetha M, Durgalakshmi D, Asokamani R (2010) Biomedical implants: corrosion and its prevention—a review. Recent Patents Corros Sci 2:40–54CrossRef Geetha M, Durgalakshmi D, Asokamani R (2010) Biomedical implants: corrosion and its prevention—a review. Recent Patents Corros Sci 2:40–54CrossRef
5.
Zurück zum Zitat Gimbel CB: (2000) Hard tissue laser procedures. In: Convissar FA, Dent Clin North Am. Philadelphia, PA: Saunders 44:931–948 Gimbel CB: (2000) Hard tissue laser procedures. In: Convissar FA, Dent Clin North Am. Philadelphia, PA: Saunders 44:931–948
6.
Zurück zum Zitat Featherstone, JD: (2000) Caries detection and prevention with laser energy. In: Convissar FA, Dent Clin North Am. Philadelphia, PA; Saunders 44:955–966 Featherstone, JD: (2000) Caries detection and prevention with laser energy. In: Convissar FA, Dent Clin North Am. Philadelphia, PA; Saunders 44:955–966
7.
Zurück zum Zitat Romanos GE, Gupta B, Yunker M et al (2013) Lasers use in dental implantology. Implant Dent 22:282–288CrossRefPubMed Romanos GE, Gupta B, Yunker M et al (2013) Lasers use in dental implantology. Implant Dent 22:282–288CrossRefPubMed
8.
Zurück zum Zitat Matsumoto K, Hossain MM, Kawano H, Kimura Y (2002) Clinical assessment of Er ,Cr: YSGG laser application for cavity preparation. J Clin Laser Med Surg 20:17–21CrossRefPubMed Matsumoto K, Hossain MM, Kawano H, Kimura Y (2002) Clinical assessment of Er ,Cr: YSGG laser application for cavity preparation. J Clin Laser Med Surg 20:17–21CrossRefPubMed
9.
Zurück zum Zitat Arisan V, Karabuda CZ, Ozdemir T (2010) Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res 21(9):980–988PubMed Arisan V, Karabuda CZ, Ozdemir T (2010) Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res 21(9):980–988PubMed
10.
Zurück zum Zitat Nickenig H-J, Wichmann M, Schlegel KA, Nkenke E, Eitner S (2010) Radiographic evaluation of marginal bone levels during healing period, adjacent to parallel-screw cylinder implants inserted in the posterior zone of the jaws, placed with flapless surgery. Clin Oral Implants Res 21(12):1386–1393CrossRefPubMed Nickenig H-J, Wichmann M, Schlegel KA, Nkenke E, Eitner S (2010) Radiographic evaluation of marginal bone levels during healing period, adjacent to parallel-screw cylinder implants inserted in the posterior zone of the jaws, placed with flapless surgery. Clin Oral Implants Res 21(12):1386–1393CrossRefPubMed
11.
Zurück zum Zitat Gomez-Santos L, Arnabat-Dominguez J, Sierra-Rebolledo A, Gay-Escoda C (2010) Thermal increment due to Er,Cr:YSGG and CO2 laser irradiation of different implant surfaces. Apilot study. Med Oral Patol Oral Cir Bucal 15:782–787CrossRef Gomez-Santos L, Arnabat-Dominguez J, Sierra-Rebolledo A, Gay-Escoda C (2010) Thermal increment due to Er,Cr:YSGG and CO2 laser irradiation of different implant surfaces. Apilot study. Med Oral Patol Oral Cir Bucal 15:782–787CrossRef
12.
Zurück zum Zitat Hansen DC (2008) Metal corrosion in the human body: the ultimate bio-corrosion scenario. Electrochem Soc Interface 17:24–27 Hansen DC (2008) Metal corrosion in the human body: the ultimate bio-corrosion scenario. Electrochem Soc Interface 17:24–27
13.
Zurück zum Zitat Sato N. (2012) Basics of corrosion chemistry.Green corrosion chemistry and engineering 1st edition Sato N. (2012) Basics of corrosion chemistry.Green corrosion chemistry and engineering 1st edition
14.
Zurück zum Zitat Schmutz P, Quach-Vu N, Gerber I (2008) Metallic medical implants: electrochemical characterization of corrosion processes. Electrochem Soc Interface 17:35–40 Schmutz P, Quach-Vu N, Gerber I (2008) Metallic medical implants: electrochemical characterization of corrosion processes. Electrochem Soc Interface 17:35–40
15.
Zurück zum Zitat Al-Mobarak NA, Al-Swayih AA, Al-Rashod FA (2011) Corrosion behavior of Ti-6Al-7Nb alloy in biological solution for dentistry applications. Int J Electrochem Sci 6:2031–2042 Al-Mobarak NA, Al-Swayih AA, Al-Rashod FA (2011) Corrosion behavior of Ti-6Al-7Nb alloy in biological solution for dentistry applications. Int J Electrochem Sci 6:2031–2042
16.
Zurück zum Zitat Lee JH, Heo SJ, Koak JY, Kim SK, Lee SJ, Lee SH (2008) Cellular responses on anodized titanium discs after laser irradiation. Lasers Surg Med 40:738–742CrossRefPubMed Lee JH, Heo SJ, Koak JY, Kim SK, Lee SJ, Lee SH (2008) Cellular responses on anodized titanium discs after laser irradiation. Lasers Surg Med 40:738–742CrossRefPubMed
17.
Zurück zum Zitat Neupane MP, Park IS, Lee MH (2014) Surface characterization and corrosion behavior of micro-arc oxidized Ti surface modified with hydrothermal treatment and chitosan coating. Thin Solid Films 550:268–271CrossRef Neupane MP, Park IS, Lee MH (2014) Surface characterization and corrosion behavior of micro-arc oxidized Ti surface modified with hydrothermal treatment and chitosan coating. Thin Solid Films 550:268–271CrossRef
18.
Zurück zum Zitat Jiang Z, Dai X, Norby T, Middleton H (2011) Investigation of pitting resistance of titanium based on a modified point defect model. Corros Sci 53:815–821CrossRef Jiang Z, Dai X, Norby T, Middleton H (2011) Investigation of pitting resistance of titanium based on a modified point defect model. Corros Sci 53:815–821CrossRef
19.
Zurück zum Zitat Antunes RA, De Oliveira MCL, Costa I (2012) Study of the correlation between corrosion resistance and semi-conducting properties of the passive film of AISI 316 L stainless steel in physiological solution. Mater Corros 63:586–592 Antunes RA, De Oliveira MCL, Costa I (2012) Study of the correlation between corrosion resistance and semi-conducting properties of the passive film of AISI 316 L stainless steel in physiological solution. Mater Corros 63:586–592
20.
Zurück zum Zitat Robin A, Carvalho OAS, Schneider SG, Schneider S. (2008) Corrosion behavior of Ti-xNb-13-Zr alloys in Ringer’s solution, Mater Corrosion 59: 929–933 Robin A, Carvalho OAS, Schneider SG, Schneider S. (2008) Corrosion behavior of Ti-xNb-13-Zr alloys in Ringer’s solution, Mater Corrosion 59: 929–933
21.
Zurück zum Zitat Guo HX, Lu BT, Luo JL (2006) Non-Faraday material loss in flowing corrosive solution. Electrochim Acta 51:5341–5348CrossRef Guo HX, Lu BT, Luo JL (2006) Non-Faraday material loss in flowing corrosive solution. Electrochim Acta 51:5341–5348CrossRef
22.
Zurück zum Zitat Munirathinam B, Neelakantan L (2015) Titania nanotubes from weak organic acid electrolyte: fabrication, characterization and oxide film properties. Mater Sci Eng C 49:567–578CrossRef Munirathinam B, Neelakantan L (2015) Titania nanotubes from weak organic acid electrolyte: fabrication, characterization and oxide film properties. Mater Sci Eng C 49:567–578CrossRef
23.
Zurück zum Zitat Park JH, Heo SJ, Koak JY, Kim SK, Han CH, Lee JH (2012) Effects of laser irradiation on machined and anodized titanium disks. Int J Oral Maxillofac Implants 27:265–272PubMed Park JH, Heo SJ, Koak JY, Kim SK, Han CH, Lee JH (2012) Effects of laser irradiation on machined and anodized titanium disks. Int J Oral Maxillofac Implants 27:265–272PubMed
24.
Zurück zum Zitat Miller RJ (2004) Treatment of the contaminated implant surface using Er,Cr:YSGG laser. Implant Dent 13:165–170CrossRefPubMed Miller RJ (2004) Treatment of the contaminated implant surface using Er,Cr:YSGG laser. Implant Dent 13:165–170CrossRefPubMed
25.
Zurück zum Zitat Li Y, Zhang T, Wang F (2006) Effect of microcrystallization on corrosion resistance of AZ91D alloy. Electrochim Acta 51:2845–2850CrossRef Li Y, Zhang T, Wang F (2006) Effect of microcrystallization on corrosion resistance of AZ91D alloy. Electrochim Acta 51:2845–2850CrossRef
26.
Zurück zum Zitat Singh R, Kurella A, Dahotre NB (2006) Laser surface modification of Ti-6Al-4V: wear and corrosion characterization in simulated biofluid. J Biomater Appl 21(1):49–73CrossRefPubMed Singh R, Kurella A, Dahotre NB (2006) Laser surface modification of Ti-6Al-4V: wear and corrosion characterization in simulated biofluid. J Biomater Appl 21(1):49–73CrossRefPubMed
27.
Zurück zum Zitat Biswas A, Li L, Maity TK, Chatterjee UK, Mordike BL, Manna I, Dutta MJ (2007) Laser surface treatment of Ti-6Al-4V for bio-implant application. Lasers Eng 17:59–73 Biswas A, Li L, Maity TK, Chatterjee UK, Mordike BL, Manna I, Dutta MJ (2007) Laser surface treatment of Ti-6Al-4V for bio-implant application. Lasers Eng 17:59–73
28.
Zurück zum Zitat Zaveri N, Mahapatra M, Deceuster A, Peng Y, Li L, Zhou A (2008) Corrosion resistance of pulsed laser-treated Ti-6Al-4V implant in simulated biofluids. Electrochim Acta 53(15):5022–5032CrossRef Zaveri N, Mahapatra M, Deceuster A, Peng Y, Li L, Zhou A (2008) Corrosion resistance of pulsed laser-treated Ti-6Al-4V implant in simulated biofluids. Electrochim Acta 53(15):5022–5032CrossRef
Metadaten
Titel
Corrosion behavior of erbium chromium-doped yattrium-scandium-gallium-garnet (Er,Cr:YSGG 2780 nm) laser-treated titanium alloy used for dental applications at different pH conditions (in vitro study)
verfasst von
Dalia A. Abd El daym
Mostafa E. Gheith
Nadia A. Abbas
Laila A. Rashed
Zeinab A. Abd El Aziz
Publikationsdatum
10.04.2018
Verlag
Springer International Publishing
Erschienen in
Lasers in Dental Science / Ausgabe 3/2018
Elektronische ISSN: 2367-2587
DOI
https://doi.org/10.1007/s41547-018-0030-7

Weitere Artikel der Ausgabe 3/2018

Lasers in Dental Science 3/2018 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.