Skip to main content
Erschienen in: Critical Care 1/2018

Open Access 01.12.2018 | Letter

Could ultrasound-guided internal jugular vein catheter insertion replace the use of chest X-ray?

verfasst von: William F. Amaya-Zuñiga, Fernando Raffán-Sanabria

Erschienen in: Critical Care | Ausgabe 1/2018

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
The implementation of ultrasound protocols during catheter placement has demonstrated multiple advantages that increase accuracy and allow medical teams to reduce operative time, potential complications, and procedure costs [1, 2]. The wide use of lung and cardiac ultrasound in perioperative medicine enables earlier diagnosis of some acute complications, allowing prompt intervention and control of damage.
We present the Successful Ultrasound-Guided Internal Jugular Vein Catheter Insertion algorithm (Fig. 1), which is based on reports of safe vascular ultrasound protocols in daily practice [3, 4]. It follows an operational pipeline that integrates steps focused on adequate vascular identification, cannulation, and placement of the catheter. The operational steps are:
  • 1, 2 - A 2D vascular ultrasound in the Trendelenburg position identifies vessel characteristics and determines the “margin of safety”. If an overlap of the artery is present, there is a high possibility of artery injury.
  • 3-Assessment of color Doppler and pulsed Doppler completes the vascular identification, which can differentiate their flows and discount the presence of thrombus.
  • 4, 5 – Evaluation of a safety margin could guide modifications of puncture angles, avoiding injuries of the anterior or lateral artery wall.
  • 6-After getting venous return, guidewire advancement should be smooth and unobstructed and the thoracic direction needs to be confirmed. The presence of intraluminal dissection or false pathways should be detected.
  • 7, 8 - In the subcostal echocardiogram view, guidewire and catheter identification close to the heart helps to optimize adequate placement. The saline flush confirmation test can help to confirm this, but it should not be performed routinely.
  • 9- Although the use of ultrasound in real time for central venous access reduces the number of pleuropulmonary complications, a lung ultrasound assessment should be performed, seeking to identify potential associated lesions, guaranteeing prompt attention to the patient.
The application of this algorithm optimizes the use of bedside ultrasound as a diagnostic tool, organizes the steps, and increases the early identification of potential operational errors. Rapid interventions significantly reduce the clinical impact on the patient and avoid the use of chest X-ray. Limitations for its implementation include the availability of the equipment with probes and staff training. This algorithm could also be useful in subclavian venous catheter placement, although the evidence does not statistically support the use of ultrasound for this application.
Not applicable.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Troianos CA, Hartman GS, Glas KE, et al. Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr. 2011;24:1291–318.CrossRefPubMed Troianos CA, Hartman GS, Glas KE, et al. Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr. 2011;24:1291–318.CrossRefPubMed
2.
Zurück zum Zitat Rupp SM, Apfelbaum JL, Blitt C, et al. Practice guidelines for central venous access: a report by the American Society of Anesthesiologists Task Force on central venous access. American Society of Anesthesiologists Task Force on central venous access. Anesthesiology. 2012;116:539–73.CrossRefPubMed Rupp SM, Apfelbaum JL, Blitt C, et al. Practice guidelines for central venous access: a report by the American Society of Anesthesiologists Task Force on central venous access. American Society of Anesthesiologists Task Force on central venous access. Anesthesiology. 2012;116:539–73.CrossRefPubMed
3.
Zurück zum Zitat Amaya-Zuñiga WF, Raffan-Sanabria F, Niño de Mejía C, et al. Internal jugular vein cannulation: how much safety can we offer? Rev Colomb Anestesiol. 2015;43:76–86.CrossRef Amaya-Zuñiga WF, Raffan-Sanabria F, Niño de Mejía C, et al. Internal jugular vein cannulation: how much safety can we offer? Rev Colomb Anestesiol. 2015;43:76–86.CrossRef
4.
Zurück zum Zitat Saugel B, Scheeren TWL, Teboul JL. Ultrasound-guided central venous catheter placement: a structured review and recommendationsfor clinical practice. Crit Care. 2017;21(1):225.CrossRefPubMedPubMedCentral Saugel B, Scheeren TWL, Teboul JL. Ultrasound-guided central venous catheter placement: a structured review and recommendationsfor clinical practice. Crit Care. 2017;21(1):225.CrossRefPubMedPubMedCentral
Metadaten
Titel
Could ultrasound-guided internal jugular vein catheter insertion replace the use of chest X-ray?
verfasst von
William F. Amaya-Zuñiga
Fernando Raffán-Sanabria
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2018
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-018-2130-x

Weitere Artikel der Ausgabe 1/2018

Critical Care 1/2018 Zur Ausgabe

Update AINS