Skip to main content
Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases 12/2020

17.08.2020 | COVID-19 | Original Article Zur Zeit gratis

Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2

verfasst von: Gladys Virginia Guedez-López, Marina Alguacil-Guillén, Patricia González-Donapetry, Ivan Bloise, Carolina Tornero-Marin, Juan González-García, Jesus Mingorance, Julio García-Rodríguez, on behalf of the SARS-CoV-2 Working Group

Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases | Ausgabe 12/2020

Einloggen, um Zugang zu erhalten

Abstract

Lateral flow immunoassays (LFIA) for rapid detection of specific antibodies (IgM and IgG) against SARS-CoV-2 in different human specimens have been developed in response to the pandemic. The aim of this study is to evaluate three immunocromathographic assays (Sienna®, Wondfo® and Prometheus®) for detection of antibodies against SARS-CoV-2 in serum samples, considering RT-qPCR as a reference. A total of 145 serum samples from 145 patients with clinical suspicion of COVID-19 were collected: all of the samples were tested with Sienna®, 117 with Wondfo® and 89 with Prometheus®. The overall results of sensitivity, specificity, positive predictive value and negative predictive value obtained were as follows: 64.4%, 75%, 85.5% and 47.8% with Sienna®; 45.2%, 81.8%, 80.5% and 47.4% with Wondfo® and 75.5%, 12.5%, 51.4% and 29.4% with Prometheus®. The accuracy of the test for Sienna®, Wondfo® and Prometheus® was 67.6%, 59% and 47.2%, with a prevalence of COVID-19 of 69.7%, 62.4% and 55.1% respectively. Sensitivity of the three tests (Sienna®, Wondfo® and Prometheus® respectively) along the three different stages was 36.6%, 18.8% and 68.6% in the early stage (first week); 81.3%, 74.1% and 90.9% in the intermediate stage (second week) and 100%, 83.3% and 100% in the late stage (third week). The results demonstrate that even though Prometheus® presented a high sensitivity, the specificity was notably lower than the other two tests. Sienna® showed the greatest contrast between sensitivity and specificity, achieving the best accuracy, followed by Wondfo®. The sensitivity of the three ICT assays was higher in late stages of the disease.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Zhu N, Zhang D, Wang W, Li X, Yang B, Song J, Zhao X, Huang B, Shi W, Lu R, Niu P, Zhan F, Ma X, Wang D, Xu W, Wu G, Gao GF, Tan W (2020) A novel coronavirus from patients with pneumonia in China, 2019. N Engl J Med 382:727–733CrossRef Zhu N, Zhang D, Wang W, Li X, Yang B, Song J, Zhao X, Huang B, Shi W, Lu R, Niu P, Zhan F, Ma X, Wang D, Xu W, Wu G, Gao GF, Tan W (2020) A novel coronavirus from patients with pneumonia in China, 2019. N Engl J Med 382:727–733CrossRef
2.
Zurück zum Zitat Lu R, Zhao X, Li J, Niu P, Yang B, Wu H, Wang W, Song H, Huang B, Zhu N, Bi Y, Ma X, Zhan F, Wang L, Hu T, Zhou H, Hu Z, Zhou W, Zhao L, Chen J, Meng Y, Wang J, Lin Y, Yuan J, Xie Z, Ma J, Liu WJ, Wang D, Xu W, Holmes EC, Gao GF, Wu G, Chen W, Shi W, Tan W (2020) Genomic characterisation and epidemiology of 2019 novel coronavirus: implications for virus origins and receptor binding. Lancet 395:565–574CrossRef Lu R, Zhao X, Li J, Niu P, Yang B, Wu H, Wang W, Song H, Huang B, Zhu N, Bi Y, Ma X, Zhan F, Wang L, Hu T, Zhou H, Hu Z, Zhou W, Zhao L, Chen J, Meng Y, Wang J, Lin Y, Yuan J, Xie Z, Ma J, Liu WJ, Wang D, Xu W, Holmes EC, Gao GF, Wu G, Chen W, Shi W, Tan W (2020) Genomic characterisation and epidemiology of 2019 novel coronavirus: implications for virus origins and receptor binding. Lancet 395:565–574CrossRef
3.
Zurück zum Zitat Corman VM, Landt O, Kaiser M, Molenkamp R, Meijer A, Chu DK, Bleicker T, Brünink S, Schneider J, Schmidt ML, Mulders DG, Haagmans BL, van der Veer B, van den Brink S, Wijsman L, Goderski G, Romette JL, Ellis J, Zambon M, Peiris M, Goossens H, Reusken C, Koopmans MP, Drosten C (2020) Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill 25:1–8 Corman VM, Landt O, Kaiser M, Molenkamp R, Meijer A, Chu DK, Bleicker T, Brünink S, Schneider J, Schmidt ML, Mulders DG, Haagmans BL, van der Veer B, van den Brink S, Wijsman L, Goderski G, Romette JL, Ellis J, Zambon M, Peiris M, Goossens H, Reusken C, Koopmans MP, Drosten C (2020) Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill 25:1–8
4.
Zurück zum Zitat Loeffelholz MJ, Tang Y-W (1751) Laboratory diagnosis of emerging human coronavirus infections — the state of the art. Emerg Microbes Infect 2020:1–26 Loeffelholz MJ, Tang Y-W (1751) Laboratory diagnosis of emerging human coronavirus infections — the state of the art. Emerg Microbes Infect 2020:1–26
5.
Zurück zum Zitat Tang Y-W, Schmitz JE, Persing DH, Stratton CW (2020) The laboratory diagnosis of COVID-19 infection: current issues and challenges. J Clin Microbiol:1–22 Tang Y-W, Schmitz JE, Persing DH, Stratton CW (2020) The laboratory diagnosis of COVID-19 infection: current issues and challenges. J Clin Microbiol:1–22
6.
Zurück zum Zitat World Health Organization.: World Health Organization (2020) Laboratory testing for coronavirus disease 2019 ( COVID-19 ) in suspected human cases: : interim guidance, 2 March 2020. 2019, (2020) World Health Organization.: World Health Organization (2020) Laboratory testing for coronavirus disease 2019 ( COVID-19 ) in suspected human cases: : interim guidance, 2 March 2020. 2019, (2020)
7.
Zurück zum Zitat Wikramaratna P, Paton RS, Ghafari M, Kingdom U (2020) Estimating false-negative detection rate of SARS-CoV-2 by RT-PCR. 413, 0–13 Wikramaratna P, Paton RS, Ghafari M, Kingdom U (2020) Estimating false-negative detection rate of SARS-CoV-2 by RT-PCR. 413, 0–13
8.
Zurück zum Zitat Ai T, Yang Z, Hou H, Zhan C, Chen C, Lv W, Tao Q, Sun Z, Xia L (2019) Correlation of chest CT and RT-PCR testing in coronavirus disease 2019 (COVID-19) in China: a report of 1014 cases. Radiology 2020:200642 Ai T, Yang Z, Hou H, Zhan C, Chen C, Lv W, Tao Q, Sun Z, Xia L (2019) Correlation of chest CT and RT-PCR testing in coronavirus disease 2019 (COVID-19) in China: a report of 1014 cases. Radiology 2020:200642
9.
Zurück zum Zitat Xie X, Zhong Z, Zhao W, Zheng C, Wang F, Liu J (Radiology, 2020) Chest CT for typical 2019-nCoV pneumonia: relationship to negative RT-PCR testing. 2003(43) Xie X, Zhong Z, Zhao W, Zheng C, Wang F, Liu J (Radiology, 2020) Chest CT for typical 2019-nCoV pneumonia: relationship to negative RT-PCR testing. 2003(43)
10.
Zurück zum Zitat Zhong B-L, Luo W, Li H-MH, Zhang Q-Q, Liu X-G, Li W-T, Li Y, Yi Li O, Rd G, Lee A, Zhou F, Yu T, Du R, Fan G, Liu Y, Liu Z, Xiang J, Wang Y, Song B, Gu X, Guan L, Wei Y, Li H-MH, Wu X, Xu J, Tu S, Zhang Y, Chen H, Cao B, Remuzzi A, Remuzzi G, Lai CC, Shih TP, Ko WC, Tang HJ, Hsueh PR, شكري م،, Zhao Y, Xu H, Gao J, Tian Z, Yang X, Prevention CC for DC and, Wu Z, McGoogan JM, Numbers SIN, Heymann DL, Shindo N, Dong E, Du H, Gardner L, Khader Y, Al Nsour M, Al Serouri A, Ikram A, Malik E, Saeed K, Abdalla AM, Belalia A, Assarag B, Baig MA, Almudarra S, Arqoub K, Osman S, Bashier H, Abu-Khader I, Shalabi D, Mirbolouki M, Behzadi MH, Korzaledin M, Qarawi ATA, Ng SJ, Gad A, Mai LN, AL-Ahdal TMA, Sharma A, Huan VT, Vuong NL, Tawfik GM, Hashan MR, Dumre SP, Ghozy S, Shaikhkhalil H, Mahmoud MH, Alhady STM, Nam NH, Islam SMS, Smith C, Lee PNC, Chico M, Cox S, Hirayama K, Huy NT, Bedoya G, Dolinger A, Liu Y, Gayle AA, Wilder-Smith A, Rocklöv J (2020) Sensitivity of chest CT for COVID-19: comparison to RT-PCR. Lancet 395:1–A2 Zhong B-L, Luo W, Li H-MH, Zhang Q-Q, Liu X-G, Li W-T, Li Y, Yi Li O, Rd G, Lee A, Zhou F, Yu T, Du R, Fan G, Liu Y, Liu Z, Xiang J, Wang Y, Song B, Gu X, Guan L, Wei Y, Li H-MH, Wu X, Xu J, Tu S, Zhang Y, Chen H, Cao B, Remuzzi A, Remuzzi G, Lai CC, Shih TP, Ko WC, Tang HJ, Hsueh PR, شكري م،, Zhao Y, Xu H, Gao J, Tian Z, Yang X, Prevention CC for DC and, Wu Z, McGoogan JM, Numbers SIN, Heymann DL, Shindo N, Dong E, Du H, Gardner L, Khader Y, Al Nsour M, Al Serouri A, Ikram A, Malik E, Saeed K, Abdalla AM, Belalia A, Assarag B, Baig MA, Almudarra S, Arqoub K, Osman S, Bashier H, Abu-Khader I, Shalabi D, Mirbolouki M, Behzadi MH, Korzaledin M, Qarawi ATA, Ng SJ, Gad A, Mai LN, AL-Ahdal TMA, Sharma A, Huan VT, Vuong NL, Tawfik GM, Hashan MR, Dumre SP, Ghozy S, Shaikhkhalil H, Mahmoud MH, Alhady STM, Nam NH, Islam SMS, Smith C, Lee PNC, Chico M, Cox S, Hirayama K, Huy NT, Bedoya G, Dolinger A, Liu Y, Gayle AA, Wilder-Smith A, Rocklöv J (2020) Sensitivity of chest CT for COVID-19: comparison to RT-PCR. Lancet 395:1–A2
11.
Zurück zum Zitat Cao G, Wang H, Li C. One nosocomial cluster following with a familial cluster of COVID-19 cases : the potential transmission risk in patients with negative swab tests. 1–15 Cao G, Wang H, Li C. One nosocomial cluster following with a familial cluster of COVID-19 cases : the potential transmission risk in patients with negative swab tests. 1–15
12.
Zurück zum Zitat Guo L, Ren L, Yang S, Xiao M, Chang D, Yang F, Cruz S Dela Wang Y, Wu C, Xiao Y, Zhang L (2020) Profiling early humoral response to diagnose novel coronavirus disease ( COVID-19). 1–8 Guo L, Ren L, Yang S, Xiao M, Chang D, Yang F, Cruz S Dela Wang Y, Wu C, Xiao Y, Zhang L (2020) Profiling early humoral response to diagnose novel coronavirus disease ( COVID-19). 1–8
13.
Zurück zum Zitat Zhao J, Yuan Q, Wang H, Liu W, Liao X, Wang X, Yuan J, Li T, Li J, Qian S, Hong C, Fu Y, Ge S, Liu L, Zhang J, Xia N (2020) Antibody responses to SARS-CoV-2 in patients of novel coronavirus disease 2019 Zhao J, Yuan Q, Wang H, Liu W, Liao X, Wang X, Yuan J, Li T, Li J, Qian S, Hong C, Fu Y, Ge S, Liu L, Zhang J, Xia N (2020) Antibody responses to SARS-CoV-2 in patients of novel coronavirus disease 2019
14.
Zurück zum Zitat Three C, Central G, Public T, Hospital TS, Authors C, Huang A (2020) Antibody responses to SARS-CoV-2 in COVID-19 patients: the perspective application of serological tests in clinical practice Three C, Central G, Public T, Hospital TS, Authors C, Huang A (2020) Antibody responses to SARS-CoV-2 in COVID-19 patients: the perspective application of serological tests in clinical practice
15.
Zurück zum Zitat Theel ES, Slev P, Wheeler S, Couturier MR, Wong SJ (2020) Kadkhoda: the role of antobody testing for SARS-CoV-2: is there one? 1–15 Theel ES, Slev P, Wheeler S, Couturier MR, Wong SJ (2020) Kadkhoda: the role of antobody testing for SARS-CoV-2: is there one? 1–15
16.
Zurück zum Zitat Lin D, Liu L, Zhang M, Hu Y, Yang Q, Guo J (2020) Evaluations of serological test in the diagnosis of 2019 novel coronavirus (SARS-CoV-2) infections during the COVID-19 outbreak Lin D, Liu L, Zhang M, Hu Y, Yang Q, Guo J (2020) Evaluations of serological test in the diagnosis of 2019 novel coronavirus (SARS-CoV-2) infections during the COVID-19 outbreak
17.
Zurück zum Zitat Zhang W, Du RH, Li B, Zheng XS, Lou YX, Hu B, Wang YY, Xiao GF, Yan B, Shi ZL, Zhou P (2020) Molecular and serological investigation of 2019-nCoV infected patients: implication of multiple shedding routes. Emerg Microbes Infect 9:386–389CrossRef Zhang W, Du RH, Li B, Zheng XS, Lou YX, Hu B, Wang YY, Xiao GF, Yan B, Shi ZL, Zhou P (2020) Molecular and serological investigation of 2019-nCoV infected patients: implication of multiple shedding routes. Emerg Microbes Infect 9:386–389CrossRef
18.
Zurück zum Zitat Li Z, Yi Y, Luo X, Xiong N, Liu Y, Li S, Sun R, Wang Y, Hu B, Chen W, Zhang Y, Wang J, Huang B, Lin Y, Yang J, Cai W, Wang X, Cheng J, Chen Z, Sun K, Pan W, Zhan Z, Chen L, Ye F (2020) Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis. J Med Virol 0–1 Li Z, Yi Y, Luo X, Xiong N, Liu Y, Li S, Sun R, Wang Y, Hu B, Chen W, Zhang Y, Wang J, Huang B, Lin Y, Yang J, Cai W, Wang X, Cheng J, Chen Z, Sun K, Pan W, Zhan Z, Chen L, Ye F (2020) Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis. J Med Virol 0–1
19.
Zurück zum Zitat Bao L, Deng W, Gao H, Xiao C, Liu J, Xue J, Lv Q, Liu J, Yu P, Xu Y, Qi F, Qu Y, Li F, Xiang Z, Yu H, Gong S, Liu M, Wang G, Wang S, Song Z, Liu Y, Zhao W, Han L, Liu X, Wei Q, Chuan Q (2020) Lack of reinfection in rhesus macaques infected with SARS-CoV-2. bioRxiv. https://doi.org/10.1101/2020.03.13.990226 Bao L, Deng W, Gao H, Xiao C, Liu J, Xue J, Lv Q, Liu J, Yu P, Xu Y, Qi F, Qu Y, Li F, Xiang Z, Yu H, Gong S, Liu M, Wang G, Wang S, Song Z, Liu Y, Zhao W, Han L, Liu X, Wei Q, Chuan Q (2020) Lack of reinfection in rhesus macaques infected with SARS-CoV-2. bioRxiv. https://​doi.​org/​10.​1101/​2020.​03.​13.​990226
20.
Zurück zum Zitat Bao L, Deng W, Gao H, Xiao C, Liu J, Xue J, Liu J, Yu P, Xu Y, Qi F, Qu Y, Li F, Yu H, Gong S, Liu M, Wang G, Wang S, Song Z, Zhao W, Han Y, Zhao L, Liu X, Wei Q, Infectious R, Hospital BA (2020) Reinfection could not occur in SARS-CoV-2 infected rhesus macaques. bioRxiv. https://doi.org/10.1101/2020.03.13.990226 Bao L, Deng W, Gao H, Xiao C, Liu J, Xue J, Liu J, Yu P, Xu Y, Qi F, Qu Y, Li F, Yu H, Gong S, Liu M, Wang G, Wang S, Song Z, Zhao W, Han Y, Zhao L, Liu X, Wei Q, Infectious R, Hospital BA (2020) Reinfection could not occur in SARS-CoV-2 infected rhesus macaques. bioRxiv. https://​doi.​org/​10.​1101/​2020.​03.​13.​990226
21.
Zurück zum Zitat Bentivegna E. New IgM seroconversion and positive RT-PCR test after exposure to the virus in recovered COVID-19 patient. J Med Virol 0–1 Bentivegna E. New IgM seroconversion and positive RT-PCR test after exposure to the virus in recovered COVID-19 patient. J Med Virol 0–1
22.
Zurück zum Zitat Hoang VT, Dao TL, Gautret P (2020) Recurrence of positive SARS - CoV - 2 in patients recovered from COVID - 19. J Med Virol n/a, 1–2 Hoang VT, Dao TL, Gautret P (2020) Recurrence of positive SARS - CoV - 2 in patients recovered from COVID - 19. J Med Virol n/a, 1–2
23.
Zurück zum Zitat Lan L, Xu D, Ye G, Xia C, Wang S, Li Y, Xu H (2020) Positive RT-PCR test results in patients recovered from COVID-19. J Am Med Assoc 323 Lan L, Xu D, Ye G, Xia C, Wang S, Li Y, Xu H (2020) Positive RT-PCR test results in patients recovered from COVID-19. J Am Med Assoc 323
24.
Zurück zum Zitat Li Y, Yao L, Li J, Chen L, Song Y, Cai Z, Yang C (2020) Stability issues of RT - PCR testing of SARS - CoV - 2 for hospitalized patients clinically diagnosed with COVID - 19. J Med Virol 1–6 Li Y, Yao L, Li J, Chen L, Song Y, Cai Z, Yang C (2020) Stability issues of RT - PCR testing of SARS - CoV - 2 for hospitalized patients clinically diagnosed with COVID - 19. J Med Virol 1–6
25.
Zurück zum Zitat Xiao AT, Tong YX, Zhan X (2020) False-negative of RT-PCR and prolonged nucleic acid conversion in COVID-19: rather than recurrence. J Med Virol 0–3 Xiao AT, Tong YX, Zhan X (2020) False-negative of RT-PCR and prolonged nucleic acid conversion in COVID-19: rather than recurrence. J Med Virol 0–3
26.
Zurück zum Zitat Pan Y, Li X, Yang G, Fan J, Tang Y, Zhao J, Long X, Guo S, Zhao Z, Liu Y, Hu H, Xue H, Li Y (2020) Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients. medRxiv Pan Y, Li X, Yang G, Fan J, Tang Y, Zhao J, Long X, Guo S, Zhao Z, Liu Y, Hu H, Xue H, Li Y (2020) Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients. medRxiv
27.
Zurück zum Zitat (2020) Advice on the use of point-of-care immunodiagnostic tests for COVID-19. 14–16 (2020) Advice on the use of point-of-care immunodiagnostic tests for COVID-19. 14–16
28.
Zurück zum Zitat Krammer F, Simon V (2020) Serology assays to manage COVID-19. 1227: 1–5 Krammer F, Simon V (2020) Serology assays to manage COVID-19. 1227: 1–5
29.
Zurück zum Zitat Yongchen Z, Shen H, Wang X, Shi X, Li Y, Yan J, Chen Y, Gu B (2020) Different longitudinal patterns of nucleic acid and serology testing results based on disease severity of COVID-19 patients. 1751 Yongchen Z, Shen H, Wang X, Shi X, Li Y, Yan J, Chen Y, Gu B (2020) Different longitudinal patterns of nucleic acid and serology testing results based on disease severity of COVID-19 patients. 1751
Metadaten
Titel
Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2
verfasst von
Gladys Virginia Guedez-López
Marina Alguacil-Guillén
Patricia González-Donapetry
Ivan Bloise
Carolina Tornero-Marin
Juan González-García
Jesus Mingorance
Julio García-Rodríguez
on behalf of the SARS-CoV-2 Working Group
Publikationsdatum
17.08.2020
Verlag
Springer Berlin Heidelberg
Schlagwort
COVID-19
Erschienen in
European Journal of Clinical Microbiology & Infectious Diseases / Ausgabe 12/2020
Print ISSN: 0934-9723
Elektronische ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-020-04010-7

Weitere Artikel der Ausgabe 12/2020

European Journal of Clinical Microbiology & Infectious Diseases 12/2020 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.