Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 2/2021

15.06.2020 | COVID-19 | Editorial Zur Zeit gratis

The case for a 3rd generation supraglottic airway device facilitating direct vision placement

verfasst von: André A. J. Van Zundert, Chandra M. Kumar, Tom C. R. V. Van Zundert, Stephen P. Gatt, Jaideep J. Pandit

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 2/2021

Einloggen, um Zugang zu erhalten

Abstract

Although 1st and 2nd generation supraglottic airway devices (SADs) have many desirable features, they are nevertheless inserted in a similar ‘blind’ way as their 1st generation predecessors. Clinicians mostly still rely entirely on subjective indirect assessments to estimate correct placement which supposedly ensures a tight seal. Malpositioning and potential airway compromise occurs in more than half of placements. Vision-guided insertion can improve placement. In this article we propose the development of a 3rd generation supraglottic airway device, equipped with cameras and fiberoptic illumination, to visualise insertion of the device, enable immediate manoeuvres to optimise SAD position, verify whether correct 1st and 2nd seals are achieved and check whether size selected is appropriate. We do not provide technical details of such a ‘3rd generation’ device, but rather present a theoretical analysis of its desirable properties, which are essential to overcome the remaining limitations of current 1st and 2nd generation devices. We also recommend that this further milestone improvement, i.e. ability to place the SAD accurately under direct vision, be eligible for the moniker ‘3rd generation’. Blind insertion of SADs should become the exception and we anticipate, as in other domains such as central venous cannulation and nerve block insertions, vision-guided placement becoming the gold standard.
Literatur
1.
Zurück zum Zitat Cook TM. Third generation supraglottic airway devices: an undefined concept and misused term. Time for an updated classification of supraglottic airway devices. Br J Anaesth. 2015;115:633.PubMedCrossRef Cook TM. Third generation supraglottic airway devices: an undefined concept and misused term. Time for an updated classification of supraglottic airway devices. Br J Anaesth. 2015;115:633.PubMedCrossRef
2.
Zurück zum Zitat Miller DM. Third generation supraglottic airways: is a new classification needed? Br J Anaesth. 2015;115:634.PubMedCrossRef Miller DM. Third generation supraglottic airways: is a new classification needed? Br J Anaesth. 2015;115:634.PubMedCrossRef
4.
Zurück zum Zitat Brain AIJ. The laryngeal mask—a new concept in airway management. Br J Anaesth. 1983;55:801–5.PubMedCrossRef Brain AIJ. The laryngeal mask—a new concept in airway management. Br J Anaesth. 1983;55:801–5.PubMedCrossRef
5.
Zurück zum Zitat Avery EC. The Leech airway: precursor to the modern supraglottic airway. Can J Anaesth. 2018;65:586–7.PubMedCrossRef Avery EC. The Leech airway: precursor to the modern supraglottic airway. Can J Anaesth. 2018;65:586–7.PubMedCrossRef
6.
Zurück zum Zitat Brain AIJ, Verghese C, Strube PJ. The LMA-ProSeal—a laryngeal mask with an oesophageal vent. Br J Anaesth. 2000;84:650–4.PubMedCrossRef Brain AIJ, Verghese C, Strube PJ. The LMA-ProSeal—a laryngeal mask with an oesophageal vent. Br J Anaesth. 2000;84:650–4.PubMedCrossRef
7.
Zurück zum Zitat Van Zundert TC, Brimacombe JR, Ferson DZ, Bacon DR, Wilkinson DJ. Archie brain: celebrating 30 years of development in laryngeal mask airways. Anaesthesia. 2012;67:1375–85.PubMedCrossRef Van Zundert TC, Brimacombe JR, Ferson DZ, Bacon DR, Wilkinson DJ. Archie brain: celebrating 30 years of development in laryngeal mask airways. Anaesthesia. 2012;67:1375–85.PubMedCrossRef
8.
Zurück zum Zitat Higgs A, McGrath BA, Goddard C, et al. Guidelines for the management of tracheal intubation in critically ill adults. Br J Anaesth. 2018;120:323–52.CrossRefPubMed Higgs A, McGrath BA, Goddard C, et al. Guidelines for the management of tracheal intubation in critically ill adults. Br J Anaesth. 2018;120:323–52.CrossRefPubMed
10.
Zurück zum Zitat Cook TM, Kelly FE. Time to abandon the ‘vintage’ laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice. Br J Anaesth. 2015;115:497–9.PubMedCrossRef Cook TM, Kelly FE. Time to abandon the ‘vintage’ laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice. Br J Anaesth. 2015;115:497–9.PubMedCrossRef
11.
Zurück zum Zitat Higgs A, McGrath BA, Goddard C, et al. DAS guidelines on the airway management of critically ill patients. Anaesthesia. 2018;73:1035–6.PubMedCrossRef Higgs A, McGrath BA, Goddard C, et al. DAS guidelines on the airway management of critically ill patients. Anaesthesia. 2018;73:1035–6.PubMedCrossRef
12.
Zurück zum Zitat Pandit JJ, Irwin MG. Airway management in critical illness: practice implications of new Difficult Airway Society guidelines. Anaesthesia. 2018;73:544–8.PubMedCrossRef Pandit JJ, Irwin MG. Airway management in critical illness: practice implications of new Difficult Airway Society guidelines. Anaesthesia. 2018;73:544–8.PubMedCrossRef
13.
Zurück zum Zitat Brimacombe JR. Laryngeal mask anesthesia—principles and practice. 2nd ed. London, UK: Saunders; 2005. Brimacombe JR. Laryngeal mask anesthesia—principles and practice. 2nd ed. London, UK: Saunders; 2005.
14.
Zurück zum Zitat Danha RF, Thompson JL, Popat MT, Pandit JJ. Comparison of fibreoptic-guided orotracheal intubation through classic and single-use laryngeal mask airways. Anaesthesia. 2005;60:184–8.PubMedCrossRef Danha RF, Thompson JL, Popat MT, Pandit JJ. Comparison of fibreoptic-guided orotracheal intubation through classic and single-use laryngeal mask airways. Anaesthesia. 2005;60:184–8.PubMedCrossRef
15.
Zurück zum Zitat Nair I, Bailey PM. Use of the laryngeal mask for airway maintenance following tracheal extubation. Anaesthesia. 1995;50:174–5.PubMedCrossRef Nair I, Bailey PM. Use of the laryngeal mask for airway maintenance following tracheal extubation. Anaesthesia. 1995;50:174–5.PubMedCrossRef
16.
Zurück zum Zitat Sorbello M, Cortese G, Gaçonnet C, Skinner M. A modified Bailey's manoeuvre for supraglottic airway continuum using LMA Protector™. Indian J Anaesth. 2019;63:78–80.PubMedPubMedCentralCrossRef Sorbello M, Cortese G, Gaçonnet C, Skinner M. A modified Bailey's manoeuvre for supraglottic airway continuum using LMA Protector™. Indian J Anaesth. 2019;63:78–80.PubMedPubMedCentralCrossRef
17.
Zurück zum Zitat Tanoubi I, Sun JN, Drolet P, Fortier LP, Donati F. Replacing a double-lumen tube with a single-lumen tube or a laryngeal mask airway device to reduce coughing at emergence after thoracic surgery: a randomized controlled single-blind trial. Can J Anesth. 2015;62:988–95.PubMedCrossRef Tanoubi I, Sun JN, Drolet P, Fortier LP, Donati F. Replacing a double-lumen tube with a single-lumen tube or a laryngeal mask airway device to reduce coughing at emergence after thoracic surgery: a randomized controlled single-blind trial. Can J Anesth. 2015;62:988–95.PubMedCrossRef
18.
Zurück zum Zitat Suppiah RK, Rajan S, Paul J, Kumar L. Respiratory and hemodynamic outcomes following exchange extubation with laryngeal mask airway as compared to traditional awake extubation. Anesth Essays Res. 2016;10:212–7.PubMedPubMedCentralCrossRef Suppiah RK, Rajan S, Paul J, Kumar L. Respiratory and hemodynamic outcomes following exchange extubation with laryngeal mask airway as compared to traditional awake extubation. Anesth Essays Res. 2016;10:212–7.PubMedPubMedCentralCrossRef
19.
Zurück zum Zitat Länkimäki S, Alahuhta S, Silfvast T, Kurola J. Feasability of LMA Supreme for airway management in unconscious patients by ALS paramedics. Scand J Trauma, Resus Emerg Med. 2015;23:24.CrossRef Länkimäki S, Alahuhta S, Silfvast T, Kurola J. Feasability of LMA Supreme for airway management in unconscious patients by ALS paramedics. Scand J Trauma, Resus Emerg Med. 2015;23:24.CrossRef
20.
Zurück zum Zitat Frerk C, Mitchell VS, McNarry AF, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:827–48.PubMedPubMedCentralCrossRef Frerk C, Mitchell VS, McNarry AF, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:827–48.PubMedPubMedCentralCrossRef
21.
Zurück zum Zitat Marshall SD, Pandit JJ. Radical evolution: the 2015 Difficult Airway Society guidelines for managing unanticipated difficult or failed tracheal intubation. Anaesthesia. 2016;71:131–7.PubMedCrossRef Marshall SD, Pandit JJ. Radical evolution: the 2015 Difficult Airway Society guidelines for managing unanticipated difficult or failed tracheal intubation. Anaesthesia. 2016;71:131–7.PubMedCrossRef
23.
Zurück zum Zitat Apfelbaum JL, Hagberg CA, Caplan RA, et al. Committee on standards and practice parameters. Practice guidelines for management of the difficult airway: an updated Report by the American Society of Anesthesiologists task force on management of the difficult airway. Anesthesiology. 2013;118:251–70.PubMedCrossRef Apfelbaum JL, Hagberg CA, Caplan RA, et al. Committee on standards and practice parameters. Practice guidelines for management of the difficult airway: an updated Report by the American Society of Anesthesiologists task force on management of the difficult airway. Anesthesiology. 2013;118:251–70.PubMedCrossRef
24.
Zurück zum Zitat Batuwitage B, Charters P. Postoperative management of the difficult airway. Br J Anaesth Educ. 2017;17:235–41. Batuwitage B, Charters P. Postoperative management of the difficult airway. Br J Anaesth Educ. 2017;17:235–41.
25.
Zurück zum Zitat Panjwani S, Seymour P, Pandit JJ. A manoeuvre for using the flexible fibreoptic bronchoscope through the Intubating Laryngeal Mask Airway. Anaesthesia. 2001;56:696–7.PubMedCrossRef Panjwani S, Seymour P, Pandit JJ. A manoeuvre for using the flexible fibreoptic bronchoscope through the Intubating Laryngeal Mask Airway. Anaesthesia. 2001;56:696–7.PubMedCrossRef
26.
Zurück zum Zitat Van Zundert TC, Hendrickx JF, De Witte JL, Wong DT, Cattano D, Brimacombe JR. Do mask aperture bars of extraglottic airway devices prevent prolapse of epiglottis causing airway obstruction? A randomized crossover trial in anesthetized adult patients. J Clin Anesth. 2016;31:231–7.PubMedCrossRef Van Zundert TC, Hendrickx JF, De Witte JL, Wong DT, Cattano D, Brimacombe JR. Do mask aperture bars of extraglottic airway devices prevent prolapse of epiglottis causing airway obstruction? A randomized crossover trial in anesthetized adult patients. J Clin Anesth. 2016;31:231–7.PubMedCrossRef
27.
Zurück zum Zitat Cook T, Howes B. Supraglottic airway devices: recent advances. Cont Educ Anaesthesia, Critical Care & Pain. 2011;11:56–61.CrossRef Cook T, Howes B. Supraglottic airway devices: recent advances. Cont Educ Anaesthesia, Critical Care & Pain. 2011;11:56–61.CrossRef
28.
Zurück zum Zitat Rosenberg MB, Phero JC, Becker DE. Essentials of airway management, oxygenation and ventilation: part 2: advanced airway devices: supraglottic airways. Anesth Prog. 2014;61:113–8.PubMedPubMedCentralCrossRef Rosenberg MB, Phero JC, Becker DE. Essentials of airway management, oxygenation and ventilation: part 2: advanced airway devices: supraglottic airways. Anesth Prog. 2014;61:113–8.PubMedPubMedCentralCrossRef
29.
Zurück zum Zitat Verghese C, Mena G, Ferson DZ, Brain AIJ. Laryngeal mask airway. In: Hagberg CA, editor. Benumof and Hagberg’s Airway Management. 4th ed. Philadelphia: Elsevier Saunders; 2017. p. 470. Verghese C, Mena G, Ferson DZ, Brain AIJ. Laryngeal mask airway. In: Hagberg CA, editor. Benumof and Hagberg’s Airway Management. 4th ed. Philadelphia: Elsevier Saunders; 2017. p. 470.
30.
Zurück zum Zitat Van Zundert AA, Kumar CM, Van Zundert TC. Malpositioning of supraglottic airway devices: preventive and corrective strategies. Br J Anaesth. 2016;116:579–82.PubMedCrossRef Van Zundert AA, Kumar CM, Van Zundert TC. Malpositioning of supraglottic airway devices: preventive and corrective strategies. Br J Anaesth. 2016;116:579–82.PubMedCrossRef
35.
Zurück zum Zitat Terblanche NCS, Middleton C, Choi-Lundberg DL, Skinner M. Efficacy of a new dual channel laryngeal mask airway, the LMA®-Gastro™ Airway, for upper gastrointestinal endoscopy: a prospective observational study. Br J Anaesth. 2018;120:353–60.PubMedCrossRef Terblanche NCS, Middleton C, Choi-Lundberg DL, Skinner M. Efficacy of a new dual channel laryngeal mask airway, the LMA®-Gastro™ Airway, for upper gastrointestinal endoscopy: a prospective observational study. Br J Anaesth. 2018;120:353–60.PubMedCrossRef
36.
Zurück zum Zitat Kuzhively J, Pandit JJ. Anesthesia and airway management for gastrointestinal endoscopic procedures outside the operating room. Curr Opin Anesthesiol. 2019;32:517–22.CrossRef Kuzhively J, Pandit JJ. Anesthesia and airway management for gastrointestinal endoscopic procedures outside the operating room. Curr Opin Anesthesiol. 2019;32:517–22.CrossRef
37.
Zurück zum Zitat Wafai Y, Salem MR, Baraka A, Joseph NJ, Czinn EA, Paulissian R. Effectiveness of the self-inflating bulb for verification of proper placement of the esophageal tracheal Combitube®. Anesth Analg. 1995;80:122–6.PubMed Wafai Y, Salem MR, Baraka A, Joseph NJ, Czinn EA, Paulissian R. Effectiveness of the self-inflating bulb for verification of proper placement of the esophageal tracheal Combitube®. Anesth Analg. 1995;80:122–6.PubMed
38.
Zurück zum Zitat Dimitriou V, Voyagis GS. Use of a prototype flexible lighted catheter for guided tracheal intubation through the intubating laryngeal mask. Anesth Analg. 1999;89:257–8.PubMed Dimitriou V, Voyagis GS. Use of a prototype flexible lighted catheter for guided tracheal intubation through the intubating laryngeal mask. Anesth Analg. 1999;89:257–8.PubMed
39.
Zurück zum Zitat Christodoulou C. ProSeal Laryngeal Mask Airway foldover detection. Anesth Analg. 2004;99:12–3.CrossRef Christodoulou C. ProSeal Laryngeal Mask Airway foldover detection. Anesth Analg. 2004;99:12–3.CrossRef
40.
Zurück zum Zitat Brimacombe J, Keller C, Berry A, Mitchell S. Assessing ProSeal laryngeal mask positioning: the suprasternal notch test. Anesth Analg. 2002;94:1366.CrossRef Brimacombe J, Keller C, Berry A, Mitchell S. Assessing ProSeal laryngeal mask positioning: the suprasternal notch test. Anesth Analg. 2002;94:1366.CrossRef
41.
Zurück zum Zitat O’Connor CJ, Borromeo CJ, Stix MS. Assessing ProSeal laryngeal mask positioning: the suprasternal notch test. Anesth Analg. 2002;94:1365–6.CrossRef O’Connor CJ, Borromeo CJ, Stix MS. Assessing ProSeal laryngeal mask positioning: the suprasternal notch test. Anesth Analg. 2002;94:1365–6.CrossRef
42.
Zurück zum Zitat O’Connor CJ Jr, Davies SR, Stix MS. “Soap bubbles” and “gauze tread” drain tube tests. Anesth Analg. 2001;93:1082.PubMedCrossRef O’Connor CJ Jr, Davies SR, Stix MS. “Soap bubbles” and “gauze tread” drain tube tests. Anesth Analg. 2001;93:1082.PubMedCrossRef
43.
Zurück zum Zitat Wardle D. Failed gastric tube insertion in the LMA-ProSeal®. Anaesthesia. 2004;59:827–8.CrossRef Wardle D. Failed gastric tube insertion in the LMA-ProSeal®. Anaesthesia. 2004;59:827–8.CrossRef
44.
Zurück zum Zitat Stix MS, O'Connor CJ Jr. Maximum minute ventilation test for the ProSeal laryngeal mask airway. Anesth Analg. 2002;95:1782–7.PubMedCrossRef Stix MS, O'Connor CJ Jr. Maximum minute ventilation test for the ProSeal laryngeal mask airway. Anesth Analg. 2002;95:1782–7.PubMedCrossRef
45.
Zurück zum Zitat Shorten GD, Opie NJ, Graziotti P, Morris I, Khangure M. Assessment of upper airway anatomy in awake sedated and anaesthetized patients using magnetic resonance imaging. Anaesth Intensive Care. 1994;22:165–9.PubMedCrossRef Shorten GD, Opie NJ, Graziotti P, Morris I, Khangure M. Assessment of upper airway anatomy in awake sedated and anaesthetized patients using magnetic resonance imaging. Anaesth Intensive Care. 1994;22:165–9.PubMedCrossRef
46.
Zurück zum Zitat Brimacombe JR. Laryngeal Mask Anesthesia – Principles and Practice. 2nd ed. Philadelphia: Saunders; 2005. p. 97–9. Brimacombe JR. Laryngeal Mask Anesthesia – Principles and Practice. 2nd ed. Philadelphia: Saunders; 2005. p. 97–9.
47.
Zurück zum Zitat Aoyama K, Takenaka I, Sata T, Shigematsu A. The triple airway manoeuvre for insertion of the laryngeal mask airway in paralyzed patients. Can J Anaesth. 1995;42:1010–6.PubMedCrossRef Aoyama K, Takenaka I, Sata T, Shigematsu A. The triple airway manoeuvre for insertion of the laryngeal mask airway in paralyzed patients. Can J Anaesth. 1995;42:1010–6.PubMedCrossRef
48.
Zurück zum Zitat Moustafa MA, Abdelhady MM. Fiberoptic assessment of the laryngeal mask airway (LarySeal) position after one hour of positive pressure ventilation: an observational study. J Clin Anesth. 2014;26:480–4.PubMedCrossRef Moustafa MA, Abdelhady MM. Fiberoptic assessment of the laryngeal mask airway (LarySeal) position after one hour of positive pressure ventilation: an observational study. J Clin Anesth. 2014;26:480–4.PubMedCrossRef
49.
Zurück zum Zitat Joshi S, Sciacca RR, Solanki DR, Young WL, Mathru MM. A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology. 1998;89:1141–6.PubMedCrossRef Joshi S, Sciacca RR, Solanki DR, Young WL, Mathru MM. A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology. 1998;89:1141–6.PubMedCrossRef
50.
Zurück zum Zitat Payne J. The use of the fibreoptic laryngoscope to confirm the position of the laryngeal mask. Anaesthesia. 1989;44:865.CrossRef Payne J. The use of the fibreoptic laryngoscope to confirm the position of the laryngeal mask. Anaesthesia. 1989;44:865.CrossRef
51.
Zurück zum Zitat Song K, Yi J, Liu W, Huang S, Huang Y. Confirmation of laryngeal mask airway placement by ultrasound examination: a pilot study. J Clin Anesth. 2016;34:638–46.PubMedCrossRef Song K, Yi J, Liu W, Huang S, Huang Y. Confirmation of laryngeal mask airway placement by ultrasound examination: a pilot study. J Clin Anesth. 2016;34:638–46.PubMedCrossRef
52.
Zurück zum Zitat Kim J, Kim JY, Kim WO, Kil HK. An ultrasound evaluation of laryngeal mask airway position in pediatric patients: an observational study. Anesth Analg. 2015;120:427–32.PubMedCrossRef Kim J, Kim JY, Kim WO, Kil HK. An ultrasound evaluation of laryngeal mask airway position in pediatric patients: an observational study. Anesth Analg. 2015;120:427–32.PubMedCrossRef
53.
Zurück zum Zitat Pandit JJ. If it hasn't failed, does it work? On 'the worst we can expect' from observational trial results, with reference to airway management devices. Anaesthesia. 2012;67:578–83.PubMedCrossRef Pandit JJ. If it hasn't failed, does it work? On 'the worst we can expect' from observational trial results, with reference to airway management devices. Anaesthesia. 2012;67:578–83.PubMedCrossRef
54.
Zurück zum Zitat Zaballos M, Zaballos J, López S, et al. The LMA® ProtectorTM in anaesthetised, non-paralysed patients: a multicentre prospective observational study. Anaesthesia. 2019;74:333–9.CrossRef Zaballos M, Zaballos J, López S, et al. The LMA® ProtectorTM in anaesthetised, non-paralysed patients: a multicentre prospective observational study. Anaesthesia. 2019;74:333–9.CrossRef
55.
Zurück zum Zitat Van Zundert AAJ, Gatt SP, Kumar CM, Van Zundert TCRV, Pandit JJ. ‘Failed supraglottic airway’: an algorithm for suboptimally placed supraglottic airway devices based on videolaryngoscopy. Br J Anaesth. 2017;118:645–9.PubMedCrossRef Van Zundert AAJ, Gatt SP, Kumar CM, Van Zundert TCRV, Pandit JJ. ‘Failed supraglottic airway’: an algorithm for suboptimally placed supraglottic airway devices based on videolaryngoscopy. Br J Anaesth. 2017;118:645–9.PubMedCrossRef
56.
Zurück zum Zitat Van Zundert AAJ, Gatt SP, Kumar CM, Van Zundert TCRV. Vision-guided placement of supraglottic airway device prevents airway obstruction: a prospective audit. Br J Anaesth. 2017;118:462–3.PubMedCrossRef Van Zundert AAJ, Gatt SP, Kumar CM, Van Zundert TCRV. Vision-guided placement of supraglottic airway device prevents airway obstruction: a prospective audit. Br J Anaesth. 2017;118:462–3.PubMedCrossRef
58.
Zurück zum Zitat Wong DT, Tam AD, Mehta V, Raveendran R, Riad W, Chung FF. New supraglottic airway with built-in pressure indicator decreases postoperative pharyngolaryngeal symptoms: a randomized controlled trial. Can J Anaesth. 2013;60:1197–203.PubMedCrossRef Wong DT, Tam AD, Mehta V, Raveendran R, Riad W, Chung FF. New supraglottic airway with built-in pressure indicator decreases postoperative pharyngolaryngeal symptoms: a randomized controlled trial. Can J Anaesth. 2013;60:1197–203.PubMedCrossRef
59.
Zurück zum Zitat Checketts MR, Alladi R, Ferguson K, et al. Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland. Anaesthesia. 2016;71:85–93.CrossRefPubMed Checketts MR, Alladi R, Ferguson K, et al. Recommendations for standards of monitoring during anaesthesia and recovery 2015: Association of Anaesthetists of Great Britain and Ireland. Anaesthesia. 2016;71:85–93.CrossRefPubMed
60.
Zurück zum Zitat Hensel M, Schmidbauer W, Geppert D, Sehner S, Bogush G, Kerner T. Overinflation of the cuff and pressure on the neck reduce the preventive effect of supraglottic airways on pulmonary aspiration: an experimental study in human cadavers. Br J Anaesth. 2016;116:289–94.PubMedCrossRef Hensel M, Schmidbauer W, Geppert D, Sehner S, Bogush G, Kerner T. Overinflation of the cuff and pressure on the neck reduce the preventive effect of supraglottic airways on pulmonary aspiration: an experimental study in human cadavers. Br J Anaesth. 2016;116:289–94.PubMedCrossRef
61.
Zurück zum Zitat Heir JS, Guo SL, Purugganan R, et al. A randomized controlled study of the use of video double-lumen endobronchial tubes versus double-lumen endobronchial tubes in thoracic surgery. J Cardiothorac Vasc Anesth. 2018;32:267–74.PubMedCrossRef Heir JS, Guo SL, Purugganan R, et al. A randomized controlled study of the use of video double-lumen endobronchial tubes versus double-lumen endobronchial tubes in thoracic surgery. J Cardiothorac Vasc Anesth. 2018;32:267–74.PubMedCrossRef
62.
Zurück zum Zitat Apfelbaum JL, Rupp SM, Tung A, Connis RT, Grant MD, Practice MJB. Guidelines for Central Venous Access 2020. An updated report by the American Society of Anesthesiologists Task Force on Central Venous Access. Anesthesiology. 2020;2020(132):8–43. Apfelbaum JL, Rupp SM, Tung A, Connis RT, Grant MD, Practice MJB. Guidelines for Central Venous Access 2020. An updated report by the American Society of Anesthesiologists Task Force on Central Venous Access. Anesthesiology. 2020;2020(132):8–43.
63.
Zurück zum Zitat Lewis SR, Price A, Walker KJ, et al. Ultrasound guidance for upper and lower limb blocks. Cochrane Database Syst Rev. 2015;9:CD006459. Lewis SR, Price A, Walker KJ, et al. Ultrasound guidance for upper and lower limb blocks. Cochrane Database Syst Rev. 2015;9:CD006459.
64.
Zurück zum Zitat Sites BD, Chan VW, Neal JM, et al. The American Society of Regional Anesthesia and Pain Medicine and the European Society of Regional Anaesthesia and Pain Therapy Joint Committee Recommendations for education and training in ultrasound-guided regional anesthesia. Reg Anesth Pain Med. 2010;35:S74–80.PubMedCrossRef Sites BD, Chan VW, Neal JM, et al. The American Society of Regional Anesthesia and Pain Medicine and the European Society of Regional Anaesthesia and Pain Therapy Joint Committee Recommendations for education and training in ultrasound-guided regional anesthesia. Reg Anesth Pain Med. 2010;35:S74–80.PubMedCrossRef
69.
Zurück zum Zitat Liu EHC, Goy RWL, Chen FG. The LMA CTrach™, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients. Br J Anaesth. 2006;96:396–400PubMedCrossRef Liu EHC, Goy RWL, Chen FG. The LMA CTrach™, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients. Br J Anaesth. 2006;96:396–400PubMedCrossRef
70.
Zurück zum Zitat Gomez-Rios MA, Freire-Vila E, Vizcaino-Martinez L, Estevez-Gonzalez E. The Totaltrack: an initial evaluation. Br J Anaesth. 2015;115:798–9.CrossRef Gomez-Rios MA, Freire-Vila E, Vizcaino-Martinez L, Estevez-Gonzalez E. The Totaltrack: an initial evaluation. Br J Anaesth. 2015;115:798–9.CrossRef
Metadaten
Titel
The case for a 3rd generation supraglottic airway device facilitating direct vision placement
verfasst von
André A. J. Van Zundert
Chandra M. Kumar
Tom C. R. V. Van Zundert
Stephen P. Gatt
Jaideep J. Pandit
Publikationsdatum
15.06.2020
Verlag
Springer Netherlands
Schlagwort
COVID-19
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 2/2021
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00537-4

Weitere Artikel der Ausgabe 2/2021

Journal of Clinical Monitoring and Computing 2/2021 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.