Skip to main content
main-content

01.07.2010 | Ausgabe 7/2010

Surgical Endoscopy 7/2010

Creation of pneumoperitoneum: noninvasive monitoring of clinical effects of elevated intraperitoneal pressure for the insertion of the first trocar

Zeitschrift:
Surgical Endoscopy > Ausgabe 7/2010
Autoren:
Octávio Henrique Mendes Hypólito, João Luiz Moreira Coutinho Azevedo, Fabiana Mara Scarpelli de Lima Alvarenga Caldeira, Otávio Cansanção de Azevedo, Susana Abe Miyahira, Gustavo Peixoto Soares Miguel, Otávio Monteiro Becker Jr., Afonso Cesar Cabral Guedes Machado, Gilberto Pinheiro Nunes Filho, Glícia Cansanção Azevedo

Abstract

Aim

The aim of this work is to analyze, by means of noninvasive monitoring, the clinical effects of high intraperitoneal pressure for enough time to insert the first trocar.

Methods

Sixty-seven patients without significant lung problems were randomly divided into groups P12 (n = 30, maximum intraperitoneal pressure 12 mmHg) and P20 (n = 37, maximum intraperitoneal pressure 20 mmHg). A Veress needle was inserted into the left hypochondrium for creation of pneumoperitoneum. The parameters evaluated were heart rate (HR, in bpm), arterial oxygen saturation (SaO2, expressed as percentage of hemoglobin saturated with oxygen), end-tidal CO2 (ETCO2, in mmHg), mean arterial pressure (MAP, in mmHg), and intratracheal pressure (ITP, in cmH2O). Clinical parameters were evaluated in both groups at time point 0 (TP0, before CO2 insufflation), time point 1 (TP1, when intraperitoneal pressure of 12 mmHg was reached in both groups), time point 2 (TP2, 5 min after reaching intraperitoneal pressure of 12 mmHg in group P12 and of 20 mmHg in group P20), and time point 3 (TP3, 10 min after reaching intraperitoneal pressure of 12 mmHg in group P12 and 10 min after TP1 in group P20, when intraperitoneal pressure decreased from 20 to 12 mmHg). Values outside of the normal range or occurrence of atypical phenomena suggestive of organic disease indicated clinical changes.

Results

Statistically significant differences were observed between the two groups regarding HR, MAP, ETCO2, and ITP. No significant clinical changes were observed.

Conclusions

Transitory, high intraperitoneal pressure (20 mmHg for 5 min) for insertion of the first trocar resulted in changes in HR, MAP, ETCO2, and ITP that were within the normal range, and no adverse clinical effects were observed. Therefore, the use of transitory, high intraperitoneal pressure is recommended to prevent iatrogenic injury during blind insertion of the first trocar. Nevertheless, it is not clear that this method would be safe in patients with moderate to severe chronic obstructive pulmonary disease.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 7/2010

Surgical Endoscopy 7/2010 Zur Ausgabe
  1. Sie können e.Med Chirurgie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Chirurgie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Chirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise