Skip to main content
Erschienen in: Hernia 5/2017

Open Access 02.05.2017 | Review

Critical overview of all available animal models for abdominal wall hernia research

verfasst von: R. R. M. Vogels, R. Kaufmann, L. C. L. van den Hil, S. van Steensel, M. H. F. Schreinemacher, J. F. Lange, N. D. Bouvy

Erschienen in: Hernia | Ausgabe 5/2017

Abstract

Purpose

Since the introduction of the first prosthetic mesh for abdominal hernia repair, there has been a search for the “ideal mesh.” The use of preclinical or animal models for assessment of necessary characteristics of new and existing meshes is an indispensable part of hernia research. Unfortunately, in our experience there is a lack of consensus among different research groups on which model to use. Therefore, we hypothesized that there is a lack of comparability within published animal research on hernia surgery due to wide range in experimental setup among different research groups.

Methods

A systematic search of the literature was performed to provide a complete overview of all animal models published between 2000 and 2014. Relevant parameters on model characteristics and outcome measurement were scored on a standardized scoring sheet.

Results

Due to the wide range in different animals used, ranging from large animal models like pigs to rodents, we decided to limit the study to 168 articles concerning rat models. Within these rat models, we found wide range of baseline animal characteristics, operation techniques, and outcome measurements. Making reliable comparison of results among these studies is impossible.

Conclusion

There is a lack of comparability among experimental hernia research, limiting the impact of this experimental research. We therefore propose the establishment of guidelines for experimental hernia research by the EHS.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1007/​s10029-017-1605-z) contains supplementary material, which is available to authorized users.
R. R. M. Vogels and R. Kaufmann contributed equally to this work.

Introduction

Ever since the introduction of the first prosthetic mesh for reinforcement of abdominal hernia repair, there has been a search for the “ideal mesh” [1, 2]. After using meshes of silver and stainless steel for decades, the first “modern” synthetic polypropylene mesh was introduced in the 1950s [13]. Today, polypropylene mesh remains the most commonly used mesh worldwide in ventral and inguinal hernia repair [1, 2]. The ideal mesh, however, still has not been developed [1, 2, 4].
The ideal mesh must be tailored to each patient’s current needs in the current clinical situation [4, 5]. In order to provide a mesh for most patients, a continuing growth in variety of mesh concepts exists. For instance, meshes of various materials (from prosthetic or biologic origin), shapes (flat mesh, plugs, and 3D meshes), heavy and low weight, and with various coatings are available. Along with this is a growing body of data on assessing the feasibility of new meshes with the ultimate goal to improve patient outcomes [6].
Even though clinical research is the best method to really assess the outcome of new mesh concepts, preclinical animal models remain necessary for the assessment of biocompatibility and strength in the long run [79]. Especially since several important mesh characteristics, such as inflammation, shrinkage, ingrowth, remodeling, and adhesion formation to the mesh, can only be researched using experimental models, patients cannot be reoperated for evaluation of these key aspects [4]. However, in order to compare studies and to reproduce them, it is important that different research groups use comparable research methods. However, in our search for hernia models in the past, we came across a wide range of different models leading to the hypothesis that there is very little comparability within published animal research on hernia surgery [10, 11]. To support this hypothesis, we hereby present a systematic review of the literature on all available animal models for hernia research between 2000 and 2014.

Materials and methods

A systematic search of the literature was performed using the “Excerpta Medica database” (Embase) and NCBI National Library of Medicine (PubMed). Search strategy was aimed at finding all literature concerning surgical meshes used for abdominal wall hernia in an animal model. Literature search was conducted as follows with aid of an experienced university librarian

Embase

(“surgical equipment”/de OR mesh*:ab,ti OR prothes*:ab,ti OR prosthet*:ab,ti) AND (herni*:ab,ti OR hernioplasty/de OR herniorrhaphy/de OR herniotomy/de OR hernia/de OR “abdominal wall hernia”/exp OR “incisional hernia”/de) AND [“experimental animal”/de OR “animal model”/de OR (vertebrate/exp NOT human/de) OR animal/de OR nonhuman/de OR rodent/exp OR (animal* OR nonhuman* OR rodent* OR rat OR rats OR mice OR mouse OR hamster* OR pigs OR porcine* OR swine* OR goat*)].

PubMed

{mesh*[tw] OR prothes*[tw] OR prosthet*[tw]) AND (herni*[tiab] OR hernia[mesh:noexp] OR Hernia, Abdominal[mesh] OR herniorrhaphy[mesh]).
AND ((animals[mesh] NOT humans[mesh]) OR (animal*[tw] OR nonhuman*[tw] OR rodent*[tw] OR rat[tw] OR rats[tw] OR mice[tw] OR mouse[tw] OR hamster*[tw] OR pigs[tw] OR porcine*[tw] OR swine*[tw] OR goat*[tw])}.

Study selection

Two independent researchers screened all titles and abstracts to select animal studies that were eligible for full-text review. Following primary screening, all full-text articles of the remaining studies were screened to identify studies using animal models aimed at mesh research.
We included all English, Dutch, and German literature using an animal model to study meshes designed for abdominal wall hernia repair published between January 01, 2000, and January 01, 2014. Clinical trials, abstracts, letters to the editor, or studies not primarily aimed at studying meshes were excluded from further analysis.

Study outcome

All included articles were read, and all relevant parameters concerning the studied animal models used were scored in a standardized scoring sheet. All scored parameters are mentioned in supplementary data (Table 1). First, parameters for the animal model were assessed, including subspecies. Sex, weight, and age of the animals were recorded when mentioned in the article. Also the use of a previously published model was scored; this was defined as a clear reference to a previously published use of the same animal model. Details of the model used were subsequently scored. This included the creation of a hernia defect and size of defect (when applicable), location of the mesh, and size of the implanted mesh. Thereafter, the use and type of control group were scored, and duration of follow-up was recorded. Finally, used outcome parameters were scored (mentioned in Table 1).
Table 1
Scoring system for animal models
Parameter
Outcome
Animal model
Pig
Rat
Mice
Rabbit
Guinea pig
Other: specify
Subspecies
Free text
Sex
Male
Female
Both
Unknown/not specified
Validated model
Yes
No (no reference to previous research)
Infection model
Yes
No
Unknown
Defect
Yes, size (cm × cm)
No
Unknown/not specified
Mesh location
Intraperitoneal
Inlay
Bridging
Subcutaneous
Preperitoneal
Unknown/not specified
Technique
Laparotomy
Laparoscopy
Other: specify
Unknown
Mesh size
Size of mesh (cm × cm)
Control group
Yes: specify
No
Unknown/not specified
Follow-up
Duration of follow-up in days (1 month is scored as 30 days)
Outcome parameters
 Mesh ingrowth
Yes
No
 Adhesion quality
Yes
No
 Adhesion quantity
Yes
No
 Mechanical testing/tensiometry
Yes
No
 Mesh shrinkage
Yes
No
 Histology
Yes
No
 Immunohistochemistry
Yes
No

Statistics

When applicable, data were tested using the statistical package for the social sciences (SPSS) version 22 for normal distribution using the Kolmogorov–Smirnov test for normality. Normally distributed data were presented as mean and standard deviation. Not normally distributed data were presented as median with range. All other data were presented as a percentage.

Results

A total of 315 articles (supplementary data) were included in this study, of which 168 studied rats (53.3%), 66 studied rabbits (21.0%), and 53 studied pigs (16.8%). The remaining studies described use of mice, guinea pigs, primates, dogs, goats, sheep, and hamster models. A representation of the amount of publications per year showed an increase in yearly publications (Fig. 1). Due to the variety in animals used, and the even larger variety in different animal models, all further analyses were performed on the 168 articles using a rat model. All other animal types were excluded from further analysis. Results are mentioned in Table 2.
Table 2
Outcome of all scored parameters
Parameter
Outcome
Animal model (%)a
Pig
16.8%
Rat
53.3%
Mice
3.5%
Rabbit
21.0%
Guinea pig
2.2%
Other
3.2%
Subspecies (%)
Wistar
46.4%
Sprague–Dawley
46.4%
Lewis
4.1%
Other
1.9%
Unspecified
1.2%
Sex (%)
Male
66.7%
Female
16.7%
Both
1.8%
Unknown/unspecified
15.4%
Reference to previously used model (%)
Yes
24.2%
No
75.8%
Number of meshes/animal (%)
1
85.1%
2
13.1%
3
0.6%
Unspecified
1.2%
Defect (%)
Yes size (cm2) mean (range)
72.0% 4.2 cm2 (0.5–18.0 cm2)
No
27.4%
Unknown
0.6%
Mesh location (%)
Intraperitoneal
23.8%
Inlay
11.9%
Bridging
20.0%
Subcutaneous
17.9%
Preperitoneal
5.4%
Unknown
11.9%
Infection model
Yes
9.5%
No
90.5%
Mesh size
Size of mesh (cm2) mean (Range)
5.76 cm2 (0.8–20 cm2)
Unspecified (% of articles)
17.3%
Control group
Yes
64.3%
Polypropylene mesh
22.6%
Sham
22.6%
Primary repair
6.6%
Other
12.5%
No/not described
35.7%
Antibiotics
Yes
7.1%
No/not described
92.9%
Analgetics
Yes
15.5%
No/not described
84.5%
Number of endpoints median (range)
2 Time-points (1–6 time-points) undefined in 1 article
Follow-up duration median (range)
28 days (6 h–365 days)
Outcome parameters used (%)
 Mesh ingrowth
 
10.1%
 Adhesions
Quality
16.1%
Quantity
10.7%
Both
24.4%
 Mechanical testing/tensiometry
 
48.2%
 Mesh shrinkage
 
17.3%
 Histology
 
81.0%
 Immunohistochemistry
 
23.2%
aFor this analysis, all animal types were scored; all other parameters only record results for rat studies

Rat models

A total of 168 articles described the use of a rat model, using a total of 9150 rats in 164 studies, 4 remaining studies did not define the amount of animals. Median number of animals used per study was 56 (range 10–218) with a median of three groups per study (mean 3.7, mode 2, range 1–20). Most articles described the use of either Sprague–Dawley (78 studies, 46.4%) or Wistar (78 studies, 46.4%); subspecies was not defined in two studies. Sex of animals was defined in 85.1% of studies with 112 (66.7%) using male rats, 28 (16.7%) female, and 3 (1.8%) using both sexes; sex was not defined in the remaining studies (14.9%). References, that indicated the use of an established and previously published model, were provided in only 24.2% of articles (41 studies). Frequently used models included those published by Alponat et al. (12 studies) [12], Peter-Puchner et al. (4 studies) [13], and Klinge et al. (3 studies) [14].

Methods

All rats underwent open surgery for mesh implantation, receiving 1 (85.1%), 2 (13.1%), or 3 (0.6%) meshes per animal. Most models included the creation of a true hernia defect model (121 articles, 72.0%), 1 study did not define the use of a defect, and the remainder (46 articles, 27.4%) did not create a hernia defect. Defect size varied between 0.5 and 18.0 cm2 with a mean of 4.2 cm2 (median 4.0, mode 6.0). Meshes were either placed as bridging within a defect (49 articles, 29.2%), intraperitoneal (40 articles, 23.8%), subcutaneous (30 articles, 17.9%), inlay (20 articles, 11.9%), or preperitoneal (9 articles, 5.4%). Mesh position was not specified in 11.9% of articles (20 studies). Models aimed at mesh infections were only used in 16 publications (9.5%).
Meshes were cut to size with a median size of 6 cm2 (mean 5.76 cm2, range 0.8–20 cm2); size of mesh was not defined in 29 articles (17.3%). Control groups were defined in 64.3% (108 articles). Most articles defined the use of a polypropylene control (including brand named polypropylene, e.g., Parietene) or sham operated animals (both 38 articles, 22.6%). Others included primary/suture repair (11 articles, 6.6%). Part of included articles compared mesh coatings instead of different meshes; this leads to uncoated meshes being control group in 17 studies (10.1%).
The use of perioperative antibiotics for infection prevention was only mentioned in 7.1% of articles (12 studies). Out of these studies, antibiotics used were from the penicillin group, gentamicin, and fluoroquinolone antibiotics (4 studies each). If animal models other than rats were added in the analysis, up to 20.6% of articles described the use of antibiotics, with cephalosporin-type antibiotics being used most.
Perioperative pain relief using analgesic medication has been mentioned in 15.5% of rat models (26 studies, versus 22.8% or 72 studies when reviewing all animal models). Within these 26 studies, opioid-type analgesics were used in majority of cases (17 articles, 10.1%), sometimes combined with NSAIDs (2 articles, 1.2%), followed by NSAID (7 articles, 4.2%) or local analgesics (5 articles, 3.0%).

Follow-up

Duration of follow-up was defined in 167 of 168 included articles. The number of endpoints ranged from 1 to 6 per article with a median of 2 time-points per article (mean 2.21, mode 1). Duration of follow-up ranged from 6 h to 365 days, with a median duration of 28 days. Time-points that were used most frequently were, respectively, 1 month (including follow-up defined as 4 weeks and 30 days), 3 months (or 90 days), and 1 or 2 weeks.

Outcome parameters

Outcome parameters were scored from all 168 articles. Histological examination of explanted meshes was performed in nearly all articles (81.0%, or 136 articles), 39 of these articles (23.2%) subsequently added immunohistochemical analysis. Strength of ingrowth was either defined as subjective macroscopic ingrowth (scored in 10.1%, 17 articles), or mechanical strength measured by tensiometry (scored in 48.2%, 81 articles). Adhesions were scored in 86 articles (51.1%), scored as adhesion quality (27 articles, 16.1%), adhesion quantity (18 articles, 10.7%), or both (41 articles, 24.4%). Mesh shrinkage was scored in only 17.3% of articles (29 articles). An analysis of the scoring systems used is presented in Table 3.
Table 3
Overview of scoring systems used
 
Different scoring systems (number of scoring systems)
Validated scoring system (number of scoring systems/% articles)a
(Semi-) quantitative or objective scoring (number of scoring systems/% articles)
New scoring system (% articles)b
Unknown or pure descriptive scoring (% of articles)
Ingrowth
12
3/5.9
4/76.4
5.9
11.8
Adhesion quality
24
19/75
16/73.5
14.7
7.3
Adhesion quantity
11
5/86.4
9/94.9
18.6
6.7
Shrinkage
9
3/89.6
29/100
20.7
0.0
Histology
47
13/47.1
7/36.8
22.8
30.1
immunohistochemistry
9
2/59.0
3/61.5
15.4
20.5
Number indicates the number of different scoring systems involved. The percentage is the percentage of articles involved
aValidated scoring system is defined as either a system with clear reference or an accepted system used in the same manner in multiple articles
bNew scoring systems are defined as scoring systems used only in one article

Discussion

Critical review of the literature revealed a large variety in mesh models; many different models, animal species, meshes, and parameters were assessed in the last decade leading to studies that were difficult to compare among each other.
Identical models including all parameters were not found to be implemented by different centers, in other words all centers apparently use their own specific models. Due to the growing variety in existing and new concepts of meshes, preclinical animal research is necessary to assess biocompatibility and effectiveness of new meshes before implementing them in clinical practice [79]. Furthermore, many of the important mesh characteristics are derived from and can only be properly researched using animal models [4]. However, for experimental research to have proper impact, research published by different research groups needs to be comparable and reproducible [3, 15].
In this study, we attempted to provide a systematic overview of all available animal models for mesh research. However, due to the large amount of different animals used we decided to focus on only one species. Although large animal models like pigs are supposed to resemble the human situation most, over 50% of all experimental hernia research focused on rat models [7, 16]. Therefore, we decided to limit this overview and only elaborate on rat models. We realize that limitation to one animal group might lead to bias in information leading to a possible underestimation or even overestimation of the problem. This could possibly be solved by using a combination of a small animal model for preliminary testing and immunohistochemistry, which might be followed by testing on a larger animal model, which will better resemble the anatomy of the human abdominal wall.
One of the first issues that needs to be addressed concerns the use of mostly young male rats. Although incisional hernias occur in both male and female patients, with some clinical studies even reporting female sex as an independent risk factor, almost all included experimental studies report the use of male rats only [17, 18]. Furthermore, more than one in every seven authors did not report the sex of the animal in their papers, even though there is an increasing amount of information on the effect of sex on the outcome [19, 20]. Therefore, we believe that in accordance to the ARRIVE guidelines and the recently published NIH policy there should be an effort to report on and also balance sex of animals in experimental hernia repair [20, 21]. Moreover, most studies rats used are of fairly young age, whereas most patients present with hernia’s later in life.
The results of our survey lead to the assumption that very few researchers make use of already published articles. Although this might be an underestimation due to the fact that not all researchers reference to previously published articles, there still seems to be a large variety in published models. This could lead to irreproducible results or results that cannot be compared between different publications [10, 11]. This also makes translation to clinical practice extremely difficult [7, 15, 16]. Hence, we think that limiting the range of mesh models to a smaller selection of models and clear referencing to standardized models could lead to increase the impact of future publications and in turn benefit hernia surgery [2224].
We believe one important factor for the choice of hernia models should be that it closely resembles the human situation and follows the guidelines for hernia repair in humans. One discrepancy between human situation and most hernia models is the “hernia age.” Most animal models described use an acute hernia model, where the defect is created in the same procedure as the mesh is placed. In the human situation, hernias take time to mature, possibly altering postoperative results. Perhaps the use of a “mature hernia” model as proposed by Dubay et al. in 2006 would better resemble the clinical situation [25]. Furthermore, following the 2014 International Endohernia Society (IEHS) guidelines IntraPeritoneal Onlay Meshes (IPOM) with closed defects should be used [26].
Another point of interest is the mesh positioning. Although some mesh positions are considered outdated in the clinical setting, there is no decrease in the use of these models over the years. To further increase the impact of the animal studies on clinical practice, it might be good to translate guidelines for human hernia surgery to preclinical animal models. In particular, the IPOM with mesh augmentation, as is advocated in the recent IEHS guidelines, is only used in less than one-fourth of published studies [26]. Furthermore, since the preclinical studies are mostly aimed at investigating host response to meshes and mesh materials, the use of a standardized control group could improve reproducibility and could help put results in perspective.
Despite official guidelines on laboratory animal welfare in both Europe and the USA requiring the use of analgesics when pain is to be expected, analgesics are only reported in a minority of studies [27, 28]. Since hernia operations can be considered major abdominal surgery, pain is to be expected and use of analgesics and the reporting on their use should be promoted according to international regulations.
Despite the heterogeneity in the included studies, there already seems to be some degree in consensus for some aspects. For instance, most authors seem to agree that the creation of an abdominal wall defect is preferred above primary closure, be it with a large range in size of defects and meshes used. There also seems to be some degree of consensus for outcome parameters, whereas majority of studies use histological analysis and adhesion scoring as primary outcome. On the other hand, up to one-fifth of these articles seem to introduce new scoring systems to evaluate these outcome measurements instead of using readily available validated methods.
Hence, we believe guidelines for publishing and reporting of experimental research for hernia research need to be put in place. Different aspects of hernia research need to be standardized in order to increase impact of experimental research. Furthermore, standardization should lead to a reduction in the discrepancy between results in animal research and clinical research, as is often seen in many fields of medicine [23, 29]. Additionally, standardization would make definitive statements on new mesh products easier, as they can easily be compared to results from well-known materials.
Furthermore, the standardization of mesh research should be extended to the industry. The current regulations for approval of a new mesh concept by the FDA require the material only to be “substantially equivalent” to readily available materials, leaving interpretation of this equivalency open to interpretation of the manufacturer [30, 31]. The manufacturer does have to compare the new device to similar devices. However, new guidance documents from the FDA do note that any change to direct or indirect tissue-contacting products should be evaluated using biocompatibility analysis. We believe there should be standardized requirements set by the hernia societies for any new hernia devices introduced on the market.
One of the limitations of this study could be the lack of information on the quality of the animal models, preferably using the ARRIVE guidelines for animal research as proposed by Kilkenny et al. in 2010 [21]. However, we believe this does not aid the aim of our study. Furthermore, we believe the quality assessment of hernia research deserves a separate review additionally assessing the implementation of the ARRIVE guidelines within the hernia research.
Therefore, following the consensus for clinical research as published by Muysoms et al., we believe guidelines and recommendations for experimental mesh research need to be put in place or at least start a discussion on the consensus within animal hernia research models [32]. We therefore propose the establishment of an EHS (European Hernia Society) chapter for experimental research.

Compliance with ethical standards

Conflict of interest

RV, RK, LH, SS, MS, JL, NB declare no conflict of interest.

Statement of human and animal rights

This article does not contain any studies with human participants or animals performed by any of the authors.
No informed consent was necessary for the study.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Anhänge

Electronic supplementary material

Below is the link to the electronic supplementary material.
Literatur
1.
Zurück zum Zitat Basile F, Biondi A, Donati M (2013) Surgical approach to abdominal wall defects: history and new trends. Int J Surg 11:S20–S23CrossRefPubMed Basile F, Biondi A, Donati M (2013) Surgical approach to abdominal wall defects: history and new trends. Int J Surg 11:S20–S23CrossRefPubMed
2.
Zurück zum Zitat Shankaran V, Weber DJ, Reed RL 2nd, Luchette FA (2011) A review of available prosthetics for ventral hernia repair. Ann Surg 253(1):16–26CrossRefPubMed Shankaran V, Weber DJ, Reed RL 2nd, Luchette FA (2011) A review of available prosthetics for ventral hernia repair. Ann Surg 253(1):16–26CrossRefPubMed
3.
Zurück zum Zitat Cobb WS, Peindl RM, Zerey M, Carbonell AM, Heniford BT (2009) Mesh terminology 101. Hernia 13(1):1–6CrossRefPubMed Cobb WS, Peindl RM, Zerey M, Carbonell AM, Heniford BT (2009) Mesh terminology 101. Hernia 13(1):1–6CrossRefPubMed
4.
Zurück zum Zitat Eriksen JR, Gogenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11(6):481–492CrossRefPubMed Eriksen JR, Gogenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11(6):481–492CrossRefPubMed
5.
Zurück zum Zitat Bilsel Y, Abci I (2012) The search for ideal hernia repair; mesh materials and types. Int J Surg 10(6):317–321CrossRefPubMed Bilsel Y, Abci I (2012) The search for ideal hernia repair; mesh materials and types. Int J Surg 10(6):317–321CrossRefPubMed
6.
Zurück zum Zitat Burger JWA, Luijendijk RW, Hop WCJ, Halm JA, Verdaasdonk EGG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Trans Meet Am Surg Assoc 240:176–183 Burger JWA, Luijendijk RW, Hop WCJ, Halm JA, Verdaasdonk EGG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Trans Meet Am Surg Assoc 240:176–183
7.
Zurück zum Zitat Bittner R, Bingener-Casey J, Dietz U, Fabian M, Ferzli GS, Fortelny RH et al (2014) Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society [IEHS])-Part 2. Surg Endosc 28(2):353–379CrossRefPubMed Bittner R, Bingener-Casey J, Dietz U, Fabian M, Ferzli GS, Fortelny RH et al (2014) Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society [IEHS])-Part 2. Surg Endosc 28(2):353–379CrossRefPubMed
8.
Zurück zum Zitat Bringman S, Conze J, Cuccurullo D, Deprest J, Junge K, Klosterhalfen B et al (2010) Hernia repair: the search for ideal meshes. Hernia 14(1):81–87CrossRefPubMed Bringman S, Conze J, Cuccurullo D, Deprest J, Junge K, Klosterhalfen B et al (2010) Hernia repair: the search for ideal meshes. Hernia 14(1):81–87CrossRefPubMed
9.
Zurück zum Zitat Schreinemacher M, Henatsch D, van Barneveld K, Bouvy N (2010) The need for standardised animal models and scoring systems in assessing mesh biocompatibility. Hernia 14(3):335–336CrossRefPubMedPubMedCentral Schreinemacher M, Henatsch D, van Barneveld K, Bouvy N (2010) The need for standardised animal models and scoring systems in assessing mesh biocompatibility. Hernia 14(3):335–336CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Deeken CR, Faucher KM, Matthews BD (2012) A review of the composition, characteristics, and effectiveness of barrier mesh prostheses utilized for laparoscopic ventral hernia repair. Surg Endosc 26(2):566–575CrossRefPubMed Deeken CR, Faucher KM, Matthews BD (2012) A review of the composition, characteristics, and effectiveness of barrier mesh prostheses utilized for laparoscopic ventral hernia repair. Surg Endosc 26(2):566–575CrossRefPubMed
11.
Zurück zum Zitat Sanders DL, Kingsnorth AN (2012) Prosthetic mesh materials used in hernia surgery. Expert Rev Med Devices 9(2):159–179CrossRefPubMed Sanders DL, Kingsnorth AN (2012) Prosthetic mesh materials used in hernia surgery. Expert Rev Med Devices 9(2):159–179CrossRefPubMed
12.
Zurück zum Zitat Alponat A, Lakshminarasappa SR, Teh M, Rajnakova A, Moochhala S, Goh PM et al (1997) Effects of physical barriers in prevention of adhesions: an incisional hernia model in rats. J Surg Res 68(2):126–132CrossRefPubMed Alponat A, Lakshminarasappa SR, Teh M, Rajnakova A, Moochhala S, Goh PM et al (1997) Effects of physical barriers in prevention of adhesions: an incisional hernia model in rats. J Surg Res 68(2):126–132CrossRefPubMed
13.
Zurück zum Zitat Petter-Puchner AH, Fortelny R, Mittermayr R, Ohlinger W, Redl H (2005) Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat. Hernia 9(4):322–329CrossRefPubMed Petter-Puchner AH, Fortelny R, Mittermayr R, Ohlinger W, Redl H (2005) Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat. Hernia 9(4):322–329CrossRefPubMed
14.
Zurück zum Zitat Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V (2002) Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. J Biomed Mater Res 63(6):765–771CrossRefPubMed Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V (2002) Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. J Biomed Mater Res 63(6):765–771CrossRefPubMed
15.
Zurück zum Zitat Kimmelman J, Mogil JS, Dirnagl U (2014) Distinguishing between exploratory and confirmatory preclinical research will improve translation. PLoS Biol 12(5):e1001863CrossRefPubMedPubMedCentral Kimmelman J, Mogil JS, Dirnagl U (2014) Distinguishing between exploratory and confirmatory preclinical research will improve translation. PLoS Biol 12(5):e1001863CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Penttinen R, Gronroos JM (2008) Mesh repair of common abdominal hernias: a review on experimental and clinical studies. Hernia 12(4):337–344CrossRefPubMed Penttinen R, Gronroos JM (2008) Mesh repair of common abdominal hernias: a review on experimental and clinical studies. Hernia 12(4):337–344CrossRefPubMed
17.
Zurück zum Zitat Itatsu K, Yokoyama Y, Sugawara G, Kubota H, Tojima Y, Kurumiya Y et al (2014) Incidence of and risk factors for incisional hernia after abdominal surgery. Br J Surg 101(11):1439–1447CrossRefPubMed Itatsu K, Yokoyama Y, Sugawara G, Kubota H, Tojima Y, Kurumiya Y et al (2014) Incidence of and risk factors for incisional hernia after abdominal surgery. Br J Surg 101(11):1439–1447CrossRefPubMed
18.
Zurück zum Zitat Sorensen LT, Hemmingsen UB, Kirkeby LT, Kallehave F, Jorgensen LN (2005) Smoking is a risk factor for incisional hernia. Arch Surg 140(2):119–123CrossRefPubMed Sorensen LT, Hemmingsen UB, Kirkeby LT, Kallehave F, Jorgensen LN (2005) Smoking is a risk factor for incisional hernia. Arch Surg 140(2):119–123CrossRefPubMed
19.
Zurück zum Zitat Beery AK, Zucker I (2011) Sex bias in neuroscience and biomedical research. Neurosci Biobehav Rev 35(3):565–572CrossRefPubMed Beery AK, Zucker I (2011) Sex bias in neuroscience and biomedical research. Neurosci Biobehav Rev 35(3):565–572CrossRefPubMed
21.
Zurück zum Zitat Kilkenny C, Browne WJ, Cuthill IC, Emerson M, Altman DG (2010) Improving bioscience research reporting: the ARRIVE guidelines for reporting animal research. PLoS Biol 8(6):e1000412CrossRefPubMedPubMedCentral Kilkenny C, Browne WJ, Cuthill IC, Emerson M, Altman DG (2010) Improving bioscience research reporting: the ARRIVE guidelines for reporting animal research. PLoS Biol 8(6):e1000412CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Henderson VC, Kimmelman J, Fergusson D, Grimshaw JM, Hackam DG (2013) Threats to validity in the design and conduct of preclinical efficacy studies: a systematic review of guidelines for in vivo animal experiments. PLoS Med 10(7):e1001489CrossRefPubMedPubMedCentral Henderson VC, Kimmelman J, Fergusson D, Grimshaw JM, Hackam DG (2013) Threats to validity in the design and conduct of preclinical efficacy studies: a systematic review of guidelines for in vivo animal experiments. PLoS Med 10(7):e1001489CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Landis SC, Amara SG, Asadullah K, Austin CP, Blumenstein R, Bradley EW et al (2012) A call for transparent reporting to optimize the predictive value of preclinical research. Nature 490(7419):187–191CrossRefPubMedPubMedCentral Landis SC, Amara SG, Asadullah K, Austin CP, Blumenstein R, Bradley EW et al (2012) A call for transparent reporting to optimize the predictive value of preclinical research. Nature 490(7419):187–191CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat DuBay DA, Wang X, Adamson B, Kuzon WM Jr, Dennis RG, Franz MG (2006) Mesh incisional herniorrhaphy increases abdominal wall elastic properties: a mechanism for decreased hernia recurrences in comparison with suture repair. Surgery 140(1):14–24CrossRefPubMed DuBay DA, Wang X, Adamson B, Kuzon WM Jr, Dennis RG, Franz MG (2006) Mesh incisional herniorrhaphy increases abdominal wall elastic properties: a mechanism for decreased hernia recurrences in comparison with suture repair. Surgery 140(1):14–24CrossRefPubMed
26.
Zurück zum Zitat Bittner R, Bingener-Casey J, Dietz U, Fabian M, Ferzli GS, Fortelny RH et al (2014) Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society (IEHS)-part 1. Surg Endosc 28(1):2–29CrossRefPubMed Bittner R, Bingener-Casey J, Dietz U, Fabian M, Ferzli GS, Fortelny RH et al (2014) Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society (IEHS)-part 1. Surg Endosc 28(1):2–29CrossRefPubMed
27.
Zurück zum Zitat Directive 2010/63/EU of the European Parliament and of the Council of 22 September 2010 on the protection of animals used for scientific purposes In: UNION TEPATCOTE, ed. 20-10-2010. Official Journal of the European Union 2010:33–79 Directive 2010/63/EU of the European Parliament and of the Council of 22 September 2010 on the protection of animals used for scientific purposes In: UNION TEPATCOTE, ed. 20-10-2010. Official Journal of the European Union 2010:33–79
28.
Zurück zum Zitat Public Health Service Policy on Humane Care and Use of Laboratory Animals In: Services USDoHaH, Health NIo, Welfare OoLA, eds. 2015 Public Health Service Policy on Humane Care and Use of Laboratory Animals In: Services USDoHaH, Health NIo, Welfare OoLA, eds. 2015
29.
Zurück zum Zitat van der Worp HB, Howells DW, Sena ES, Porritt MJ, Rewell S, O’Collins V et al (2010) Can animal models of disease reliably inform human studies? PLoS Med 7(3):e1000245CrossRefPubMedPubMedCentral van der Worp HB, Howells DW, Sena ES, Porritt MJ, Rewell S, O’Collins V et al (2010) Can animal models of disease reliably inform human studies? PLoS Med 7(3):e1000245CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Harth KC, Rosen MJ (2009) Major complications associated with xenograft biologic mesh implantation in abdominal wall reconstruction. Surg Innov 16(4):324–329CrossRefPubMed Harth KC, Rosen MJ (2009) Major complications associated with xenograft biologic mesh implantation in abdominal wall reconstruction. Surg Innov 16(4):324–329CrossRefPubMed
31.
Zurück zum Zitat Segan RD (2010) A response to “Major complications associated with xenograft biologic mesh implantation in abdominal wall reconstruction” (Harth KC, Rosen MJ. Surg Innov. 2009;16:324-329) and discussion of the MAUDE (manufacturer and user facility device experience) database, FDA regulation of biologic implants, and evidence-based medicine. Surg Innov 17(3):273–275CrossRefPubMed Segan RD (2010) A response to “Major complications associated with xenograft biologic mesh implantation in abdominal wall reconstruction” (Harth KC, Rosen MJ. Surg Innov. 2009;16:324-329) and discussion of the MAUDE (manufacturer and user facility device experience) database, FDA regulation of biologic implants, and evidence-based medicine. Surg Innov 17(3):273–275CrossRefPubMed
32.
Zurück zum Zitat Muysoms FE, Deerenberg EB, Peeters E, Agresta F, Berrevoet F, Campanelli G et al (2013) Recommendations for reporting outcome results in abdominal wall repair: results of a Consensus meeting in Palermo, Italy, 28–30 June 2012. Hernia 17(4):423–433CrossRefPubMed Muysoms FE, Deerenberg EB, Peeters E, Agresta F, Berrevoet F, Campanelli G et al (2013) Recommendations for reporting outcome results in abdominal wall repair: results of a Consensus meeting in Palermo, Italy, 28–30 June 2012. Hernia 17(4):423–433CrossRefPubMed
Metadaten
Titel
Critical overview of all available animal models for abdominal wall hernia research
verfasst von
R. R. M. Vogels
R. Kaufmann
L. C. L. van den Hil
S. van Steensel
M. H. F. Schreinemacher
J. F. Lange
N. D. Bouvy
Publikationsdatum
02.05.2017
Verlag
Springer Paris
Erschienen in
Hernia / Ausgabe 5/2017
Print ISSN: 1265-4906
Elektronische ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-017-1605-z

Weitere Artikel der Ausgabe 5/2017

Hernia 5/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.