Skip to main content
Erschienen in: European Archives of Oto-Rhino-Laryngology 8/2019

22.04.2019 | Otology

CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays

verfasst von: Thi Hau Vu, Chiara Perazzini, Mathilde Puechmaille, Aurélie Bachy, Aurélien Mulliez, Louis Boyer, Thierry Mom, Jean Gabrillargues

Erschienen in: European Archives of Oto-Rhino-Laryngology | Ausgabe 8/2019

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The advent of hybrid electro-acoustic implants requires precise positioning of the electrode-array (EA) within the cochlea. The cochlea size, that is, the length of the cochlear scala tympani, is often indirectly estimated from distance A by Escudé’s method. This technique has been confirmed by anatomical studies, in a bunch of cadaveric specimens, but it is not yet widely established in the field of computed tomography (CT). We compared cochlear duct length obtained by Escudé’s method to those directly acquired on CT images.

Materials and methods

The lengths of cochlear scala tympani were directly measured on CT scans by contouring the external cochlear wall (contouring technique-CoT). In fifteen patients implanted with a straight EA, the length of the EA and the measured length of the cochlea by the CoT were compared, to check the reliability of the CoT. Then, in 200 CT-scans, the length of the cochlear duct was measured by the CoT then compared to Escudé’s method.

Results

In the 200 CT-scans which served for cochlear length measurements, a significant variability between the cochleae were observed, as expected. At 360°, the correlation between the measurements of the length of the cochlear scala tympani between the two techniques differed, with a difference of 0.2 ± 0.7 mm at 360° (extreme: 2 mm; p < 0.001) and 2.2 ± 1.2 mm at 540° (extreme: 5.6 mm; p < 0.001).

Conclusion

The CoT can predict with accuracy the length of EA-insertion depth, more precisely than estimation methods such as Escudé’s.
Literatur
1.
Zurück zum Zitat Stakhovskaya O, Sridhar D, Bonham BH, Leake PA (2007) Frequency map for the human cochlear spiral ganglion: implications for cochlear implants. J Assoc Res Otolaryngol 8:220–233CrossRefPubMedPubMedCentral Stakhovskaya O, Sridhar D, Bonham BH, Leake PA (2007) Frequency map for the human cochlear spiral ganglion: implications for cochlear implants. J Assoc Res Otolaryngol 8:220–233CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Alexiades G, Dhanasingh A, Jolly C (2015) Method to estimate the complete and two-turn cochlear duct length. Otol Neurotol 36:904–907CrossRefPubMed Alexiades G, Dhanasingh A, Jolly C (2015) Method to estimate the complete and two-turn cochlear duct length. Otol Neurotol 36:904–907CrossRefPubMed
3.
Zurück zum Zitat Connor SEJ, Bell DJ, O’Gorman R, Fitzgerald-O’Connor A (2009) CT and MR imaging cochlear distance measurements may predict cochlear implant length required for a 360° insertion. AJNR Am J Neuroradiol 30:1425–1430CrossRefPubMed Connor SEJ, Bell DJ, O’Gorman R, Fitzgerald-O’Connor A (2009) CT and MR imaging cochlear distance measurements may predict cochlear implant length required for a 360° insertion. AJNR Am J Neuroradiol 30:1425–1430CrossRefPubMed
4.
Zurück zum Zitat Dunlap WP, Cortina JM, Vaslow JB, Burke MJ (1996) Meta-analysis of experiments with matched groups or repeated measures designs. Psychol Methods 1:170–177CrossRef Dunlap WP, Cortina JM, Vaslow JB, Burke MJ (1996) Meta-analysis of experiments with matched groups or repeated measures designs. Psychol Methods 1:170–177CrossRef
5.
Zurück zum Zitat Escudé B, James C, Deguine O et al (2006) The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurotol 11(suppl 1):27–33CrossRef Escudé B, James C, Deguine O et al (2006) The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurotol 11(suppl 1):27–33CrossRef
6.
Zurück zum Zitat James C, Albegger K, Battmer R, Burdo S, Deggouj N, Deguine O, Dillier N, Gersdorff M, Laszig R, Lenarz T, Rodriguez MM, Mondain M, Offeciers E, Macías AR, Ramsden R, Sterkers O, Von Wallenberg E, Weber B, Fraysse B (2005) Preservation of residual hearing with cochlear implantation: how and why. Acta Otolaryngol 125:481–491CrossRefPubMed James C, Albegger K, Battmer R, Burdo S, Deggouj N, Deguine O, Dillier N, Gersdorff M, Laszig R, Lenarz T, Rodriguez MM, Mondain M, Offeciers E, Macías AR, Ramsden R, Sterkers O, Von Wallenberg E, Weber B, Fraysse B (2005) Preservation of residual hearing with cochlear implantation: how and why. Acta Otolaryngol 125:481–491CrossRefPubMed
7.
Zurück zum Zitat Pelliccia P, Venail F, Bonafé A et al (2014) Cochlea size variability and implications in clinical practice. Acta Otorhinolaryngol Ital 34:42–49PubMedPubMedCentral Pelliccia P, Venail F, Bonafé A et al (2014) Cochlea size variability and implications in clinical practice. Acta Otorhinolaryngol Ital 34:42–49PubMedPubMedCentral
8.
Zurück zum Zitat Sato H, Sando I, Takahashi H (1991) Sexual dimorphism and development of the human cochlea. Computer 3-D measurement. Acta Otolaryngol 111:1037–1040CrossRefPubMed Sato H, Sando I, Takahashi H (1991) Sexual dimorphism and development of the human cochlea. Computer 3-D measurement. Acta Otolaryngol 111:1037–1040CrossRefPubMed
9.
Zurück zum Zitat Hochmair I, Hochmair E, Nopp P, Waller M, Jolly C (2015) Deep electrode insertion and sound coding in cochlear implants. Hear Res 322:14–23CrossRefPubMed Hochmair I, Hochmair E, Nopp P, Waller M, Jolly C (2015) Deep electrode insertion and sound coding in cochlear implants. Hear Res 322:14–23CrossRefPubMed
10.
Zurück zum Zitat Mori MC, Chang KW (2012) CT analysis demonstrates that cochlear height does not change with age. AJNR Am J Neuroradiol 33:119–123CrossRefPubMed Mori MC, Chang KW (2012) CT analysis demonstrates that cochlear height does not change with age. AJNR Am J Neuroradiol 33:119–123CrossRefPubMed
11.
Zurück zum Zitat Boyd PJ (2011) Potential benefits from deeply inserted cochlear implant electrodes. Ear Hear 32:411–427CrossRefPubMed Boyd PJ (2011) Potential benefits from deeply inserted cochlear implant electrodes. Ear Hear 32:411–427CrossRefPubMed
12.
13.
Zurück zum Zitat Kawano A, Seldon HL, Clark GM (1996) Computer-aided three-dimensional reconstruction in human cochlear maps: measurement of the lengths of organ of Corti, outer wall, inner wall, and Rosenthal’s canal. Ann Otol Rhinol Laryngol 105:701–709CrossRefPubMed Kawano A, Seldon HL, Clark GM (1996) Computer-aided three-dimensional reconstruction in human cochlear maps: measurement of the lengths of organ of Corti, outer wall, inner wall, and Rosenthal’s canal. Ann Otol Rhinol Laryngol 105:701–709CrossRefPubMed
14.
Zurück zum Zitat Hardy M (1938) The length of the organ of Corti in man. Am J Anat 62:291–311CrossRef Hardy M (1938) The length of the organ of Corti in man. Am J Anat 62:291–311CrossRef
15.
Zurück zum Zitat Singla A, Sahni D, Gupta AK, Aggarwal A, Gupta T (2015) Surgical anatomy of the basal turn of the human cochlea as pertaining to cochlear implantation. Otol Neurotol 36:323–328CrossRefPubMed Singla A, Sahni D, Gupta AK, Aggarwal A, Gupta T (2015) Surgical anatomy of the basal turn of the human cochlea as pertaining to cochlear implantation. Otol Neurotol 36:323–328CrossRefPubMed
16.
Zurück zum Zitat Vaid S, Vaid N (2014) Imaging for cochlear implantation: structuring a clinically relevant report. Clin Radiol 69:307–322CrossRef Vaid S, Vaid N (2014) Imaging for cochlear implantation: structuring a clinically relevant report. Clin Radiol 69:307–322CrossRef
17.
Zurück zum Zitat Buchman CA, Dillon MT, King ER, Adunka MC, Adunka OF, Pillsbury HC (2014) Influence of cochlear implant insertion depth on performance: a prospective randomized trial. Otol Neurotol 35:1773–1779CrossRefPubMed Buchman CA, Dillon MT, King ER, Adunka MC, Adunka OF, Pillsbury HC (2014) Influence of cochlear implant insertion depth on performance: a prospective randomized trial. Otol Neurotol 35:1773–1779CrossRefPubMed
18.
Zurück zum Zitat Erixon E, Rask-Andersen H (2013) How to predict cochlear length before cochlear implantation surgery. Acta Oto-Laryngol 133:1258–1265CrossRef Erixon E, Rask-Andersen H (2013) How to predict cochlear length before cochlear implantation surgery. Acta Oto-Laryngol 133:1258–1265CrossRef
19.
Zurück zum Zitat Neumann M, Aschendorff A, Schipper J, Laszig R, Klenzner T (2005) The influence of insertion depth on the preservation of residual hearing after cochlear implantation. Laryngorhinootol 84:113–116CrossRef Neumann M, Aschendorff A, Schipper J, Laszig R, Klenzner T (2005) The influence of insertion depth on the preservation of residual hearing after cochlear implantation. Laryngorhinootol 84:113–116CrossRef
20.
Zurück zum Zitat Erixon E, Högstorp H, Wadin K, Rask-Andersen H (2009) Variational anatomy of the human cochlea: implications for cochlear implantation. Otol Neurotol 30:14–22CrossRefPubMed Erixon E, Högstorp H, Wadin K, Rask-Andersen H (2009) Variational anatomy of the human cochlea: implications for cochlear implantation. Otol Neurotol 30:14–22CrossRefPubMed
21.
Zurück zum Zitat Xu J, Xu SA, Cohen LT, Clark GM (2000) Cochlear view: postoperative radiography for cochlear implantation. Am J Otol 21:49–56CrossRefPubMed Xu J, Xu SA, Cohen LT, Clark GM (2000) Cochlear view: postoperative radiography for cochlear implantation. Am J Otol 21:49–56CrossRefPubMed
22.
Zurück zum Zitat Dimopoulos P, Muren C (1990) Anatomic variations of the cochlea and relations to other temporal bone structures. Acta Radiol 31:439–444CrossRefPubMed Dimopoulos P, Muren C (1990) Anatomic variations of the cochlea and relations to other temporal bone structures. Acta Radiol 31:439–444CrossRefPubMed
23.
Zurück zum Zitat Koch RW, Ladak HM, Elfarnawany M, Agrawal SK (2017) Measuring Cochlear Duct Length—a historical analysis of methods and results. J Otolaryngol Head Neck Surg 46:19CrossRefPubMedPubMedCentral Koch RW, Ladak HM, Elfarnawany M, Agrawal SK (2017) Measuring Cochlear Duct Length—a historical analysis of methods and results. J Otolaryngol Head Neck Surg 46:19CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Deep NL, Howard BE, Holbert SO, Hoxworth JM (2017) Barrs measurement of cochlear length using the ‘A’ value for cochlea basal diameter: a feasibility study. DM Cochlear Implants Int 18:226–229CrossRef Deep NL, Howard BE, Holbert SO, Hoxworth JM (2017) Barrs measurement of cochlear length using the ‘A’ value for cochlea basal diameter: a feasibility study. DM Cochlear Implants Int 18:226–229CrossRef
25.
Zurück zum Zitat Rivas A, Cakir A, Hunter JB, Labadie RF, Zuniga MG, Wanna GB, Dawant BM, Noble JH (2017) Automatic cochlear duct length estimation for selection of cochlear implant electrode arrays. Otol Neurotol 38:339–346CrossRefPubMedPubMedCentral Rivas A, Cakir A, Hunter JB, Labadie RF, Zuniga MG, Wanna GB, Dawant BM, Noble JH (2017) Automatic cochlear duct length estimation for selection of cochlear implant electrode arrays. Otol Neurotol 38:339–346CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Meng J, Li S, Zhang F, Li Q, Qin Z (2016) Cochlear size and shape variability and implications in cochlear implantation surgery. Otol Neurotol 37:1307–1313CrossRefPubMed Meng J, Li S, Zhang F, Li Q, Qin Z (2016) Cochlear size and shape variability and implications in cochlear implantation surgery. Otol Neurotol 37:1307–1313CrossRefPubMed
27.
Zurück zum Zitat Liu YK, Qi CL, Tang J, Jiang ML, Du L, Li ZH, Tan SH, Tang AZ (2017) The diagnostic value of measurement of cochlear length and height in temporal bone CT multiplanar reconstruction of inner ear malformation. Acta Otolaryngol 137:119–126CrossRefPubMed Liu YK, Qi CL, Tang J, Jiang ML, Du L, Li ZH, Tan SH, Tang AZ (2017) The diagnostic value of measurement of cochlear length and height in temporal bone CT multiplanar reconstruction of inner ear malformation. Acta Otolaryngol 137:119–126CrossRefPubMed
29.
Zurück zum Zitat Svrakic M, Roland JT, McMenomey SO, Svirsky MA (2016) Initial operative experience and short-term hearing preservation results with a mid-scala cochlear implant electrode array. Otol Neurotol 37:1549–1554CrossRefPubMedPubMedCentral Svrakic M, Roland JT, McMenomey SO, Svirsky MA (2016) Initial operative experience and short-term hearing preservation results with a mid-scala cochlear implant electrode array. Otol Neurotol 37:1549–1554CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Buchman CA, Dillon MT, Kung ER, Adunka MC, Adunka OF, Pillsbury HC (2014) Influence of cochlear implant insertion depth on performance: a prospective randomized trial. Otol Neurotol 35:1773–1779CrossRefPubMed Buchman CA, Dillon MT, Kung ER, Adunka MC, Adunka OF, Pillsbury HC (2014) Influence of cochlear implant insertion depth on performance: a prospective randomized trial. Otol Neurotol 35:1773–1779CrossRefPubMed
31.
Zurück zum Zitat Hilly O, Smith L, Hwang E, Shipp D, Symons S, Nedzelski JM, Chen JM, Lin VY (2016) Depth of cochlear implant array within the cochlea and performance outcome. Ann Otol Rhinol Laryngol 125:886–892CrossRefPubMed Hilly O, Smith L, Hwang E, Shipp D, Symons S, Nedzelski JM, Chen JM, Lin VY (2016) Depth of cochlear implant array within the cochlea and performance outcome. Ann Otol Rhinol Laryngol 125:886–892CrossRefPubMed
32.
Zurück zum Zitat Kennedy DW (1987) Multichannel intracochlear electrodes: mechanism of insertion trauma. Laryngoscope 97:42–49PubMed Kennedy DW (1987) Multichannel intracochlear electrodes: mechanism of insertion trauma. Laryngoscope 97:42–49PubMed
33.
Zurück zum Zitat Rask-Andersen H, Liu W, Erixon E et al (2012) Human cochlea: anatomical characteristics and their relevance for cochlear implantation. Anat Rec 295:1791–1811CrossRef Rask-Andersen H, Liu W, Erixon E et al (2012) Human cochlea: anatomical characteristics and their relevance for cochlear implantation. Anat Rec 295:1791–1811CrossRef
34.
Zurück zum Zitat Kjer HM, Fagertun J, Wimmer W, Gerber N, Vera S, Barazzetti L et al (2018) Patient-specific estimation of detailed cochlear shape from clinical CT images. Int J Comput Assist Radiol Surg 13:389–396CrossRefPubMed Kjer HM, Fagertun J, Wimmer W, Gerber N, Vera S, Barazzetti L et al (2018) Patient-specific estimation of detailed cochlear shape from clinical CT images. Int J Comput Assist Radiol Surg 13:389–396CrossRefPubMed
Metadaten
Titel
CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays
verfasst von
Thi Hau Vu
Chiara Perazzini
Mathilde Puechmaille
Aurélie Bachy
Aurélien Mulliez
Louis Boyer
Thierry Mom
Jean Gabrillargues
Publikationsdatum
22.04.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 8/2019
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-019-05432-6

Weitere Artikel der Ausgabe 8/2019

European Archives of Oto-Rhino-Laryngology 8/2019 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.