Current and Future Post-Processing and Reconstruction Methods for Improved Image Quality in Coronary Computed Tomographic Angiography

verfasst von: Ryo Nakazato, Damini Dey, Troy M. LaBounty

Erschienen in: Current Cardiovascular Imaging Reports | Ausgabe 5/2012

Einloggen, um Zugang zu erhalten

Abstract

While coronary computed tomographic angiography (CCTA) has high diagnostic performance to identify and exclude obstructive coronary artery disease, it is susceptible to false-positive results and non-interpretable studies, and requires the use of ionizing radiation. New methods of image reconstruction and post-processing have the potential to significantly improve image quality, reduce the number of non-interpretable studies, and improve the diagnostic accuracy of CCTA. In this manuscript, we will review current and novel technologies for image reconstruction and post-processing that may improve the image quality of CCTA.
Literatur
1.
Zurück zum Zitat Budoff MJ, Dowe D, Jollis JG, Gitter M, Sutherland J, Halamert E, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter accuracy (assessment by coronary computed tomographic angiography of individuals undergoing invasive coronary angiography) trial. J Am Coll Cardiol. 2008;52:1724–32.PubMedCrossRef Budoff MJ, Dowe D, Jollis JG, Gitter M, Sutherland J, Halamert E, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter accuracy (assessment by coronary computed tomographic angiography of individuals undergoing invasive coronary angiography) trial. J Am Coll Cardiol. 2008;52:1724–32.PubMedCrossRef
2.
Zurück zum Zitat Miller JM, Rochitte CE, Dewey M, Arbab-Zadeh A, Niinuma H, Gottlieb I, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med. 2008;359:2324–36.PubMedCrossRef Miller JM, Rochitte CE, Dewey M, Arbab-Zadeh A, Niinuma H, Gottlieb I, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med. 2008;359:2324–36.PubMedCrossRef
3.
Zurück zum Zitat Meijboom WB, Meijs MF, Schuijf JD, Cramer MJ, Mollet NR, van Mieghem CA, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol. 2008;52:2135–44.PubMedCrossRef Meijboom WB, Meijs MF, Schuijf JD, Cramer MJ, Mollet NR, van Mieghem CA, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol. 2008;52:2135–44.PubMedCrossRef
4.
Zurück zum Zitat Redberg RF. Computed tomographic angiography: more than just a pretty picture? J Am Coll Cardiol. 2007;49:1827–9.PubMedCrossRef Redberg RF. Computed tomographic angiography: more than just a pretty picture? J Am Coll Cardiol. 2007;49:1827–9.PubMedCrossRef
5.
Zurück zum Zitat Raff GL, Abidov A, Achenbach S, Berman DS, Boxt LM, Budoff MJ, et al. SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography. J Cardiovasc Comput Tomogr. 2009;3:122–36.PubMedCrossRef Raff GL, Abidov A, Achenbach S, Berman DS, Boxt LM, Budoff MJ, et al. SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography. J Cardiovasc Comput Tomogr. 2009;3:122–36.PubMedCrossRef
6.
Zurück zum Zitat Einstein AJ. Radiation protection of patients undergoing cardiac computed tomographic angiography. JAMA. 2009;301:545–7.PubMedCrossRef Einstein AJ. Radiation protection of patients undergoing cardiac computed tomographic angiography. JAMA. 2009;301:545–7.PubMedCrossRef
7.
Zurück zum Zitat Raff GL, Chinnaiyan KM, Share DA, Goraya TY, Kazerooni EA, Moscucci M, et al. Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques. JAMA. 2009;301:2340–8.PubMedCrossRef Raff GL, Chinnaiyan KM, Share DA, Goraya TY, Kazerooni EA, Moscucci M, et al. Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques. JAMA. 2009;301:2340–8.PubMedCrossRef
8.
Zurück zum Zitat Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation. 2006;113:1305–10.PubMedCrossRef Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation. 2006;113:1305–10.PubMedCrossRef
9.
Zurück zum Zitat Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, et al. Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009;301:500–7.PubMedCrossRef Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, et al. Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009;301:500–7.PubMedCrossRef
10.
Zurück zum Zitat Nelson RC, Feuerlein S, Boll DT. New iterative reconstruction techniques for cardiovascular computed tomography: how do they work, and what are the advantages and disadvantages? J Cardiovasc Comput Tomogr. 2011;5:286–92.PubMedCrossRef Nelson RC, Feuerlein S, Boll DT. New iterative reconstruction techniques for cardiovascular computed tomography: how do they work, and what are the advantages and disadvantages? J Cardiovasc Comput Tomogr. 2011;5:286–92.PubMedCrossRef
11.
Zurück zum Zitat Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601–9.PubMedCrossRef Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601–9.PubMedCrossRef
12.
Zurück zum Zitat •• Park EA, Lee W, Kim KW, Kim KG, Thomas A, Chung JW, et al. Iterative reconstruction of dual-source coronary ct angiography: assessment of image quality and radiation dose. Int J Cardiovasc Imaging. 2011; doi:10.1007/s10554-011-0004-2. This paper evaluated the effect of iterative reconstruction on image quality and radiation dose. •• Park EA, Lee W, Kim KW, Kim KG, Thomas A, Chung JW, et al. Iterative reconstruction of dual-source coronary ct angiography: assessment of image quality and radiation dose. Int J Cardiovasc Imaging. 2011; doi:10.​1007/​s10554-011-0004-2. This paper evaluated the effect of iterative reconstruction on image quality and radiation dose.
13.
Zurück zum Zitat •• Bittencourt MS, Schmidt B, Seltmann M, Muschiol G, Ropers D, Daniel WG, et al. Iterative reconstruction in image space (iris) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging. 2011;27:1081–7. This study examined the effect of iterative reconstruction on image quality and the number of interpretable segments.PubMedCrossRef •• Bittencourt MS, Schmidt B, Seltmann M, Muschiol G, Ropers D, Daniel WG, et al. Iterative reconstruction in image space (iris) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging. 2011;27:1081–7. This study examined the effect of iterative reconstruction on image quality and the number of interpretable segments.PubMedCrossRef
14.
Zurück zum Zitat •• Renker M, Nance Jr JW, Schoepf UJ, O'Brien TX, Zwerner PL, Meyer M, et al. Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction. Radiology. 2011;260:390–9. This study evaluated the effect of iterative reconstruction on image noise and calcium blooming artifact.PubMedCrossRef •• Renker M, Nance Jr JW, Schoepf UJ, O'Brien TX, Zwerner PL, Meyer M, et al. Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction. Radiology. 2011;260:390–9. This study evaluated the effect of iterative reconstruction on image noise and calcium blooming artifact.PubMedCrossRef
15.
Zurück zum Zitat Min JK, Swaminathan RV, Vass M, Gallagher S, Weinsaft JW. High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography. J Cardiovasc Comput Tomogr. 2009;3:246–51.PubMedCrossRef Min JK, Swaminathan RV, Vass M, Gallagher S, Weinsaft JW. High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography. J Cardiovasc Comput Tomogr. 2009;3:246–51.PubMedCrossRef
16.
Zurück zum Zitat •• Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary ct angiography. AJR Am J Roentgenol. 2010;195:649–54. This manuscript evaluated the effect of iterative reconstruction on image noise, signal, and image quality.PubMedCrossRef •• Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary ct angiography. AJR Am J Roentgenol. 2010;195:649–54. This manuscript evaluated the effect of iterative reconstruction on image noise, signal, and image quality.PubMedCrossRef
17.
Zurück zum Zitat Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol. 2010;195:655–60.PubMedCrossRef Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol. 2010;195:655–60.PubMedCrossRef
18.
Zurück zum Zitat Singh S, Kalra MK, Shenoy-Bhangle AS, Saini A, Gervais DA, Westra SJ, et al. Radiation dose reduction with hybrid iterative reconstruction for pediatric CT. Radiology. 2012;263:537–46.PubMedCrossRef Singh S, Kalra MK, Shenoy-Bhangle AS, Saini A, Gervais DA, Westra SJ, et al. Radiation dose reduction with hybrid iterative reconstruction for pediatric CT. Radiology. 2012;263:537–46.PubMedCrossRef
19.
Zurück zum Zitat Sato J, Akahane M, Inano S, Terasaki M, Akai H, Katsura M, et al. Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography. Jpn J Radiol. 2012;30:146–53.PubMedCrossRef Sato J, Akahane M, Inano S, Terasaki M, Akai H, Katsura M, et al. Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography. Jpn J Radiol. 2012;30:146–53.PubMedCrossRef
20.
Zurück zum Zitat Rapalino O, Kamalian S, Payabvash S, Souza LC, Zhang D, Mukta J, et al. Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction. AJNR Am J Neuroradiol. 2012;33:609–15.PubMedCrossRef Rapalino O, Kamalian S, Payabvash S, Souza LC, Zhang D, Mukta J, et al. Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction. AJNR Am J Neuroradiol. 2012;33:609–15.PubMedCrossRef
21.
Zurück zum Zitat Noel PB, Fingerle AA, Renger B, Munzel D, Rummeny EJ, Dobritz M. Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT. AJR Am J Roentgenol. 2011;197:1404–9.PubMedCrossRef Noel PB, Fingerle AA, Renger B, Munzel D, Rummeny EJ, Dobritz M. Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT. AJR Am J Roentgenol. 2011;197:1404–9.PubMedCrossRef
22.
Zurück zum Zitat Utsunomiya D, Weigold WG, Weissman G, Taylor AJ. Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT. Eur Radiol. 2011;22:1287–94 Utsunomiya D, Weigold WG, Weissman G, Taylor AJ. Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT. Eur Radiol. 2011;22:1287–94
23.
Zurück zum Zitat Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O'Brien TX, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur Radiol. 2011;21:2130–8.PubMedCrossRef Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O'Brien TX, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur Radiol. 2011;21:2130–8.PubMedCrossRef
24.
Zurück zum Zitat Gervaise A, Osemont B, Lecocq S, Noel A, Micard E, Felblinger J, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295–301.PubMedCrossRef Gervaise A, Osemont B, Lecocq S, Noel A, Micard E, Felblinger J, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295–301.PubMedCrossRef
25.
Zurück zum Zitat Yu Z, Thibault JB, Bouman CA, Sauer KD, Hsieh J. Fast model-based X-ray CT reconstruction using spatially nonhomogeneous icd optimization. IEEE Trans Image Process. 2011;20:161–75.PubMedCrossRef Yu Z, Thibault JB, Bouman CA, Sauer KD, Hsieh J. Fast model-based X-ray CT reconstruction using spatially nonhomogeneous icd optimization. IEEE Trans Image Process. 2011;20:161–75.PubMedCrossRef
26.
Zurück zum Zitat Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007;34:4526–44.PubMedCrossRef Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007;34:4526–44.PubMedCrossRef
27.
Zurück zum Zitat Scheffel H, Stolzmann P, Schlett CL, Engel LC, Major GP, Karolyi M, et al. Coronary artery plaques: cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol. 2012;81:e363–9.PubMedCrossRef Scheffel H, Stolzmann P, Schlett CL, Engel LC, Major GP, Karolyi M, et al. Coronary artery plaques: cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol. 2012;81:e363–9.PubMedCrossRef
28.
Zurück zum Zitat Suzuki S, Machida H, Tanaka I, Ueno E. Measurement of vascular wall attenuation: comparison of ct angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro. Eur J Radiol. 2012; doi:10.1016/j.ejrad.2012.02.009 Suzuki S, Machida H, Tanaka I, Ueno E. Measurement of vascular wall attenuation: comparison of ct angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro. Eur J Radiol. 2012; doi:10.​1016/​j.​ejrad.​2012.​02.​009
29.
Zurück zum Zitat Cohen A, Yadava G, Sainath P, Fan J, Madhav P, Hsieh J. How much CT radiation dose can model based iterative reconstruction (Veo) save? A physical evaluation of the image quality using standard phantoms. Med Phys. 2011;38:3798.CrossRef Cohen A, Yadava G, Sainath P, Fan J, Madhav P, Hsieh J. How much CT radiation dose can model based iterative reconstruction (Veo) save? A physical evaluation of the image quality using standard phantoms. Med Phys. 2011;38:3798.CrossRef
30.
Zurück zum Zitat Do S, Karl WC, Liang Z, Kalra M, Brady TJ, Pien HH. A decomposition-based CT reconstruction formulation for reducing blooming artifacts. Phys Med Biol. 2011;56:7109–25.PubMedCrossRef Do S, Karl WC, Liang Z, Kalra M, Brady TJ, Pien HH. A decomposition-based CT reconstruction formulation for reducing blooming artifacts. Phys Med Biol. 2011;56:7109–25.PubMedCrossRef
31.
Zurück zum Zitat LaBounty TM, Earls JP, Leipsic J, Heilbron B, Mancini GB, Lin FY, et al. Effect of a standardized quality-improvement protocol on radiation dose in coronary computed tomographic angiography. Am J Cardiol. 2010;106:1663–7.PubMedCrossRef LaBounty TM, Earls JP, Leipsic J, Heilbron B, Mancini GB, Lin FY, et al. Effect of a standardized quality-improvement protocol on radiation dose in coronary computed tomographic angiography. Am J Cardiol. 2010;106:1663–7.PubMedCrossRef
32.
Zurück zum Zitat Abbara S, Arbab-Zadeh A, Callister TQ, Desai MY, Mamuya W, Thomson L, et al. SCCT guidelines for performance of coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr. 2009;3:190–204.PubMedCrossRef Abbara S, Arbab-Zadeh A, Callister TQ, Desai MY, Mamuya W, Thomson L, et al. SCCT guidelines for performance of coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr. 2009;3:190–204.PubMedCrossRef
33.
Zurück zum Zitat Achenbach S, Manolopoulos M, Schuhback A, Ropers D, Rixe J, Schneider C, et al. Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries. J Cardiovasc Comput Tomogr. 2012;6:91–8.PubMedCrossRef Achenbach S, Manolopoulos M, Schuhback A, Ropers D, Rixe J, Schneider C, et al. Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries. J Cardiovasc Comput Tomogr. 2012;6:91–8.PubMedCrossRef
34.
Zurück zum Zitat Isola AA, Grass M, Niessen WJ. Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac ct reconstruction. Med Phys. 2010;37:1093–109.PubMedCrossRef Isola AA, Grass M, Niessen WJ. Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac ct reconstruction. Med Phys. 2010;37:1093–109.PubMedCrossRef
35.
Zurück zum Zitat Isola AA, Ziegler A, Schafer D, Kohler T, Niessen WJ, Grass M. Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT. Comput Med Imaging Graph. 2010;34:149–59.PubMedCrossRef Isola AA, Ziegler A, Schafer D, Kohler T, Niessen WJ, Grass M. Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT. Comput Med Imaging Graph. 2010;34:149–59.PubMedCrossRef
36.
Zurück zum Zitat Isola AA, Ziegler A, Koehler T, Niessen WJ, Grass M. Motion-compensated iterative cone-beam ct image reconstruction with adapted blobs as basis functions. Phys Med Biol. 2008;53:6777–97.PubMedCrossRef Isola AA, Ziegler A, Koehler T, Niessen WJ, Grass M. Motion-compensated iterative cone-beam ct image reconstruction with adapted blobs as basis functions. Phys Med Biol. 2008;53:6777–97.PubMedCrossRef
37.
Zurück zum Zitat Isola AA, Metz CT, Schaap M, Klein S, Grass M, Niessen WJ. Cardiac motion-corrected iterative cone-beam ct reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction. Comput Med Imaging Graph. 2012;36:215–26.PubMedCrossRef Isola AA, Metz CT, Schaap M, Klein S, Grass M, Niessen WJ. Cardiac motion-corrected iterative cone-beam ct reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction. Comput Med Imaging Graph. 2012;36:215–26.PubMedCrossRef
38.
Zurück zum Zitat •• Leipsic J, Labounty T, Hague CJ, Mancini GBJ, O'brien JM, Wood DA, et al. Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications. J Cardiovasc Comput Tomogr. 2012;[in press]. This paper examined the effect of a motion-correction algorithm on interpretability, image quality, and diagnostic accuracy of CCTA. •• Leipsic J, Labounty T, Hague CJ, Mancini GBJ, O'brien JM, Wood DA, et al. Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications. J Cardiovasc Comput Tomogr. 2012;[in press]. This paper examined the effect of a motion-correction algorithm on interpretability, image quality, and diagnostic accuracy of CCTA.
39.
Zurück zum Zitat Maintz D, Seifarth H, Raupach R, Flohr T, Rink M, Sommer T, et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol. 2006;16:818–26.PubMedCrossRef Maintz D, Seifarth H, Raupach R, Flohr T, Rink M, Sommer T, et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol. 2006;16:818–26.PubMedCrossRef
40.
Zurück zum Zitat Rodriguez-Granillo GA, Rosales MA, Degrossi E, Rodriguez AE. Signal density of left ventricular myocardial segments and impact of beam hardening artifact: Implications for myocardial perfusion assessment by multidetector CT coronary angiography. Int J Cardiovasc Imaging. 2010;26:345–54.PubMedCrossRef Rodriguez-Granillo GA, Rosales MA, Degrossi E, Rodriguez AE. Signal density of left ventricular myocardial segments and impact of beam hardening artifact: Implications for myocardial perfusion assessment by multidetector CT coronary angiography. Int J Cardiovasc Imaging. 2010;26:345–54.PubMedCrossRef
41.
Zurück zum Zitat Kitagawa K, George RT, Arbab-Zadeh A, Lima JA, Lardo AC. Characterization and correction of beam-hardening artifacts during dynamic volume ct assessment of myocardial perfusion. Radiology. 2010;256:111–8.PubMedCrossRef Kitagawa K, George RT, Arbab-Zadeh A, Lima JA, Lardo AC. Characterization and correction of beam-hardening artifacts during dynamic volume ct assessment of myocardial perfusion. Radiology. 2010;256:111–8.PubMedCrossRef
42.
Zurück zum Zitat Karlsberg DW, Elad Y, Kass RM, Karlsberg RP. Quadricuspid aortic valve defined by echocardiography and cardiac computed tomography. Clin Med Insights Cardiol. 2012;6:41–4.PubMedCrossRef Karlsberg DW, Elad Y, Kass RM, Karlsberg RP. Quadricuspid aortic valve defined by echocardiography and cardiac computed tomography. Clin Med Insights Cardiol. 2012;6:41–4.PubMedCrossRef
43.
Zurück zum Zitat Meyer E, Raupach R, Lell M, Schmidt B, Kachelriess M. Frequency split metal artifact reduction (FSMAR) in computed tomography. Med Phys. 2012;39:1904–16.PubMedCrossRef Meyer E, Raupach R, Lell M, Schmidt B, Kachelriess M. Frequency split metal artifact reduction (FSMAR) in computed tomography. Med Phys. 2012;39:1904–16.PubMedCrossRef
44.
Zurück zum Zitat Habets J, Symersky P, Leiner T, de Mol BA, Mali WP, Budde RP. Artifact reduction strategies for prosthetic heart valve CT imaging. Int J Cardiovasc Imaging. 2012; doi:10.1007/s10554-012-0041-5. Habets J, Symersky P, Leiner T, de Mol BA, Mali WP, Budde RP. Artifact reduction strategies for prosthetic heart valve CT imaging. Int J Cardiovasc Imaging. 2012; doi:10.​1007/​s10554-012-0041-5.
Metadaten
Titel
Current and Future Post-Processing and Reconstruction Methods for Improved Image Quality in Coronary Computed Tomographic Angiography
verfasst von
Ryo Nakazato
Damini Dey
Troy M. LaBounty
Publikationsdatum
01.10.2012
Verlag
Current Science Inc.
Erschienen in
Current Cardiovascular Imaging Reports / Ausgabe 5/2012
Print ISSN: 1941-9066
Elektronische ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-012-9151-7

Weitere Artikel der Ausgabe 5/2012

Current Cardiovascular Imaging Reports 5/2012 Zur Ausgabe

Cardiac Computed Tomography (TC Villines and S Achenbach, Section Editors)

Imaging of Coronary Stents by Coronary CT-Angiography: Current Status

Cardiac Computed Tomography (TC Villines and S Achenbach, Section Editors)

Cardiac CT: Imaging of and Through Cardiac Devices

Cardiac Computed Tomography (TC Villines and S Achenbach, Section Editors)

Cardiac CT in Valvular Heart Disease: Current State-of-the-Art

Cardiac Computed Tomography (TC Villines and S Achenbach, Section Editors)

Imaging of Myocardial Perfusion and Late Enhancement

Cardiac Computed Tomography (TC Villines and S Achenbach, Section Editors)

Radiation Dose in Coronary CT Angiography: How High is it and What Can be Done to Keep it Low?

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.