Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 10/2013

01.10.2013 | Knee

Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes

verfasst von: M. Pietsch, O. Djahani, Ch. Zweiger, F. Plattner, R. Radl, Ch. Tschauner, S. Hofmann

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 10/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Recently, new custom-fit pin guides in total knee arthroplasty (TKA) have been introduced. Use of these guides may reduce operating time. Use of the guides combined with the absence of intramedullary alignment jigs may lead to reduced blood loss and improved early outcomes. Our aim was to evaluate blood loss and early clinical outcomes in patients undergoing minimally invasive TKA using custom-fit magnetic resonance imaging (MRI)–based pin guides.

Methods

A prospective study in 80 patients was carried out. Patients were divided randomly into 2 equal groups. In one group, intramedullary alignment jigs were used. In the second group, custom-fit MRI-based pin guides were used. All patients received the same cemented posterior-stabilized implant through a mini-midvastus approach. The volume in the drain bottles was recorded after 48 h. Hb loss was estimated by subtracting the postoperative from the preoperative Hb level. Transfusion requirements and surgical time were recorded. Outcome measures were Knee Society Scores (KSS), knee flexion, knee swelling and pain.

Results

There was lower mean drainage of blood in the custom-fit group (391 ml vs. 603 ml; p < 0.0001). There was no difference in estimated loss of Hb (3.6 g/dl vs. 4.1 g/dl; n.s.) and in transfusion requirements (7.5 % vs. 10 %; n.s.). Surgical time was reduced in the custom-fit group (12 min less; p = 0.001). KSS measured at week 2, 6 and 12 showed no significant difference between groups. Knee flexion measured on days 7, 10 and at week 6, 12 and knee swelling and pain measured on days 1, 3, 10 and at week 6, 12 showed no significant difference between groups.

Conclusions

Using custom-fit pin guides reduces blood drainage, but not the estimated Hb loss in minimally invasive TKA and does not affect transfusion rate. Surgical time is reduced. There is no effect on the early clinical outcomes.

Level of evidence

Therapeutic study, Level I.
Literatur
1.
Zurück zum Zitat Alfonso DT, Toussaint RJ, Alfonso BD et al (2006) Nonsurgical complications after total hip and knee arthroplasty. Am J Orthop (Belle Mead NJ) 35:503–510 Alfonso DT, Toussaint RJ, Alfonso BD et al (2006) Nonsurgical complications after total hip and knee arthroplasty. Am J Orthop (Belle Mead NJ) 35:503–510
2.
Zurück zum Zitat American Society of Anesthesiologists Task Force (2006) Practice guidelines for perioperative blood transfusion and adjuvant therapies: an updated report by the American society of Anesthesiologists task force on perioperative blood transfusion and adjuvant therapies. Anesthesiology 105:198–208CrossRef American Society of Anesthesiologists Task Force (2006) Practice guidelines for perioperative blood transfusion and adjuvant therapies: an updated report by the American society of Anesthesiologists task force on perioperative blood transfusion and adjuvant therapies. Anesthesiology 105:198–208CrossRef
3.
Zurück zum Zitat Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften (Germany) (2003) Stationäre und ambulante Thromboembolieprophylaxe in der Chirurgie und der perioperativen Medizin. http://www.awmf.org Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften (Germany) (2003) Stationäre und ambulante Thromboembolieprophylaxe in der Chirurgie und der perioperativen Medizin. http://​www.​awmf.​org
4.
Zurück zum Zitat Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplast 27:1149–1154CrossRef Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplast 27:1149–1154CrossRef
5.
Zurück zum Zitat Bertsch C, Holz U, Konrad G et al (2007) Early clinical outcome after navigated total knee arthroplasty. Comparison with conventional implantation in TKA: a controlled and prospective analysis. Orthopade 36:739–745PubMedCrossRef Bertsch C, Holz U, Konrad G et al (2007) Early clinical outcome after navigated total knee arthroplasty. Comparison with conventional implantation in TKA: a controlled and prospective analysis. Orthopade 36:739–745PubMedCrossRef
6.
Zurück zum Zitat Bierbaum BE, Callaghan JJ, Galante JO et al (1999) An analysis of blood management in patients having a total hip or knee arthroplasty. J Bone Jt Surg Am 81:2–10 Bierbaum BE, Callaghan JJ, Galante JO et al (1999) An analysis of blood management in patients having a total hip or knee arthroplasty. J Bone Jt Surg Am 81:2–10
7.
Zurück zum Zitat Bonutti PM, Dethmers DA, McGrath MS et al (2008) Navigation did not improve the precision of minimally invasive knee arthroplasty. Clin Orthop Relat Res 466:2730–2735PubMedCrossRef Bonutti PM, Dethmers DA, McGrath MS et al (2008) Navigation did not improve the precision of minimally invasive knee arthroplasty. Clin Orthop Relat Res 466:2730–2735PubMedCrossRef
8.
Zurück zum Zitat Brunson ME, Alexander JW (1990) Mechanisms of transfusion-induced immunosuppression. Transfusion 30:651–658PubMedCrossRef Brunson ME, Alexander JW (1990) Mechanisms of transfusion-induced immunosuppression. Transfusion 30:651–658PubMedCrossRef
9.
Zurück zum Zitat Chang CW, Wu PT, Yang CY (2010) Blood loss after minimally invasive total knee arthroplasty: effects of imageless navigation. Kaohsiung J Med Sci 26:237–243PubMedCrossRef Chang CW, Wu PT, Yang CY (2010) Blood loss after minimally invasive total knee arthroplasty: effects of imageless navigation. Kaohsiung J Med Sci 26:237–243PubMedCrossRef
10.
Zurück zum Zitat Charrois O, Kahwaji A, Vastel L et al (2001) Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis. Int Orthop 25:22–24PubMedCrossRef Charrois O, Kahwaji A, Vastel L et al (2001) Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis. Int Orthop 25:22–24PubMedCrossRef
11.
Zurück zum Zitat Cheng T, Pan XY, Mao X et al (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19:237–245PubMedCrossRef Cheng T, Pan XY, Mao X et al (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19:237–245PubMedCrossRef
12.
Zurück zum Zitat Chotanaphuti T, Ongnamthip P, Karnchanalerk K et al (2008) Comparative study between 2 cm limited quadriceps exposure minimal invasive surgery and conventional total knee arthroplasty in quadriceps function: prospective randomized controlled trial. J Med Assoc Thail 91:203–207 Chotanaphuti T, Ongnamthip P, Karnchanalerk K et al (2008) Comparative study between 2 cm limited quadriceps exposure minimal invasive surgery and conventional total knee arthroplasty in quadriceps function: prospective randomized controlled trial. J Med Assoc Thail 91:203–207
13.
Zurück zum Zitat Hasegawa M, Yoshida K, Wakabayashi H et al (2011) Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc 19:904–910PubMedCrossRef Hasegawa M, Yoshida K, Wakabayashi H et al (2011) Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc 19:904–910PubMedCrossRef
14.
Zurück zum Zitat Hinarejos P, Corrales M, Matamalas A et al (2009) Computer-assisted surgery can reduce blood loss after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:356–360PubMedCrossRef Hinarejos P, Corrales M, Matamalas A et al (2009) Computer-assisted surgery can reduce blood loss after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:356–360PubMedCrossRef
15.
Zurück zum Zitat Hitt K, Shurman JR, Greene K et al (2003) Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Jt Surg Am 85(Suppl 4):115–122 Hitt K, Shurman JR, Greene K et al (2003) Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Jt Surg Am 85(Suppl 4):115–122
16.
Zurück zum Zitat Holm B, Kristensen MT, Bencke J et al (2010) Loss of knee-extension strength is related to knee swelling after total knee arthroplasty. Arch Phys Med Rehabil 91:1770–1776PubMedCrossRef Holm B, Kristensen MT, Bencke J et al (2010) Loss of knee-extension strength is related to knee swelling after total knee arthroplasty. Arch Phys Med Rehabil 91:1770–1776PubMedCrossRef
17.
Zurück zum Zitat Howell SM, Kuznik K, Hull ML et al (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857–863PubMedCrossRef Howell SM, Kuznik K, Hull ML et al (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857–863PubMedCrossRef
18.
Zurück zum Zitat Huang HT, Su JY, Chang JK et al (2007) The early clinical outcome of minimally invasive quadriceps-sparing total knee arthroplasty: report of a 2-year follow-up. J Arthroplast 22:1007–1012CrossRef Huang HT, Su JY, Chang JK et al (2007) The early clinical outcome of minimally invasive quadriceps-sparing total knee arthroplasty: report of a 2-year follow-up. J Arthroplast 22:1007–1012CrossRef
19.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
20.
Zurück zum Zitat Kalairajah Y, Simpson D, Cossey AJ et al (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Jt Surg Br 87:1480–1482 Kalairajah Y, Simpson D, Cossey AJ et al (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Jt Surg Br 87:1480–1482
21.
Zurück zum Zitat Kerr DR, Kohan L (2008) Local infiltration analgesia: a technique for the control of acute postoperative pain following knee and hip surgery: a case study of 325 patients. Acta Orthop 79:174–183PubMedCrossRef Kerr DR, Kohan L (2008) Local infiltration analgesia: a technique for the control of acute postoperative pain following knee and hip surgery: a case study of 325 patients. Acta Orthop 79:174–183PubMedCrossRef
22.
Zurück zum Zitat Laskin RS, Beksac B, Phongjunakorn A et al (2004) Minimally invasive total knee replacement through a mini-midvastus incision: an outcome study. Clin Orthop Relat Res 428:74–81PubMedCrossRef Laskin RS, Beksac B, Phongjunakorn A et al (2004) Minimally invasive total knee replacement through a mini-midvastus incision: an outcome study. Clin Orthop Relat Res 428:74–81PubMedCrossRef
23.
Zurück zum Zitat Macfarlane AJ, Prasad GA, Chan VW et al (2009) Does regional anesthesia improve outcome after total knee arthroplasty? Clin Orthop Relat Res 467:2379–2402PubMedCrossRef Macfarlane AJ, Prasad GA, Chan VW et al (2009) Does regional anesthesia improve outcome after total knee arthroplasty? Clin Orthop Relat Res 467:2379–2402PubMedCrossRef
24.
Zurück zum Zitat Martin A, Sheinkop MB, Langhenry MM et al (2010) Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 18:359–366PubMedCrossRef Martin A, Sheinkop MB, Langhenry MM et al (2010) Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 18:359–366PubMedCrossRef
25.
26.
Zurück zum Zitat Ng VY, Declaire JH, Berend KR et al (2011) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107CrossRef Ng VY, Declaire JH, Berend KR et al (2011) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107CrossRef
27.
Zurück zum Zitat Noble JW Jr, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplast 27:153–155CrossRef Noble JW Jr, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplast 27:153–155CrossRef
28.
Zurück zum Zitat Nunley RM, Ellison BS, Ruh EL et al (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894PubMedCrossRef Nunley RM, Ellison BS, Ruh EL et al (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894PubMedCrossRef
29.
Zurück zum Zitat Pietsch M, Djahani O, Hofmann S (2007) Minimally invasive mini-midvastus approach as standard in total knee arthroplasty. Orthopade 36:1120–1128PubMedCrossRef Pietsch M, Djahani O, Hofmann S (2007) Minimally invasive mini-midvastus approach as standard in total knee arthroplasty. Orthopade 36:1120–1128PubMedCrossRef
30.
Zurück zum Zitat Rashiq S, Finegan BA (2006) The effect of spinal anesthesia on blood transfusion rate in total joint arthroplasty. Can J Surg 49:391–396PubMed Rashiq S, Finegan BA (2006) The effect of spinal anesthesia on blood transfusion rate in total joint arthroplasty. Can J Surg 49:391–396PubMed
31.
Zurück zum Zitat Rosencher N, Kerkkamp HE, Macheras G et al (2003) Orthopedic surgery transfusion hemoglobin European overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe. Transfusion 43:459–469PubMedCrossRef Rosencher N, Kerkkamp HE, Macheras G et al (2003) Orthopedic surgery transfusion hemoglobin European overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe. Transfusion 43:459–469PubMedCrossRef
32.
Zurück zum Zitat Ross M, Worrell TW (1998) Thigh and calf girth following knee injury and surgery. J Orthop Sports Phys Ther 27:9–15PubMedCrossRef Ross M, Worrell TW (1998) Thigh and calf girth following knee injury and surgery. J Orthop Sports Phys Ther 27:9–15PubMedCrossRef
33.
Zurück zum Zitat Schnurr C, Csecsei G, Eysel P et al (2010) The effect of computer navigation on blood loss and transfusion rate in TKA. Orthopedics 33:474PubMed Schnurr C, Csecsei G, Eysel P et al (2010) The effect of computer navigation on blood loss and transfusion rate in TKA. Orthopedics 33:474PubMed
34.
Zurück zum Zitat Smith TO, Hing CB (2010) Is a tourniquet beneficial in total knee replacement surgery? A meta-analysis and systematic review. Knee 17:141–147PubMedCrossRef Smith TO, Hing CB (2010) Is a tourniquet beneficial in total knee replacement surgery? A meta-analysis and systematic review. Knee 17:141–147PubMedCrossRef
35.
Zurück zum Zitat Spencer BA, Mont MA, McGrath MS et al (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571–1575PubMedCrossRef Spencer BA, Mont MA, McGrath MS et al (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571–1575PubMedCrossRef
36.
Zurück zum Zitat Thiengwittayaporn S, Junsee D, Tanavalee A (2009) A comparison of blood loss in minimally invasive surgery with and without electromagnetic computer navigation in total knee arthroplasty. J Med Assoc Thail 92(Suppl 6):27–32 Thiengwittayaporn S, Junsee D, Tanavalee A (2009) A comparison of blood loss in minimally invasive surgery with and without electromagnetic computer navigation in total knee arthroplasty. J Med Assoc Thail 92(Suppl 6):27–32
37.
Zurück zum Zitat Tria AJ Jr, Coon TM (2003) Minimal incision total knee arthroplasty: early experience. Clin Orthop Relat Res 416:185–190PubMedCrossRef Tria AJ Jr, Coon TM (2003) Minimal incision total knee arthroplasty: early experience. Clin Orthop Relat Res 416:185–190PubMedCrossRef
38.
Zurück zum Zitat Walker RH (1987) Special report: transfusion risks. Am J Clin Pathol 88:374–378PubMed Walker RH (1987) Special report: transfusion risks. Am J Clin Pathol 88:374–378PubMed
39.
Zurück zum Zitat Yue B, Varadarajan KM, Ai S et al (2011) Differences of knee anthropometry between Chinese and white men and women. J Arthroplast 26:124–130CrossRef Yue B, Varadarajan KM, Ai S et al (2011) Differences of knee anthropometry between Chinese and white men and women. J Arthroplast 26:124–130CrossRef
Metadaten
Titel
Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes
verfasst von
M. Pietsch
O. Djahani
Ch. Zweiger
F. Plattner
R. Radl
Ch. Tschauner
S. Hofmann
Publikationsdatum
01.10.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 10/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2284-z

Weitere Artikel der Ausgabe 10/2013

Knee Surgery, Sports Traumatology, Arthroscopy 10/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.