Skip to main content
Erschienen in: Lasers in Medical Science 3/2022

15.11.2021 | Original Article

Clinical performance of 6% hydrogen peroxide containing TiO2N nanoparticles activated by LED in varying wavelengths—a randomized clinical trial

verfasst von: Tamara Carolina Trevisan, Janaina Freitas Bortolatto, Giovana Rizzi, Bruna Tavoni Meloto, Andrea Abi Rached Dantas, Osmir Batista de Oliveira Junior

Erschienen in: Lasers in Medical Science | Ausgabe 3/2022

Einloggen, um Zugang zu erhalten

Abstract

This randomized, controlled, and double-blinded clinical trial evaluated the clinical performance of dental bleaching performed with 6% hydrogen peroxide containing TiO2–N nanoparticles exposed to blue and violet activation lights. Forty volunteers, selected according to the inclusion and exclusion criteria, were randomly distributed into four experimental groups (n = 10): 35% hydrogen peroxide (PH35)—control; 6% hydrogen peroxide (PH6) containing TiO2–N nanoparticles without light activation; PH6 activated with a blue LED (PH6A); and PH6 activated with a violet LED (PH6V). The three bleaching sessions consisted of 3 consecutive 16-min applications of the bleaching agent described for each group. The groups receiving LED activation were exposed to light intermittently every 1 min, with a total exposure time of 8 min in each application. Efficacy was determined by the color variation in the upper central incisors and canines, using reflectance spectroscopy analysis performed by a calibrated evaluator (ICC = 0.83). Tooth sensitivity was characterized according to the presence and intensity (SI) self-recorded in specific forms. The group treated with PH6V was as effective as the control group (PH35), whereas the groups PH6A and PH6 showed lower efficacy. Regardless of the activation, all groups treated with 6% hydrogen peroxide were less likely to cause sensitivity compared to the control group (PH35). The use pf PH6 activated by LED violet resulted in an effective and safe clinical protocol for in-office dental bleaching.
Trial registration number: RBR-8pbydg; registration date: 08/29/2017.
Literatur
1.
Zurück zum Zitat Joiner A (2006) The bleaching of teeth: a review of the literature. J Dent 34(7):412–419CrossRef Joiner A (2006) The bleaching of teeth: a review of the literature. J Dent 34(7):412–419CrossRef
2.
Zurück zum Zitat Buchalla W, Attin T (2007) External bleaching therapy with activation by heat, light or laser—a systematic review. Dent Mater 23(5):586–596CrossRef Buchalla W, Attin T (2007) External bleaching therapy with activation by heat, light or laser—a systematic review. Dent Mater 23(5):586–596CrossRef
3.
Zurück zum Zitat Yadav S (2017) Bleaching effectiveness and tooth sensitivity of inoffice hydrogen peroxide containing titanium dioxide based bleaching agent: a systematic Review. J Dent Sciences 5:69–101 Yadav S (2017) Bleaching effectiveness and tooth sensitivity of inoffice hydrogen peroxide containing titanium dioxide based bleaching agent: a systematic Review. J Dent Sciences 5:69–101
4.
Zurück zum Zitat de Souza Costa CA, Riehl H, Kina JF, Sacono NT, Hebling J (2010) Human pulp responses to in-office tooth bleaching. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109(4):59–64CrossRef de Souza Costa CA, Riehl H, Kina JF, Sacono NT, Hebling J (2010) Human pulp responses to in-office tooth bleaching. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109(4):59–64CrossRef
5.
Zurück zum Zitat Reis A, Tay LY, Herrera DR, Kossatz S, Loguercio AD (2011) Clinical effects of prolonged application time of an in-office bleaching gel. Oper Dent 36(6):590–596CrossRef Reis A, Tay LY, Herrera DR, Kossatz S, Loguercio AD (2011) Clinical effects of prolonged application time of an in-office bleaching gel. Oper Dent 36(6):590–596CrossRef
6.
Zurück zum Zitat Tay LY, Kose C, Herrera DR, Reis A, Loguercio AD (2012) Long-term efficacy of in-office and at-home bleaching: a 2-year double-blind randomized clinical trial. Am J Dent 25(4):199–204PubMed Tay LY, Kose C, Herrera DR, Reis A, Loguercio AD (2012) Long-term efficacy of in-office and at-home bleaching: a 2-year double-blind randomized clinical trial. Am J Dent 25(4):199–204PubMed
7.
Zurück zum Zitat He L-B, Shao M-Y, Tan K, Xu X, Li JY (2012) The effects of light on bleaching and tooth sensitivity during in-office vital bleaching: a systematic review and meta-analysis. J Dent 40(8):644–653CrossRef He L-B, Shao M-Y, Tan K, Xu X, Li JY (2012) The effects of light on bleaching and tooth sensitivity during in-office vital bleaching: a systematic review and meta-analysis. J Dent 40(8):644–653CrossRef
8.
Zurück zum Zitat Bonafé E, Bacovis CL, Iensen S, Loguercio AD, Reis A, Kossatz S (2013) Tooth sensitivity and efficacy of in-office bleaching in restored teeth. J Dent 41(4):363–369CrossRef Bonafé E, Bacovis CL, Iensen S, Loguercio AD, Reis A, Kossatz S (2013) Tooth sensitivity and efficacy of in-office bleaching in restored teeth. J Dent 41(4):363–369CrossRef
9.
Zurück zum Zitat Camargo SEA, Valera MC, Camargo CHR, Gasparoto Mancini MN, Menezes MM (2007) Penetration of 38% hydrogen peroxide into the pulp chamber in bovine and human teeth submitted to office bleach technique. J Endod 33(9):1074–1077CrossRef Camargo SEA, Valera MC, Camargo CHR, Gasparoto Mancini MN, Menezes MM (2007) Penetration of 38% hydrogen peroxide into the pulp chamber in bovine and human teeth submitted to office bleach technique. J Endod 33(9):1074–1077CrossRef
10.
Zurück zum Zitat Moncada G, Sepúlveda D, Elphick K, Contente M, Estay J, Bahamondes V et al (2013) Effects of light activation, agent concentration, and tooth thickness on dental sensitivity after bleaching. Oper Dent 38(5):467–476CrossRef Moncada G, Sepúlveda D, Elphick K, Contente M, Estay J, Bahamondes V et al (2013) Effects of light activation, agent concentration, and tooth thickness on dental sensitivity after bleaching. Oper Dent 38(5):467–476CrossRef
11.
Zurück zum Zitat Reis A, Kossatz S, Martins GC, Loguercio AD (2013) Efficacy of and effect on tooth sensitivity of in-office bleaching gel concentrations: a randomized clinical trial. Oper Dent 38(4):386–393CrossRef Reis A, Kossatz S, Martins GC, Loguercio AD (2013) Efficacy of and effect on tooth sensitivity of in-office bleaching gel concentrations: a randomized clinical trial. Oper Dent 38(4):386–393CrossRef
12.
Zurück zum Zitat Bortolatto JF, Pretel H, Floros MC, Luizzi ACC, Dantas AAR, Fernandez E et al (2014) Low concentration H2O2/TiO_N in office bleaching: a randomized clinical trial. J Dent Res 93:66S-71SCrossRef Bortolatto JF, Pretel H, Floros MC, Luizzi ACC, Dantas AAR, Fernandez E et al (2014) Low concentration H2O2/TiO_N in office bleaching: a randomized clinical trial. J Dent Res 93:66S-71SCrossRef
13.
Zurück zum Zitat Martín J, Vildósola P, Bersezio C, Herrera A, Bortolatto J, Saad JRC et al (2015) Effectiveness of 6% hydrogen peroxide concentration for tooth bleaching - a double-blind, randomized clinical trial. J Dent 43(8):965–972CrossRef Martín J, Vildósola P, Bersezio C, Herrera A, Bortolatto J, Saad JRC et al (2015) Effectiveness of 6% hydrogen peroxide concentration for tooth bleaching - a double-blind, randomized clinical trial. J Dent 43(8):965–972CrossRef
14.
Zurück zum Zitat Bortolatto JF, Trevisan TC, Bernardi PSI, Fernandez E, Dovigo LN, Loguercio AD et al (2016) A novel approach for in-office tooth bleaching with 6 % H2O2/TiO_N and LED/laser system—a controlled, triple-blinded, randomized clinical trial. Lasers Med Sci 31(3):437–444CrossRef Bortolatto JF, Trevisan TC, Bernardi PSI, Fernandez E, Dovigo LN, Loguercio AD et al (2016) A novel approach for in-office tooth bleaching with 6 % H2O2/TiO_N and LED/laser system—a controlled, triple-blinded, randomized clinical trial. Lasers Med Sci 31(3):437–444CrossRef
15.
Zurück zum Zitat Dias HB, Carrera ET, Bortollato JF, de Andrade MF, Rastelli ANS (2016) LED and low level laser therapy association in tooth bleaching using a novel low concentration H2O2/N-doped TiO2 bleaching agent. Laser Phys 26:1–8CrossRef Dias HB, Carrera ET, Bortollato JF, de Andrade MF, Rastelli ANS (2016) LED and low level laser therapy association in tooth bleaching using a novel low concentration H2O2/N-doped TiO2 bleaching agent. Laser Phys 26:1–8CrossRef
16.
Zurück zum Zitat Asahi R, Morikawa T, Ohwaki T, Aoki K, Taga Y (2001) Visible-light photocatalysis in nitrogen-dopedtitanium oxides. Science 293:269–271CrossRef Asahi R, Morikawa T, Ohwaki T, Aoki K, Taga Y (2001) Visible-light photocatalysis in nitrogen-dopedtitanium oxides. Science 293:269–271CrossRef
17.
Zurück zum Zitat Sakai K, Kato J, Nakazawa T, Hirai Y (2007) The amountsofhydrogxyl radical generatedbytitaniumdioxideand 3,5% hydrogen peroxide under 405-nm diode laser irradiation. Laser Phys 17:1062–1066CrossRef Sakai K, Kato J, Nakazawa T, Hirai Y (2007) The amountsofhydrogxyl radical generatedbytitaniumdioxideand 3,5% hydrogen peroxide under 405-nm diode laser irradiation. Laser Phys 17:1062–1066CrossRef
18.
Zurück zum Zitat Suemori T, Kato J, Nakazawa T, Akashi G, Igarashi A, Hirai Y et al (2008) Effects of light irradiation on bleaching by a 3.5% hydrogen peroxide solution containing titanium dioxide. Laser Phys Lett 5(5):379CrossRef Suemori T, Kato J, Nakazawa T, Akashi G, Igarashi A, Hirai Y et al (2008) Effects of light irradiation on bleaching by a 3.5% hydrogen peroxide solution containing titanium dioxide. Laser Phys Lett 5(5):379CrossRef
19.
Zurück zum Zitat Tavares M, Goodson JM (2003) Light augments tooth whitening with peroxide. J Am Dent Assoc 134(2):167–176CrossRef Tavares M, Goodson JM (2003) Light augments tooth whitening with peroxide. J Am Dent Assoc 134(2):167–176CrossRef
20.
Zurück zum Zitat Luk K, Tam L, Hubert M (2004) Effect of light energy on peroxide tooth bleaching. J Am Dent Assoc 135(2):194–201CrossRef Luk K, Tam L, Hubert M (2004) Effect of light energy on peroxide tooth bleaching. J Am Dent Assoc 135(2):194–201CrossRef
21.
Zurück zum Zitat Panhoca VH, de Oliveira BP, Bagnato VS (2015) Dental bleaching efficacy with light application: in vitro study. Photodiagnosis Photodyn Ther 12:325–375CrossRef Panhoca VH, de Oliveira BP, Bagnato VS (2015) Dental bleaching efficacy with light application: in vitro study. Photodiagnosis Photodyn Ther 12:325–375CrossRef
22.
Zurück zum Zitat Dos SAECG, Bussadori SK, Pinto MM, Pantano Junior DA, Brugnera A, Zanin FAA et al (2018) Evaluation of in-office tooth whitening treatment with violet LED: Protocol for a randomised controlled clinical trial. BMJ Open 8(9):1–9 Dos SAECG, Bussadori SK, Pinto MM, Pantano Junior DA, Brugnera A, Zanin FAA et al (2018) Evaluation of in-office tooth whitening treatment with violet LED: Protocol for a randomised controlled clinical trial. BMJ Open 8(9):1–9
23.
Zurück zum Zitat Publication of the superior health council No. 8782 (2013) Tooth bleaching – tooth whitening. Available from: ww.shc-belgium.be. Accessed 2020 may 14 Publication of the superior health council No. 8782 (2013) Tooth bleaching – tooth whitening. Available from: ww.shc-belgium.be. Accessed 2020 may 14
24.
Zurück zum Zitat Araújo RM, Torres CRG, Araújo MAM (2010) In vitro evaluation of dental bleaching effectiveness using hybrid lights activation. Rev Odonto Science 25(2): 159–64.92013 Araújo RM, Torres CRG, Araújo MAM (2010) In vitro evaluation of dental bleaching effectiveness using hybrid lights activation. Rev Odonto Science 25(2): 159–64.92013
25.
Zurück zum Zitat Bortolatto JF, Pretel H, Neto CS, Andrade MF, Moncada G, Oliveira OB (2013) Effects of LED-laser hybrid light on bleaching effectiveness and tooth sensitivity: a randomized clinical study. Laser Phys Lett 10(8):1–6CrossRef Bortolatto JF, Pretel H, Neto CS, Andrade MF, Moncada G, Oliveira OB (2013) Effects of LED-laser hybrid light on bleaching effectiveness and tooth sensitivity: a randomized clinical study. Laser Phys Lett 10(8):1–6CrossRef
26.
Zurück zum Zitat Mena-Serrano AP, Garcia E, Luque-Martinez I, Grande RHM, Loguercio AD, Reis A (2016) A single-blind randomized trial about the effect of hydrogen peroxide concentration on light-activated bleaching. Oper Dent 41(5):455–464CrossRef Mena-Serrano AP, Garcia E, Luque-Martinez I, Grande RHM, Loguercio AD, Reis A (2016) A single-blind randomized trial about the effect of hydrogen peroxide concentration on light-activated bleaching. Oper Dent 41(5):455–464CrossRef
27.
Zurück zum Zitat Rastelli AN, Dias HB, Carrera ET, Barros AC, Santos DD, Panhóca CH et al (2018) Violet LED with low concentration carbamide peroxide for dental bleaching: a case report. Photodiagnosis Photodyn Ther 23(1):270–272CrossRef Rastelli AN, Dias HB, Carrera ET, Barros AC, Santos DD, Panhóca CH et al (2018) Violet LED with low concentration carbamide peroxide for dental bleaching: a case report. Photodiagnosis Photodyn Ther 23(1):270–272CrossRef
28.
Zurück zum Zitat Gallinari MO, Cintra LT, Souza MB, Barboza AC, Esteves LM, Fagundes TC et al (2019) Clinical analysis of color change and tooth sensitivity to violet LED during bleaching treatment: a case series with split-mouth design. Photodiagnosis Photodyn Ther 27:59–65CrossRef Gallinari MO, Cintra LT, Souza MB, Barboza AC, Esteves LM, Fagundes TC et al (2019) Clinical analysis of color change and tooth sensitivity to violet LED during bleaching treatment: a case series with split-mouth design. Photodiagnosis Photodyn Ther 27:59–65CrossRef
29.
Zurück zum Zitat Kury M, Wada EE, da Silva DP, Tabchoury CPM, Giannini M, Cavalli V (2020) Effect of violet LED light on in-office bleaching protocols: a randomized controlled clinical trial. J. Appl. Oral Sci 28:e20190720CrossRef Kury M, Wada EE, da Silva DP, Tabchoury CPM, Giannini M, Cavalli V (2020) Effect of violet LED light on in-office bleaching protocols: a randomized controlled clinical trial. J. Appl. Oral Sci 28:e20190720CrossRef
30.
Zurück zum Zitat Estay J, Angel P, Bersezio C, Peña M, Fernandéz E (2019) The change of color by whiteness indexes and its psychosocial and self-perception effects when using low vs. high comcentration whitening gels: a one-year follow-up. BMC Oral Health 20:1–24 Estay J, Angel P, Bersezio C, Peña M, Fernandéz E (2019) The change of color by whiteness indexes and its psychosocial and self-perception effects when using low vs. high comcentration whitening gels: a one-year follow-up. BMC Oral Health 20:1–24
31.
Zurück zum Zitat Vildosola P, Botter J, Avalos F, Godoy I, Matins J, Fernández E (2017) Teeth bleaching with low concentrations of hydrogen peroxide (6%) and catalyzed by LED blue (450 ±10 nm) and laser infrared (808 ±10 nm) light for in-office treatment: randomized clinical trial 1-year follow-up. J Esthet Restor Dent 29:339–345CrossRef Vildosola P, Botter J, Avalos F, Godoy I, Matins J, Fernández E (2017) Teeth bleaching with low concentrations of hydrogen peroxide (6%) and catalyzed by LED blue (450 ±10 nm) and laser infrared (808 ±10 nm) light for in-office treatment: randomized clinical trial 1-year follow-up. J Esthet Restor Dent 29:339–345CrossRef
32.
Zurück zum Zitat Almeida LCAG, Soares DG, Gallinari MO, de Souza Costa CA, dos Santos PH, Briso ALF (2015) Color alteration, hydrogen peroxide diffusion, and cytotoxicity caused by in-office bleaching protocols. Clin Oral Investig 19(3):673–680CrossRef Almeida LCAG, Soares DG, Gallinari MO, de Souza Costa CA, dos Santos PH, Briso ALF (2015) Color alteration, hydrogen peroxide diffusion, and cytotoxicity caused by in-office bleaching protocols. Clin Oral Investig 19(3):673–680CrossRef
33.
Zurück zum Zitat Vildosola P, Vera F, Ramirez J, Rencoret J, Pretel H, Oliveira OB et al (2017) Comparison of effectiveness and sensitivity using two in-office bleaching protocols for a 6% hydrogen peroxide gel in a randomized clinical trial. Oper Dent 42(3):244–252CrossRef Vildosola P, Vera F, Ramirez J, Rencoret J, Pretel H, Oliveira OB et al (2017) Comparison of effectiveness and sensitivity using two in-office bleaching protocols for a 6% hydrogen peroxide gel in a randomized clinical trial. Oper Dent 42(3):244–252CrossRef
34.
Zurück zum Zitat Matis BA, Cochran MA, Franco M, Al-Ammar W, Eckert GJ, Stropes M (2007) Eight in-office tooth whitening systems evaluated in vivo: a pilot study. Oper Dent 32(4):322–327CrossRef Matis BA, Cochran MA, Franco M, Al-Ammar W, Eckert GJ, Stropes M (2007) Eight in-office tooth whitening systems evaluated in vivo: a pilot study. Oper Dent 32(4):322–327CrossRef
35.
Zurück zum Zitat Tano E, Otsuki M, Kato J, Sadr A, Ikeda M, Tagami J (2012) Effects of 405nm diode laser on titanium oxide bleaching activation. Photomed Laser Surg 30(11):648–654CrossRef Tano E, Otsuki M, Kato J, Sadr A, Ikeda M, Tagami J (2012) Effects of 405nm diode laser on titanium oxide bleaching activation. Photomed Laser Surg 30(11):648–654CrossRef
36.
Zurück zum Zitat Khashayar G, Bain PA, Salari S, Dozic A, Kleverlaan CJ, Feilzer AJ (2014) Perceptibility and acceptability thresholds for colour differences in dentistry. J Dent 42(6):637–644CrossRef Khashayar G, Bain PA, Salari S, Dozic A, Kleverlaan CJ, Feilzer AJ (2014) Perceptibility and acceptability thresholds for colour differences in dentistry. J Dent 42(6):637–644CrossRef
37.
Zurück zum Zitat Markowitz K (2010) Pretty painful: why does tooth bleaching hurt? Med Hypotheses 74:835–840CrossRef Markowitz K (2010) Pretty painful: why does tooth bleaching hurt? Med Hypotheses 74:835–840CrossRef
38.
Zurück zum Zitat Zanin F (2016) Recent advances in dental bleaching with laser and LEDs. Photomed Laser Surg 34(4):135–136CrossRef Zanin F (2016) Recent advances in dental bleaching with laser and LEDs. Photomed Laser Surg 34(4):135–136CrossRef
39.
Zurück zum Zitat Bersezio C, Estay J, Jorquera G, Peña M, Araya C, Angel P et al (2019) Effectiveness of dental bleaching with 37.5% and 6% hydrogen peroxide and its effect on quality of life. Oper Dent 44(2):146–55CrossRef Bersezio C, Estay J, Jorquera G, Peña M, Araya C, Angel P et al (2019) Effectiveness of dental bleaching with 37.5% and 6% hydrogen peroxide and its effect on quality of life. Oper Dent 44(2):146–55CrossRef
Metadaten
Titel
Clinical performance of 6% hydrogen peroxide containing TiO2N nanoparticles activated by LED in varying wavelengths—a randomized clinical trial
verfasst von
Tamara Carolina Trevisan
Janaina Freitas Bortolatto
Giovana Rizzi
Bruna Tavoni Meloto
Andrea Abi Rached Dantas
Osmir Batista de Oliveira Junior
Publikationsdatum
15.11.2021
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 3/2022
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-021-03464-1

Weitere Artikel der Ausgabe 3/2022

Lasers in Medical Science 3/2022 Zur Ausgabe