Skip to main content
Erschienen in: Journal of Medical Case Reports 1/2019

Open Access 01.12.2019 | Case report

Retrograde transcatheter aortic valve closure in an infant with failing Norwood stage I palliation: a case report

verfasst von: Hannah E. Fürniss, Rouven Kubicki, Brigitte Stiller, Katja Reineker, Matthias Siepe, Jochen Grohmann

Erschienen in: Journal of Medical Case Reports | Ausgabe 1/2019

Abstract

Background

Aortic valve regurgitation leading to coronary steal phenomenon can severely impair cardiac function in hypoplastic left heart syndrome, thus worsening long-term outcome.

Case presentation

A German infant with borderline aortic and mitral valve, hypoplastic left ventricle, ventricular septal defect, and hypoplastic aortic arch with critical coarctation initially underwent aortic arch reconstruction and aortic valve dilation with the aim of biventricular correction later on. Unfortunately, severe cardiac dysfunction necessitated a change in strategy entailing modified stage I Norwood palliation. Increasing aortic regurgitation with coronary steal was revealed postoperatively, which required redo surgery to oversew the valve. However, pronounced aortic regurgitation recurred, causing severe cardiac decompensation with repeated resuscitation. As a bailout strategy, we performed aortic valve closure via transfemoral retrograde implantation of an Amplatzer Duct Occluder II device. This led to the patient’s rapid stabilization while circumventing highly risky renewed surgery in such a critically ill infant.

Conclusions

Retrograde transcatheter aortic valve closure may be considered a feasible alternative in infants with a failing single ventricle due to aortic regurgitation, with critical device evaluation being crucial for successful device implantation in this young age group.
Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1186/​s13256-019-2141-5) contains supplementary material, which is available to authorized users.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
ADO II
Amplatzer Duct Occluder II
AoV
Aortic valve
AR
Aortic regurgitation
CoA
Coarctation of the aorta
HLHS
Hypoplastic left heart syndrome
LV
Left ventricle
LVOT
Left ventricular outflow tract
PDA
Patent ductus arteriosus
VSD
Ventricular septal defect

Introduction

Hypoplastic left heart syndrome (HLHS) is characterized by variably underdeveloped left-sided heart structures, mostly leading to single-ventricle physiology. Treatment options are limited to heart transplantation or a three-stage palliation concept. Though rare in HLHS, aortic regurgitation (AR) can lead to a coronary steal phenomenon, worsening morbidity and mortality significantly [1]. Although AR in HLHS has primarily been treated surgically in the past, interventional concepts have emerged in the last decade [2, 3]. In this case report, we present a novel, retrograde approach for transcatheter aortic valve (AoV) closure as a bailout strategy for AR in HLHS.

Case presentation

A full-term male German neonate (birth weight 3110 g) was diagnosed postnatally with borderline mitral and aortic valve (z-score −2 for both) and hypoplastic left ventricle (LV), as well as hypoplastic aortic arch with critical coarctation (CoA), perimembranous ventricular septal defect (VSD; size 3–4 mm), and patent ductus arteriosus (PDA). His LV function was significantly impaired, so we did not take a primary corrective surgical approach initially. To preserve the option for later biventricular correction, we performed CoA resection and PDA closure on the 11th day of life with the aim of improving systemic blood perfusion and allowing for growth and functional improvement of the left-sided heart structures over time. Due to increasingly severe stenosis of the AoV, the patient underwent retrograde balloon valvuloplasty of the AoV at 3 weeks of age. However, although ballooning had moderately reduced the gradient, severe biventricular dysfunction developed as a result of the persistent pressure overload. In an emergency setting, a modified stage I Norwood palliation (aortic arch augmentation, Blalock-Taussig shunt, atrioseptectomy, VSD enlargement, resection of a subaortic membrane) was performed to acutely relieve the ventricles when the patient was aged 5 weeks. Later, increasingly severe AR of the native AoV became apparent, leading to recurring cardiac decompensation. This necessitated redo surgery with the AoV being oversewn 8 days after the stage I procedure.
Nine weeks later, we observed recurrent, significant AR (Fig. 1; Additional file 1: Video S1), with the patient demonstrating signs of impaired coronary perfusion in stressful situations, including repeated events of cardiopulmonary decompensation requiring resuscitation. Due to this unstable hemodynamic situation, we opted against further surgery in favor of transcatheter AoV closure. The patient’s body weight at this time was 4100 g. To accommodate the native AoV’s “ring” diameter of 8.3 × 7.0 mm (Fig. 1), we selected an Amplatzer Duct Occluder II 3–4 (ADO II; Abbott, St. Paul, MN, USA) with 9-mm discs. A 4-French Cook Flexor 45-cm-long guiding sheath (Cook Medical, Bloomington, IN, USA) was used to deliver the device to the left ventricular outflow tract (LVOT) via the right femoral artery. Positioning of the ADO II into the aortic root and LVOT was guided by transesophageal echocardiography and fluoroscopy. Repeated aortic root angiograms prior to device release safely ruled out coronary artery obstruction by the aortic disc (Fig. 2; Additional file 2: Video S2). An electrocardiogram demonstrated continued absence of atrioventricular conduction block. After the device’s release, we confirmed stable device position in the aortic root and LVOT with minimal residual AoV regurgitation (Fig. 3; Additional file 3: Video S3), preserved biventricular function, and unobstructed flow over the VSD (Additional file 4: Video S4). During the intervention, the patient was heparinized, followed by dual-antiplatelet therapy. He was extubated 5 days after the intervention without presenting any signs of respiratory distress or coronary ischemia.
At the age of 4 months, a successful Glenn operation was achieved. However, over the long term, the infant’s respiratory situation remained problematic, and he could not be permanently weaned from mechanical ventilation. Ultimately, the patient died at the age of 6 months due to pneumonia with subsequent sepsis and cardiac decompensation (Additional file 5). Signs of endocarditis or impaired coronary perfusion were not apparent clinically or echocardiographically at any time point after device implantation.

Discussion

We describe successful percutaneous retrograde AoV closure via the femoral artery with an ADO II device in a 3-month-old infant with borderline LV and failing Norwood stage I palliation. Severe native or acquired AR leading to impaired coronary perfusion is a rare but potentially life-threatening complication in HLHS. Additional anatomical features promoting LV decompression during diastole, such as a VSD, can aggravate the steal effect [4].
Interventional AR therapy is emerging as an alternative to operative AoV closure [2, 3, 5]. Previously, successful retrograde LVOT closure with an Amplatzer Vascular Plug 4 to treat AR in a child with stage II palliation [2] was described. Moreover, another case demonstrated the feasibility and effectiveness of AoV device closure via an antegrade transvenous approach with an Amplatzer Septal Occluder using a 6-French long sheath in an infant with failing stage I palliation [3]. We opted for a retrograde transarterial approach with a duct occluder that has not yet been described in the MEDLINE database for interventional AoV closure in patients with HLHS. Retrograde access was enabled by the ADO II’s symmetrical design and its slim delivery system, facilitating device advancement through the infant’s delicate arterial vasculature. Unlike in the antegrade approach, retrograde access does not require crossing of the septum and the mitral valve or the formation of a straining loop in the LV to reach and cross the AoV with the long delivery sheath. The retrograde approach enables direct access to the AoV, thus greatly facilitating device implantation and making the technique more feasible in complex anatomies and preexisting impaired ventricular function.

Conclusions

Retrograde transcatheter AoV closure is a viable bailout option in the context of failing single-ventricle palliation with significant AoV regurgitation. Risks of coronary artery obstruction, VSD obstruction, and conduction block, as well as vessel damage at the access site, can be limited by careful and individualized device choice, making AoV device closure an alternative to high-risk redo surgery in certain patients.

Acknowledgements

We thank Carole Cürten for language editing and Stefan Heinz for graphic design.
No ethics approval was required. Informed consent was provided by the patient’s parents for all operations and interventions mentioned in the report.
Written informed consent was obtained from the patient’s legal guardians for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Competing interests

The authors declare that they have no competing interests.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Rouillard KP, Moore P, Silverman NH. Congenital absence of aortic valvar leaflets: a rare variant of the hypoplastic left heart syndrome. Cardiol Young. 2001;11:453–7.CrossRef Rouillard KP, Moore P, Silverman NH. Congenital absence of aortic valvar leaflets: a rare variant of the hypoplastic left heart syndrome. Cardiol Young. 2001;11:453–7.CrossRef
2.
Zurück zum Zitat Elling R, Stiller B, Grohmann J. Transcatheter device occlusion of the left ventricular outflow tract as treatment for severe aortic regurgitation in hypoplastic left heart syndrome. Catheter Cardiovasc Interv. 2015;86:463–6.CrossRef Elling R, Stiller B, Grohmann J. Transcatheter device occlusion of the left ventricular outflow tract as treatment for severe aortic regurgitation in hypoplastic left heart syndrome. Catheter Cardiovasc Interv. 2015;86:463–6.CrossRef
3.
5.
Zurück zum Zitat Parikh KS, Mehrotra AK, Russo MJ, Lang RM, Anderson A, Jeevanandam V, Freed BH, Paul JD, Karol J, Nathan S, Shah AP. Percutaneous transcatheter aortic calve closure successfully treats left ventricular assist device–associated aortic insufficiency and improves cardiac hemodynamics. JACC Cardiovasc Interv. 2013;6:84–9. https://doi.org/10.1016/j.jcin.2012.08.021.CrossRefPubMed Parikh KS, Mehrotra AK, Russo MJ, Lang RM, Anderson A, Jeevanandam V, Freed BH, Paul JD, Karol J, Nathan S, Shah AP. Percutaneous transcatheter aortic calve closure successfully treats left ventricular assist device–associated aortic insufficiency and improves cardiac hemodynamics. JACC Cardiovasc Interv. 2013;6:84–9. https://​doi.​org/​10.​1016/​j.​jcin.​2012.​08.​021.CrossRefPubMed
Metadaten
Titel
Retrograde transcatheter aortic valve closure in an infant with failing Norwood stage I palliation: a case report
verfasst von
Hannah E. Fürniss
Rouven Kubicki
Brigitte Stiller
Katja Reineker
Matthias Siepe
Jochen Grohmann
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
Journal of Medical Case Reports / Ausgabe 1/2019
Elektronische ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-019-2141-5

Weitere Artikel der Ausgabe 1/2019

Journal of Medical Case Reports 1/2019 Zur Ausgabe