Sawtooth fetal heart rate pattern associated with a favorable neurological outcome in an infant: a case report

verfasst von: Satoshi Ohira, Sakura Yamanaka, Ryoichi Asaka, Hirofumi Ando, Chiho Fuseya, Norihiko Kikuchi, Tsutomu Miyamoto, Makoto Kanai, Tanri Shiozawa

Erschienen in: Journal of Medical Case Reports | Ausgabe 1/2019

Abstract

Background

The sawtooth fetal heart rate pattern is rare, and has been reported as a possible indicator of neurological sequelae in newborns. However, we observed this fetal heart rate pattern in an infant with normal neurological function.

Case presentation

A 29-year-old primigravida Japanese woman presented to our hospital at 40 weeks and 1 day of gestation with marked vaginal bleeding. Since admission, fetal heart rate tracing consistently demonstrated a sawtooth-like pattern. There were 3–4 oscillations per minute, and their amplitude was 30–40 beats per minute. An emergency cesarean section was performed because of non-reassuring fetal status. Evidence of placental abruption was not observed. The newborn was a male weighing 2936 g, with an Apgar score of 1 and 3 at 1 minute and 5 minutes, respectively. The infant received brain cooling, but was discharged uneventfully. A follow-up examination at age 3 years demonstrated no developmental restriction.

Conclusion

Although the Apgar score of the newborn was low, the infant had no neurological sequelae. Thus, the sawtooth fetal heart rate pattern may not be linked to in utero irreversible fetal central nervous system injury.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Background

Antenatal and intrapartum application of electronic fetal heart rate (FHR) monitoring for the evaluation of fetal condition are of common use in developed countries. The efficacy of electronic FHR monitoring during labor is judged by its ability to decrease complications, such as neonatal seizures, cerebral palsy, or intrapartum fetal death, while minimizing the need for unnecessary obstetric interventions [1, 2]. Despite well-designed basic science investigations into the physiology underlying standard FHR patterns (variability, accelerations, and decelerations), these observations have not translated into measurable positive impacts on newborn outcomes but have contributed significantly to the cesarean delivery rate [37]. Recently, Andrikopoulou and Vintzileos [8] reported three cases of documented central nervous system (CNS) injury with a characteristic FHR sawtooth-like pattern. However, we observed this FHR pattern in an infant with normal neurological function. Here we report a case of sawtooth FHR pattern associated with a favorable neurological outcome in an infant.

Case presentation

A 29-year-old primigravida Japanese woman presented to our hospital at 40 weeks and 1 day of gestation with marked vaginal bleeding. The posterior placenta had been low-lying, but had migrated to the upper uterine segment in the third trimester. Since admission, FHR tracing consistently demonstrated a sawtooth-like pattern with indeterminate baseline (Fig. 1). There were 3–4 sharp oscillations per minute, and their amplitude was 30–40 beats per minute (bpm) (Fig. 2). Although fetal movement was slightly observed, only a small amount of amniotic fluid was noted by ultrasonography. The middle cerebral artery peak systolic velocity of the fetus was 100 cm/second (1.55 multiples of the median); therefore, we initially suspected fetal anemia.
Emergency cesarean section was performed because of non-reassuring fetal status. Evidence of placental abruption was not observed. The newborn was a male weighing 2936 g, with an Apgar score of 1 and 3 at 1 minute and 5 minutes, respectively. The umbilical artery cord pH was not available because the artery collapsed. The newborn was not severely anemic, with a hemoglobin level of 13.3 g/dl. The venous blood pH was 6.860 and base excess was − 21.9. Sarnat staging for hypoxic-ischemic encephalopathy [9] of this newborn was grade II moderate. Therefore, the infant received brain cooling for 72 hours from 4 hours after birth. No abnormal findings were detected by brain magnetic resonance imaging performed at 13 days after birth, and the infant was discharged uneventfully. A follow-up examination including DENVER II Developmental Screening Test [10] at age 1, 2, and 3 years demonstrated no developmental restriction.

Discussion

The sawtooth FHR pattern is rare, and is sometimes confused with sinusoidal pattern [8]. This FHR pattern is characterized by the following: (1) three to five sawtooth-like sharp oscillations per minute; (2) amplitude > 20 bpm; and (3) unstable or indeterminate baseline [8]. On the other hand, true sinusoidal FHR pattern is characterized by the following: (1) stable baseline FHR of 120–160 bpm; (2) amplitude of 5–15 bpm; (3) frequency of 2–5 cycles per minute; (4) fixed or flat short-term variability; (5) oscillations of the sinusoidal wave form above and below a baseline; and (6) no area of normal FHR variability or reactivity [11, 12]. The FHR pattern in our case demonstrated 3–4 oscillations per minute, amplitude of 30–40 bpm, and indeterminate baseline; therefore, the FHR pattern in our case is consistent with the above-described features of the sawtooth FHR pattern.
Other than true sinusoidal FHR pattern, another conventional undulating FHR pattern may be due to pseudo-sinusoidal FHR pattern [11, 13]. Pseudo-sinusoidal FHR patterns include all patterns in which undulatory waveforms, or regular FHR baseline oscillations of constant amplitude, alternate with episodes of normal baseline variability or activity [13]. Murphy et al. observed 230 pseudo-sinusoidal FHR patterns in labor, and classified 219 into minor (amplitude 5–15 bpm) and 11 into intermediate (amplitude 16–24 bpm) [13]. Major pseudo-sinusoidal patterns (amplitude > 24 bpm) were not observed [13]. Before the sawtooth FHR pattern was proposed, our case might be considered to be a major pseudo-sinusoidal pattern because of large amplitude.
Andrikopoulou and Vintzileos reported three cases of sawtooth FHR pattern due to in utero fetal CNS injury [8]. In their first case, there was a sudden onset of sawtooth FHR pattern during labor. The Apgar score after a vaginal delivery was 9 and 9 at 1 minute and 5 minutes, respectively. Magnetic resonance imaging of the newborn, which was performed because of facial twitches, showed infarction of the left cerebral hemisphere because of a middle cerebral artery thrombosis. The approximate timing of the fetal stroke coincided with the abrupt onset of the sawtooth FHR pattern in labor. In their second case, the patient was admitted with sawtooth FHR pattern. Emergency cesarean section was performed and the Apgar score was 0 and 3 at 1 minute and 5 minutes, respectively. An electroencephalogram was abnormal, and the infant received brain cooling but unfortunately died. The third case had sawtooth FHR pattern during the second stage of labor, and the Apgar score was 3 and 6 at 1 minute and 5 minutes, respectively. A cranial ultrasound of the neonate revealed grade II intraventricular hemorrhage.
In our case, the Apgar score of the newborn was low, but the infant had no neurological sequelae. Although the reason why the sawtooth FHR pattern appeared is unclear, we speculate that transient fetal asphyxia was caused by circulatory failure of the placenta due to marked hemorrhage from placental margin.

Conclusions

This is the first report of sawtooth FHR pattern without fetal CNS injury. Thus, this FHR pattern may not be linked to in utero irreversible fetal CNS injury. Further studies are needed to clarify the pathology underlying sawtooth FHR pattern.

Acknowledgements

The authors are grateful to Keiya Fujimori (Department of Obstetrics and Gynecology, School of Medicine, Fukushima Medical University) for the advisement in this case.
The study was sent to the ethical committee of Shinshu University School of Medicine and need for approval was waived.
Written informed consent was obtained from the patient’s legal guardian for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat American College of Obstetricians and Gynecologists. ACOG Practice Bulletin No.62: Intrapartum fetal heart rate monitoring. Obstet Gynecol. 2005;105:1161–9.CrossRef American College of Obstetricians and Gynecologists. ACOG Practice Bulletin No.62: Intrapartum fetal heart rate monitoring. Obstet Gynecol. 2005;105:1161–9.CrossRef
2.
Zurück zum Zitat Freeman RK. Problems with intrapartum fetal heart rate monitoring interpretation and patient management. Obstet Gynecol. 2002;100:813–26.PubMed Freeman RK. Problems with intrapartum fetal heart rate monitoring interpretation and patient management. Obstet Gynecol. 2002;100:813–26.PubMed
3.
Zurück zum Zitat Clark SL, Meyers JA, Frye DK, Garthwaite T, Lee AJ, Perlin JB. Recognition and response to electronic fetal heart rate patterns: impact on newborn outcomes and primary cesarean delivery rate in women undergoing induction of labor. Am J Obstet Gynecol. 2015;212:494.e1–6.CrossRef Clark SL, Meyers JA, Frye DK, Garthwaite T, Lee AJ, Perlin JB. Recognition and response to electronic fetal heart rate patterns: impact on newborn outcomes and primary cesarean delivery rate in women undergoing induction of labor. Am J Obstet Gynecol. 2015;212:494.e1–6.CrossRef
4.
Zurück zum Zitat Williams RL, Hawes WE. Cesarean section, fetal monitoring, and perinatal mortality in California. Am J Public Health. 1979;69:864–70.CrossRef Williams RL, Hawes WE. Cesarean section, fetal monitoring, and perinatal mortality in California. Am J Public Health. 1979;69:864–70.CrossRef
5.
Zurück zum Zitat Haverkamp AD, Thompson HE, McFee JG, Cetrulo C. The evaluation of continuous fetal heart rate monitoring in high risk pregnancy. Am J Obstet Gynecol. 1976;125:310–20.CrossRef Haverkamp AD, Thompson HE, McFee JG, Cetrulo C. The evaluation of continuous fetal heart rate monitoring in high risk pregnancy. Am J Obstet Gynecol. 1976;125:310–20.CrossRef
6.
Zurück zum Zitat Haverkamp AD, Orleans M, Langendoerfer S, McFee J, Murphy J, Thompson HE. A controlled trial of the differential effects of intrapartum fetal monitoring. Am J Obstet Gynecol. 1979;134:399–412.CrossRef Haverkamp AD, Orleans M, Langendoerfer S, McFee J, Murphy J, Thompson HE. A controlled trial of the differential effects of intrapartum fetal monitoring. Am J Obstet Gynecol. 1979;134:399–412.CrossRef
7.
Zurück zum Zitat Renou P, Warwick N, Wood C. Autonomic control of fetal heart rate. Am J Obstet Gynecol. 1969;105:949–53.CrossRef Renou P, Warwick N, Wood C. Autonomic control of fetal heart rate. Am J Obstet Gynecol. 1969;105:949–53.CrossRef
8.
Zurück zum Zitat Andrikopoulou M, Vintzileos AM. Sawtooth fetal heart rate pattern due to in utero fetal central nervous system injury. Am J Obstet Gynecol. 2016;214:403.e1–4.CrossRef Andrikopoulou M, Vintzileos AM. Sawtooth fetal heart rate pattern due to in utero fetal central nervous system injury. Am J Obstet Gynecol. 2016;214:403.e1–4.CrossRef
9.
Zurück zum Zitat Sarnat H, Sarnat M. Neonatal encephalopathy following fetal distress. Arch Neurol. 1976;33:695–705. Sarnat H, Sarnat M. Neonatal encephalopathy following fetal distress. Arch Neurol. 1976;33:695–705.
10.
Zurück zum Zitat Frankenburg WK, Dodds J, Archer P, Shapiro H, Bresnick B. The Denver II: a major revision and restandardization of the Denver Developmental Screening Test. Pediatrics. 1992;89:91–7.PubMed Frankenburg WK, Dodds J, Archer P, Shapiro H, Bresnick B. The Denver II: a major revision and restandardization of the Denver Developmental Screening Test. Pediatrics. 1992;89:91–7.PubMed
11.
Zurück zum Zitat Modanlou HD, Murata Y. Sinusoidal heart rate pattern: reappraisal of its definition and clinical significance. J Obstet Gynaecol Res. 2004;30:169–80.CrossRef Modanlou HD, Murata Y. Sinusoidal heart rate pattern: reappraisal of its definition and clinical significance. J Obstet Gynaecol Res. 2004;30:169–80.CrossRef
12.
Zurück zum Zitat Modanlou HD, Freedman RK. Sinusoidal heart rate pattern: its definition and clinical significance. Am J Obstet Gynecol. 1982;142:1033–8.CrossRef Modanlou HD, Freedman RK. Sinusoidal heart rate pattern: its definition and clinical significance. Am J Obstet Gynecol. 1982;142:1033–8.CrossRef
13.
Zurück zum Zitat Murphy KW, Russell V, Collins A, Johnson P. The prevalence, aetiology and clinical significance of pseudo-sinusoidal fetal heart rate patterns in labour. Br J Obstet Gynaecol. 1991;98:1093–101.CrossRef Murphy KW, Russell V, Collins A, Johnson P. The prevalence, aetiology and clinical significance of pseudo-sinusoidal fetal heart rate patterns in labour. Br J Obstet Gynaecol. 1991;98:1093–101.CrossRef
Metadaten
Titel
Sawtooth fetal heart rate pattern associated with a favorable neurological outcome in an infant: a case report
verfasst von
Satoshi Ohira
Sakura Yamanaka
Ryoichi Asaka
Hirofumi Ando
Chiho Fuseya
Norihiko Kikuchi
Tsutomu Miyamoto
Makoto Kanai
Tanri Shiozawa
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
Journal of Medical Case Reports / Ausgabe 1/2019
Elektronische ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-019-2170-0

Weitere Artikel der Ausgabe 1/2019

Journal of Medical Case Reports 1/2019 Zur Ausgabe