Skip to main content
Erschienen in: Journal of Medical Case Reports 1/2014

Open Access 01.12.2014 | Case report

Successful diagnosis of tuberculous lymphadenitis by loop-mediated isothermal amplification of cutaneous samples from an ulcerated surface lesion: a case report

verfasst von: Shuichi Kawano, Takuya Maeda, Junichi Watanabe, Yuji Fujikura, Kei Mikita, Yu Hara, Soichiro Kanoh, Fumihiko Kimura, Yasushi Miyahira, Akihiko Kawana

Erschienen in: Journal of Medical Case Reports | Ausgabe 1/2014

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Introduction

Tuberculous lymphadenitis is the most frequent form of extrapulmonary tuberculous. Although nucleic acid amplification assays such as polymerase chain reaction have recently become mainstream techniques for diagnosing tuberculous lymphadenitis, they are still not routinely performed in developing countries because of their high costs and complicated procedures.

Case presentation

We describe a case of tuberculous lymphadenitis in a 79-year-old Japanese man who had been on continuous hemodialysis for end-stage renal disease. We employed loop-mediated isothermal amplification and the procedure for ultrarapid extraction to develop a fast and easy-to-perform procedure for diagnosing tuberculous lymphadenitis.

Conclusions

The commercially available loop-mediated isothermal amplification assay kit and a rapid purification procedure enabled us to identify and amplify a Mycobacterium tuberculosis–specific gene within just 1.5 hours.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1752-1947-8-254) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

Skaw conceived the study, participated in its design and coordination and helped draft the manuscript. TM was directly involved in the overall care of the patient and drafted the manuscript. JW, YF, KM, YH, SKan, FK, YM and AK were involved in data investigation and the patient’s treatment. All authors read and approved the final manuscript.
Abkürzungen
FNA
Fine-needle aspiration
LAMP
Loop-mediated isothermal amplification
PCR
Polymerase chain reaction
PURE
Procedure for ultrarapid extraction
TB
Tuberculous.

Introduction

Tuberculous (TB) lymphadenitis is the most frequent form of extrapulmonary tuberculosis and cervical lymphadenopathy is its most common clinical manifestation [1]. Because lymphadenopathy can be attributed to multiple etiologies, such as malignancy, autoimmune disease and infection, it is often difficult to differentiate TB lymphadenitis from other forms of lymphadenitis on clinical grounds alone. The advent of novel diagnostic techniques, in particular loop-mediated isothermal amplification (LAMP), provides accessible, cost-effective, easy-to-perform methods for diagnosing pulmonary TB by examination of respiratory specimens [2]. Boehme et al. demonstrated that LAMP has a diagnostic success rate of 97.7% for smear-positive sputum specimens and 48.8% for smear-negative but culture-positive specimens [3]. In our present case, to detect Mycobacterium tuberculosis in a patient diagnosed with TB lymphadenitis, we examined boiled swab samples taken from an ulcerative lesion by LAMP after applying the procedure for ultrarapid extraction (PURE) to isolate target deoxyribonucleic acid (DNA) molecules for use as LAMP reagents.

Case presentation

A 79-year-old Japanese man who had been on continuous hemodialysis for end-stage renal disease since 2004 visited an outpatient clinic complaining of a unilateral cervical mass and intermittent fever of more than three months’ duration. An examination at the clinic revealed three palpable right cervical lymph nodes. His body temperature was 37.4°C, with no chills or night sweats. Key laboratory data upon admission are shown in Table 1. The findings of the lab test for human immunodeficiency virus (HIV) were negative. Computed tomography of the neck and chest revealed multiple enlarged lymph nodes measuring 40mm×20mm with low central attenuation predominantly along the lateral margin of the right sternocleidomastoid muscle (Figure 1A). In addition, several enlarged lymph nodes measuring 29mm×30mm in the supraclavicular region were also noted (Figure 1B). The result of an assay for interferon γ release was positive [4].
Table 1
Laboratory findings upon admission a
Peripheral blood
Blood chemistry
WBCs
6800/μL
T-bil
0.3mg/dL
RBCs
439×104/μL
AST
14IU/L
Hb
11.4g/dL
ALT
7IU/L
Hct
37.2%
LDH
190IU/L
PLT
23.0×104/μL
ALP
321IU/L
Seg
65.3%
γ-GTP
23IU/L
Eos
2.1%
TP
6.4g/dL
Ly
19.3%
BUN
20.0mg/dL
Mo
12.9%
Cr
5.65mg/dL
  
CPK
19.0IU/L
  
Na+
140mEq/L
  
K+
3.9mEq/L
  
Cl
101mEq/L
  
Glc
88mg/dL
  
CRP
<0.05mg/dL
  
ESR
74mm/hour
  
sIL-2R
2.05U/mL
aALP, Alkaline phosphatase; ALT, Alanine aminotransferase; AST, Alanine aminotransferase; BUN, Blood urea nitrogen; Cl, Chloride; CPK, Creatine phosphokinase; Cr, Creatinine; CRP, C-reactive protein; Eos, Eosinophils; ESR, Erythrocyte sedimentation rate; Glc, Glucose; γ-GTP, γ-Glutamyl transpeptidase; Hb, Hemoglobin; Hct, Hematocrit; K+, Potassium; LDH, Lactate dehydrogenase; Ly, Lymphocytes; Mo, Monocytes; Na+, Sodium; PLT, Platelets; RBC, Red blood cells; Seg, Segmented neutrophils; sIL-2R, Soluble interleukin 2 receptor; T-bil, Total bilirubin; TP, Total protein; WBC, White blood cells.
Suspecting TB lymphadenitis, we performed fine-needle aspiration (FNA) of the para-sternocleidomastoid nodes. The obtained specimens were examined by microscopy (smears for acid-fast bacilli and fungi), microbiological culture and cytology. The smears were negative for acid-fast bacilli, and the cytology was determined to be class II, partly due to the presence of a mass of neutrophils. Among the diagnostic procedures we used, only the six-week culture for tuberculosis with the BacT/ALERT® three-dimensional microbial detection system (bioMérieux, Nürtingen, Germany) was positive, and M. tuberculosis DNA was unequivocally identified in the positive culture by means of the COBAS® TaqMan® MTB assay (Roche Diagnostics, Rotkreuz, Switzerland) [5].
In this case, we reached a definitive diagnosis of TB lymphadenitis in an efficient manner by using a commercially available LAMP kit (Eiken Chemical, Tokyo, Japan) to amplify an M. tuberculosis-specific gene and a PURE kit (Eiken Chemical) to isolate the DNA target of interest [6]. Cutaneous swab samples were obtained by wiping the surface of an ulcerated lesion (Figure 2) with a sterile cotton swab and placing it into 960μL of DNA extraction solution. The suspension was incubated on a heat block at 100°C for 10 minutes, and DNA was rapidly extracted with the PURE kit in 30μL of solution [6]. Amplification of the M. tuberculosis– specific gene was achieved by LAMP at 64°C for 40 minutes according to the manufacturer’s instructions, and a positive LAMP result was indicated by the color change observed under ultraviolet light (Figure 3). On the basis of these results, we diagnosed TB lymphadenitis.
The patient subsequently received anti-tuberculosis chemotherapy consisting of isonicotinic acid hydrazide (300mg/day), rifampicin (450mg/day) and ethambutol hydrochloride (500mg/day after dialysis). Two weeks later, he became afebrile and had no signs of exacerbation, and his painful lymphadenopathy eventually subsided.

Discussion

The current gold standard methods for diagnosing tuberculosis are microscopy and culture. However, the poor sensitivity of microscopy and the laborious, time-consuming procedures of culturing make these modalities less than ideal. Therefore, nucleic acid amplification assays such as polymerase chain reaction (PCR) have recently become mainstream techniques for diagnosing tuberculosis [7]. However, the molecular biological technologies on which such methods are based require not only experience and expertise but also expensive equipment; this is the principal reason why most of these sophisticated diagnostic tools are not suitable for use in resource-limited, disease-endemic regions. In contrast, LAMP can amplify M. tuberculosis–specific DNA rapidly under isothermal conditions [8]. A recent meta-analysis of 10 studies conducted to estimate the diagnostic accuracy of LAMP for pulmonary tuberculosis revealed a sensitivity of 80.0% (95% confidence interval (CI), 78%–83%) and a specificity of 96.0% (95% CI, 95.0%–97.0%) [9]. Furthermore, LAMP, which, in combination with PURE, has recently been established as a diagnostic technique requiring only limited equipment and manpower, provides an accessible, cost-effective, rapid, and more appropriate molecular diagnostic tool for tuberculosis in the field setting [6]. All procedures, including the time required for sample preparation, can be performed within just 1.5 hours.
FNA is an appropriate procedure to use in the initial evaluation in diagnostic methods targeting cervical nodular lesions, including TB lymphadenitis [10, 11]. Although FNA is a non-invasive, inexpensive, viable alternative to excisional biopsy of the lymph nodes, the detection rate of M. tuberculosis by examining aspirate specimens is disappointingly low compared to microbiological techniques. Some researchers have suggested that a combination of FNA and PCR might increase the sensitivity for diagnosing TB lymphadenitis [12]. However, the overall sensitivity of PCR with aspirate specimens is significantly lower than that with biopsy specimens and histopathological examinations [13]. PCR is also notorious for yielding false-negative results. It is thus important to establish a rapid, highly sensitive molecular diagnostic method for use with FNA specimens before proceeding to more invasive procedures such as additional excisional biopsy of the lymph nodes. Although excisional biopsy for microbiological, molecular biological and histopathological evaluations has the highest diagnostic yield [11, 14], it is also the most invasive means of reaching a diagnosis. LAMP, on the other hand, is a rapid diagnostic procedure that also plays an important role in deciding which specimen-collecting procedure to employ.

Conclusions

LAMP combined with PURE enabled us to detect M. tuberculosis from swabbed samples taken from an ulcerative lesion that had purulent exudate from the lymph nodes. The procedure could be performed in just 1.5 hours, making it beneficial and convenient for use in resource-limited, disease-endemic regions. We believe that the new commercial LAMP kit not only will be useful as a primary testing tool for TB but also will provide additional diagnostic value for TB lymphadenitis. Further studies are necessary to evaluate the sensitivity and specificity of this diagnostic tool.
The Ethics Committee of the National Defense Medical College Research approved the design and protocol of this study (reference no. 1205). Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in Chief of this journal.

Acknowledgements

We thank Dr Takashi Oda for helpful comments and suggestions.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
The Creative Commons Public Domain Dedication waiver (https://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

Skaw conceived the study, participated in its design and coordination and helped draft the manuscript. TM was directly involved in the overall care of the patient and drafted the manuscript. JW, YF, KM, YH, SKan, FK, YM and AK were involved in data investigation and the patient’s treatment. All authors read and approved the final manuscript.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

© Springer Medizin

Bis 11. April 2024 bestellen und im ersten Jahr 50 % sparen!

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

© Springer Medizin

Bis 11. April 2024 bestellen und im ersten Jahr 50 % sparen!

Anhänge

Authors’ original submitted files for images

Literatur
1.
Zurück zum Zitat Geldmacher H, Taube C, Kroeger C, Magnussen H, Kirsten DK: Assessment of lymph node tuberculosis in northern Germany: a clinical review. Chest. 2002, 121: 1177-1182.CrossRefPubMed Geldmacher H, Taube C, Kroeger C, Magnussen H, Kirsten DK: Assessment of lymph node tuberculosis in northern Germany: a clinical review. Chest. 2002, 121: 1177-1182.CrossRefPubMed
2.
Zurück zum Zitat George G, Mony P, Kenneth J: Comparison of the efficacies of loop-mediated isothermal amplification, fluorescence smear microscopy and culture for the diagnosis of tuberculosis. PLoS One. 2011, 6: e21007CrossRefPubMedPubMedCentral George G, Mony P, Kenneth J: Comparison of the efficacies of loop-mediated isothermal amplification, fluorescence smear microscopy and culture for the diagnosis of tuberculosis. PLoS One. 2011, 6: e21007CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Boehme CC, Nabeta P, Henostroza G, Raqib R, Rahim Z, Gerhardt M, Sanga E, Hoelscher M, Notomi T, Hase T, Perkins MD: Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries. J Clin Microbiol. 2007, 45: 1936-1940.CrossRefPubMedPubMedCentral Boehme CC, Nabeta P, Henostroza G, Raqib R, Rahim Z, Gerhardt M, Sanga E, Hoelscher M, Notomi T, Hase T, Perkins MD: Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries. J Clin Microbiol. 2007, 45: 1936-1940.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Meier T, Eulenbruch HP, Wrighton-Smith P, Enders G, Regnath T: Sensitivity of a new commercial enzyme-linked immunospot assay (T SPOT-TB) for diagnosis of tuberculosis in clinical practice. Eur J Clin Microbiol Infect Dis. 2005, 24: 529-536.CrossRefPubMed Meier T, Eulenbruch HP, Wrighton-Smith P, Enders G, Regnath T: Sensitivity of a new commercial enzyme-linked immunospot assay (T SPOT-TB) for diagnosis of tuberculosis in clinical practice. Eur J Clin Microbiol Infect Dis. 2005, 24: 529-536.CrossRefPubMed
5.
Zurück zum Zitat Bloemberg GV, Voit A, Ritter C, Deggim V, Böttger EC: Evaluation of COBAS® TaqMan® MTB for direct detection of the Mycobacterium tuberculosis complex in comparison with Cobas Amplicor MTB. J Clin Microbiol. 2013, 51: 2112-2117.CrossRefPubMedPubMedCentral Bloemberg GV, Voit A, Ritter C, Deggim V, Böttger EC: Evaluation of COBAS® TaqMan® MTB for direct detection of the Mycobacterium tuberculosis complex in comparison with Cobas Amplicor MTB. J Clin Microbiol. 2013, 51: 2112-2117.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Mitarai S, Okumura M, Toyota E, Yoshiyama T, Aono A, Sejimo A, Azuma Y, Sugahara K, Nagasawa T, Nagayama N, Yamane A, Yano R, Kokuto H, Morimoto K, Ueyama M, Kubota M, Yi R, Ogata H, Kudoh S, Mori T: Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis. Int J Tuberc Lung Dis. 2011, 15: 1211-1217.CrossRefPubMed Mitarai S, Okumura M, Toyota E, Yoshiyama T, Aono A, Sejimo A, Azuma Y, Sugahara K, Nagasawa T, Nagayama N, Yamane A, Yano R, Kokuto H, Morimoto K, Ueyama M, Kubota M, Yi R, Ogata H, Kudoh S, Mori T: Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis. Int J Tuberc Lung Dis. 2011, 15: 1211-1217.CrossRefPubMed
7.
Zurück zum Zitat Cohen RA, Muzaffar S, Schwartz D, Bashir S, Luke S, McGartland LP, Kaul K: Diagnosis of pulmonary tuberculosis using PCR assays on sputum collected within 24 hours of hospital admission. Am J Respir Crit Care Med. 1998, 157: 156-161.CrossRefPubMed Cohen RA, Muzaffar S, Schwartz D, Bashir S, Luke S, McGartland LP, Kaul K: Diagnosis of pulmonary tuberculosis using PCR assays on sputum collected within 24 hours of hospital admission. Am J Respir Crit Care Med. 1998, 157: 156-161.CrossRefPubMed
8.
Zurück zum Zitat Geojith G, Dhanasekaran S, Chandran SP, Kenneth J: Efficacy of loop mediated isothermal amplification (LAMP) assay for the laboratory identification of Mycobacterium tuberculosis isolates in a resource limited setting. J Microbiol Methods. 2011, 84: 71-73.CrossRefPubMed Geojith G, Dhanasekaran S, Chandran SP, Kenneth J: Efficacy of loop mediated isothermal amplification (LAMP) assay for the laboratory identification of Mycobacterium tuberculosis isolates in a resource limited setting. J Microbiol Methods. 2011, 84: 71-73.CrossRefPubMed
9.
Zurück zum Zitat Yuan LY, Li Y, Wang M, Ke ZQ, Xu WZ: Rapid and effective diagnosis of pulmonary tuberculosis with novel and sensitive loop-mediated isothermal amplification (LAMP) assay in clinical samples: a meta-analysis. J Infect Chemother. 2014, 20: 86-92.CrossRefPubMed Yuan LY, Li Y, Wang M, Ke ZQ, Xu WZ: Rapid and effective diagnosis of pulmonary tuberculosis with novel and sensitive loop-mediated isothermal amplification (LAMP) assay in clinical samples: a meta-analysis. J Infect Chemother. 2014, 20: 86-92.CrossRefPubMed
10.
Zurück zum Zitat Lau SK, Wei WI, Hsu C, Engzell UC: Efficacy of fine needle aspiration cytology in the diagnosis of tuberculous cervical lymphadenopathy. J Laryngol Otol. 1990, 104: 24-27.CrossRefPubMed Lau SK, Wei WI, Hsu C, Engzell UC: Efficacy of fine needle aspiration cytology in the diagnosis of tuberculous cervical lymphadenopathy. J Laryngol Otol. 1990, 104: 24-27.CrossRefPubMed
11.
Zurück zum Zitat Fontanilla JM, Barnes A, von Reyn CF: Current diagnosis and management of peripheral tuberculous lymphadenitis. Clin Infect Dis. 2011, 53: 555-562.CrossRefPubMed Fontanilla JM, Barnes A, von Reyn CF: Current diagnosis and management of peripheral tuberculous lymphadenitis. Clin Infect Dis. 2011, 53: 555-562.CrossRefPubMed
12.
Zurück zum Zitat Singh KK, Muralidhar M, Kumar A, Chattopadhyaya TK, Kapila K, Singh MK, Sharma SK, Jain NK, Tyagi JS: Comparison of in house polymerase chain reaction with conventional techniques for the detection of Mycobacterium tuberculosis DNA in granulomatous lymphadenopathy. J Clin Pathol. 2000, 53: 355-361.CrossRefPubMedPubMedCentral Singh KK, Muralidhar M, Kumar A, Chattopadhyaya TK, Kapila K, Singh MK, Sharma SK, Jain NK, Tyagi JS: Comparison of in house polymerase chain reaction with conventional techniques for the detection of Mycobacterium tuberculosis DNA in granulomatous lymphadenopathy. J Clin Pathol. 2000, 53: 355-361.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Tachibana T, Orita Y, Fujisawa M, Nakada M, Ogawara Y, Matsuyama Y, Abe I, Sato Y, Uesaka K, Nishizaki K: Factors that make it difficult to diagnose cervical tuberculous lymphadenitis. J Infect Chemother. 2013, 19: 1015-1020.CrossRefPubMed Tachibana T, Orita Y, Fujisawa M, Nakada M, Ogawara Y, Matsuyama Y, Abe I, Sato Y, Uesaka K, Nishizaki K: Factors that make it difficult to diagnose cervical tuberculous lymphadenitis. J Infect Chemother. 2013, 19: 1015-1020.CrossRefPubMed
14.
Zurück zum Zitat Lee KC, Tami TA, Lalwani AK, Schecter G: Contemporary management of cervical tuberculosis. Laryngoscope. 1992, 102: 60-64.CrossRefPubMed Lee KC, Tami TA, Lalwani AK, Schecter G: Contemporary management of cervical tuberculosis. Laryngoscope. 1992, 102: 60-64.CrossRefPubMed
Metadaten
Titel
Successful diagnosis of tuberculous lymphadenitis by loop-mediated isothermal amplification of cutaneous samples from an ulcerated surface lesion: a case report
verfasst von
Shuichi Kawano
Takuya Maeda
Junichi Watanabe
Yuji Fujikura
Kei Mikita
Yu Hara
Soichiro Kanoh
Fumihiko Kimura
Yasushi Miyahira
Akihiko Kawana
Publikationsdatum
01.12.2014
Verlag
BioMed Central
Erschienen in
Journal of Medical Case Reports / Ausgabe 1/2014
Elektronische ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-8-254

Weitere Artikel der Ausgabe 1/2014

Journal of Medical Case Reports 1/2014 Zur Ausgabe