Decolonization potential of 0.02% polyhexanide irrigation solution in urethral catheters under practice-like in vitro conditions

verfasst von: Florian H. H. Brill, Henrik Gabriel, Holger Brill, Jan-Hendrik Klock, Joerg Steinmann, Andreas Arndt

Erschienen in: BMC Urology | Ausgabe 1/2018

Abstract

Background

Long-term use of indwelling urethral catheters is associated with high risk of urinary tract infection (UTI) and blockage, which may in turn cause significant morbidity and reduce the life of the catheter. A 0.02% polyhexanide irrigation solution has been developed for routine mechanical rinsing together with bacterial decolonization of suprapubic and indwelling urethral catheters.

Methods

Using a practice-like in vitro assay and standard silicon catheters, artificially contaminated with clinically relevant bacteria, experiments were carried out to evaluate the bacterial decolonization potential of polyhexanide vs. 1) no intervention (standard approach) and 2) irrigation with a saline (NaCl 0.9%) solution. Swabbing and irrigation was used to extract the bacteria.

Results

Irrigation with polyhexanide reduced the microbial population vs. the control catheters by a factor of 1.64 log10 (swab extraction) and by a factor of 2.56 log10 (membrane filtration). The difference in mean microbial counts between the two groups (0.90) was statistically significant in favor of polyhexanide when the liquid extraction method was used (p = 0.034). The difference between the two groups using the swab extraction method did not reach statistical significance.

Conclusions

The saline and polyhexanide solutions are able to reduce bacterial load of catheters, which shows a combined mechanical and antimicrobial effect. Further research is required to evaluate the long-term tolerability and efficacy of polyhexanide in clinical practice.
Abkürzungen
MRSA
Methicillin-resistant Staphylococcus aureus
RF
Reduction factor
UTI
Urinary tract infection

Background

The long-term use of indwelling urethral and suprapubic catheters to manage intractable urinary incontinence and retention is commonplace in both hospital and especially community healthcare settings [19]. Surveys of nursing homes across Europe and the US have shown that between 8 to 10% of residents have indwelling urinary catheters [3, 4]. The long-term catheterization patient population is a heterogeneous group, many of which are elderly people who have chronic disabilities [10, 11]. Long-term catheterization can lead to significant patient morbidity and mortality caused by associated complications [10]. The most common complications that occur are urinary tract infection (UTI) and catheter blockage, which can affect up to 70% of catheterized patients [911]. Enteric pathogens (e.g. Escherichia coli) are most commonly responsible; however, Pseudomonas species, Enterococcus species, Staphylococcus aureus, coagulase-negative staphylococci, Enterobacter species and yeasts are also known to cause infection [12]. Bacteria gain access to the urinary tract either extra- or intraluminally and form biofilm colonies, which may adhere to the catheter surface and drainage bag [1215]. As well as providing a source of infection, biofilm formation is also implicated in encrustation and blockage of catheters [14].
Bacteria within biofilms are morphologically and physiologically different from planktonic bacterial cells and are often resistant to systemic antibiotic treatment, making them difficult to eradicate [13]. However, there is evidence suggesting that physical removal, i.e. mechanical rinsing, is the best method of biofilm elimination, and regular cleansing is required to prevent regrowth of the bacteria [16]. Nevertheless, current guidance does not recommend an active approach for catheter management [17, 18]. The standard clinical approach is not to intervene and therefore removal of the catheter may be the only option [3].
Broad-spectrum antimicrobial agents such as polyhexanide that kill microorganisms have shown to be appropriate agents to use for mechanical rinsing and removal of biofilm across a range of applications [16, 19]. The aim of this study was to investigate whether taking an active approach with a mechanical irrigation with normal saline solution and a combined approach with a polyhexanide solution is efficient for decolonizing urethral catheters. The bactericidal activity of the polyhexanide solution was tested in vitro using a suspension assay. In addition, the bacterial decolonization potential was tested using a practice-like in vitro assay with standard catheters, which were artificially contaminated. The polyhexanide solution and irrigation with a normal saline solution were compared to no intervention (standard approach).

Methods

The decolonization activity of a polyhexanide solution (Uro-Tainer® 0.02% Polyhexanide, B. Braun Medical Ltd., Sempach, Switzerland) and normal saline solution was assessed in the presented study. For the time being polyhexanide is used in wound antiseptics with 0.02% and 0.04% concentration [20]. The 0.02% concentration is recommended for clean wounds. As in the application for transurethral catheter decolonization in most cases clean conditions without blood are expected, the lower concentration has been selected to reduce the risk for irritation in patients.

Bactericidal activity in suspension assay

The suspension tests were performed according to EN 13727 [21] against the following six bacteria strains: Staphylococcus aureus (ATCC 6538), Enterococcus hirae (ATCC 10541), Escherichia coli K12 (ATCC 11229, Proteus mirabilis (ATCC 14153), Pseudomonas aeruginosa (ATCC 15442), Klebsiella pneumoniae (ATCC 16609). The bacteria were incubated for 48 h at 36 ± 1 °C. They were exposed to the polyhexanide solution at 50 and 80% v/v for 5, 15, 30 and 60 min under clean conditions (0.3 g/L bovine serum albumin). A combination of 80 g/L polysorbate 80, 60 g/L saponin, 6 g/L lecithin, 20 g/L sodium dodecyl sulphate in A. dest. was validated and used as neutralizing solution.

Catheter decolonization assay

The test bacteria were Escherichia coli (ATCC 11229), Proteus mirabilis (ATCC 14153) and methicillin-resistant Staphylococcus aureus (MRSA) (ATCC 33592). The devices used in all experiments were 41 cm long transurethral silicon balloon catheters with a nelaton-top, size ch. 18 (B. Braun Melsungen Ltd., Germany).
The experimental set up of the in-vitro decolonization assay was as follows:
  • The catheters were contaminated with 5 ml of a mixed suspension of the test organisms (108 to 109 colony forming units [cfu] per ml simulating worst-case conditions) in caseinpepton-soy bean pepton-bouillon daily for 3 days (Fig. 1).
  • The contaminated catheters were incubated for a total of 72 h at 36 °C ± 1 °C.
  • All catheters were irrigated twice daily with a flow of 400 ml of the synthetic urine (composition according to EN 1616: 25 g/L urea, 9 g/L NaCl, 2.5 g/L Potassium hydrogenorthophosphate, dipotassium hydrogenorthophosphate, 3 g/L ammonium chloride 2 g/L kreatinin, 3 g/L sodium sulphite in A. dest. + 3 g/L % bovine serum albumin [22]) during the incubation period.
  • After incubation and the treatment of the catheter with normal saline or polihexanide or no treatment respectively the catheters were irrigated with 100 ml of neutralizer solution (1 g/L polysorbate 80, 1 g/L lecithine, 1 g/L histidine, 2 g/L Sodium dodecyl sulphate) and the microbial count in the solution was determined by membrane filtration of 50 ml and with serial dilution tests (liquid extraction method).
  • In addition, all catheters were cut with a sterile scalpel and the content of the inner lumen of the catheters was extracted with a sterile cotton swab. The swab was suspended in normal saline solution and the microbial count was determined with a serial dilution assay (swab extraction method).
  • The endpoint, i.e. log10 reduction factor (RF) in microbial count, was calculated for the treatment groups vs. the control no treatment group.
  • The statistical difference between the groups was evaluated by the one-sided unpaired Wilcoxon rank sum test [23].
In the first experiment according to above described methodology a total of 20 contaminated catheters were included. Ten were used as growth control in the no treatment group and 10 were treated with polyhexanide solution by connecting the device to the catheter as described in the instructions for use. After the exposure time of 5 min the microbial count was determined.
The second catheter decolonization experiment was similar to the first experiment. A total of 30 catheters were included. Ten catheters were treated with 100 ml 0.9% NaCl solution with an exposure time of 5 min. Additional 10 catheter were treated with 100 ml of the polihexanide solution with an exposure time of 5 min. The remaining 10 catheters were used as growth control and not treated.

Results

In the suspension test assay according to EN 13727 the polyhexanide solution was shown to have bactericidal activity in vitro against Staphylococcus aureus, Enterococcus hirae, Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis and Klebsiella pneumonia under clean conditions (Table 1).
Table 1
Bactericidal activity of polyhexanide 0.02% solution against different reference strains
Test Sample/ Test Organism Microbial Count Control NO
Ig-reduction factor after minutes
Conc. in %
5
15
30
60
Staphylococcus aureus (ATCC 6538), NO = 7.62
50.00
≥ 7.62
≥ 7.62
≥ 7.62
≥ 7.62
80.00
≥ 7.62
≥ 7.62
≥ 7.62
≥ 7.62
Enterococcus hirae (ATCC 10541), NO = 7.42
50.00
≥ 7.42
≥ 7.42
≥ 7.42
≥ 7.42
80.00
≥ 7.42
≥ 7.42
≥ 7.42
≥ 7.42
Escherichia coli K12 (ATCC 11229), NO = 7.26
50.00
n.c.
≥ 6.56
≥ 7.26
≥ 7.26
80.00
3.93
≥ 7.26
≥ 7.26
≥ 7.26
Proteus mirabilis (ATCC 14153), NO = 7.76
50.00
≥ 7.76
≥ 7.76
≥ 7.76
≥ 7.76
80.00
≥ 7.76
≥ 7.76
≥ 7.76
≥ 7.76
Pseudomonas aeruginosa (ATCC 15442), NO = 7.35
50.00
n.c.
5.58
≥ 7.43
≥ 7.43
80.00
≥ 7.35
≥ 7.43
≥ 7.43
≥ 7.43
Klebsiella pneumonia (ATCC 16609), NO = 7.66
50.00
5.18
≥ 7.66
≥ 7.66
6.96
80.00
≥ 7.66
≥ 7.66
≥ 7.66
6.96
n.c. not calculable
The results of the first catheter decolonization assay are summarized in Fig. 1. The control catheters (standard approach i.e. no intervention) had a mean microbial population of 3.12 log10 (range 2.60–4.31 log10) when measured using the swab extraction method and 3.57 log10 (range 3.06–4.20 log10) when the membrane filtration method was used. The catheters irrigated with the polyhexanide solution had a mean microbial population of 1.47 log10 (range 0.48–2.68 log10) when measured using the swab extraction method and 1.01 log10 (0.30–1.60 log10) when the membrane filtration method was used. The difference in the mean microbial count between the two groups was statistically significant in favor of the polyhexanide solution for both methods of analysis (p = 0.012).
Irrigation of the catheters with the polyhexanide solution reduced the microbial population compared to that of the control catheters by a factor of 1.64 log10 (1.12–2.30 log10) when measured using the swab extraction method and by a factor of 2.56 log10 (1.46–3.20 log10) using the membrane filtration method.
The results of the second catheter decolonization assay are summarized in Table 2. The catheters irrigated with NaCl 0.9% had a mean microbial population of 2.37 log10 (± 0.196) when measured using the swab extraction method and 1.70 log10 (± 0.458) when the membrane filtration method was used. The catheters irrigated with the polyhexanide solution had a mean microbial population of 2.06 log10 (± 0.514) when measured using the swab extraction method and 0.80 log10 (± 0.748) when the membrane filtration method was used. The difference in mean microbial count between the two groups (0.90) was statistically significant in favor of the polyhexanide solution when the liquid extraction method was used (p = 0.034). However, the difference between the two groups using the swab extraction method was not statistically significant (p = 0.173).
Table 2
Catheter decolonization results – polyhexanide 0.02% versus NaCl 0.9%
Catheter
Swab Extraction Method
Membrane Filtration Method
log with NaCl
log with polyhexanide
Difference NaCl –polyhexanide
log with NaCl
log with polyhexanide
Difference NaCl –polyhexanide
1
2.34
2.48
−0.13
1.00
1.00
0.00
2
2.48
1.48
1.00
1.00
1.00
0.00
3
2.48
1.30
1.18
2.00
0.00
2.00
4
2.48
1.48
1.00
2.00
0.00
2.00
5
2.48
1.48
1.00
2.00
2.00
0.00
6
2.48
2.48
0.00
2.00
2.00
0.00
7
2.48
2.48
0.00
1.00
1.00
0.00
8
2.48
2.48
0.00
2.00
1.00
1.00
9
2.08
2.48
−0.40
2.00
0.00
2.00
10
1.90
2.48
−0.57
2.00
0.00
2.00
Mean
2.37
2.06
0.31a
1.70
0.80
0.90b
Standard deviation
0.196
0.514
0.628
0.458
0.748
0.943
No of catheters
10
10
aThe difference between the polyhexanide and NaCl groups is not statistically significant (p = 0.173) for the swab extraction method
bThe difference between the polyhexanide and NaCl groups is statistically significant (p = 0.034) for the liquid extraction method

Discussion

This study has demonstrated that the polyhexanide solution has bactericidal activity in vitro against microorganisms which have been commonly associated with development of UTI in catheterized patients [12, 15]. Furthermore, this is the first in vitro study to demonstrate the potential role of polyhexanide for bacterial decolonization of urinary catheters.
The current literature on bacterial decolonization of urethral catheters is largely restricted to treatment with a range of systemic antibiotic regimens [24]. In a study by Jones et al. it has been shown that MRSA was able to colonize a silastic rubber surface even in the presence of prophylactic vancomycin or rifampicin [25]. Furthermore, other studies have shown that the lowest concentration required to eradicate bacterial biofilm for many antibiotics may exceed the maximum therapeutic dose level [2629].
As an alternative to systemic antibiotic treatment efforts have been made to develop catheters coated with hydrophilic gels or antibacterial agents (such as silver) to prevent bacterial adhesion [30] .However, none of these developments have been shown to resist biofilm formation, especially in patients with Proteus mirabilis UTI [30]. One explanation for this lack of success is that this approach does not involve mechanical rinsing or irrigation.
In comparison to antibiotics and use of coated catheters it is suggested that polyhexanide might provide an effective, non-systemic approach to bacterial decolonization of urinary catheters. Polyhexanide has been successfully used for bacterial decolonization and prevention of biofilm formation in wound management [19, 3135]. In an in vitro study rinsing with polyhexanide solution significantly reduced MRSA biofilm at 48 and 72 h compared to two saline solutions (p < 0.05) [32]. In addition to its bactericidal properties, polyhexanide has also been shown to have anti-adhesive properties due to its chemical nature (i.e. cationic), which may have the potential to help prevent biofilm formation [31].
The present study has shown that mechanical rinsing with 0.9% NaCl solution and a 0.02% solution of polyhexanide was shown to be significantly and consistently more effective at reducing the bacterial colonization of the catheters compared to no intervention (standard approach). However, there was no significant difference seen in microbial count between the polihexanide compared to the control groups when the swab extraction method was used.
The results of this study were achieved in experiments that were designed to replicate practice-like conditions as closely as possible. Silicone catheters used routinely in practice were contaminated with a combination of clinically relevant bacteria (e.g. Proteus mirabilis and MRSA) and a solution of synthetic urine and incubated for several days at body temperature. The polyhexanide solution and the saline solution were used according to the manufacturer’s instructions to rinse the catheters for 5 min as used in clinical practice. However, the study has some limitations: the experiments were performed with only one type of catheter. The inoculation with mixed bacterial strains was not standardized in terms of growth of the included species. The microbial counts of the three test bacteria were not determined separately. Therefore, it is possible that the effect of the treatments is not balanced against all bacteria. Also it is possible that some bacteria turned into viable, but not culturable (VBNC) status especially after antimicrobial treatment. As we used standard test bacteria under laboratory conditions on solid media, it is unlikely but possible that this has influenced the results. In addition, practice-like in vitro conditions cannot replace in vivo studies and therefore the results may not directly translate into the clinical setting. Further research is required to demonstrate the efficacy of the polyhexanide as well as 0.9% NaCl solution across a range of catheter types and materials available in clinical practice. Research is also required in patients to evaluate the tolerability and clinical effectiveness of the polyhexanide solution when used for routine catheter maintenance in the short- and long-term.
In summary, the results of this study have shown that a 0.02% polihexanide and 0.9% NaCl solution is able to significantly reduce bacterial load of catheters, which shows a combined mechanical and antimicrobial effect. Further research is required to demonstrate the tolerability and efficacy of the polyhexanide solution in daily clinical practice.

Competing interest

The study was partially financially supported by B. Braun Medical Ltd. FHHB was an employee for B. Braun Medical Ltd. between 2006 and 2010. AA is an employee of B. Braun Medical Ltd.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Greene T, Kiyoshi-Teo H, Reichert H, Krein S, Saint S. Urinary catheter indications in the United States: results from a national survey of acute care hospitals. Infect Control Hosp Epidemiol. 2014;35:96–8.CrossRef Greene T, Kiyoshi-Teo H, Reichert H, Krein S, Saint S. Urinary catheter indications in the United States: results from a national survey of acute care hospitals. Infect Control Hosp Epidemiol. 2014;35:96–8.CrossRef
2.
Zurück zum Zitat Gokula RR, Hickner JA, Smith MA. Inappropriate use of urinary catheters in elderly patients at a midwestern community teaching hospital. Am J Infect Control. 2004;32:196–9.CrossRefPubMed Gokula RR, Hickner JA, Smith MA. Inappropriate use of urinary catheters in elderly patients at a midwestern community teaching hospital. Am J Infect Control. 2004;32:196–9.CrossRefPubMed
4.
Zurück zum Zitat McNulty C, Freeman E, Smith G, et al. Prevalence of urinary catheterization in UK nursing homes. J Hosp Infect. 2003;55:119–23.CrossRefPubMed McNulty C, Freeman E, Smith G, et al. Prevalence of urinary catheterization in UK nursing homes. J Hosp Infect. 2003;55:119–23.CrossRefPubMed
5.
Zurück zum Zitat Milligan F. Male sexuality and urethral catheterisation: a review of the literature. Nurs Stand. 1999;13:43–7.CrossRefPubMed Milligan F. Male sexuality and urethral catheterisation: a review of the literature. Nurs Stand. 1999;13:43–7.CrossRefPubMed
6.
7.
Zurück zum Zitat Crow R, Mulhall A, Chapman RB. Indwelling catheterization and related nursing practice. J Adv Nurs. 1988;13:489–95.CrossRefPubMed Crow R, Mulhall A, Chapman RB. Indwelling catheterization and related nursing practice. J Adv Nurs. 1988;13:489–95.CrossRefPubMed
8.
Zurück zum Zitat Crow R, Chapman RG, Roe BH, Wilson JA. A study of patients with an indwelling urethral catheter and related nursing practice. In: University of Surrey 1986: nursing practice research unit. Crow R, Chapman RG, Roe BH, Wilson JA. A study of patients with an indwelling urethral catheter and related nursing practice. In: University of Surrey 1986: nursing practice research unit.
9.
Zurück zum Zitat Roe BH, Brocklehurst JC. Study of patients with indwelling catheters. J Adv Nurs. 1987;12:713–8.CrossRefPubMed Roe BH, Brocklehurst JC. Study of patients with indwelling catheters. J Adv Nurs. 1987;12:713–8.CrossRefPubMed
10.
11.
Zurück zum Zitat Khan AA, Mathur S, Feneley R, Timoney AG. Developing a strategy to reduce the high morbidity of patients with long-term urinary catheters: the BioMed catheter research clinic. BJU Int. 2007;100:1298–301.CrossRefPubMed Khan AA, Mathur S, Feneley R, Timoney AG. Developing a strategy to reduce the high morbidity of patients with long-term urinary catheters: the BioMed catheter research clinic. BJU Int. 2007;100:1298–301.CrossRefPubMed
13.
Zurück zum Zitat Costerton JW, Lewandowski Z, Caldwell DE, Korber DR, Lappin-Scott HM. Microbial biofilms. Annu Rev Microbiol. 1995;49:711–45.CrossRefPubMed Costerton JW, Lewandowski Z, Caldwell DE, Korber DR, Lappin-Scott HM. Microbial biofilms. Annu Rev Microbiol. 1995;49:711–45.CrossRefPubMed
14.
Zurück zum Zitat Pratt RJ, Pellowe CM, Wilson JA, et al. epic2: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England. J Hosp Infect. 2007;65(Suppl 1):S1–64.CrossRefPubMed Pratt RJ, Pellowe CM, Wilson JA, et al. epic2: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England. J Hosp Infect. 2007;65(Suppl 1):S1–64.CrossRefPubMed
15.
Zurück zum Zitat Goldsworthy MJH. Gene expression of Pseudomonas aeruginosa and MRSA with a catheter-associated urinary tract infection biofilm model. Biosci Horiz. 2008;1:28–37.CrossRef Goldsworthy MJH. Gene expression of Pseudomonas aeruginosa and MRSA with a catheter-associated urinary tract infection biofilm model. Biosci Horiz. 2008;1:28–37.CrossRef
17.
Zurück zum Zitat Robert Koch Institut. Infection prevention in the home. Recommendations of the Commission for Hospital Hygiene and Infection Production of the Robert Koch institute (RKI). Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2005;48:1061–80.CrossRef Robert Koch Institut. Infection prevention in the home. Recommendations of the Commission for Hospital Hygiene and Infection Production of the Robert Koch institute (RKI). Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2005;48:1061–80.CrossRef
18.
Zurück zum Zitat Conway LJ, Larson EL. Guidelines to prevent catheter-associated urinary tract infection: 1980 to 2010. Heart Lung. 2012;41:271–83.CrossRefPubMed Conway LJ, Larson EL. Guidelines to prevent catheter-associated urinary tract infection: 1980 to 2010. Heart Lung. 2012;41:271–83.CrossRefPubMed
20.
Zurück zum Zitat Egli-Gany D, Brill FHH, Hintzpeter M, Andreé S, Pavel FHH. Evaluation of the antiseptic efficacy and local tolerability of a Polihexanide-based antiseptic on resident skin Flora. Adv Skin Wound Care. 2012;25(9):404–8.CrossRefPubMed Egli-Gany D, Brill FHH, Hintzpeter M, Andreé S, Pavel FHH. Evaluation of the antiseptic efficacy and local tolerability of a Polihexanide-based antiseptic on resident skin Flora. Adv Skin Wound Care. 2012;25(9):404–8.CrossRefPubMed
21.
Zurück zum Zitat DIN EN 13727: Chemical disinfectants and antiseptics - quantitative suspension test for the evaluation of bactericidal activity in the medical area - test method and requirements (phase 2, step 1); German version EN 13727:2012+A2:2015. DIN EN 13727: Chemical disinfectants and antiseptics - quantitative suspension test for the evaluation of bactericidal activity in the medical area - test method and requirements (phase 2, step 1); German version EN 13727:2012+A2:2015.
22.
Zurück zum Zitat EN 1616: Sterile uretheral catheters for single use (includes amendment A1:1999); German version EN 1616:1997 + A1:1999. EN 1616: Sterile uretheral catheters for single use (includes amendment A1:1999); German version EN 1616:1997 + A1:1999.
23.
Zurück zum Zitat European Committee for Standardization. Chemical disinfectants and antiseptics. In: Hygienic handrub. Test method and requirements (phase 2/step 2); German version EN 1500; 1997. European Committee for Standardization. Chemical disinfectants and antiseptics. In: Hygienic handrub. Test method and requirements (phase 2/step 2); German version EN 1500; 1997.
24.
Zurück zum Zitat Buehlmann M, Bruderer T, Frei R, Widmer AF. Effectiveness of a new decolonisation regimen for eradication of extended-spectrum β-lactamase-producing Enterobacteriaceae. J Hosp Infect. 2011;77:113–7.CrossRefPubMed Buehlmann M, Bruderer T, Frei R, Widmer AF. Effectiveness of a new decolonisation regimen for eradication of extended-spectrum β-lactamase-producing Enterobacteriaceae. J Hosp Infect. 2011;77:113–7.CrossRefPubMed
25.
Zurück zum Zitat Jones SM, Morgan M, Humphrey TJ, Lappin-Scott H. Effect of vancomycin and rifampicin on meticillin-resistant Staphylococcus aureus biofilms. Lancet. 2001;357:40–1.CrossRefPubMed Jones SM, Morgan M, Humphrey TJ, Lappin-Scott H. Effect of vancomycin and rifampicin on meticillin-resistant Staphylococcus aureus biofilms. Lancet. 2001;357:40–1.CrossRefPubMed
26.
Zurück zum Zitat Koseoglu H, Aslan G, Esen N, Sen BH, Coban H. Ultrastructural stages of biofilm development of Escherichia coli on urethral catheters and effects of antibiotics on biofilm formation. Urology. 2006;68:942–6.CrossRefPubMed Koseoglu H, Aslan G, Esen N, Sen BH, Coban H. Ultrastructural stages of biofilm development of Escherichia coli on urethral catheters and effects of antibiotics on biofilm formation. Urology. 2006;68:942–6.CrossRefPubMed
27.
Zurück zum Zitat Olson ME, Ceri H, Morck DW, Buret AG, Read RR. Biofilm bacteria: formation and comparative susceptibility to antibiotics. Can J Vet Res. 2002;66:86–92.PubMedPubMedCentral Olson ME, Ceri H, Morck DW, Buret AG, Read RR. Biofilm bacteria: formation and comparative susceptibility to antibiotics. Can J Vet Res. 2002;66:86–92.PubMedPubMedCentral
28.
Zurück zum Zitat Conley J, Olson ME, Cook LS, Ceri H, Phan V, Davies HD. Biofilm formation by group a streptococci: is there a relationship with treatment failure? J Clin Microbiol. 2003;41:4043–8.CrossRefPubMedPubMedCentral Conley J, Olson ME, Cook LS, Ceri H, Phan V, Davies HD. Biofilm formation by group a streptococci: is there a relationship with treatment failure? J Clin Microbiol. 2003;41:4043–8.CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Stickler DJ. Bacterial biofilms and the encrustation of urethral catheters. Biofouling. 1996;9:293–305.CrossRef Stickler DJ. Bacterial biofilms and the encrustation of urethral catheters. Biofouling. 1996;9:293–305.CrossRef
31.
Zurück zum Zitat Afinogenova AG, Grabovskaya KB, Kuleshevich EV, Suvorov AN, Afinogenova AG. Effects of biguanides on the formation of streptococcal biofilms using a human embryo skin fibroblast cell culture. Infect in Surg. 2011;1:5–13. Afinogenova AG, Grabovskaya KB, Kuleshevich EV, Suvorov AN, Afinogenova AG. Effects of biguanides on the formation of streptococcal biofilms using a human embryo skin fibroblast cell culture. Infect in Surg. 2011;1:5–13.
32.
Zurück zum Zitat Perez R, Davies SC, Kaehn K. Effect of different wound rinsing solutions on MRSA biofilm in a porcine wound model. Wund Manage. 2010;4(2):44–8. Perez R, Davies SC, Kaehn K. Effect of different wound rinsing solutions on MRSA biofilm in a porcine wound model. Wund Manage. 2010;4(2):44–8.
33.
Zurück zum Zitat Romanelli M, Dini V, Barbanera S, Bertone MS. Evaluation of the efficacy and tolerability of a solution containing propyl betaine and polyhexanide for wound irrigation. Skin Pharmacol Physiol. 2010;23(Suppl 1):41–4.CrossRefPubMed Romanelli M, Dini V, Barbanera S, Bertone MS. Evaluation of the efficacy and tolerability of a solution containing propyl betaine and polyhexanide for wound irrigation. Skin Pharmacol Physiol. 2010;23(Suppl 1):41–4.CrossRefPubMed
34.
Zurück zum Zitat Moller A, Nolte A, Kaehn K. Experiences with the use of PHMB-containing wound products in the management of chronic wounds — results of a methodical and retrospective analysis of 953 patients. Wund Manage. 2008;3:112–7. Moller A, Nolte A, Kaehn K. Experiences with the use of PHMB-containing wound products in the management of chronic wounds — results of a methodical and retrospective analysis of 953 patients. Wund Manage. 2008;3:112–7.
35.
Zurück zum Zitat Andriessen AE, Eberlein T. Assessment of a wound cleansing solution in the treatment of problem wounds. Wounds. 2008;20(6):171–5.PubMed Andriessen AE, Eberlein T. Assessment of a wound cleansing solution in the treatment of problem wounds. Wounds. 2008;20(6):171–5.PubMed
Metadaten
Titel
Decolonization potential of 0.02% polyhexanide irrigation solution in urethral catheters under practice-like in vitro conditions
verfasst von
Florian H. H. Brill
Henrik Gabriel
Holger Brill
Jan-Hendrik Klock
Joerg Steinmann
Andreas Arndt
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
BMC Urology / Ausgabe 1/2018
Elektronische ISSN: 1471-2490
DOI
https://doi.org/10.1186/s12894-018-0362-3

Weitere Artikel der Ausgabe 1/2018

BMC Urology 1/2018 Zur Ausgabe

Neu im Fachgebiet Urologie

Update Urologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.