Skip to main content
Erschienen in: Critical Care 1/2011

01.02.2011 | Commentary

Defining the boundaries of bedside pulse contour analysis: dynamic arterial elastance

verfasst von: Michael R Pinsky

Erschienen in: Critical Care | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

Assessment of vasomotor tone is essential in defining appropriate resuscitation strategies for the hypotensive patient. Although changes in mean arterial pressure to cardiac output define arterial resistance, resistance is only one component of vasomotor tone. Compliance is the other component. The reciprocal of compliance is arterial elastance (Ea). Importantly, dynamic Ea can be estimated by the pulse pressure variation to stroke volume variation relation. Dynamic Ea is only one component of vasomotor tone, however, and increases in pulse pressure may not be proportional to increases in mean arterial pressure. Also, devices that use the arterial pressure pulse to calculate the stroke volume have an inherent bias that is different amongst devices based on their transfer function algorithms. The use of dynamic Ea for clinical decision-making thus needs to be validated separately for different devices and types of patients.
Literatur
1.
Zurück zum Zitat García MIM, Cano AG, Romero MG: Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Crit Care 2011, 15: R15.CrossRef García MIM, Cano AG, Romero MG: Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Crit Care 2011, 15: R15.CrossRef
2.
Zurück zum Zitat Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL: Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 1999, 159: 935-939.PubMedCrossRef Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL: Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 1999, 159: 935-939.PubMedCrossRef
3.
Zurück zum Zitat Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med 2005, 31: 1195-1201. 10.1007/s00134-005-2731-0PubMedCrossRef Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med 2005, 31: 1195-1201. 10.1007/s00134-005-2731-0PubMedCrossRef
4.
Zurück zum Zitat Hamilton WF, Remington W: The measurement of the stroke volume from the pressure pulse. Am J Physiol 1947, 148: 14-24.PubMed Hamilton WF, Remington W: The measurement of the stroke volume from the pressure pulse. Am J Physiol 1947, 148: 14-24.PubMed
5.
Zurück zum Zitat Kelly RP, Ting CT, Yang TM, Liu CP, Maughan WL, Chang MS, Kass DA: Effective arterial elastance as index of arterial vascular load in humans. Circulation 1992, 86: 513-521.PubMedCrossRef Kelly RP, Ting CT, Yang TM, Liu CP, Maughan WL, Chang MS, Kass DA: Effective arterial elastance as index of arterial vascular load in humans. Circulation 1992, 86: 513-521.PubMedCrossRef
6.
Zurück zum Zitat Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y: Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol 1998, 274: H500-H505.PubMed Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y: Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol 1998, 274: H500-H505.PubMed
7.
Zurück zum Zitat Pinsky MR: Protocolized cardiovascular management based on ventricular-arterial coupling. In Functional Hemodynamic Monitoring. Edited by: Pinsky MR, Payen D. Berlin: Springer-Verlag; 2006:381-395. Pinsky MR: Protocolized cardiovascular management based on ventricular-arterial coupling. In Functional Hemodynamic Monitoring. Edited by: Pinsky MR, Payen D. Berlin: Springer-Verlag; 2006:381-395.
8.
Zurück zum Zitat Hadian M, Severyn D, Pinsky MR: The effects of vasoactive drugs on pulse pressure and stroke volume variation in post-operative ventilated patients. J Crit Care 2010. Hadian M, Severyn D, Pinsky MR: The effects of vasoactive drugs on pulse pressure and stroke volume variation in post-operative ventilated patients. J Crit Care 2010.
9.
Zurück zum Zitat Hadian M, Kim H, Severyn DA, Pinsky MR: Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care 2010, 14: R212. 10.1186/cc9335PubMedPubMedCentralCrossRef Hadian M, Kim H, Severyn DA, Pinsky MR: Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care 2010, 14: R212. 10.1186/cc9335PubMedPubMedCentralCrossRef
Metadaten
Titel
Defining the boundaries of bedside pulse contour analysis: dynamic arterial elastance
verfasst von
Michael R Pinsky
Publikationsdatum
01.02.2011
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2011
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc9986

Weitere Artikel der Ausgabe 1/2011

Critical Care 1/2011 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.