Skip to main content
Erschienen in: Radiation Oncology 1/2018

Open Access 01.12.2018 | Research

Delineation of lung cancer with FDG PET/CT during radiation therapy

verfasst von: J. Ganem, S. Thureau, I. Gardin, R. Modzelewski, S. Hapdey, P. Vera

Erschienen in: Radiation Oncology | Ausgabe 1/2018

Abstract

Objectives

To propose an easily applicable segmentation method (perPET-RT) for delineation of tumour volume during radiotherapy on interim fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in patients with non-small cell lung cancer (NSCLC).

Material and methods

Sixty-seven patients (51 primary tumours, 60 lymph nodes), from 4 prospective studies, underwent an FDG PET/CT scan during the fifth week of radiation therapy, using different generations of PET/CT. Per-therapeutic PET/CT scans were delineated in consensus by two experienced physicians leading to the gold standard threshold to be applied. The mathematical expression of Thopt, the optimal threshold to be applied as a function of the maximum standard uptake value (SUVmax), was determined. The performance of this method (perPET-RT) was assessed by computing the DICE similarity coefficient (DSC) and was compared with 8 fixed threshold values and 3 adaptive thresholding methods.

Results

Thopt verified the following expression: Thopt = A.ln(1/SUVmax) + B where A and B were 2 constants. A and B were independent from the generation of PET/CT, but depended on the type of lesions (primary lung tumours vs. lymph nodes). PerPET-RT showed good to very good agreement in comparison to the gold standard. The mean and standard deviation of DSC value was 0.81 ± 0.13 for lung lesions and 0.78 ± 0.15 for lymph nodes. PerPET-RT showed a significant better agreement than the other segmentation methods (p < 0.001), except for one of the adaptive thresholding method ADT (p = 0.11).

Conclusion

On the database used, perPET-RT has proven its reliability and accuracy for tumour delineation on per-therapeutic FDG PET/CT using only SUVmax measurement. This method may be used to delineate tumour volume for dose-escalation planning.

Trial registration

Abkürzungen
FDG
fluorine 18 fluorodeoxyglucose
MTV
metabolic tumour volume
NSCLC
non-small cell lung cancer
PET/CT
positron emission tomography/computed tomography
SUVmax
the maximum standard uptake value

Introduction

Non-Small Cell Lung Cancer (NSCLC) represents a leading cause of death by cancer in the world, especially in Europe and North America. Treatment modalities should be personalized according to the patient’s clinical condition, tumor staging, histological/molecular profile, whether disease is resectable, locally advanced or advanced and may comprise surgery, radiation therapy and chemotherapy [13].
FDG PET/CT (18F-fluorodeoxyglucose positron emission tomography/computed tomography) has proven utility to accurately to delineate the tumour volume for external radiation therapy [4, 5]. In the case of NSCLC, pre-therapeutic FDG PET/CT allows the delineation of the metabolic tumour volume (MTV), the exclusion of non-tumoral abnormalities (such as atelectasis) and also improves inter and intra observers reproducibility [6, 7], which are one of the main limitations when delineating on CT modality alone.
Several radiation therapy strategies have been considered so far Bradley et al. showed that high dose conformational radiation therapy was not better than standard-dose radiation therapy and even potentially harmful, due to increased toxicity [8].
Current radiotherapy techniques make it possible to deliver a heterogeneous dose by IMRT. FDG PET/CT can help define patients or volumes at risk of recurrence. However, Aerts et al. [9] and Calais et al. [10] showed that high FDG uptake areas on pre-therapeutic FDG PET/CT scans were highly correlated to the sites of local relapse or persistent abnormalities on post-therapeutic scans. These findings lead to consider the idea of dose-escalation on a smaller volume, allowing a better local control of the disease and minimising in parallel early and late toxicity.
The FDG PET/CT fixing per-treatment can also be a volume of interest. Per-radiotherapy FDG PET/CT can be performed without artefacts (lung inflammation) and the persistence of 42Gy fixation is very pejorative [11, 12]. As a result, we proposed a French multicenter study with dose increase on per-radiotherapy FDG volume (RTEP7, NCT02473133). Another study is also underway in the USA by the RTOG (RTOG 1106) and encouragingpreliminary results have been published by Kongs et al. in a phase 2 [13].
The definition of BTV (Biologic Target Volume) is a crucial step of treatment planning in radiation therapy. Many methods of pre-treatment segmentation have been defined but there is no segmentation method in the process of radiotherapy. For Until now, manual delineation of FDG PET positive tissues is the gold standard, despite poor reproducibility [14].
For pre-radiotherapy, many methods have been proposed in the literature. The first methods are a fixed standard uptake value (SUV), for example 2.5 [15, 16] or a threshold value around 40% of the maximum standard uptake value (SUVmax) within the lesion [16, 17]. The last recommendations, published by the European Association of Nuclear Medicine (EANM), suggested a delineation of the MTV by applying 3D isocontours at 41% or 50% of SUVmax [5, 18, 19].
However, these methods are not optimal for low contrast or small volumes [20]. which can be the case on per-therapeutic PET/CT images. Thus, several complex methods have been developed [1829]. None of them has proven its superiority yet [30]. This absence of consensus can be a problem in multicentre trials, where acquisition reproducibility is poor and devices correspond to different PET/CT models, possibly from different generation technologies. Another limitation comes from the availability of delineation softwares, especially in case of sophisticated approaches.
The aim of this article is to propose a reliable, reproducible and easy delineation method applicable in clinical routine and suitable for multicentre studies, in the specific context of per-therapeutic FDG PET/CT with potentially small volume and low contrast. This step was a prerequisite for the RTEP7 study.

Material and methods

Patient population and treatment

Data were extracted from 4 prospective studies corresponding to a total of 67 patients, respectively S1, S2, S3 and S4, where S1–3 correspond to monocentric clinical trials (Centre Henri Becquerel, Rouen, France) [11, 12, 31] (NCT01261598, NCT01261585) and S4 (NCT01576796) an ongoing multicentre clinical trial study [31], in which patients had given written and informed consent. All patients were treated with radiation therapy alone or concomitant chemoradiotherapy for inoperable stage II or III NSCLC. Patients were treated by conformational radiation therapy. The dose prescription corresponded to 66 Gy in 33 fractions, with 2 Gy per fraction given daily, 5 days a week. The mean age was 59 years. There were 13 women and 54 men presenting stage II (10%) or stage III (90%) NSCLC. Clinical data are summarized in Table 1.
Table 1
Clinical, pathological and therapeutic data
Number of patients
67
Age (years)
Mean: 59 (min 38; max 80)
Sex (number of patients)
Women: 13; Men: 54
Tumoral stage:
 - II A
2
 - II B
5
 - III A
25
 - III B
35
Histology:
 - Adenocarcinoma
24 (5 poorly differentiated)
 - Squamous cell carcinoma
37
 - Undifferentiated carcinoma
6
Type of treatment:
 - Radiation therapy
21
 - Concomitant radiochemotherapy
46
Dose received before per-therapeutic PET/CT
Mean: 43 Gy (min: 32 Gy; max: 52 Gy)

PET/CT imaging

For patients treated at the Centre Henri Becquerel, the per-therapeutic PET/CT was performed on a Biograph Sensation 16 Hi-Rez device (Siemens Medical Solutions, Erlangen, Germany), without time of flight system or image reconstruction algorithm incorporating point-spread function. Forty-six patients underwent their PET/CT on this device. They were unrolled in S1–3 monocentric clinical trials (39 patients), and in S4 (7 patients). As the PET/CT device corresponded to an old generation model, these patients were grouped into a database called Sold.
Patients who underwent their FDG PET/CT on a new generation of positron-emission tomograph came from S4 study. All the image reconstruction algorithms incorporated a point-spread function, while some of them used a time of flight system (ToF). They were grouped into a database called SNew (21 patients). The PET/CT models and their characteristics are listed in Appendix.
All 67 patients underwent a FDG PET/CT during the fifth week of radiation therapy. Protocols of acquisition and reconstruction followed EANM procedure guidelines [5], but they were inherent to each nuclear medicine department. On the other hand, they were the same for a given device.

PET/CT analysis

First, per-therapeutic PET/CT scans were delineated in consensus using a Planet Onco workstation (PlanetOnco, v.2.0; DOSISoft) at the Centre Henri Becquerel (Rouen, France) by two experienced physicians of the same center: one nuclear medicine physician and one radiation oncologist with clinical practice in lung cancer. The delineation was performed using different thresholds until the volume corresponded with the one obtained by manual delineation, leading to ThGStd, the gold standard threshold. SUVmax of the lesion was also extracted leading to (ThGStd, SUVmax) pairs of values.
Then, primary lung tumours (pr) were isolated from lymph nodes (no), leading to 4 classes of lesions: SOld(pr), SNew(pr), SOld(no) and SNew(no) lesions.

PerPET-RT segmentation method

The graphical representation of y (ThGStd) as a function of x (SUVmax) showed that the shape of the curve could be approximated as the natural logarithm of the reciprocal of x.
The method proposed to easily segment the MTV on a per-therapeutic PET/CT during the fifth week of treatment of NSCLC, called perPET-RT, is based on an adaptive thresholding method according to the following expression:
Thopt = A. ln(1/SUVmax) + B Eq. 1.
where Thopt(%) is the optimal threshold to be applied, SUVmax the maximum of the SUV in the tumour (primary or node) to be segmented, and A and B, two constants depending on the kind of lesion (primary or node) leading respectively to (Apr, Bpr) and (Ano, Bno).
One can note that Eq. 1 corresponds to a linear relationship between Thopt and X = ln(1/SUVmax), where A is the slope of the line and B the intercept, leading to the following expression:
Thopt = A. X + B Eq. 2.

Segmentation methods for performance comparison

The performance of perPET-RT was compared to several segmentation methods, based on thresholding, applied by a third experienced physician, independently from the consensual delineation used for the gold standard:
  • Fixed SUV-values: 2; 2.5; 3; 3.5;
  • Fixed threshold corresponding to a percentile of the maximum SUV (% of SUVmax): 40, 50, 60, 70%;
  • An adaptive thresholding method, called AOV, where the threshold to be applied corresponds to 1.5 times the mean SUV measured in an aorta volume of 1 cc [21];
  • Two adaptive thresholding methods: COA and ADT [20, 22]. The two methods were calibrated according to the recommendations respectively from Schaefer et al. [20] and Vauclin et al. [23] for Biograph Sensation 16 Hi-Rez device.

Data analysis

Regression function of perPET-RT

For primary tumours and nodes, the couples of values (Thopt, SUVmax) were defined, as well as the associated couple of constants (i. e. (Apr, Bpr) and (Ano, Bno)) of the linear regression (Eq. 2). The fits were obtained by minimizing the residuals by computing their coefficient of determination (R2).
The robustness of the adaptive threshold calibration procedure was evaluated by testing whether the slopes and the intercepts of the two datasets issued from the two PET models (old vs. new) were significantly different [33].
First, slopes were compared. If this first p-value was less than 0.05, it could be concluded that the lines were significantly different. In that case, there was no point in comparing the intercepts. Otherwise, intercepts were compared. If this second p-value was high, there was no compelling evidence that the lines were different. The software used was GraphPad Prism 5 (Version 5.0 SAS Institute Inc., CA, USA).

Agreement of segmented volumes

The performance of perPET-RT method was evaluated using the Dice similarity coefficient (DSC) according to the following expression:
\( DSC=\frac{2\left(X\cap Y\right)}{\left(X\cup Y\right)} \) Eq. 3.
Where X corresponds to the gold standard volume and Y the volume segmented by perPET-RT.
The agreement between the segmented volumes using other segmentation methods was also performed using DSC.
As two adaptive thresholding methods (ADT and COA) were calibrated only on the Biograph Sensation 16 Hi-Rez device, the segmentation was only done on Sold data for these 2 methods.
At, first a descriptive analysis of DSC was performed for each segmentation method by computing median (DSCmed), minimum (DSCmin) and maximum (DSCmax) of DSC. For this analysis, first/third quartiles and first/ninth deciles of DSC-values were also extracted leading to the estimation of the inter-quartile range (difference between third and first quartiles, i.e. including 50% of the data) and the inter-decile range (difference between ninth and first deciles, i.e. including 80% of the data. Box and Whiskers plots were established. In order to compare the segmentation methods, a non-parametric analysis of DSC was performed. A p-value less than 0.05 was considered to be statistically significant. A Bonferonni post-hoc test was used.
The following criteria for the Cohen κ test were chosen to qualify the agreement of the segmentation methods: 0–0.2, poor agreement; 0.21–0.40, fair agreement; 0.41–0.60, moderate agreement; 0.61–0.80, good agreement; and 0.81–1.00, very good agreement (21).

Results

Per-therapeutic PET results

Patients underwent per-therapeutic PET/CT after a mean dose of 43 Gy (see Table 1). Sixty-one of the 67 patients (91%) had persistent hypermetabolic lesions on these scans, but MTV and SUVmax were lower on PET/CT during the treatment if compared to those of pre-therapeutic PET/CT. An example is given in Fig. 1.
A total of 111 lesions were identified: 51 lung tumours and 60 mediastinal nodes. Their main characteristics such as metabolic volume, SUVmax and threshold applied by the experts for delineation are reported in Table 2.
Table 2
Metabolic characteristics of primary tumours (pr) and involved lymph nodes (no), FDG uptake, threshold used by the experts for metabolic tumour volume delineation and corresponding volume. New and Old refer to the generation of PET device
 
SUVmax range
SUVmax Mean/Median
Thresholds range (%SUVmax)
Thresholds Mean/Median (%SUVmax)
Volumes range (cc)
Volumes Mean/Median (cc)
SOld(pr) (n = 32)
2.5–14.1
6.2/5.8
34–66
50/50
0.26–65
12/17
SOld(no) (n = 38)
2.4–8.4
4.6/4.6
46–73
60/59
0.26–13
3/2
SNew(pr) (n = 19)
2.5–36.5
10.5/8.0
16–65
43/44
0.47–140
20/10
SNew(no) (n = 22)
2.6–9.3
5.4/4.6
44–71
57/59
0.57–25
4.5/1.5

Regression function

In Fig. 2, are given the pairs of points (ThGStd,Ln (1/SUVmax)) for both primary tumours and nodes. This Fig. 2 shows also the plots corresponding to the two linear regressions (primary vs. nodes). There was no statistical difference between slopes. However, a significant difference existed between their intercepts (p < 0.01). On the other hand, for a given type of lesion, no significant difference was found between the lines obtained with the old and the new generation PET/CT devices.

Agreement of segmented volumes

In Fig. 3a are given the descriptive statistics of perPET-RT and the other segmentation methods (AOV, fixed threshold methods) using all the lesions. The segmentation with perPET-RT showed a good to a very good agreement with respect to the experts since the mean value and standard deviation of DSC were 0.78 ± 0.15 for mediastinal lymph nodes and 0.81 ± 0.13 for lung tumours. In Fig. 3b are also given the descriptive statistics of perPET-RT and ADT and COA, but only on the 70 lesions observed on the Biograph Hi-Rez device.
PerPET-RT showed a significant better agreement compared to the other segmentation methods (p < 0.001), except for ADT (p = 0.11) which showed a DSC mean value and standard deviation of 0.75 ± 0.17.

Discussion

With this study, we propose a perPET-RT segmentation method easy to use and adapted to multicentre studies. There are no reference methods for segmentation during radiotherapy, but standard techniques may overestimate target volumes (low fixation during the treatment). The method proposed in the present study, with data extracted from 4 prospective studies, is satisfying, with good to very good agreement when compared to manual delineation during radiation therapy.
This study has several limitations. We have a limited number of patients because all patients had to have a per-radiotherapy PET/CT with persistent 42Gy fixation. If you want to increase the dose to a low volume, it is important to define it precisely and the use of 4D PET could be interesting in this context. All patients were included in studies in which 4D PET was not requested. However, the large volumes or node volumes in the case of radiochemotherapy are not very mobile.
With this method, only one dose level is possible but dose painting techniques could be interesting with heterogeneous doses depending on the FDG fixation. The dose painting could take into account the dose in relation to the FDG fixation but also the dose to be delivered to organs at risk, particularly for lymph node fixation.
Despite combination of chemotherapy and radiation therapy, survival rates remain poor for stage III NSCLC [34, 35]. Patients with locally advanced NSCLC have a very high risk of relapse and/or progression leading to death within the year if they express high metabolic profiles on a per-therapeutic PET/CT scans performed during the fifth week of radiation therapy [12]. The dose-escalation on a smaller volume delineated on the per-therapeutic PET/CT is aiming for a better local control of the disease and to avoid exacerbated early and late toxicity. Nevertheless, this concept is altered the lack of available FDG PET segmentation methods in clinical routine adapted to per-therapeutic FDG PET/CT (around 43 Gy). A randomized phase II dose-escalation trial demonstrated the feasibility of significant dose-escalation on the primary tumour or the high FDG uptake subvolume of the primary tumour without violating the dose constraints for the organs at risk [36]. Dose-escalation planning based on interim FDG PET/CT scans (around 50 Gy of radiation therapy) is feasible, but none of the semi-automatic segmenting tools (including threshold of 2.5, 40% of SUVmax or AOV method) seemed reliable to define volumes correctly [37]. All the methods developed have essentially been developed for tumors more than for lymph node fixation and for tumors before treatment. Radiation therapy modifies the tumor to background ratio. In our study, there was a good agreement between the different methods, but the perPET-RT method had the best agreement with the experts. The ADT method was not significantly different from our method, this is probably due to the fact that it was developed specifically for lung cancers as in our case.
In addition, ongoing clinical trials are evaluating the impact of dose escalation on progression-free survival and overall survival. One of them [32] proposes to increase the dose to hypoxic tumoral areas. Another current clinical trial, lead by the RTOG group, seeks to determine if the dose to the tumour can be increased when a personalized radiation treatment is planned with a PET/CT scan acquired at 40–46 Gy of radiotherapy in patients with inoperable or unresectable stage III NSCLC. The method used for tumoral volume delineation corresponds to the AOV method [38].
PerPET-RT is one of the thresholding-based approaches which are the most widely available techniques in clinical routine. It requires knowing the type of lesion (primary or node) and the measurement of SUVmax, which is, in practice, easier and more reproducible than thresholding methods based on contrast (COA and ADT) or a mean SUV measurement (AOV). Another advantage of perPET-RT is that there is no need to calibrate the method on PET/CT models, unlike many adaptive thresholding methods. In our database, the method was not sensitive to the generation of PET models. This result has to be confirmed on other databases. Nevertheless, the concept of using such an approach in clinical routine or in mono or multicentre clinical trials is possible and easy to implement. As gold standard, a consensus threshold value was used. Palie et al. showed that there was an excellent reproducibility in delineation of MTVs by the physicians [39]. In addition, a recently published study demonstrated the added value of consensus methods in delineation [23]. PerPET-RT was compared with other thresholding methods (fixed or adaptive) due to the ease of use of these techniques. On the other hand, more sophisticated algorithms were not used due to the lack of availability in the context of multicenter clinical trials.
The clinical impact of dose-escalation on the volumes defined by this method is yet to be evaluated by a recently started multicentre clinical trial [40].

Conclusion

PerPET-RT, a thresholding-based approach, was proposed and validated on 4 prospective studies. We have showed that this method is reliable, easy to use and accurate for tumoral delineation on per-therapeutic FDG PET/CT. This method may be used to delineate tumoral volumes for dose-escalation planning. A clinical trial evaluating the impact of dose-escalation radiation therapy in NSCLC has already started in France (PHRC 2014, IFCT 1402-RTEP7).

Acknowledgements

Not applicable.

Funding

Not applicable.

Availability of data and materials

All the data are available in our center.

Disclosure

No potential conflict of interest relevant for this article was reported.
All data were extracted from 4 prospective studies (NCT01261598, NCT01261585) (NCT01576796). For all patients, we are a consent.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Anhänge

Appendix

Table 3
New generation PET/CT devices with their respective system characteristics and the number of patients per device
Type of PET/CT device
Constructor
Number of patients and lesions (tumor, node)
Reconstruction algorithm with point-spread function
ToF system
Gemini TF
Philips
3 (2, 4)
Yes
Yes
GE 690
General Electrics
8 (8, 12)
Yes
Yes
Biograph mCT 40
Siemens
4 (3, 2)
Yes
Yes
Biograph 6
Siemens
4 (4, 1)
Yes
No
Biograph mCT
Siemens
2 (2, 3)
Yes
Yes
Literatur
2.
Zurück zum Zitat Albain KS, Swann RS, Rusch VW, Turrisi AT, Shepherd FA, Smith C, et al. Radiotherapy plus chemotherapy with or without surgical resection for stage III non-small-cell lung cancer: a phase III randomised controlled trial. Lancet Lond Engl. 2009;374(9687):379–86.CrossRef Albain KS, Swann RS, Rusch VW, Turrisi AT, Shepherd FA, Smith C, et al. Radiotherapy plus chemotherapy with or without surgical resection for stage III non-small-cell lung cancer: a phase III randomised controlled trial. Lancet Lond Engl. 2009;374(9687):379–86.CrossRef
3.
Zurück zum Zitat Goldstraw P, Ball D, Jett JR, Le Chevalier T, Lim E, Nicholson AG, et al. Non-small-cell lung cancer. Lancet Lond Engl. 2011;378(9804):1727–40.CrossRef Goldstraw P, Ball D, Jett JR, Le Chevalier T, Lim E, Nicholson AG, et al. Non-small-cell lung cancer. Lancet Lond Engl. 2011;378(9804):1727–40.CrossRef
4.
Zurück zum Zitat Jarritt PH, Carson KJ, Hounsell AR, Visvikis D. The role of PET/CT scanning in radiotherapy planning. Br J Radiol sept 2006;79 Spec No 1:S27–S35.CrossRef Jarritt PH, Carson KJ, Hounsell AR, Visvikis D. The role of PET/CT scanning in radiotherapy planning. Br J Radiol sept 2006;79 Spec No 1:S27–S35.CrossRef
5.
Zurück zum Zitat Boellaard R, Delgado-Bolton R, Oyen WJG, Giammarile F, Tatsch K, Eschner W, et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015;42(2):328–54.CrossRef Boellaard R, Delgado-Bolton R, Oyen WJG, Giammarile F, Tatsch K, Eschner W, et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging. 2015;42(2):328–54.CrossRef
6.
Zurück zum Zitat van Baardwijk A, Bosmans G, Boersma L, Buijsen J, Wanders S, Hochstenbag M, et al. PET-CT-based auto-contouring in non-small-cell lung cancer correlates with pathology and reduces interobserver variability in the delineation of the primary tumor and involved nodal volumes. Int J Radiat Oncol Biol Phys. 2007;68(3):771–8.CrossRef van Baardwijk A, Bosmans G, Boersma L, Buijsen J, Wanders S, Hochstenbag M, et al. PET-CT-based auto-contouring in non-small-cell lung cancer correlates with pathology and reduces interobserver variability in the delineation of the primary tumor and involved nodal volumes. Int J Radiat Oncol Biol Phys. 2007;68(3):771–8.CrossRef
7.
Zurück zum Zitat Schreurs LMA, Busz DM, Paardekooper GMRM, Beukema JC, Jager PL, Van der Jagt EJ, et al. Impact of 18-fluorodeoxyglucose positron emission tomography on computed tomography defined target volumes in radiation treatment planning of esophageal cancer: reduction in geographic misses with equal inter-observer variability: PET/CT improves esophageal target definition. Dis Esophagus Off J Int Soc Dis Esophagus ISDE. 2010;23(6):493–501.CrossRef Schreurs LMA, Busz DM, Paardekooper GMRM, Beukema JC, Jager PL, Van der Jagt EJ, et al. Impact of 18-fluorodeoxyglucose positron emission tomography on computed tomography defined target volumes in radiation treatment planning of esophageal cancer: reduction in geographic misses with equal inter-observer variability: PET/CT improves esophageal target definition. Dis Esophagus Off J Int Soc Dis Esophagus ISDE. 2010;23(6):493–501.CrossRef
8.
Zurück zum Zitat Bradley JD, Paulus R, Komaki R, Masters G, Blumenschein G, Schild S, et al. Standard-dose versus high-dose conformal radiotherapy with concurrent and consolidation carboplatin plus paclitaxel with or without cetuximab for patients with stage IIIA or IIIB non-small-cell lung cancer (RTOG 0617): a randomised, two-by-two factorial phase 3 study. Lancet Oncol. 2015;16(2):187–99.CrossRef Bradley JD, Paulus R, Komaki R, Masters G, Blumenschein G, Schild S, et al. Standard-dose versus high-dose conformal radiotherapy with concurrent and consolidation carboplatin plus paclitaxel with or without cetuximab for patients with stage IIIA or IIIB non-small-cell lung cancer (RTOG 0617): a randomised, two-by-two factorial phase 3 study. Lancet Oncol. 2015;16(2):187–99.CrossRef
9.
Zurück zum Zitat Aerts HJWL, van Baardwijk AAW, Petit SF, Offermann C, van LJ, Houben R, et al. Identification of residual metabolic-active areas within individual NSCLC tumours using a pre-radiotherapy (18) Fluorodeoxyglucose-PET-CT scan. Radiother Oncol J Eur Soc Ther Radiol Oncol. 2009;91(3):386–92.CrossRef Aerts HJWL, van Baardwijk AAW, Petit SF, Offermann C, van LJ, Houben R, et al. Identification of residual metabolic-active areas within individual NSCLC tumours using a pre-radiotherapy (18) Fluorodeoxyglucose-PET-CT scan. Radiother Oncol J Eur Soc Ther Radiol Oncol. 2009;91(3):386–92.CrossRef
10.
Zurück zum Zitat Calais J, Thureau S, Dubray B, Modzelewski R, Thiberville L, Gardin I, et al. Areas of high 18F-FDG uptake on preradiotherapy PET/CT identify preferential sites of local relapse after chemoradiotherapy for non-small cell lung cancer. J Nucl Med Off Publ Soc Nucl Med. 2015;56(2):196–203. Calais J, Thureau S, Dubray B, Modzelewski R, Thiberville L, Gardin I, et al. Areas of high 18F-FDG uptake on preradiotherapy PET/CT identify preferential sites of local relapse after chemoradiotherapy for non-small cell lung cancer. J Nucl Med Off Publ Soc Nucl Med. 2015;56(2):196–203.
11.
Zurück zum Zitat Edet-Sanson A, Dubray B, Doyeux K, Back A, Hapdey S, Modzelewski R, et al. Serial assessment of FDG-PET FDG uptake and functional volume during radiotherapy (RT) in patients with non-small cell lung cancer (NSCLC). Radiother Oncol J Eur Soc Ther Radiol Oncol. 2012;102(2):251–7.CrossRef Edet-Sanson A, Dubray B, Doyeux K, Back A, Hapdey S, Modzelewski R, et al. Serial assessment of FDG-PET FDG uptake and functional volume during radiotherapy (RT) in patients with non-small cell lung cancer (NSCLC). Radiother Oncol J Eur Soc Ther Radiol Oncol. 2012;102(2):251–7.CrossRef
12.
Zurück zum Zitat Vera P, Mezzani-Saillard S, Edet-Sanson A, Ménard J-F, Modzelewski R, Thureau S, et al. FDG PET during radiochemotherapy is predictive of outcome at 1 year in non-small-cell lung cancer patients: a prospective multicentre study (RTEP2). Eur J Nucl Med Mol Imaging. 2014;41(6):1057–65.CrossRef Vera P, Mezzani-Saillard S, Edet-Sanson A, Ménard J-F, Modzelewski R, Thureau S, et al. FDG PET during radiochemotherapy is predictive of outcome at 1 year in non-small-cell lung cancer patients: a prospective multicentre study (RTEP2). Eur J Nucl Med Mol Imaging. 2014;41(6):1057–65.CrossRef
14.
Zurück zum Zitat Hatt M, Visvikis D. Defining radiotherapy target volumes using 18F-fluoro-deoxy-glucose positron emission tomography/computed tomography: still a Pandora’s box?: in regard to Devic et al. (Int J Radiat Oncol Biol Phys 2010). Int J Radiat Oncol Biol Phys. 2010;78(5):1605. Hatt M, Visvikis D. Defining radiotherapy target volumes using 18F-fluoro-deoxy-glucose positron emission tomography/computed tomography: still a Pandora’s box?: in regard to Devic et al. (Int J Radiat Oncol Biol Phys 2010). Int J Radiat Oncol Biol Phys. 2010;78(5):1605.
15.
Zurück zum Zitat Paulino AC, Johnstone PAS. FDG-PET in radiotherapy treatment planning: Pandora’s box? Int J Radiat Oncol Biol Phys. 2004;59(1):4–5.CrossRef Paulino AC, Johnstone PAS. FDG-PET in radiotherapy treatment planning: Pandora’s box? Int J Radiat Oncol Biol Phys. 2004;59(1):4–5.CrossRef
16.
Zurück zum Zitat Nestle U, Schaefer-Schuler A, Kremp S, Groeschel A, Hellwig D, Rübe C, et al. Target volume definition for 18F-FDG PET-positive lymph nodes in radiotherapy of patients with non-small cell lung cancer. Eur J Nucl Med Mol Imaging. 2007;34(4):453–62.CrossRef Nestle U, Schaefer-Schuler A, Kremp S, Groeschel A, Hellwig D, Rübe C, et al. Target volume definition for 18F-FDG PET-positive lymph nodes in radiotherapy of patients with non-small cell lung cancer. Eur J Nucl Med Mol Imaging. 2007;34(4):453–62.CrossRef
17.
Zurück zum Zitat Erdi YE, Mawlawi O, Larson SM, Imbriaco M, Yeung H, Finn R, et al. Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer. 1997;80(12 Suppl):2505–9.CrossRef Erdi YE, Mawlawi O, Larson SM, Imbriaco M, Yeung H, Finn R, et al. Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer. 1997;80(12 Suppl):2505–9.CrossRef
18.
Zurück zum Zitat Boellaard R, Krak NC, Hoekstra OS, Lammertsma AA. Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study. J Nucl med off Publ Soc. Nucl Med. 2004;45(9):1519–27. Boellaard R, Krak NC, Hoekstra OS, Lammertsma AA. Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study. J Nucl med off Publ Soc. Nucl Med. 2004;45(9):1519–27.
19.
Zurück zum Zitat Krak NC, Boellaard R, Hoekstra OS, Twisk JWR, Hoekstra CJ, Lammertsma AA. Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial. Eur J Nucl Med Mol Imaging. 2005;32(3):294–301.CrossRef Krak NC, Boellaard R, Hoekstra OS, Twisk JWR, Hoekstra CJ, Lammertsma AA. Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial. Eur J Nucl Med Mol Imaging. 2005;32(3):294–301.CrossRef
20.
Zurück zum Zitat Doyeux K, Vauclin S, Hapdey S, Daouk J, Edet-Sanson A, Vera P, et al. Reproducibility of the adaptive thresholding calibration procedure for the delineation of 18F-FDG-PET-positive lesions. Nucl Med Commun may. 2013;34(5):432–8.CrossRef Doyeux K, Vauclin S, Hapdey S, Daouk J, Edet-Sanson A, Vera P, et al. Reproducibility of the adaptive thresholding calibration procedure for the delineation of 18F-FDG-PET-positive lesions. Nucl Med Commun may. 2013;34(5):432–8.CrossRef
21.
Zurück zum Zitat Schaefer A, Kremp S, Hellwig D, Rübe C, Kirsch C-M, Nestle U. A contrast-oriented algorithm for FDG-PET-based delineation of tumour volumes for the radiotherapy of lung cancer: derivation from phantom measurements and validation in patient data. Eur J Nucl Med Mol Imaging. 2008;35(11):1989–99.CrossRef Schaefer A, Kremp S, Hellwig D, Rübe C, Kirsch C-M, Nestle U. A contrast-oriented algorithm for FDG-PET-based delineation of tumour volumes for the radiotherapy of lung cancer: derivation from phantom measurements and validation in patient data. Eur J Nucl Med Mol Imaging. 2008;35(11):1989–99.CrossRef
22.
Zurück zum Zitat Thureau S, Chaumet-Riffaud P, Modzelewski R, Fernandez P, Tessonnier L, Vervueren L, et al. Interobserver agreement of qualitative analysis and tumor delineation of 18F-fluoromisonidazole and 3′-deoxy-3’-18F-fluorothymidine PET images in lung cancer. J Nucl Med Off Publ Soc Nucl Med. 2013;54(9):1543–50. Thureau S, Chaumet-Riffaud P, Modzelewski R, Fernandez P, Tessonnier L, Vervueren L, et al. Interobserver agreement of qualitative analysis and tumor delineation of 18F-fluoromisonidazole and 3′-deoxy-3’-18F-fluorothymidine PET images in lung cancer. J Nucl Med Off Publ Soc Nucl Med. 2013;54(9):1543–50.
23.
Zurück zum Zitat Schaefer A, Vermandel M, Baillet C, Dewalle-Vignion AS, Modzelewski R, Vera P, et al. Impact of consensus contours from multiple PET segmentation methods on the accuracy of functional volume delineation. Eur J Nucl Med Mol Imaging. 2016;43(5):911–24.CrossRef Schaefer A, Vermandel M, Baillet C, Dewalle-Vignion AS, Modzelewski R, Vera P, et al. Impact of consensus contours from multiple PET segmentation methods on the accuracy of functional volume delineation. Eur J Nucl Med Mol Imaging. 2016;43(5):911–24.CrossRef
24.
Zurück zum Zitat Vauclin S, Doyeux K, Hapdey S, Edet-Sanson A, Vera P, Gardin I. Development of a generic thresholding algorithm for the delineation of 18FDG-PET-positive tissue: application to the comparison of three thresholding models. Phys med biol. 2009;54(22):6901.CrossRef Vauclin S, Doyeux K, Hapdey S, Edet-Sanson A, Vera P, Gardin I. Development of a generic thresholding algorithm for the delineation of 18FDG-PET-positive tissue: application to the comparison of three thresholding models. Phys med biol. 2009;54(22):6901.CrossRef
25.
Zurück zum Zitat Geets X, Lee JA, Bol A, Lonneux M, Grégoire V. A gradient-based method for segmenting FDG-PET images: methodology and validation. Eur J Nucl Med Mol Imaging. 2007;34(9):1427–38.CrossRef Geets X, Lee JA, Bol A, Lonneux M, Grégoire V. A gradient-based method for segmenting FDG-PET images: methodology and validation. Eur J Nucl Med Mol Imaging. 2007;34(9):1427–38.CrossRef
26.
Zurück zum Zitat Onoma DP, Ruan S, Thureau S, Nkhali L, Modzelewski R, Monnehan GA, et al. Segmentation of heterogeneous or small FDG PET positive tissue based on a 3D-locally adaptive random walk algorithm. Comput Med Imaging Graph Off J Comput Med Imaging Soc dec. 2014;38(8):753–63.CrossRef Onoma DP, Ruan S, Thureau S, Nkhali L, Modzelewski R, Monnehan GA, et al. Segmentation of heterogeneous or small FDG PET positive tissue based on a 3D-locally adaptive random walk algorithm. Comput Med Imaging Graph Off J Comput Med Imaging Soc dec. 2014;38(8):753–63.CrossRef
27.
Zurück zum Zitat Belhassen S, Zaidi H. A novel fuzzy C-means algorithm for unsupervised heterogeneous tumor quantification in PET. Med Phys mar. 2010;37(3):1309–24.CrossRef Belhassen S, Zaidi H. A novel fuzzy C-means algorithm for unsupervised heterogeneous tumor quantification in PET. Med Phys mar. 2010;37(3):1309–24.CrossRef
28.
Zurück zum Zitat Dewalle-Vignion A-S, Betrouni N, Lopes R, Huglo D, Stute S, Vermandel M. A new method for volume segmentation of PET images, based on possibility theory. IEEE Trans Med Imaging. 2011;30(2):409–23.CrossRef Dewalle-Vignion A-S, Betrouni N, Lopes R, Huglo D, Stute S, Vermandel M. A new method for volume segmentation of PET images, based on possibility theory. IEEE Trans Med Imaging. 2011;30(2):409–23.CrossRef
29.
Zurück zum Zitat Hatt M, Cheze le Rest C, Turzo A, Roux C, Visvikis D. A fuzzy locally adaptive Bayesian segmentation approach for volume determination in PET. IEEE Trans Med Imaging 2009;28(6):881–893.CrossRef Hatt M, Cheze le Rest C, Turzo A, Roux C, Visvikis D. A fuzzy locally adaptive Bayesian segmentation approach for volume determination in PET. IEEE Trans Med Imaging 2009;28(6):881–893.CrossRef
30.
Zurück zum Zitat Zaidi H, El Naqa I. PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging. 2010;37(11):2165–87.CrossRef Zaidi H, El Naqa I. PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging. 2010;37(11):2165–87.CrossRef
31.
Zurück zum Zitat Vera P, Bohn P, Edet-Sanson A, Salles A, Hapdey S, Gardin I, et al. Simultaneous positron emission tomography (PET) assessment of metabolism with 18F-fluoro-2-deoxy-d-glucose (FDG), proliferation with 18F-fluoro-thymidine (FLT), and hypoxia with 18fluoro-misonidazole (F-miso) before and during radiotherapy in patients with non-small-cell lung cancer (NSCLC): a pilot study. Radiother Oncol jan. 2011;98(1):109–16.CrossRef Vera P, Bohn P, Edet-Sanson A, Salles A, Hapdey S, Gardin I, et al. Simultaneous positron emission tomography (PET) assessment of metabolism with 18F-fluoro-2-deoxy-d-glucose (FDG), proliferation with 18F-fluoro-thymidine (FLT), and hypoxia with 18fluoro-misonidazole (F-miso) before and during radiotherapy in patients with non-small-cell lung cancer (NSCLC): a pilot study. Radiother Oncol jan. 2011;98(1):109–16.CrossRef
33.
Zurück zum Zitat Zar J. Biostatiscal analysis. 2nd ed. La Jolla: Prentice-Hall; 1984. Zar J. Biostatiscal analysis. 2nd ed. La Jolla: Prentice-Hall; 1984.
34.
Zurück zum Zitat Aupérin A, Le Péchoux C, Rolland E, Curran WJ, Furuse K, Fournel P, et al. Meta-analysis of concomitant versus sequential radiochemotherapy in locally advanced non-small-cell lung cancer. J Clin Oncol Off J Am Soc Clin Oncol. 2010;28(13):2181–90.CrossRef Aupérin A, Le Péchoux C, Rolland E, Curran WJ, Furuse K, Fournel P, et al. Meta-analysis of concomitant versus sequential radiochemotherapy in locally advanced non-small-cell lung cancer. J Clin Oncol Off J Am Soc Clin Oncol. 2010;28(13):2181–90.CrossRef
35.
Zurück zum Zitat Curran WJ, Paulus R, Langer CJ, Komaki R, Lee JS, Hauser S, et al. Sequential vs. concurrent chemoradiation for stage III non-small cell lung cancer: randomized phase III trial RTOG 9410. J Natl Cancer Inst. 2011;103(19):1452–60.CrossRef Curran WJ, Paulus R, Langer CJ, Komaki R, Lee JS, Hauser S, et al. Sequential vs. concurrent chemoradiation for stage III non-small cell lung cancer: randomized phase III trial RTOG 9410. J Natl Cancer Inst. 2011;103(19):1452–60.CrossRef
36.
Zurück zum Zitat van Elmpt W, De Ruysscher D, van der Salm A, Lakeman A, van der Stoep J, Emans D, et al. The PET-boost randomised phase II dose-escalation trial in non-small cell lung cancer. Radiother Oncol J Eur Soc Ther Radiol Oncol. 2012;104(1):67–71.CrossRef van Elmpt W, De Ruysscher D, van der Salm A, Lakeman A, van der Stoep J, Emans D, et al. The PET-boost randomised phase II dose-escalation trial in non-small cell lung cancer. Radiother Oncol J Eur Soc Ther Radiol Oncol. 2012;104(1):67–71.CrossRef
37.
Zurück zum Zitat Kelsey CR, Christensen JD, Chino JP, Adamson J, Ready NE, Perez BA. Adaptive planning using positron emission tomography for locally advanced lung cancer: a feasibility study. Pract Radiat Oncol. 2016;6(2):96–104.CrossRef Kelsey CR, Christensen JD, Chino JP, Adamson J, Ready NE, Perez BA. Adaptive planning using positron emission tomography for locally advanced lung cancer: a feasibility study. Pract Radiat Oncol. 2016;6(2):96–104.CrossRef
39.
Zurück zum Zitat Palie O, Michel P, Ménard J-F, Rousseau C, Rio E, Bridji B, et al. The predictive value of treatment response using FDG PET performed on day 21 of chemoradiotherapy in patients with oesophageal squamous cell carcinoma. A prospective, multicentre study (RTEP3). Eur J Nucl Med Mol Imaging. 2013;40(9):1345–55.CrossRef Palie O, Michel P, Ménard J-F, Rousseau C, Rio E, Bridji B, et al. The predictive value of treatment response using FDG PET performed on day 21 of chemoradiotherapy in patients with oesophageal squamous cell carcinoma. A prospective, multicentre study (RTEP3). Eur J Nucl Med Mol Imaging. 2013;40(9):1345–55.CrossRef
Metadaten
Titel
Delineation of lung cancer with FDG PET/CT during radiation therapy
verfasst von
J. Ganem
S. Thureau
I. Gardin
R. Modzelewski
S. Hapdey
P. Vera
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Radiation Oncology / Ausgabe 1/2018
Elektronische ISSN: 1748-717X
DOI
https://doi.org/10.1186/s13014-018-1163-2

Weitere Artikel der Ausgabe 1/2018

Radiation Oncology 1/2018 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.