Skip to main content
Erschienen in: Journal of Artificial Organs 3/2018

11.04.2018 | Original Article

Design of in situ porcine closed-circuit system for assessing blood-contacting biomaterials

verfasst von: Maria Chiara Munisso, Atsushi Mahara, Tetsuji Yamaoka

Erschienen in: Journal of Artificial Organs | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

The overall pre-clinical process of determining the blood compatibility of any medical device involves several stages. Although the primary purpose is to protect the patients, laboratory testing has been over-utilized for many years with a huge number of unnecessary animal tests being done routinely. Recently, the elimination of needless testing has become important in controlling the cost of healthcare and in addressing many issues related to the ethics of animal research. With this in mind, we designed a new in situ porcine closed-circuit system to study the complex interplay between platelets, coagulation proteins, and other cellular elements in pigs. We proved that this system can be implemented in blood compatibility testing and minimize the number of animals used in the experiments.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Voorhees AB Jr, Jaretzki A 3rd, Blakemore AH. The use of tubes constructed from vinyon “n” cloth in bridging arterial defects. Ann Surg. 1952;135:332–6.CrossRefPubMedPubMedCentral Voorhees AB Jr, Jaretzki A 3rd, Blakemore AH. The use of tubes constructed from vinyon “n” cloth in bridging arterial defects. Ann Surg. 1952;135:332–6.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Chlupác J, Filová E, Bačáková L. Blood vessel replacement: 50 years of development and tissue engineering paradigms in vascular surgery. Physiol Res. 2009;58:119–39. Chlupác J, Filová E, Bačáková L. Blood vessel replacement: 50 years of development and tissue engineering paradigms in vascular surgery. Physiol Res. 2009;58:119–39.
3.
Zurück zum Zitat Zilla P, Bezuidenhout D, Human P. Prosthetic vascular grafts: wrong models, wrong questions and no healing. Biomaterials. 2007;28:5009–27.CrossRefPubMed Zilla P, Bezuidenhout D, Human P. Prosthetic vascular grafts: wrong models, wrong questions and no healing. Biomaterials. 2007;28:5009–27.CrossRefPubMed
4.
Zurück zum Zitat Kakisis JD, Liapis CD, Breuer C, Sumpio BE. Artificial blood vessel: the Holy Grail of peripheral vascular surgery. J Vasc Surg. 2005;41:349–54.CrossRefPubMed Kakisis JD, Liapis CD, Breuer C, Sumpio BE. Artificial blood vessel: the Holy Grail of peripheral vascular surgery. J Vasc Surg. 2005;41:349–54.CrossRefPubMed
5.
Zurück zum Zitat Pashneh-Tala S, MacNeil S, Claeyssens F. The tissue-engineered vascular graft—past, present, and future. Tissue Eng Part B Rev. 2016;22(1):68–100.CrossRef Pashneh-Tala S, MacNeil S, Claeyssens F. The tissue-engineered vascular graft—past, present, and future. Tissue Eng Part B Rev. 2016;22(1):68–100.CrossRef
6.
Zurück zum Zitat Anderson DEJ, Glynn JJ, Song HK, Hinds MT. Engineering an endothelialized vascular graft: a rational approach to study design in a non-human primate model. PLoS One. 2014;9:1–23. Anderson DEJ, Glynn JJ, Song HK, Hinds MT. Engineering an endothelialized vascular graft: a rational approach to study design in a non-human primate model. PLoS One. 2014;9:1–23.
7.
Zurück zum Zitat Byrom MJ, Bannon PG, White GH, Ng MKC. Animal models for the assessment of novel vascular conduits. J Vasc Surg. 2010;52:176–95.CrossRefPubMed Byrom MJ, Bannon PG, White GH, Ng MKC. Animal models for the assessment of novel vascular conduits. J Vasc Surg. 2010;52:176–95.CrossRefPubMed
8.
9.
Zurück zum Zitat Ratner BD, Hoffman AS, Schoen FJ, Lemons JE (eds). PART III: practical aspects of biomaterials implants & devices—special concerns. In: Biomaterials science: an introduction to materials in medicine. 2nd ed. Elsevier Academic Press; 2004. Ratner BD, Hoffman AS, Schoen FJ, Lemons JE (eds). PART III: practical aspects of biomaterials implants & devices—special concerns. In: Biomaterials science: an introduction to materials in medicine. 2nd ed. Elsevier Academic Press; 2004.
10.
Zurück zum Zitat Greek R. A discussion of the role of complex evolved systems in the development of invasive cardiovascular interventions as illustrated by the Blalock-taussig shunt and intra-arterial stents. Biol Syst. 2014;3:1–27.CrossRef Greek R. A discussion of the role of complex evolved systems in the development of invasive cardiovascular interventions as illustrated by the Blalock-taussig shunt and intra-arterial stents. Biol Syst. 2014;3:1–27.CrossRef
11.
Zurück zum Zitat Jung F, Braune S, Lendlein A. Haemocompatibility testing of biomaterials using human platelets. Clin Hemorheol Microcirc. 2013;53:97–115.PubMed Jung F, Braune S, Lendlein A. Haemocompatibility testing of biomaterials using human platelets. Clin Hemorheol Microcirc. 2013;53:97–115.PubMed
12.
Zurück zum Zitat Noishiki Y. in vivo evaluation method of a new antithrombogenicity using the peripheral vein. J Bioact Compat Polym. 1986;1:147–61.CrossRef Noishiki Y. in vivo evaluation method of a new antithrombogenicity using the peripheral vein. J Bioact Compat Polym. 1986;1:147–61.CrossRef
13.
Zurück zum Zitat Silver JH, Hergenrother RW, Lin J-C, Lim F, Lin H-B, Okada T, et al. Surface and blood-contacting properties of alkylsiloxane monolayers supported on silicone rubber. J Biomed Mater Res. 1995;29:535–48.CrossRefPubMed Silver JH, Hergenrother RW, Lin J-C, Lim F, Lin H-B, Okada T, et al. Surface and blood-contacting properties of alkylsiloxane monolayers supported on silicone rubber. J Biomed Mater Res. 1995;29:535–48.CrossRefPubMed
14.
Zurück zum Zitat Badimon L, Vilahur G, Padro T. Atherosclerosis and thrombosis: insights from large animal models. J Biomed Biotechnol. 2011;2011:1–13. Badimon L, Vilahur G, Padro T. Atherosclerosis and thrombosis: insights from large animal models. J Biomed Biotechnol. 2011;2011:1–13.
15.
Zurück zum Zitat Munisso MC, Yamaoka T. Novel peptides for small-caliber graft functionalization selected by a phage display of endothelial-positive/platelet-negative combined selection. J Mater Chem B. 2017;5:9354–64.CrossRef Munisso MC, Yamaoka T. Novel peptides for small-caliber graft functionalization selected by a phage display of endothelial-positive/platelet-negative combined selection. J Mater Chem B. 2017;5:9354–64.CrossRef
16.
Zurück zum Zitat Leitão AF, Gupta S, Pedro J, Reviakine I, Gama M. Hemocompatibility study of a bacterial cellulose/polyvinyl alcohol nanocomposite. Colloids Surf B Biointerfaces. 2013;111:493–502.CrossRefPubMed Leitão AF, Gupta S, Pedro J, Reviakine I, Gama M. Hemocompatibility study of a bacterial cellulose/polyvinyl alcohol nanocomposite. Colloids Surf B Biointerfaces. 2013;111:493–502.CrossRefPubMed
17.
Zurück zum Zitat Motlagh D, Yang J, Lui KY, Webb AR, Ameer GA. Hemocompatibility evaluation of poly (glycerol-sebacate) in vitro for vascular tissue engineering. Biomaterials. 2006;27:4315–24.CrossRefPubMed Motlagh D, Yang J, Lui KY, Webb AR, Ameer GA. Hemocompatibility evaluation of poly (glycerol-sebacate) in vitro for vascular tissue engineering. Biomaterials. 2006;27:4315–24.CrossRefPubMed
18.
Zurück zum Zitat Noe DA, Weedn V, Bell WR. Direct spectrophotometry of serum hemoglobin: an Allen correction compared with a three-wavelength polychromatic analysis. Clin Chem. 1984;30:627–30.PubMed Noe DA, Weedn V, Bell WR. Direct spectrophotometry of serum hemoglobin: an Allen correction compared with a three-wavelength polychromatic analysis. Clin Chem. 1984;30:627–30.PubMed
19.
Zurück zum Zitat Cookson P, Sutherland J, Cardigan R. A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates. Vox Sang. 2004;87:264–71.CrossRefPubMed Cookson P, Sutherland J, Cardigan R. A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates. Vox Sang. 2004;87:264–71.CrossRefPubMed
20.
Zurück zum Zitat Han V, Serrano K, Devine DV. A comparative study of common techniques used to measure haemolysis in stored red cell concentrates. Vox Sang. 2010;98:116–23.CrossRefPubMed Han V, Serrano K, Devine DV. A comparative study of common techniques used to measure haemolysis in stored red cell concentrates. Vox Sang. 2010;98:116–23.CrossRefPubMed
21.
Zurück zum Zitat Mahara A, Somekawa S, Kobayashi N, Hirano Y, Kimura Y, Fujisato T, et al. Tissue-engineered acellular small diameter long-bypass grafts with neointima-inducing activity. Biomaterials. 2015;58:54–62.CrossRefPubMed Mahara A, Somekawa S, Kobayashi N, Hirano Y, Kimura Y, Fujisato T, et al. Tissue-engineered acellular small diameter long-bypass grafts with neointima-inducing activity. Biomaterials. 2015;58:54–62.CrossRefPubMed
22.
Zurück zum Zitat Hubbell J, Massia S, Desai N, Drumheller P. Endothelial cell-selective materials for tissue engineering in the vascular graft via a new receptor. Biotechnology. 1991;9:568–72.PubMed Hubbell J, Massia S, Desai N, Drumheller P. Endothelial cell-selective materials for tissue engineering in the vascular graft via a new receptor. Biotechnology. 1991;9:568–72.PubMed
23.
Zurück zum Zitat Massia S, Hubbell J. Vascular endothelial-cell adhesion and spreading promoted by the peptide Redv of the iiics region of plasma fibronectin is mediated by integrin alpha-4-beta-1. J Biol Chem. 1992;267:14019–26.PubMed Massia S, Hubbell J. Vascular endothelial-cell adhesion and spreading promoted by the peptide Redv of the iiics region of plasma fibronectin is mediated by integrin alpha-4-beta-1. J Biol Chem. 1992;267:14019–26.PubMed
24.
Zurück zum Zitat Merhi Y, King M, Guidoin R. Acute thrombogenicity of intact and injured natural blood conduits versus synthetic conduits: neutrophil, platelet, and fibrin(ogen) adsorption under various shear-rate conditions. J Biomed Mater Res. 1997;34:477–85.CrossRefPubMed Merhi Y, King M, Guidoin R. Acute thrombogenicity of intact and injured natural blood conduits versus synthetic conduits: neutrophil, platelet, and fibrin(ogen) adsorption under various shear-rate conditions. J Biomed Mater Res. 1997;34:477–85.CrossRefPubMed
25.
Zurück zum Zitat Tatterton M, Wilshaw S, Ingham E, Homer-Vanniasinkam S. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis. Vasc Endovasc Surg. 2012;46:212–22.CrossRef Tatterton M, Wilshaw S, Ingham E, Homer-Vanniasinkam S. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis. Vasc Endovasc Surg. 2012;46:212–22.CrossRef
26.
Zurück zum Zitat Lee JH, Khang G, Lee JW, Lee HB. Platelet adhesion onto chargeable functional group gradient surfaces. J Biomed Mater Res. 1998;41:304–11.CrossRefPubMed Lee JH, Khang G, Lee JW, Lee HB. Platelet adhesion onto chargeable functional group gradient surfaces. J Biomed Mater Res. 1998;41:304–11.CrossRefPubMed
27.
Zurück zum Zitat Goodman SL. Sheep, pig, and human platelet–material interactions with model cardiovascular biomaterials. J Biomed Mater Res. 1999;45:240–50.CrossRefPubMed Goodman SL. Sheep, pig, and human platelet–material interactions with model cardiovascular biomaterials. J Biomed Mater Res. 1999;45:240–50.CrossRefPubMed
Metadaten
Titel
Design of in situ porcine closed-circuit system for assessing blood-contacting biomaterials
verfasst von
Maria Chiara Munisso
Atsushi Mahara
Tetsuji Yamaoka
Publikationsdatum
11.04.2018
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 3/2018
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-018-1042-5

Weitere Artikel der Ausgabe 3/2018

Journal of Artificial Organs 3/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.