Skip to main content
Erschienen in:

10.01.2022 | Original Paper

Detection and Grading of Hypertensive Retinopathy Using Vessels Tortuosity and Arteriovenous Ratio

verfasst von: Sufian A. Badawi, Muhammad Moazam Fraz, Muhammad Shehzad, Imran Mahmood, Sajid Javed, Emad Mosalam, Ajay Kamath Nileshwar

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 2/2022

Einloggen, um Zugang zu erhalten

Abstract

Hypertensive retinopathy (HR) refers to changes in the morphological diameter of the retinal vessels due to persistent high blood pressure. Early detection of such changes helps in preventing blindness or even death due to stroke. These changes can be quantified by computing the arteriovenous ratio and the tortuosity severity in the retinal vasculature. This paper presents a decision support system for detecting and grading HR using morphometric analysis of retinal vasculature, particularly measuring the arteriovenous ratio (AVR) and retinal vessel tortuosity. In the first step, the retinal blood vessels are segmented and classified as arteries and veins. Then, the width of arteries and veins is measured within the region of interest around the optic disk. Next, a new iterative method is proposed to compute the AVR from the caliber measurements of arteries and veins using Parr–Hubbard and Knudtson methods. Moreover, the retinal vessel tortuosity severity index is computed for each image using 14 tortuosity severity metrics. In the end, a hybrid decision support system is proposed for the detection and grading of HR using AVR and tortuosity severity index. Furthermore, we present a new publicly available retinal vessel morphometry (RVM) dataset to evaluate the proposed methodology. The RVM dataset contains 504 retinal images with pixel-level annotations for vessel segmentation, artery/vein classification, and optic disk localization. The image-level labels for vessel tortuosity index and HR grade are also available. The proposed methods of iterative AVR measurement, tortuosity index, and HR grading are evaluated using the new RVM dataset. The results indicate that the proposed method gives superior performance than existing methods. The presented methodology is a novel advancement in automated detection and grading of HR, which can potentially be used as a clinical decision support system.
Literatur
1.
Zurück zum Zitat Abbasi, U.G., Akram, M.U.: Classification of blood vessels as arteries and veins for diagnosis of hypertensive retinopathy. In: 2014 10th International Computer Engineering Conference (ICENCO), pp. 5–9. IEEE (2014) Abbasi, U.G., Akram, M.U.: Classification of blood vessels as arteries and veins for diagnosis of hypertensive retinopathy. In: 2014 10th International Computer Engineering Conference (ICENCO), pp. 5–9. IEEE (2014)
2.
Zurück zum Zitat Abdullah, M., Fraz, M.M.: Application of grow cut algorithm for localization and extraction of optic disc in retinal images. In: 2015 12th International Conference on High-capacity Optical Networks and Enabling/Emerging Technologies (HONET), pp. 1–5. IEEE (2015) Abdullah, M., Fraz, M.M.: Application of grow cut algorithm for localization and extraction of optic disc in retinal images. In: 2015 12th International Conference on High-capacity Optical Networks and Enabling/Emerging Technologies (HONET), pp. 1–5. IEEE (2015)
3.
Zurück zum Zitat Abdullah, M., Fraz, M.M., Barman, S.A.: Localization and segmentation of optic disc in retinal images using circular hough transform and grow-cut algorithm. PeerJ 4, e2003 (2016) Abdullah, M., Fraz, M.M., Barman, S.A.: Localization and segmentation of optic disc in retinal images using circular hough transform and grow-cut algorithm. PeerJ 4, e2003 (2016)
4.
Zurück zum Zitat Akbar, S., Akram, M.U., Sharif, M., Tariq, A., ullah Yasin, U.: Arteriovenous ratio and papilledema based hybrid decision support system for detection and grading of hypertensive retinopathy. Computer methods and programs in biomedicine 154, 123–141 (2018) Akbar, S., Akram, M.U., Sharif, M., Tariq, A., ullah Yasin, U.: Arteriovenous ratio and papilledema based hybrid decision support system for detection and grading of hypertensive retinopathy. Computer methods and programs in biomedicine 154, 123–141 (2018)
5.
Zurück zum Zitat Akbar, S., Hassan, T., Akram, M.U., Yasin, U.U., Basit, I.: Avrdb: annotated dataset for vessel segmentation and calculation of arteriovenous ratio (2017) Akbar, S., Hassan, T., Akram, M.U., Yasin, U.U., Basit, I.: Avrdb: annotated dataset for vessel segmentation and calculation of arteriovenous ratio (2017)
6.
Zurück zum Zitat AlBadawi, S., Fraz, M.: Arterioles and venules classification in retinal images using fully convolutional deep neural network. In: International Conference Image Analysis and Recognition, pp. 659–668. Springer (2018) AlBadawi, S., Fraz, M.: Arterioles and venules classification in retinal images using fully convolutional deep neural network. In: International Conference Image Analysis and Recognition, pp. 659–668. Springer (2018)
7.
Zurück zum Zitat Badawi, S.A., Fraz, M.M.: Optimizing the trainable b-cosfire filter for retinal blood vessel segmentation. PeerJ 6, e5855 (2018) Badawi, S.A., Fraz, M.M.: Optimizing the trainable b-cosfire filter for retinal blood vessel segmentation. PeerJ 6, e5855 (2018)
8.
Zurück zum Zitat Badawi, S.A., Fraz, M.M.: Multiloss function based deep convolutional neural network for segmentation of retinal vasculature into arterioles and venules. BioMed research international 2019 (2019) Badawi, S.A., Fraz, M.M.: Multiloss function based deep convolutional neural network for segmentation of retinal vasculature into arterioles and venules. BioMed research international 2019 (2019)
9.
Zurück zum Zitat Basit, A., Fraz, M.M.: Optic disc detection and boundary extraction in retinal images. Applied optics 54(11), 3440–3447 (2015) Basit, A., Fraz, M.M.: Optic disc detection and boundary extraction in retinal images. Applied optics 54(11), 3440–3447 (2015)
10.
Zurück zum Zitat Bhargava, M., Wong, T.: Current concepts in hypertensive retinopathy. Retinal Physician 10, 43–54 (2013) Bhargava, M., Wong, T.: Current concepts in hypertensive retinopathy. Retinal Physician 10, 43–54 (2013)
11.
Zurück zum Zitat Bowling, B.: Kanski's clinical ophthalmology: a systematic approach. Saunders Ltd (2015) Bowling, B.: Kanski's clinical ophthalmology: a systematic approach. Saunders Ltd (2015)
12.
Zurück zum Zitat Dash, J., Bhoi, N.: An unsupervised approach for extraction of blood vessels from fundus images. Journal of digital imaging 31(6), 857–868 (2018) Dash, J., Bhoi, N.: An unsupervised approach for extraction of blood vessels from fundus images. Journal of digital imaging 31(6), 857–868 (2018)
13.
Zurück zum Zitat Decencière, E., Zhang, X., Cazuguel, G., Lay, B., Cochener, B., Trone, C., Gain, P., Ordonez, R., Massin, P., Erginay, A., et al.: Feedback on a publicly distributed image database: the messidor database. Image Analysis & Stereology 33(3), 231–234 (2014) Decencière, E., Zhang, X., Cazuguel, G., Lay, B., Cochener, B., Trone, C., Gain, P., Ordonez, R., Massin, P., Erginay, A., et al.: Feedback on a publicly distributed image database: the messidor database. Image Analysis & Stereology 33(3), 231–234 (2014)
14.
Zurück zum Zitat Faheem, M.R., Din, M.: Diagnosing hypertensive retinopathy through retinal images. Biomedical Research and Therapy 2(10), 385–388 (2015) Faheem, M.R., Din, M.: Diagnosing hypertensive retinopathy through retinal images. Biomedical Research and Therapy 2(10), 385–388 (2015)
15.
Zurück zum Zitat Fatima, K.N., Hassan, T., Akram, M.U., Akhtar, M., Butt, W.H.: Fully automated diagnosis of papilledema through robust extraction of vascular patterns and ocular pathology from fundus photographs. Biomedical optics express 8(2), 1005–1024 (2017) Fatima, K.N., Hassan, T., Akram, M.U., Akhtar, M., Butt, W.H.: Fully automated diagnosis of papilledema through robust extraction of vascular patterns and ocular pathology from fundus photographs. Biomedical optics express 8(2), 1005–1024 (2017)
16.
Zurück zum Zitat Foracchia, M., Grisan, E., Ruggeri, A.: Luminosity and contrast normalization in retinal images. Medical Image Analysis 9(3), 179–190 (2005) Foracchia, M., Grisan, E., Ruggeri, A.: Luminosity and contrast normalization in retinal images. Medical Image Analysis 9(3), 179–190 (2005)
17.
Zurück zum Zitat Fraz, M., Badar, M., Malik, A., Barman, S.: Computational methods for exudates detection and macular edema estimation in retinal images: a survey. Archives of Computational Methods in Engineering pp. 1–28 (2018) Fraz, M., Badar, M., Malik, A., Barman, S.: Computational methods for exudates detection and macular edema estimation in retinal images: a survey. Archives of Computational Methods in Engineering pp. 1–28 (2018)
18.
Zurück zum Zitat Fraz, M., Remagnino, P., Hoppe, A., Rudnicka, A.R., Owen, C.G., Whincup, P., Barman, S.: Quantification of blood vessel calibre in retinal images of multi-ethnic school children using a model based approach. Computerized Medical Imaging and Graphics 37(1), 48–60 (2013) Fraz, M., Remagnino, P., Hoppe, A., Rudnicka, A.R., Owen, C.G., Whincup, P., Barman, S.: Quantification of blood vessel calibre in retinal images of multi-ethnic school children using a model based approach. Computerized Medical Imaging and Graphics 37(1), 48–60 (2013)
19.
Zurück zum Zitat Fraz, M., Rudnicka, A.R., Owen, C.G., Strachan, D., Barman, S.A.: Automated arteriole and venule recognition in retinal images using ensemble classification. In: 2014 International Conference on Computer Vision Theory and Applications (VISAPP), vol. 3, pp. 194–202. IEEE (2014) Fraz, M., Rudnicka, A.R., Owen, C.G., Strachan, D., Barman, S.A.: Automated arteriole and venule recognition in retinal images using ensemble classification. In: 2014 International Conference on Computer Vision Theory and Applications (VISAPP), vol. 3, pp. 194–202. IEEE (2014)
20.
Zurück zum Zitat Fraz, M.M., Barman, S.A.: Computer vision algorithms applied to retinal vessel segmentation and quantification of vessel caliber. Image Analysis and Modeling in Ophthalmology 49 (2014) Fraz, M.M., Barman, S.A.: Computer vision algorithms applied to retinal vessel segmentation and quantification of vessel caliber. Image Analysis and Modeling in Ophthalmology 49 (2014)
21.
Zurück zum Zitat Fraz, M.M., Jahangir, W., Zahid, S., Hamayun, M.M., Barman, S.A.: Multiscale segmentation of exudates in retinal images using contextual cues and ensemble classification. Biomedical Signal Processing and Control 35, 50–62 (2017) Fraz, M.M., Jahangir, W., Zahid, S., Hamayun, M.M., Barman, S.A.: Multiscale segmentation of exudates in retinal images using contextual cues and ensemble classification. Biomedical Signal Processing and Control 35, 50–62 (2017)
22.
Zurück zum Zitat Fraz, M.M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Owen, C.G., Rudnicka, A.R., Barman, S.: Retinal vessel extraction using first-order derivative of gaussian and morphological processing. In: International Symposium on Visual Computing, pp. 410–420. Springer (2011) Fraz, M.M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Owen, C.G., Rudnicka, A.R., Barman, S.: Retinal vessel extraction using first-order derivative of gaussian and morphological processing. In: International Symposium on Visual Computing, pp. 410–420. Springer (2011)
23.
Zurück zum Zitat Fraz, M.M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A.R., Owen, C.G., Barman, S.A.: Blood vessel segmentation methodologies in retinal images{a survey. Computer methods and programs in biomedicine 108(1), 407–433 (2012) Fraz, M.M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A.R., Owen, C.G., Barman, S.A.: Blood vessel segmentation methodologies in retinal images{a survey. Computer methods and programs in biomedicine 108(1), 407–433 (2012)
24.
Zurück zum Zitat Fraz, M.M., Rudnicka, A.R., Owen, C.G., Barman, S.A.: Delineation of blood vessels in pediatric retinal images using decision trees-based ensemble classification. International journal of computer assisted radiology and surgery 9(5), 795–811 (2014) Fraz, M.M., Rudnicka, A.R., Owen, C.G., Barman, S.A.: Delineation of blood vessels in pediatric retinal images using decision trees-based ensemble classification. International journal of computer assisted radiology and surgery 9(5), 795–811 (2014)
25.
Zurück zum Zitat Fraz, M.M., Welikala, R., Rudnicka, A.R., Owen, C.G., Strachan, D., Barman, S.A.: Quartz: Quantitative analysis of retinal vessel topology and size–an automated system for quantification of retinal vessels morphology. Expert Systems with Applications 42(20), 7221–7234 (2015) Fraz, M.M., Welikala, R., Rudnicka, A.R., Owen, C.G., Strachan, D., Barman, S.A.: Quartz: Quantitative analysis of retinal vessel topology and size–an automated system for quantification of retinal vessels morphology. Expert Systems with Applications 42(20), 7221–7234 (2015)
26.
Zurück zum Zitat Heitmar, R., Kalitzeos, A.A., Panesar, V.: Comparison of two formulas used to calculate summarized retinal vessel calibers. Optometry and Vision Science 92(11), 1085–1091 (2015) Heitmar, R., Kalitzeos, A.A., Panesar, V.: Comparison of two formulas used to calculate summarized retinal vessel calibers. Optometry and Vision Science 92(11), 1085–1091 (2015)
27.
Zurück zum Zitat Hu, Q., Abràmoff, M.D., Garvin, M.K.: Automated separation of binary overlapping trees in low-contrast color retinal images. In: International conference on medical image computing and computer-assisted intervention, pp. 436–443. Springer (2013) Hu, Q., Abràmoff, M.D., Garvin, M.K.: Automated separation of binary overlapping trees in low-contrast color retinal images. In: International conference on medical image computing and computer-assisted intervention, pp. 436–443. Springer (2013)
28.
Zurück zum Zitat Hubbard, L.D., Brothers, R.J., King, W.N., Clegg, L.X., Klein, R., Cooper, L.S., Sharrett, A.R., Davis, M.D., Cai, J., in Communities Study Group, A.R., et al.: Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the atherosclerosis risk in communities study. Ophthalmology 106(12), 2269–2280 (1999) Hubbard, L.D., Brothers, R.J., King, W.N., Clegg, L.X., Klein, R., Cooper, L.S., Sharrett, A.R., Davis, M.D., Cai, J., in Communities Study Group, A.R., et al.: Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the atherosclerosis risk in communities study. Ophthalmology 106(12), 2269–2280 (1999)
29.
Zurück zum Zitat Irshad, S., Akram, M.U.: Classification of retinal vessels into arteries and veins for detection of hypertensive retinopathy. In: 2014 Cairo International Biomedical Engineering Conference (CIBEC), pp. 133–136. IEEE (2014) Irshad, S., Akram, M.U.: Classification of retinal vessels into arteries and veins for detection of hypertensive retinopathy. In: 2014 Cairo International Biomedical Engineering Conference (CIBEC), pp. 133–136. IEEE (2014)
30.
Zurück zum Zitat Kalitzeos, A.A., Lip, G.Y., Heitmar, R.: Retinal vessel tortuosity measures and their applications. Experimental eye research 106, 40–46 (2013) Kalitzeos, A.A., Lip, G.Y., Heitmar, R.: Retinal vessel tortuosity measures and their applications. Experimental eye research 106, 40–46 (2013)
31.
Zurück zum Zitat Keith, N.: Some different types of essential hypertension: their course and prognosis. Am J Med Sci 268, 336–345 (1974) Keith, N.: Some different types of essential hypertension: their course and prognosis. Am J Med Sci 268, 336–345 (1974)
32.
Zurück zum Zitat Khitran, S., Akram, M.U., Usman, A., Yasin, U.: Automated system for the detection of hypertensive retinopathy. In: 2014 4th International Conference on Image Processing Theory, Tools and Applications (IPTA), pp. 1–6. IEEE (2014) Khitran, S., Akram, M.U., Usman, A., Yasin, U.: Automated system for the detection of hypertensive retinopathy. In: 2014 4th International Conference on Image Processing Theory, Tools and Applications (IPTA), pp. 1–6. IEEE (2014)
33.
Zurück zum Zitat Knudtson, M.D., Lee, K.E., Hubbard, L.D., Wong, T.Y., Klein, R., Klein, B.E.: Revised formulas for summarizing retinal vessel diameters. Current eye research 27(3), 143–149 (2003) Knudtson, M.D., Lee, K.E., Hubbard, L.D., Wong, T.Y., Klein, R., Klein, B.E.: Revised formulas for summarizing retinal vessel diameters. Current eye research 27(3), 143–149 (2003)
34.
Zurück zum Zitat Li, X., Wee, W.G.: Retinal vessel detection and measurement for computer-aided medical diagnosis. Journal of digital imaging 27(1), 120–132 (2014) Li, X., Wee, W.G.: Retinal vessel detection and measurement for computer-aided medical diagnosis. Journal of digital imaging 27(1), 120–132 (2014)
35.
Zurück zum Zitat Lotmar, W., Freiburghaus, A., Bracher, D.: Measurement of vessel tortuosity on fundus photographs. Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie 211(1), 49–57 (1979) Lotmar, W., Freiburghaus, A., Bracher, D.: Measurement of vessel tortuosity on fundus photographs. Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie 211(1), 49–57 (1979)
36.
Zurück zum Zitat Maddah, M., Soltanian-Zadeh, H., Afzali-Kusha, A., Shahrokni, A., Zhang, Z.G.: Three-dimensional analysis of complex branching vessels in confocal microscopy images. Computerized Medical Imaging and Graphics 29(6), 487–498 (2005) Maddah, M., Soltanian-Zadeh, H., Afzali-Kusha, A., Shahrokni, A., Zhang, Z.G.: Three-dimensional analysis of complex branching vessels in confocal microscopy images. Computerized Medical Imaging and Graphics 29(6), 487–498 (2005)
37.
Zurück zum Zitat Manikis, G.C., Sakkalis, V., Zabulis, X., Karamaounas, P., Triantafyllou, A., Douma, S., Zamboulis, C., Marias, K.: An image analysis framework for the early assessment of hypertensive retinopathy signs. In: 2011 E-Health and Bioengineering Conference (EHB), pp. 1–6. IEEE (2011) Manikis, G.C., Sakkalis, V., Zabulis, X., Karamaounas, P., Triantafyllou, A., Douma, S., Zamboulis, C., Marias, K.: An image analysis framework for the early assessment of hypertensive retinopathy signs. In: 2011 E-Health and Bioengineering Conference (EHB), pp. 1–6. IEEE (2011)
38.
Zurück zum Zitat Muramatsu, C., Hatanaka, Y., Iwase, T., Hara, T., Fujita, H.: Automated detection and classification of major retinal vessels for determination of diameter ratio of arteries and veins. In: Medical Imaging 2010: Computer-Aided Diagnosis, vol. 7624, p. 76240J. International Society for Optics and Photonics (2010) Muramatsu, C., Hatanaka, Y., Iwase, T., Hara, T., Fujita, H.: Automated detection and classification of major retinal vessels for determination of diameter ratio of arteries and veins. In: Medical Imaging 2010: Computer-Aided Diagnosis, vol. 7624, p. 76240J. International Society for Optics and Photonics (2010)
39.
Zurück zum Zitat Nguyen, U.T., Bhuiyan, A., Park, L.A., Kawasaki, R., Wong, T.Y., Wang, J.J., Mitchell, P., Ramamohanarao, K.: An automated method for retinal arteriovenous nicking quantification from color fundus images. IEEE Transactions on Biomedical Engineering 60(11), 3194–3203 (2013) Nguyen, U.T., Bhuiyan, A., Park, L.A., Kawasaki, R., Wong, T.Y., Wang, J.J., Mitchell, P., Ramamohanarao, K.: An automated method for retinal arteriovenous nicking quantification from color fundus images. IEEE Transactions on Biomedical Engineering 60(11), 3194–3203 (2013)
40.
Zurück zum Zitat Noronha, K., Navya, K., Nayak, K.P.: Support system for the automated detection of hypertensive retinopathy using fundus images. In: International Conference on Electronic Design and Signal Processing (ICEDSP), pp. 7–11 (2012) Noronha, K., Navya, K., Nayak, K.P.: Support system for the automated detection of hypertensive retinopathy using fundus images. In: International Conference on Electronic Design and Signal Processing (ICEDSP), pp. 7–11 (2012)
41.
Zurück zum Zitat van Overveld, I.M.: Contrast, noise, and blur affect performance and appreciation of digital radiographs. Journal of digital imaging 8(4), 168 (1995) van Overveld, I.M.: Contrast, noise, and blur affect performance and appreciation of digital radiographs. Journal of digital imaging 8(4), 168 (1995)
42.
Zurück zum Zitat Perez-Rovira, A., MacGillivray, T., Trucco, E., Chin, K., Zutis, K., Lupascu, C., Tegolo, D., Giachetti, A., Wilson, P.J., Doney, A., et al.: Vampire: vessel assessment and measurement platform for images of the retina. In: 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 3391–3394. IEEE (2011) Perez-Rovira, A., MacGillivray, T., Trucco, E., Chin, K., Zutis, K., Lupascu, C., Tegolo, D., Giachetti, A., Wilson, P.J., Doney, A., et al.: Vampire: vessel assessment and measurement platform for images of the retina. In: 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 3391–3394. IEEE (2011)
43.
Zurück zum Zitat Rani, A., Mittal, D.: Measurement of arterio-venous ratio for detection of hypertensive retinopathy through digital color fundus images. Journal of Biomedical Engineering and Medical Imaging 2(5), 35 (2015) Rani, A., Mittal, D.: Measurement of arterio-venous ratio for detection of hypertensive retinopathy through digital color fundus images. Journal of Biomedical Engineering and Medical Imaging 2(5), 35 (2015)
44.
Zurück zum Zitat Rodrigues, L.C., Marengoni, M.: Segmentation of optic disc and blood vessels in retinal images using wavelets, mathematical morphology and hessian-based multi-scale filtering. Biomedical Signal Processing and Control 36, 39–49 (2017) Rodrigues, L.C., Marengoni, M.: Segmentation of optic disc and blood vessels in retinal images using wavelets, mathematical morphology and hessian-based multi-scale filtering. Biomedical Signal Processing and Control 36, 39–49 (2017)
45.
Zurück zum Zitat Roy, P.K., Nguyen, U.T., Bhuiyan, A., Ramamohanarao, K.: An effective automated system for grading severity of retinal arteriovenous nicking in colour retinal images. In: 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 6324–6327. IEEE (2014) Roy, P.K., Nguyen, U.T., Bhuiyan, A., Ramamohanarao, K.: An effective automated system for grading severity of retinal arteriovenous nicking in colour retinal images. In: 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 6324–6327. IEEE (2014)
46.
Zurück zum Zitat Sathananthavathi, V., Indumathi, G., et al.: Parallel architecture of fully convolved neural network for retinal vessel segmentation. Journal of digital imaging 33(1), 168–180 (2020) Sathananthavathi, V., Indumathi, G., et al.: Parallel architecture of fully convolved neural network for retinal vessel segmentation. Journal of digital imaging 33(1), 168–180 (2020)
47.
Zurück zum Zitat Son, J., Park, S.J., Jung, K.: Towards accurate segmentation of retinal and the optic disc in fundoscopic images with generative adversarial networks. Journal of digital imaging 32(3), 499–512 (2019) Son, J., Park, S.J., Jung, K.: Towards accurate segmentation of retinal and the optic disc in fundoscopic images with generative adversarial networks. Journal of digital imaging 32(3), 499–512 (2019)
48.
Zurück zum Zitat Stabingis, G., Bernatavičienė, J., Dzemyda, G., Paunksnis, A., Stabingienė, L., Treigys, P., Vaičaitienė, R.: Adaptive eye fundus vessel classification for automatic artery and vein diameter ratio evaluation. Informatica 29(4), 757–771 (2018) Stabingis, G., Bernatavičienė, J., Dzemyda, G., Paunksnis, A., Stabingienė, L., Treigys, P., Vaičaitienė, R.: Adaptive eye fundus vessel classification for automatic artery and vein diameter ratio evaluation. Informatica 29(4), 757–771 (2018)
49.
Zurück zum Zitat Sun, C., Wang, J.J., Mackey, D.A., Wong, T.Y.: Retinal vascular caliber: systemic, environmental, and genetic associations. Survey of ophthalmology 54(1), 74–95 (2009) Sun, C., Wang, J.J., Mackey, D.A., Wong, T.Y.: Retinal vascular caliber: systemic, environmental, and genetic associations. Survey of ophthalmology 54(1), 74–95 (2009)
50.
Zurück zum Zitat Suzuki, Y.: Direct measurement of retinal vessel diameter: comparison with microdensitometric methods based on fundus photographs. Survey of ophthalmology 39, S57–S65 (1995) Suzuki, Y.: Direct measurement of retinal vessel diameter: comparison with microdensitometric methods based on fundus photographs. Survey of ophthalmology 39, S57–S65 (1995)
51.
Zurück zum Zitat Ünver, H.M., Kökver, Y., Duman, E., Erdem, O.A.: Statistical edge detection and circular hough transform for optic disk localization. Applied Sciences 9(2), 350 (2019) Ünver, H.M., Kökver, Y., Duman, E., Erdem, O.A.: Statistical edge detection and circular hough transform for optic disk localization. Applied Sciences 9(2), 350 (2019)
52.
Zurück zum Zitat Wegmann-Burns, M., Gugger, M., Goldblum, D.: Hypertensive retinopathy. The Lancet 363(9407), 456 (2004) Wegmann-Burns, M., Gugger, M., Goldblum, D.: Hypertensive retinopathy. The Lancet 363(9407), 456 (2004)
53.
Zurück zum Zitat Welikala, R., Fraz, M., Williamson, T., Barman, S.: The automated detection of proliferative diabetic retinopathy using dual ensemble classification. International Journal of Diagnostic Imaging 2(2), 64–71 (2015) Welikala, R., Fraz, M., Williamson, T., Barman, S.: The automated detection of proliferative diabetic retinopathy using dual ensemble classification. International Journal of Diagnostic Imaging 2(2), 64–71 (2015)
54.
Zurück zum Zitat Wolz, J., Audebert, H., Laumeier, I., Ahmadi, M., Steinicke, M., Ferse, C., Michelson, G.: Telemedical assessment of optic nerve head and retina in patients after recent minor stroke or tia. International ophthalmology 37(1), 39–46 (2017) Wolz, J., Audebert, H., Laumeier, I., Ahmadi, M., Steinicke, M., Ferse, C., Michelson, G.: Telemedical assessment of optic nerve head and retina in patients after recent minor stroke or tia. International ophthalmology 37(1), 39–46 (2017)
55.
Zurück zum Zitat Xu, X., Ding, W., Abràmoff, M.D., Cao, R.: An improved arteriovenous classification method for the early diagnostics of various diseases in retinal image. Computer methods and programs in biomedicine 141, 3–9 (2017) Xu, X., Ding, W., Abràmoff, M.D., Cao, R.: An improved arteriovenous classification method for the early diagnostics of various diseases in retinal image. Computer methods and programs in biomedicine 141, 3–9 (2017)
56.
Zurück zum Zitat Yang, T., Wu, T., Li, L., Zhu, C.: Sud-gan: Deep convolution generative adversarial network combined with short connection and dense block for retinal vessel segmentation. Journal of Digital Imaging pp. 1–12 (2020) Yang, T., Wu, T., Li, L., Zhu, C.: Sud-gan: Deep convolution generative adversarial network combined with short connection and dense block for retinal vessel segmentation. Journal of Digital Imaging pp. 1–12 (2020)
57.
Zurück zum Zitat Zahoor, M.N., Fraz, M.M.: Fast optic disc segmentation in retina using polar transform. IEEE Access 5, 12293–12300 (2017) Zahoor, M.N., Fraz, M.M.: Fast optic disc segmentation in retina using polar transform. IEEE Access 5, 12293–12300 (2017)
Metadaten
Titel
Detection and Grading of Hypertensive Retinopathy Using Vessels Tortuosity and Arteriovenous Ratio
verfasst von
Sufian A. Badawi
Muhammad Moazam Fraz
Muhammad Shehzad
Imran Mahmood
Sajid Javed
Emad Mosalam
Ajay Kamath Nileshwar
Publikationsdatum
10.01.2022
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 2/2022
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-021-00545-z

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.