Skip to main content
main-content

28.11.2016 | Original Article | Ausgabe 4/2017

European Journal of Nuclear Medicine and Molecular Imaging 4/2017

Detection rate of PET/CT in patients with biochemical relapse of prostate cancer using [68Ga]PSMA I&T and comparison with published data of [68Ga]PSMA HBED-CC

Zeitschrift:
European Journal of Nuclear Medicine and Molecular Imaging > Ausgabe 4/2017
Autoren:
Christoph Berliner, Milena Tienken, Thorsten Frenzel, Yuske Kobayashi, Annabelle Helberg, Uve Kirchner, Susanne Klutmann, Dirk Beyersdorff, Lars Budäus, Hans-Jürgen Wester, Janos Mester, Peter Bannas
Wichtige Hinweise
Christoph Berliner and Milena Tienken contributed equally to this work.

Abstract

Purpose

To determine the detection rate of PET/CT in biochemical relapse of prostate cancer using [68Ga]PSMA I&T and to compare it with published detection rates of [68Ga]PSMA HBED-CC.

Methods

We performed a retrospective analysis in 83 consecutive patients with documented biochemical relapse after prostatectomy. All patients underwent whole body [68Ga]PSMA I&T PET/CT. PET/CT images were evaluated for presence of local recurrence, lymph node metastases, and distant metastases. Proportions of positive PET/CT results were calculated for six subgroups with increasing prostate specific antigen (PSA) levels (<0.5 ng/mL, 0.5 to <1.0 ng/mL, 1.0 to <2.0 ng/mL, 2.0 to <5.0 ng/mL, 5.0 to <10.0, ≥10.0 ng/mL). Detection rates of [68Ga]PSMA I&T were statistically compared with published detection rates of [68Ga]PSMA HBED-CC using exact Fisher’s test.

Results

Median PSA was 0.81 (range: 0.01 – 128) ng/mL. In 58/83 patients (70 %) at least one [68Ga]PSMA I&T positive lesion was detected. Local recurrent cancer was present in 18 patients (22 %), lymph node metastases in 29 patients (35 %), and distant metastases in 15 patients (18 %). The tumor detection rate was positively correlated with PSA levels, resulting in detection rates of 52 % (<0.5 ng/mL), 55 % (0.5 to <1.0 ng/mL), 70 % (1.0 to <2.0 ng/mL), 93 % (2.0 to <5.0 ng/mL), 100 % (5.0 to <10.0 ng/mL), and 100 % (≥10.0 ng/mL). There was no significant difference between the detection rate of [68Ga]PSMA I&T and published detection rates of [68Ga]PSMA HBED-CC (all p>0.05).

Conclusions

[68Ga]PSMA I&T PET/CT has high detection rates of recurrent prostate cancer that are comparable to [68Ga]PSMA HBED-CC.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 4/2017

European Journal of Nuclear Medicine and Molecular Imaging 4/2017Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.