Skip to main content
Erschienen in: Journal of Digital Imaging 2/2017

26.12.2016

Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), −10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes −0.1 ml; CI −31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.
Literatur
1.
Zurück zum Zitat Abraham G, et al.: Chronic kidney disease hotspots in developing countries in South Asia. Clinical kidney journal 9:135–141, 2016CrossRefPubMed Abraham G, et al.: Chronic kidney disease hotspots in developing countries in South Asia. Clinical kidney journal 9:135–141, 2016CrossRefPubMed
2.
Zurück zum Zitat Grams ME, et al.: Trends in the prevalence of reduced GFR in the United States: a comparison of creatinine- and cystatin C-based estimates. American journal of kidney diseases : the official journal of the National Kidney Foundation 62:253–260, 2013CrossRef Grams ME, et al.: Trends in the prevalence of reduced GFR in the United States: a comparison of creatinine- and cystatin C-based estimates. American journal of kidney diseases : the official journal of the National Kidney Foundation 62:253–260, 2013CrossRef
3.
Zurück zum Zitat Coresh J, et al.: Prevalence of chronic kidney disease in the United States. Jama 298:2038–2047, 2007CrossRefPubMed Coresh J, et al.: Prevalence of chronic kidney disease in the United States. Jama 298:2038–2047, 2007CrossRefPubMed
4.
Zurück zum Zitat White SL, Polkinghorne KR, Atkins RC, Chadban SJ: Comparison of the prevalence and mortality risk of CKD in Australia using the CKD Epidemiology Collaboration (CKD-EPI) and Modification of Diet in Renal Disease (MDRD) Study GFR estimating equations: the AusDiab (Australian Diabetes, Obesity and Lifestyle) Study. American journal of kidney diseases : the official journal of the National Kidney Foundation 55:660–670, 2010CrossRef White SL, Polkinghorne KR, Atkins RC, Chadban SJ: Comparison of the prevalence and mortality risk of CKD in Australia using the CKD Epidemiology Collaboration (CKD-EPI) and Modification of Diet in Renal Disease (MDRD) Study GFR estimating equations: the AusDiab (Australian Diabetes, Obesity and Lifestyle) Study. American journal of kidney diseases : the official journal of the National Kidney Foundation 55:660–670, 2010CrossRef
5.
Zurück zum Zitat Matsushita K, Tonelli M, Lloyd A, Levey AS, Coresh J, Hemmelgarn BR: Clinical risk implications of the CKD Epidemiology Collaboration (CKD-EPI) equation compared with the Modification of Diet in Renal Disease (MDRD) Study equation for estimated GFR. American journal of kidney diseases : the official journal of the National Kidney Foundation 60:241–249, 2012CrossRef Matsushita K, Tonelli M, Lloyd A, Levey AS, Coresh J, Hemmelgarn BR: Clinical risk implications of the CKD Epidemiology Collaboration (CKD-EPI) equation compared with the Modification of Diet in Renal Disease (MDRD) Study equation for estimated GFR. American journal of kidney diseases : the official journal of the National Kidney Foundation 60:241–249, 2012CrossRef
6.
Zurück zum Zitat Keller G, Zimmer G, Mall G, Ritz E, Amann K: Nephron number in patients with primary hypertension. The New England journal of medicine 348:101–108, 2003CrossRefPubMed Keller G, Zimmer G, Mall G, Ritz E, Amann K: Nephron number in patients with primary hypertension. The New England journal of medicine 348:101–108, 2003CrossRefPubMed
7.
Zurück zum Zitat Ritz E, Amann K, Koleganova N, Benz K: Prenatal programming-effects on blood pressure and renal function. Nature reviews Nephrology 7:137–144, 2011CrossRefPubMed Ritz E, Amann K, Koleganova N, Benz K: Prenatal programming-effects on blood pressure and renal function. Nature reviews Nephrology 7:137–144, 2011CrossRefPubMed
8.
Zurück zum Zitat Jones RA, Easley K, Little SB, Scherz H, Kirsch AJ, Grattan-Smith JD: Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: Part 1, functional assessment. AJR American journal of roentgenology 185:1598–1607, 2005CrossRefPubMed Jones RA, Easley K, Little SB, Scherz H, Kirsch AJ, Grattan-Smith JD: Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: Part 1, functional assessment. AJR American journal of roentgenology 185:1598–1607, 2005CrossRefPubMed
9.
Zurück zum Zitat Bakker J, Olree M, Kaatee R, de Lange EE, Beek FJ: In vitro measurement of kidney size: comparison of ultrasonography and MRI. Ultrasound in medicine & biology 24:683–688, 1998CrossRef Bakker J, Olree M, Kaatee R, de Lange EE, Beek FJ: In vitro measurement of kidney size: comparison of ultrasonography and MRI. Ultrasound in medicine & biology 24:683–688, 1998CrossRef
10.
Zurück zum Zitat Bakker J, et al.: Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging. Radiology 211:623–628, 1999CrossRefPubMed Bakker J, et al.: Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging. Radiology 211:623–628, 1999CrossRefPubMed
11.
Zurück zum Zitat Li S, et al.: Wavelet-based segmentation of renal compartments in DCE-MRI of human kidney: initial results in patients and healthy volunteers. Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society 36:108–118, 2012CrossRef Li S, et al.: Wavelet-based segmentation of renal compartments in DCE-MRI of human kidney: initial results in patients and healthy volunteers. Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society 36:108–118, 2012CrossRef
12.
Zurück zum Zitat Grenier N, Basseau F, Ries M, Tyndal B, Jones R, Moonen C: Functional MRI of the kidney. Abdominal imaging 28:164–175, 2003CrossRefPubMed Grenier N, Basseau F, Ries M, Tyndal B, Jones R, Moonen C: Functional MRI of the kidney. Abdominal imaging 28:164–175, 2003CrossRefPubMed
13.
Zurück zum Zitat Coulam CH, Bouley DM, Sommer FG: Measurement of renal volumes with contrast-enhanced MRI. Journal of magnetic resonance imaging : JMRI 15:174–179, 2002CrossRefPubMed Coulam CH, Bouley DM, Sommer FG: Measurement of renal volumes with contrast-enhanced MRI. Journal of magnetic resonance imaging : JMRI 15:174–179, 2002CrossRefPubMed
14.
Zurück zum Zitat de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC: MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 230:652–659, 2004CrossRefPubMed de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC: MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 230:652–659, 2004CrossRefPubMed
15.
Zurück zum Zitat Di Leo G, Di Terlizzi F, Flor N, Morganti A, Sardanelli F: Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: intraobserver, interobserver, and interstudy reproducibility. European journal of radiology 80:e212–216, 2011CrossRefPubMed Di Leo G, Di Terlizzi F, Flor N, Morganti A, Sardanelli F: Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: intraobserver, interobserver, and interstudy reproducibility. European journal of radiology 80:e212–216, 2011CrossRefPubMed
16.
Zurück zum Zitat Kanki A, et al.: Corticomedullary differentiation of the kidney: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP). Journal of magnetic resonance imaging : JMRI 37:1178–1181, 2013CrossRefPubMed Kanki A, et al.: Corticomedullary differentiation of the kidney: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP). Journal of magnetic resonance imaging : JMRI 37:1178–1181, 2013CrossRefPubMed
17.
Zurück zum Zitat Cohen BA, Barash I, Kim DC, Sanger MD, Babb JS, Chandarana H: Intraobserver and interobserver variability of renal volume measurements in polycystic kidney disease using a semiautomated MR segmentation algorithm. AJR American journal of roentgenology 199:387–393, 2012CrossRefPubMed Cohen BA, Barash I, Kim DC, Sanger MD, Babb JS, Chandarana H: Intraobserver and interobserver variability of renal volume measurements in polycystic kidney disease using a semiautomated MR segmentation algorithm. AJR American journal of roentgenology 199:387–393, 2012CrossRefPubMed
18.
Zurück zum Zitat Tang Y, Jackson HA, Filippo RED, Nelson MD, Jr, Moats RA: Automatic renal segmentation applied in pediatric MR Urography. IJIIP 1:12–19, 2010CrossRef Tang Y, Jackson HA, Filippo RED, Nelson MD, Jr, Moats RA: Automatic renal segmentation applied in pediatric MR Urography. IJIIP 1:12–19, 2010CrossRef
19.
Zurück zum Zitat Borgelt C, Timm H, Kruse R: Using fuzzy clustering to improve naive Bayes classifiers and probabilistic networks. Proc. Fuzzy Systems, 2000 FUZZ IEEE 2000 The Ninth IEEE International Conference on: City, 7-10 May 2000 Borgelt C, Timm H, Kruse R: Using fuzzy clustering to improve naive Bayes classifiers and probabilistic networks. Proc. Fuzzy Systems, 2000 FUZZ IEEE 2000 The Ninth IEEE International Conference on: City, 7-10 May 2000
20.
Zurück zum Zitat Sun Y, et al.: Improving spatiotemporal resolution of USPIO-enhanced dynamic imaging of rat kidneys. Magnetic resonance imaging 21:593–598, 2003CrossRefPubMed Sun Y, et al.: Improving spatiotemporal resolution of USPIO-enhanced dynamic imaging of rat kidneys. Magnetic resonance imaging 21:593–598, 2003CrossRefPubMed
21.
Zurück zum Zitat Vivier PH, Dolores M, Gardin I, Zhang P, Petitjean C, Dacher JN: In vitro assessment of a 3D segmentation algorithm based on the belief functions theory in calculating renal volumes by MRI. AJR American journal of roentgenology 191:W127–134, 2008CrossRefPubMed Vivier PH, Dolores M, Gardin I, Zhang P, Petitjean C, Dacher JN: In vitro assessment of a 3D segmentation algorithm based on the belief functions theory in calculating renal volumes by MRI. AJR American journal of roentgenology 191:W127–134, 2008CrossRefPubMed
22.
Zurück zum Zitat Karstoft K, Lodrup AB, Dissing TH, Sorensen TS, Nyengaard JR, Pedersen M: Different strategies for MRI measurements of renal cortical volume. Journal of magnetic resonance imaging : JMRI 26:1564–1571, 2007CrossRefPubMed Karstoft K, Lodrup AB, Dissing TH, Sorensen TS, Nyengaard JR, Pedersen M: Different strategies for MRI measurements of renal cortical volume. Journal of magnetic resonance imaging : JMRI 26:1564–1571, 2007CrossRefPubMed
23.
Zurück zum Zitat Cheong B, Muthupillai R, Rubin MF, Flamm SD: Normal values for renal length and volume as measured by magnetic resonance imaging. Clinical journal of the American Society of Nephrology : CJASN 2:38–45, 2007CrossRefPubMed Cheong B, Muthupillai R, Rubin MF, Flamm SD: Normal values for renal length and volume as measured by magnetic resonance imaging. Clinical journal of the American Society of Nephrology : CJASN 2:38–45, 2007CrossRefPubMed
24.
Zurück zum Zitat Gloger O, Tonies KD, Liebscher V, Kugelmann B, Laqua R, Volzke H: Prior shape level set segmentation on multistep generated probability maps of MR datasets for fully automatic kidney parenchyma volumetry. IEEE transactions on medical imaging 31:312–325, 2012CrossRefPubMed Gloger O, Tonies KD, Liebscher V, Kugelmann B, Laqua R, Volzke H: Prior shape level set segmentation on multistep generated probability maps of MR datasets for fully automatic kidney parenchyma volumetry. IEEE transactions on medical imaging 31:312–325, 2012CrossRefPubMed
25.
Zurück zum Zitat Will S, Martirosian P, Wurslin C, Schick F: Automated segmentation and volumetric analysis of renal cortex, medulla, and pelvis based on non-contrast-enhanced T1- and T2-weighted MR images. Magma (New York, NY) 27:445–454, 2014 Will S, Martirosian P, Wurslin C, Schick F: Automated segmentation and volumetric analysis of renal cortex, medulla, and pelvis based on non-contrast-enhanced T1- and T2-weighted MR images. Magma (New York, NY) 27:445–454, 2014
26.
Zurück zum Zitat Gonzalez Ballester MA, Zisserman AP, Brady M: Estimation of the partial volume effect in MRI. Medical image analysis 6:389–405, 2002CrossRefPubMed Gonzalez Ballester MA, Zisserman AP, Brady M: Estimation of the partial volume effect in MRI. Medical image analysis 6:389–405, 2002CrossRefPubMed
27.
Zurück zum Zitat Pham D, Kron T, Foroudi F, Schneider M, Siva S: A review of kidney motion under free, deep and forced-shallow breathing conditions: implications for stereotactic ablative body radiotherapy treatment. Technology in cancer research & treatment 13:315–323, 2014 Pham D, Kron T, Foroudi F, Schneider M, Siva S: A review of kidney motion under free, deep and forced-shallow breathing conditions: implications for stereotactic ablative body radiotherapy treatment. Technology in cancer research & treatment 13:315–323, 2014
28.
Zurück zum Zitat Gadeberg P, Gundersen HJ, Tagehoj F: How accurate are measurements on MRI? A study on multiple sclerosis using reliable 3D stereological methods. Journal of magnetic resonance imaging : JMRI 10:72–79, 1999CrossRefPubMed Gadeberg P, Gundersen HJ, Tagehoj F: How accurate are measurements on MRI? A study on multiple sclerosis using reliable 3D stereological methods. Journal of magnetic resonance imaging : JMRI 10:72–79, 1999CrossRefPubMed
Metadaten
Titel
Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images
Publikationsdatum
26.12.2016
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 2/2017
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-016-9936-3

Weitere Artikel der Ausgabe 2/2017

Journal of Digital Imaging 2/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.