Skip to main content
main-content

19.01.2017 | Ideas and Technical Innovations | Ausgabe 4/2017

European Spine Journal 4/2017

Development of a new assessment tool for cervical myelopathy using hand-tracking sensor: Part 1: validity and reliability

Zeitschrift:
European Spine Journal > Ausgabe 4/2017
Autoren:
M. Abdulhadi Alagha, Mahmoud A. Alagha, Eleanor Dunstan, Olaf Sperwer, Kate A. Timmins, Bronek M. Boszczyk
Wichtige Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1007/​s00586-017-4948-3) contains supplementary material, which is available to authorized users.

Abstract

Purpose

To assess the reliability and validity of a hand motion sensor, Leap Motion Controller (LMC), in the 15-s hand grip-and-release test, as compared against human inspection of an external digital camera recording.

Methods

Fifty healthy participants were asked to fully grip-and-release their dominant hand as rapidly as possible for two trials with a 10-min rest in-between, while wearing a non-metal wrist splint. Each test lasted for 15 s, and a digital camera was used to film the anterolateral side of the hand on the first test. Three assessors counted the frequency of grip-and-release (G-R) cycles independently and in a blinded fashion. The average mean of the three was compared with that measured by LMC using the Bland–Altman method. Test–retest reliability was examined by comparing the two 15-s tests.

Results

The mean number of G-R cycles recorded was: 47.8 ± 6.4 (test 1, video observer); 47.7 ± 6.5 (test 1, LMC); and 50.2 ± 6.5 (test 2, LMC). Bland–Altman indicated good agreement, with a low bias (0.15 cycles) and narrow limits of agreement. The ICC showed high inter-rater agreement and the coefficient of repeatability for the number of cycles was ±5.393, with a mean bias of 3.63.

Conclusions

LMC appears to be valid and reliable in the 15-s grip-and-release test. This serves as a first step towards the development of an objective myelopathy assessment device and platform for the assessment of neuromotor hand function in general. Further assessment in a clinical setting and to gauge healthy benchmark values is warranted.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Zusatzmaterial
Supplementary material 1 (DOCX 1780 kb)
586_2017_4948_MOESM1_ESM.docx
Supplementary material 1 (DOCX 697 kb)
586_2017_4948_MOESM2_ESM.docx
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 4/2017

European Spine Journal 4/2017 Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Orthopädie und Unfallchirurgie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Orthopädie und Unfallchirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise