Abstract

The aim of this work was to analyze a shrouded impeller pediatric ventricular assist device (SIP-VAD). This device has distinctive design characteristics and parameter optimizations for minimization of recirculation flow and reduction in high-stress regions that cause blood damage. Computational Fluid Dynamics (CFD) simulations were performed to analyze the optimized design. The bench-top prototype of SIP-VAD was manufactured with biocompatible stainless steel. A study on the hydrodynamic and hemodynamic performance of the SIP-VAD was conducted with predictions from CFD and actual experimentation values, and these results were compared. The CFD analysis yielded a pressure range of 29–90 mmHg corresponding to flow rates of 0.5–3 L/min over 9000–11000 rpm. The predicted value of the normalized index of hemolysis (NIH) was 0.0048 g/100 L. The experimental results with the bench-top prototype showed a pressure rise of 30–105 mmHg for the flow speed of 8000–12000 rpm and flow rate of 0.5–3.5 L/min. The maximum difference between CFD and experimental results was 4 mmHg pressure. In addition, the blood test showed the average NIH level of 0.00674 g/100 L. The results show the feasibility of shrouded impeller design of axial-flow pump for manufacturing the prototype for further animal trials.
Literatur
1.
Zurück zum Zitat Benjamin EJ, Blaha MJ, Chiuve SE, Cushman M, Das SR, Deo R, de Ferranti SD, Floyd J, Fornage M, Gillespie C. Heart disease and stroke statistics—2017 update: a report from the American Heart Association. Circulation. 2017;135(10):e146-e603.CrossRefPubMedPubMedCentral Benjamin EJ, Blaha MJ, Chiuve SE, Cushman M, Das SR, Deo R, de Ferranti SD, Floyd J, Fornage M, Gillespie C. Heart disease and stroke statistics—2017 update: a report from the American Heart Association. Circulation. 2017;135(10):e146-e603.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Wu J, Antaki JF, Verkaik J, Snyder S, Ricci M. Computational fluid dynamics-based design optimization for an implantable miniature Maglev pediatric ventricular assist device. J Fluids Eng. 2012;134(4):041101.CrossRef Wu J, Antaki JF, Verkaik J, Snyder S, Ricci M. Computational fluid dynamics-based design optimization for an implantable miniature Maglev pediatric ventricular assist device. J Fluids Eng. 2012;134(4):041101.CrossRef
3.
Zurück zum Zitat Almond CS, Thiagarajan RR, Piercey GE, Gauvreau K, Blume ED, Bastardi HJ, Fynn-Thompson F, Singh T. Waiting list mortality among children listed for heart transplantation in the United States. Circulation. 2009;119(5):717 – 27.CrossRefPubMedPubMedCentral Almond CS, Thiagarajan RR, Piercey GE, Gauvreau K, Blume ED, Bastardi HJ, Fynn-Thompson F, Singh T. Waiting list mortality among children listed for heart transplantation in the United States. Circulation. 2009;119(5):717 – 27.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Okamoto E, Ishida Y, Yano T, Mitamura Y. Passive magnetic bearing in the 3rd generation miniature axial flow pump-the valvo pump 2. J Artif Organs. 2015;18(2):181–4.CrossRefPubMed Okamoto E, Ishida Y, Yano T, Mitamura Y. Passive magnetic bearing in the 3rd generation miniature axial flow pump-the valvo pump 2. J Artif Organs. 2015;18(2):181–4.CrossRefPubMed
5.
Zurück zum Zitat Duncan BW, Lorenz M, Kopcak MW, Fukamachi K, Ootaki Y, Chen HM, Chapman PA, Davis SJ, Smith WA. The PediPump: a new ventricular assist device for children. Artif Organs. 2005;29(7):527 – 30.CrossRefPubMed Duncan BW, Lorenz M, Kopcak MW, Fukamachi K, Ootaki Y, Chen HM, Chapman PA, Davis SJ, Smith WA. The PediPump: a new ventricular assist device for children. Artif Organs. 2005;29(7):527 – 30.CrossRefPubMed
6.
Zurück zum Zitat Duncan BW. Mechanical circulatory support for infants and children with cardiac disease. Ann Thorac Surg. 2002;73(5):1670–7.CrossRefPubMed Duncan BW. Mechanical circulatory support for infants and children with cardiac disease. Ann Thorac Surg. 2002;73(5):1670–7.CrossRefPubMed
7.
Zurück zum Zitat Baldwin JT, Adachi I, Teal J, Almond CA, Jaquiss RD, Massicotte MP, Dasse K, Siami FS, Zak V, Kaltman JR. Closing in on the PumpKIN trial of the Jarvik 2015 ventricular assist device. In: Seminars in thoracic and cardiovascular surgery: pediatric cardiac surgery annual. Elsevier, pp. 9–15 (2017). Baldwin JT, Adachi I, Teal J, Almond CA, Jaquiss RD, Massicotte MP, Dasse K, Siami FS, Zak V, Kaltman JR. Closing in on the PumpKIN trial of the Jarvik 2015 ventricular assist device. In: Seminars in thoracic and cardiovascular surgery: pediatric cardiac surgery annual. Elsevier, pp. 9–15 (2017).
8.
Zurück zum Zitat Hsu C-H. Flow study on a newly developed impeller for a left ventricular assist device. J Artif Organs. 2003;6(2):92–100.PubMed Hsu C-H. Flow study on a newly developed impeller for a left ventricular assist device. J Artif Organs. 2003;6(2):92–100.PubMed
9.
Zurück zum Zitat Su B, Chua LP, Lim TM, Zhou T. Evaluation of the impeller shroud performance of an axial flow ventricular assist device using computational fluid dynamics. Artif Organs. 2010;34(9):745 – 59.CrossRefPubMed Su B, Chua LP, Lim TM, Zhou T. Evaluation of the impeller shroud performance of an axial flow ventricular assist device using computational fluid dynamics. Artif Organs. 2010;34(9):745 – 59.CrossRefPubMed
10.
Zurück zum Zitat Hara S, Maeno E, Li X, Yurimoto T, Isoyama T, Saito I, Ono T, Abe Y. Principle and basic property of the sequential flow pump. J Artif Organs. 2017:1–6. Hara S, Maeno E, Li X, Yurimoto T, Isoyama T, Saito I, Ono T, Abe Y. Principle and basic property of the sequential flow pump. J Artif Organs. 2017:1–6.
11.
Zurück zum Zitat Giersiepen M, Wurzinger L, Opitz R, Reul H. Estimation of shear stress-related blood damage in heart valve prostheses—in vitro comparison of 25 aortic valves. Int J Artif Organs. 1990;13(5):300–6.CrossRefPubMed Giersiepen M, Wurzinger L, Opitz R, Reul H. Estimation of shear stress-related blood damage in heart valve prostheses—in vitro comparison of 25 aortic valves. Int J Artif Organs. 1990;13(5):300–6.CrossRefPubMed
12.
Zurück zum Zitat Behbahani M, Behr M, Hormes M, Steinseifer U, Arora D, Coronado O, Pasquali M. A review of computational fluid dynamics analysis of blood pumps. Eur J Appl Math. 2009;20(04):363 – 97.CrossRef Behbahani M, Behr M, Hormes M, Steinseifer U, Arora D, Coronado O, Pasquali M. A review of computational fluid dynamics analysis of blood pumps. Eur J Appl Math. 2009;20(04):363 – 97.CrossRef
13.
Zurück zum Zitat Pauli L, Nam J, Pasquali M, Behr M. Transient stress-based and strain-based hemolysis estimation in a simplified blood pump. Int J Numer Methods Biomed Eng. 2013;29(10):1148–60.CrossRef Pauli L, Nam J, Pasquali M, Behr M. Transient stress-based and strain-based hemolysis estimation in a simplified blood pump. Int J Numer Methods Biomed Eng. 2013;29(10):1148–60.CrossRef
14.
Zurück zum Zitat Gesenhues L, Pauli L, Behr M. Strain-based blood damage estimation for computational design of ventricular assist devices. Int J Artif Organs. 2016;39:166–70.CrossRefPubMed Gesenhues L, Pauli L, Behr M. Strain-based blood damage estimation for computational design of ventricular assist devices. Int J Artif Organs. 2016;39:166–70.CrossRefPubMed
15.
Zurück zum Zitat Garon A, Farinas MI. Fast three-dimensional numerical hemolysis approximation. Artif Organs. 2004;28(11):1016–25.CrossRefPubMed Garon A, Farinas MI. Fast three-dimensional numerical hemolysis approximation. Artif Organs. 2004;28(11):1016–25.CrossRefPubMed
16.
Zurück zum Zitat Gradwohl RBH, Sonnenwirth AC, Jarett L. Gradwohl’s clinical laboratory methods and diagnosis. 8th ed. St. Louis: Mosby; 1980. Gradwohl RBH, Sonnenwirth AC, Jarett L. Gradwohl’s clinical laboratory methods and diagnosis. 8th ed. St. Louis: Mosby; 1980.
17.
Zurück zum Zitat Throckmorton AL, Kapadia JY, Chopski SG, Bhavsar SS, Moskowitz WB, Gullquist SD, Gangemi JJ, Haggerty CM, Yoganathan AP. Numerical, hydraulic, and hemolytic evaluation of an intravascular axial flow blood pump to mechanically support Fontan patients. Ann Biomed Eng. 2011;39(1):324 – 36.CrossRefPubMed Throckmorton AL, Kapadia JY, Chopski SG, Bhavsar SS, Moskowitz WB, Gullquist SD, Gangemi JJ, Haggerty CM, Yoganathan AP. Numerical, hydraulic, and hemolytic evaluation of an intravascular axial flow blood pump to mechanically support Fontan patients. Ann Biomed Eng. 2011;39(1):324 – 36.CrossRefPubMed
Metadaten
Titel
Development of a novel shrouded impeller pediatric blood pump
verfasst von
Talha Irfan Khan
Haris Sheh Zad
Ismail Lazoglu
Ozlem Yalcin
Publikationsdatum
24.02.2018
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 2/2018
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-018-1028-3

Weitere Artikel der Ausgabe 2/2018

Journal of Artificial Organs 2/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.