Skip to main content
Erschienen in: Archives of Osteoporosis 1/2022

01.12.2022 | Original Article

Development of an open-source measurement system to assess the areal bone mineral density of the proximal femur from clinical CT images

verfasst von: Keisuke Uemura, Yoshito Otake, Masaki Takao, Hiroki Makino, Mazen Soufi, Makoto Iwasa, Nobuhiko Sugano, Yoshinobu Sato

Erschienen in: Archives of Osteoporosis | Ausgabe 1/2022

Einloggen, um Zugang zu erhalten

Abstract

Summary

Commercial software is generally needed to measure the areal bone mineral density (aBMD) of the proximal femur from clinical computed tomography (CT) images. This study developed and verified an open-source reproducible system to quantify CT-aBMD to screen osteoporosis using clinical CT images.

Purpose

For existing CT images acquired for various reasons other than osteoporosis, it might be beneficial to estimate areal BMD as assessed by dual-energy X-ray absorptiometry (DXA-based BMD) to ascertain the bone status based on DXA. In this study, we aimed to (1) develop an open-source reproducible measurement system to quantify DXA-based BMD from CT images and (2) validate its accuracy.

Methods

This study analyzed 75 pairs of hip CT and DXA images of women that were acquired for the preoperative assessment of total hip arthroplasty. From the CT images, the femur and a calibration phantom were automatically segmented using pre-trained codes/models available at https://​github.​com/​keisuke-uemura. The proximal femoral region was isolated by manually selected landmarks and was projected onto the coronal plane to measure the areal density (CT-aHU). The calibration phantom was employed to convert the CT-aHU into CT-aBMD. Each parameter was correlated with DXA-based BMD, and the residual errors of CT images to estimate the T-scores in DXA were calculated using the standard error of estimate (SEE).

Results

The correlation coefficients of DXA-based BMD with CT-aHU and CT-aBMD were 0.947 and 0.950, respectively (both p < 0.001). The SEE for quantifying the T-scores in DXA were 0.51 and 0.50 for CT-aHU and CT-aBMD, respectively.

Conclusion

With the method developed herein, CT permits estimation of the DXA-based BMD of the proximal femur within the standard DXA total hip region of interest with an SEE of 0.5 in T-scores. The radiation dose for CT acquisition needs consideration; therefore, our data do not provide a rationale for performing CT for screening osteoporosis. However, on CT images already acquired for clinical indications other than osteoporosis, researchers may use this open-source system to investigate osteoporosis status through the estimated DXA-based BMD of the proximal femur.
Literatur
11.
16.
Zurück zum Zitat Styner M, Lee J, Chin B, et al 3D Segmentation in the clinic: a grand challenge II: MS lesion segmentation. 6 Styner M, Lee J, Chin B, et al 3D Segmentation in the clinic: a grand challenge II: MS lesion segmentation. 6
21.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
Metadaten
Titel
Development of an open-source measurement system to assess the areal bone mineral density of the proximal femur from clinical CT images
verfasst von
Keisuke Uemura
Yoshito Otake
Masaki Takao
Hiroki Makino
Mazen Soufi
Makoto Iwasa
Nobuhiko Sugano
Yoshinobu Sato
Publikationsdatum
01.12.2022
Verlag
Springer London
Erschienen in
Archives of Osteoporosis / Ausgabe 1/2022
Print ISSN: 1862-3522
Elektronische ISSN: 1862-3514
DOI
https://doi.org/10.1007/s11657-022-01063-3

Weitere Artikel der Ausgabe 1/2022

Archives of Osteoporosis 1/2022 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.