Abstract

Background

A novel method, termed loop-mediated isothermal amplification (LAMP), was developed by Notomi et al. (2000). Individually published results have been reported that this technology has been successfully applied to the detection of a variety of pathogens. However, the overall diagnostic accuracy of LAMP for Mycoplasma pneumoniae (MP) remains unclear. A meta-analysis was therefore performed to review the accuracy of LAMP for Mycoplasma pneumoniae.

Methods

Cochrane Library and PubMed were systematically searched and checked for studies using LAMP for detecting mycoplasma pneumoniae. We used PCR as a reference standard to evaluate the quality of the studies eligible for inclusion in the meta-analysis. Then, the data from the studies were extracted by two independent assessors. Meta-DiSc 1.4 software was utilized to test the heterogeneity of sensitivity (SEN), specificity (SP), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnosis odds ratio (DOR). The pooled analysis results were plotted, and the summary receiver operating characteristic (SROC) curve was plotted by calculating the area under the curve (AUC). Generated pooled summary estimates (95% CIs) were calculated for the overall accuracy, and a bivariate meta-regression model was used for the meta-analysis.

Results

Seven studies with nine fourfold tables were included in this meta-analysis. The pooled SEN and SPE for diagnosing Mycoplasma pneumoniae were 0.90 (95% CI: 0.87–0.93) and 0.98 (95% CI: 0.96–0.99), respectively. The PLR was 31.25 (95% CI: 14.83–65.87), NLR 0.10 (95% CI: 0.05–0.22), DOR 399.32 (95% CI: 172.01–927.00), and AUC 0.9892.

Conclusions

In conclusion, compared with PCR, LAMP is a valuable alternative method for Mycoplasma pneumoniae diagnosis in clinic with high sensitivity and specificity. However, more evidence is required to confirm that LAMP can fully replace other methods in the clinical diagnosis of MP.
Abkürzungen
AUC
Area under the curve
CI
Confidence intervals
DOR
Diagnostic odds ratio
LAPM
Loop-mediated isothermal amplification
MP
Mycoplasma pneumoniae
NLR
Negative likelihood ratio
OR
Odds ratio
PCR
Polymerase chain reaction
PLR
Positive likelihood ratio
PRISMA
Preferred Reporting Items for Systematic Reviews and Meta-Analyses
QUADAS
Quality assessment of diagnostic accuracy studies
SEN
Sensitivity
SP
Specificity
SROC
Summary receiver operating characteristic

Background

Mycoplasma pneumoniae (MP) is the major pathogen causing human Mycoplasma pneumonia, which accounts for approximately 20–30% of all types of pneumonia worldwide [1, 2]. Prospective investigations support the notion that it has been the most common bacterial etiology in upper respiratory tract infections [3]. MP infection not only causes upper and lower respiratory disease, but also affects other systems of the human body, whose severity ranges from mild to life-threatening [49].The laboratory identification of the etiology of such organisms that lack a cell wall is critical to the determination of the correct course of treatment. Three common methods exist for the identification of MP infection: culture separation, serological tests, and PCR. Obviously, the gold standard for diagnosis of MP infection is MP culture separation. However, culture is not routinely applied for MP diagnosis in clinic due to the need for special medium, extensive time consumption, cumbersome experimental conditions, a relatively lower detection rate, and the delayed confirmation of MP infection, which is generally too slow to be of practical use. Another reliable detection method, PCR [10], is more widely implemented for diagnosis because it is more time-efficient and sensitive. Nevertheless, it also requires expensive equipment, molecular biology facilities, and experienced experimenters, which are not always available in smaller laboratory. As a consequence, PCR is not appropriate for application in primary hospitals, too. Serological tests diagnosis is frequently invalid because the tests are usually positive one–two weeks or more after the disease onset [11], and thus it is difficult to implement the results of such testing to actual treatment decisions.
In 2000,Notomi et al. developed a method with high specificity and efficiency to amplify DNA rapidly under isothermal conditions, which was called loop-mediated isothermal amplification [12].Many reports confirmed the successful application of this technology to the detection of a variety of pathogens [1316].Additionally, according to previous reports, the LAMP assay has sensitivity for detecting MP that is almost identical to that of PCR [17, 18] and is simpler to operate and less expensive than PCR. However, the overall diagnostic accuracy of LAMP for Mycoplasma pneumoniae remains unclear. The main purpose of the present study was to validate that LAMP is a more congruent method for application of the results obtained to actual treatment decisions in both superior and primary hospitals.

Methods

Electronic searches

We conducted a full search on PubMed and the Cochrane library from January 2000 to September 2018 using the keywords Mycoplasma pneumoniae, LAMP. The following search stratagem was utilized: ((Mycoplasma pneumoniae) AND (loop-mediated isothermal amplification OR LAMP)). The search was supplemented by inspection of the bibliographies of the articles retrieved. No language restrictions were applied to the search

Study screening and selection

Two investigators independently screened the potentially relevant publications by examining the full-text. Upon completion of the independent screening, two investigators cross-checked the results and discussed the existing differences, followed by making a decision on whether to include them or not. If the results were inconsistent, third investigators were included and all assessed the results together. All studies meeting the eligibility criteria were included in this analysis

Inclusion and exclusion criteria

Studies were included if (i) human samples were analyzed; (ii) diagnostic accuracy studies that compared LAMP with PCR for detecting MP; the latter were employed as the gold standard; (iii) the generated data were sufficient to construct 2•2 tables for calculating the sensitivity, specificity, and likelihood ratios
Studies were not included if: (i) The sample were from animals or other species; (ii)The gold standards were not used among the PCR samples— assayed for the detection of MP, or the study did not implement a LAMP assay; (iii) Possible duplicate publications, when an author published it more than once.

Data extraction

The extracted data included the title of the article, author, publication year, country, the number of included specimens, gold standard, detection method, true positive, false positive, true negative, and false negative. We extracted the data and constructed the 2•2 table.

Quality assessment

Two researchers independently assessed the articles included, using unified quality evaluation form, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) as a standard. The study QUADAS-2 quality criteria are given by Review Manager 5.2, which consists of four domains (patient selection, index test, reference standard, and flow and timing). These were used to assess the risk of bias, whereas the assessment of the first three was to be taken into consideration in the clinical applicability evaluation.

Statistical analysis

Using meta-DiSc 1.4 software, two investigators independently analyzed the data recommended for meta-analysis of the diagnostic studies: Sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and 95% confidence intervals (CI). If this information was not available, the respective values were calculated from the data provided in the article. We calculated and analyzed spearman correlation coefficient to estimate the heterogeneity of the studies, including the threshold and the nonthreshold effects. When a heterogeneity effect was present, the combined statistics were calculated using the random-effect model. When no heterogeneity effect was available, the fixed-effect model was implemented

Results

Characteristics of the included studies

Based on the search stratagem specified earlier, we obtained a total number of 26 articles, which decreased to 24 after the duplicates were removed. Then, by screening the titles and abstracts, and excluding the ineligible studies, we finally included seven articles, (Fig. 1), which were selected for full-text review and meta-analysis [1824]. From these seven articles, we extracted nine groups of data, consisting of a total number of 1325 samples. The characteristics of these studies are summarized in Table 1.
Table 1
Characteristics of the included studies
Studies included
Country
Mycoplasma pneumonia patients
Control group
Mycoplasma pneumonia patients included in the staging
Detection method
Company of the reagent source
Gold standard
Blind
Value of the positive judgment
Results
FN
TP
FP
TN
Ryoichi Saito, 2005
Japan
6
89
No
LAMP
1.Roche Diagnostics
Real-time PCR
yes
2 × 10 2
6
0
89
0
2.Qiagen
3.Applied Biosystems
FEI ZHAO, 2013
China
21
59
No
LAMP
Qiagen
Real-time PCR
yes
unclear
21
5
54
0
Amy E. Ratliff II, 2014
American
22
192
No
LAMP
1.Qiagen
Real-time PCR
yes
C T ≤ 42.0
22
2
190
0
2.Agilent
Brianna L. Petrone, 2015
American
226
26
No
LAMP
1.Roche Applied Science
Real-time PCR
yes
CT < 30
200
1
25
26
2.Thermo Scientific
3.MP Biomedicals
Brianna L. Petrone, 2015
American
39
33
No
LAMP
1.Roche Applied Science
Real-time PCR
yes
CT ≥ 30
32
0
33
7
2.Thermo Scientific
3.MP Biomedicals
Fujio Kakuya, 2017
Japan
58
43
NO
LAMP
1.Eiken Chemical
Real-time PCR
Yes
an MP DNA load of> = 4.5 copies/μL
15
0
43
0
2.Asahi Kasei Pharma
Fujio Kakuya, 2017
Japan
58
50
NO
LAMP
1.Eiken Chemical
Real-time PCR
Yes
an MP DNA load of> = 4.5 copies/μL
8
0
43
7
2.Asahi Kasei Pharma
Ho Namkoong, 2018
Japan
73
84
No
LAMP
1. Mizuho Medy
Real-time PCR
yes
unclear
70
1
83
3
1. Fujifilm
2. Asahi Kasei Pharma
Xin Yuan, 2018
China
116
9
No
LAMP
1. Oxoid
Real-time PCR
yes
unclear
37
6
3
79
2. New England Biolabs
3. Da An Gene Co,
4. Sinopharm Chemical Reagents
5. Shanghai Simco Biotech
6. Beijing Mylab Corporation
TP true positive, FP false positive, FN false negative, TN true negative

Methodological quality

Using Review Manager 5.3, we drew a conclusion that most studies were at a low risk of bias and low concern regarding the applicability of their results. Nine studies meet all four domains of the criteria, whose quality assessment for the individual studies result are presented in Fig. 2. In addition, the overall risk of bias and applicability concerns for the seven selected articles can be seen in Fig. 3. In the patient selection domain, approximately 80% of the studies were at low risk of bias, because they enrolled participants consecutively and avoided inappropriate exclusions. The remaining study was graded as being at high risk of bias as it had a case-control design. In the index test domain, we considered the majority of studies to be at unclear risk of bias (60%), because most of the articles’ thresholds were unclear, or the index test was interpreted with knowledge of the results of the reference standard. The remaining studies were judged to be at low risk. In the reference standard domain, we assigned 80% of studies to be at low risk of bias, because it was stated that the reference standard results were interpreted without knowledge of the results of the index test. Applicability was of low concern for all studies in the reference standard domain. In the flow and timing domain, all studies were judged to be at low risk of bias because all patients were included in the analysis, the appropriate reference standard was used, and an appropriate interval between the index test and the reference standard was available.

Publication Bias

No publication bias was found in the Deek’s funnel plot (Fig. 4). The Egger test indicated that the current publication bias of the study was low (P = 0.261).

Threshold effect analysis

In the analysis of the threshold effect, the Spearman correlation coefficient = 0.100; P-value = 0.797 (P > 0. 05) were applied. Moreover, we analyzed the SROC curve (Fig. 5), which was not characterized by a “shoulder arm” distribution. Thus, we concluded that no threshold effect was present among the articles included.

Heterogeneity analysis of non - threshold effect

A forest map with a random pattern was used to draw the ratio. As can be observed in Fig. 6, the following values were obtained: Cochran-Q = 8.30, P = 0.4050 (P > 0. 05), and the inconsistency = 3.6% (inconsistency < 50%), indicating that the absence of heterogeneity in the non-threshold effect.

SROC curve

A fixed-effect model was adopted to fit the SROC curve. As can be seen in Fig. 5, AUC = 0.9892, and the Q index was 0.9566 (SE = 0.0128). We, therefore, suggested that the detection of MP infection by LAMP was of high accuracy.

Merge analysis results

The results are shown in Figs. 7, 8, 9 and 10. LAMP technology was employed to detect mycoplasma pneumoniae merger sensitivity, specificity, positive LR, and negative LR, whose values were respectively 0.90 (95% CI (0.87, 0.93), 0.98 (95% CI (0.96, 0.99)), 31.25(95% CI (14.83, 65.57)), and 0.10 (95% CI (0.05, 0.22)), correspondingly; the value of the pooled diagnostic odds ratio was 399.32 (95% CI (172.01, 927.00)].

Discussion

In this study, we conducted a thorough search by the application of strict screening criteria and finally included seven articles. Nine 2*2 tables on the diagnosis of Mycoplasma Pneumoniae by LAMP were carried out. The results of the quality evaluation showed that the combined sensitivity and specificity of LAMP in the diagnosis of Mycoplasma Pneumoniae were 0.90 and 0.98; the negative likelihood ratio, positive likelihood ratio and diagnostic ratio were 0.10, 31.25, and 399.32, respectively. The SROC AUC was 0.9892, which indicated high sensitivity and specificity of LAMP in the diagnosis of Mycoplasma Pneumoniae. The SROC curve was close to the upper left corner; that is, the area under the curve was extremely large. Thus, LAMP is highly accurate in the diagnosis of Mycoplasma Pneumoniae. According to the analysis of the four studies included in the analysis conducted by the STATICS software, the bias coefficient was P = 0.108 > 0.05, indicating that the probability of publication bias was subtle.
PCR and culture are widely used as the gold standard for the detection of Mycoplasma Pneumoniae, but there are some limitations to their wide clinic application. First, the MP culture separation requires a special culture medium and a long time. Furthermore, the experimental protocol is cumbersome, resulting in a low detection rate. Hence the isolation and culture are not suitable for the early clinical diagnosis of MP infection. In addition, PCR, the technique most commonly used at the early diagnosis stage in clinical practice, requires only a small amount of MP-DNA fragments and possesses high sensitivity and specificity of detection. Nevertheless, PCR has high requirements for operators, needs expensive equipment, and requires high standards on sample collection, storage, and processing. Hence, it cannot be broadly applied in major primary hospitals. On the other hand, LAMP has some potential advantages, such as high sensitivity, high specificity, a wide detection range, which is comparable to that of PCR, but is simpler in terms of equipment and instruments used. Moreover, LAMP has high throughput that is achieved fast and without dependence on specialized equipment. Meanwhile, the assay is simple to perform; only one-week training is needed even for technicians with no prior molecular analysis experience. Moreover, the result is convenient to observe, the white turbid or green fluorescence can be directly seen by naked eye. Due to the on the above advantages, Mycoplasma pneumoniae can be detected in the early stage of disease. Since the first publication of the official report on this technology by Notomi in 2000, LAMP has been widely used in many life sciences for the detection of pathogens causing diseases, such as malaria, trypanosomiasis, and babesiosis
Nonetheless, the overall clinical accuracy of LAMP for the detection of Mycoplasma Pneumoniae has to be further studied. Also, many investigations mentioned that LAMP still has some weaknesses to be overcome. First, LAMP stability is poorer than PCR. Meanwhile, LAMP had a shorter total reaction time.
Due to the limited data reported of the tested samples, the too small sample size, and the lack of comparability, no group evaluation was conducted. The sensitivity and specificity were calculated only based on the number of subjects involved. However, in clinical settings, this part of the data for laboratory tests of different samples is of substantial significance and should be more carefully considered. Hence, this analysis needs to be further improved after the increase of clinical data accumulated in the future.
In summary, LAMP is a method with high sensitivity and specificity when used for the diagnosis of Mycoplasma Pneumoniae. LAMP is a rapid, sensitive, and specific detection method that is valuable for the early clinical diagnosis of Mycoplasma Pneumoniae. Notably, it can be used to guide the overall clinical treatment and considerably contribute to the prevention of epidemic and complications. Furthermore, it can lead to a reduction in the abusive application of antibiotics; it shortens the duration of treatment, and efficiently improves the initial treatment of patients, decreasing the patient’s pain and economic burden. Along with the advancement of the LAMP technology, LAMP can probably become a primary auxiliary diagnosis choice for Mycoplasma Pneumoniae in the near future.

Conclusions

In summary, we used PCR as the golden standard that have long been applied in the clinical diagnosis of Mycoplasma Pneumoniae. Our study provides a valuable reference for another method with high sensitivity and specificity, as well as time efficiency and convenience. However, more clinical data are needed to support our conclusion.

Acknowledgements

We express our sincere gratitude to all members of our study team for their whole-hearted cooperation and to the original authors of the studies included for their wonderful work and valuable participation.

Funding

No funding was used to support this study.

Availability of data and materials

All data generated or analyzed during this study are included in this published article and its supplementary information files.
Not applicable.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Cao B, Ren LL, Zhao F, et al. Viral and mycoplasma pneumoniae community-acquired pneumonia and novel clinical outcome evaluation in ambulatory adult patients in China. Eur J Clin Microbiol Infect Dis. 2010;29(11):1443–8.CrossRef Cao B, Ren LL, Zhao F, et al. Viral and mycoplasma pneumoniae community-acquired pneumonia and novel clinical outcome evaluation in ambulatory adult patients in China. Eur J Clin Microbiol Infect Dis. 2010;29(11):1443–8.CrossRef
2.
Zurück zum Zitat Liu Y, Chen M, Zhao T, et al. Causative agent distribution and antibiotic therapy assessment among adult patients with community acquired pneumonia in Chinese urban population. BMC Infect Dis. 2009;9:31.CrossRef Liu Y, Chen M, Zhao T, et al. Causative agent distribution and antibiotic therapy assessment among adult patients with community acquired pneumonia in Chinese urban population. BMC Infect Dis. 2009;9:31.CrossRef
3.
Zurück zum Zitat Waites KB, Xiao L, Liu Y, Balish MF, Atkinson TP. Mycoplasma pneumoniae from the respiratory tract and beyond. Clin Microbiol Rev. 2017;30(3):747–809.CrossRef Waites KB, Xiao L, Liu Y, Balish MF, Atkinson TP. Mycoplasma pneumoniae from the respiratory tract and beyond. Clin Microbiol Rev. 2017;30(3):747–809.CrossRef
4.
Zurück zum Zitat Cunha BA. The atypical pneumonias: clinical diagnosis and importance. Clin Microbiol Infect. 2006;12(Suppl 3):12–24.CrossRef Cunha BA. The atypical pneumonias: clinical diagnosis and importance. Clin Microbiol Infect. 2006;12(Suppl 3):12–24.CrossRef
5.
Zurück zum Zitat Varma-Basil M, Dwivedi SK, Kumar K, et al. Role of mycoplasma pneumoniae infection in acute exacerbations of chronic obstructive pulmonary disease. J Med Microbiol. 2009;58(Pt 3):322–6.CrossRef Varma-Basil M, Dwivedi SK, Kumar K, et al. Role of mycoplasma pneumoniae infection in acute exacerbations of chronic obstructive pulmonary disease. J Med Microbiol. 2009;58(Pt 3):322–6.CrossRef
6.
Zurück zum Zitat Waites KB, Balish MF, Atkinson TP. New insights into the pathogenesis and detection of mycoplasma pneumoniae infections. Future Microbiol. 2008;3(6):635–48.CrossRef Waites KB, Balish MF, Atkinson TP. New insights into the pathogenesis and detection of mycoplasma pneumoniae infections. Future Microbiol. 2008;3(6):635–48.CrossRef
7.
Zurück zum Zitat Waites KB, Talkington DF. Mycoplasma pneumoniae and its role as a human pathogen. Clin Microbiol Rev. 2004;17(4):697–728 table of contents.CrossRef Waites KB, Talkington DF. Mycoplasma pneumoniae and its role as a human pathogen. Clin Microbiol Rev. 2004;17(4):697–728 table of contents.CrossRef
8.
Zurück zum Zitat Wood PR, Kampschmidt JC, Dube PH, et al. Mycoplasma pneumoniae and health outcomes in children with asthma. Ann Allergy Asthma Immunol. 2017;119(2):146–152.e2.CrossRef Wood PR, Kampschmidt JC, Dube PH, et al. Mycoplasma pneumoniae and health outcomes in children with asthma. Ann Allergy Asthma Immunol. 2017;119(2):146–152.e2.CrossRef
9.
Zurück zum Zitat Zhang Y, Mei S, Zhou Y, Huang M, Dong G, Chen Z. Cytokines as the good predictors of refractory mycoplasma pneumoniae pneumonia in school-aged children. Sci Rep. 2016;6:37037.CrossRef Zhang Y, Mei S, Zhou Y, Huang M, Dong G, Chen Z. Cytokines as the good predictors of refractory mycoplasma pneumoniae pneumonia in school-aged children. Sci Rep. 2016;6:37037.CrossRef
10.
Zurück zum Zitat Spuesens EB, Fraaij PL, Visser EG, et al. Carriage of mycoplasma pneumoniae in the upper respiratory tract of symptomatic and asymptomatic children: an observational study. PLoS Med. 2013;10(5):e1001444.CrossRef Spuesens EB, Fraaij PL, Visser EG, et al. Carriage of mycoplasma pneumoniae in the upper respiratory tract of symptomatic and asymptomatic children: an observational study. PLoS Med. 2013;10(5):e1001444.CrossRef
11.
Zurück zum Zitat Song M, Zhang Y, Li S, et al. A sensitive and rapid immunoassay for mycoplasma pneumoniae in children with pneumonia based on single-walled carbon nanotubes. Sci Rep. 2017;7(1):16442.CrossRef Song M, Zhang Y, Li S, et al. A sensitive and rapid immunoassay for mycoplasma pneumoniae in children with pneumonia based on single-walled carbon nanotubes. Sci Rep. 2017;7(1):16442.CrossRef
12.
Zurück zum Zitat Notomi T, Okayama H, Masubuchi H, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28(12):E63.CrossRef Notomi T, Okayama H, Masubuchi H, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28(12):E63.CrossRef
13.
Zurück zum Zitat Lamb LE, Bartolone SN, Tree MO, et al. Rapid detection of Zika virus in urine samples and infected mosquitos by reverse transcription-loop-mediated isothermal amplification. Sci Rep. 2018;8(1):3803.CrossRef Lamb LE, Bartolone SN, Tree MO, et al. Rapid detection of Zika virus in urine samples and infected mosquitos by reverse transcription-loop-mediated isothermal amplification. Sci Rep. 2018;8(1):3803.CrossRef
14.
Zurück zum Zitat Lucchi NW, Demas A, Narayanan J, et al. Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria. PLoS One. 2010;5(10):e13733.CrossRef Lucchi NW, Demas A, Narayanan J, et al. Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria. PLoS One. 2010;5(10):e13733.CrossRef
15.
Zurück zum Zitat Boehme CC, Nabeta P, Henostroza G, et al. Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries. J Clin Microbiol. 2007;45(6):1936–40.CrossRef Boehme CC, Nabeta P, Henostroza G, et al. Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries. J Clin Microbiol. 2007;45(6):1936–40.CrossRef
16.
Zurück zum Zitat Parida M, Posadas G, Inoue S, Hasebe F, Morita K. Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of West Nile virus. J Clin Microbiol. 2004;42(1):257–63.CrossRef Parida M, Posadas G, Inoue S, Hasebe F, Morita K. Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of West Nile virus. J Clin Microbiol. 2004;42(1):257–63.CrossRef
17.
Zurück zum Zitat Matsuda C, Taketani T, Takeuchi S, et al. Usefulness of the Loopamp mycoplasma P detecting reagent kit developed based on the LAMP method. Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi. 2013;23(2):53–9.PubMed Matsuda C, Taketani T, Takeuchi S, et al. Usefulness of the Loopamp mycoplasma P detecting reagent kit developed based on the LAMP method. Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi. 2013;23(2):53–9.PubMed
18.
Zurück zum Zitat Ratliff AE, Duffy LB, Waites KB. Comparison of the illumigene mycoplasma DNA amplification assay and culture for detection of mycoplasma pneumoniae. J Clin Microbiol. 2014;52(4):1060–3.CrossRef Ratliff AE, Duffy LB, Waites KB. Comparison of the illumigene mycoplasma DNA amplification assay and culture for detection of mycoplasma pneumoniae. J Clin Microbiol. 2014;52(4):1060–3.CrossRef
19.
Zurück zum Zitat Namkoong H, Yamazaki M, Ishizaki M, et al. Clinical evaluation of the Immunochromatographic system using silver amplification for the rapid detection of mycoplasma pneumoniae. Sci Rep. 2018;8(1):1430.CrossRef Namkoong H, Yamazaki M, Ishizaki M, et al. Clinical evaluation of the Immunochromatographic system using silver amplification for the rapid detection of mycoplasma pneumoniae. Sci Rep. 2018;8(1):1430.CrossRef
20.
Zurück zum Zitat Yuan X, Bai C, Cui Q, et al. Rapid detection of mycoplasma pneumoniae by loop-mediated isothermal amplification assay. Medicine (Baltimore). 2018;97(25):e10806.CrossRef Yuan X, Bai C, Cui Q, et al. Rapid detection of mycoplasma pneumoniae by loop-mediated isothermal amplification assay. Medicine (Baltimore). 2018;97(25):e10806.CrossRef
21.
Zurück zum Zitat Kakuya F, Kinebuchi T, Okubo H, Matsuo K. Comparison of oropharyngeal and nasopharyngeal swab specimens for the detection of mycoplasma pneumoniae in children with lower respiratory tract infection. J Pediatr. 2017;189:218–21.CrossRef Kakuya F, Kinebuchi T, Okubo H, Matsuo K. Comparison of oropharyngeal and nasopharyngeal swab specimens for the detection of mycoplasma pneumoniae in children with lower respiratory tract infection. J Pediatr. 2017;189:218–21.CrossRef
22.
Zurück zum Zitat Petrone BL, Wolff BJ, DeLaney AA, Diaz MH, Winchell JM. Isothermal detection of mycoplasma pneumoniae directly from respiratory clinical specimens. J Clin Microbiol. 2015;53(9):2970–6.CrossRef Petrone BL, Wolff BJ, DeLaney AA, Diaz MH, Winchell JM. Isothermal detection of mycoplasma pneumoniae directly from respiratory clinical specimens. J Clin Microbiol. 2015;53(9):2970–6.CrossRef
23.
Zurück zum Zitat Zhao F, Liu Z, Gu Y, et al. Detection of mycoplasma pneumoniae by colorimetric loop-mediated isothermal amplification. Acta Microbiol Immunol Hung. 2013;60(1):1–9.CrossRef Zhao F, Liu Z, Gu Y, et al. Detection of mycoplasma pneumoniae by colorimetric loop-mediated isothermal amplification. Acta Microbiol Immunol Hung. 2013;60(1):1–9.CrossRef
24.
Zurück zum Zitat Saito R, Misawa Y, Moriya K, Koike K, Ubukata K, Okamura N. Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of mycoplasma pneumoniae. J Med Microbiol. 2005;54(Pt 11):1037–41.CrossRef Saito R, Misawa Y, Moriya K, Koike K, Ubukata K, Okamura N. Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of mycoplasma pneumoniae. J Med Microbiol. 2005;54(Pt 11):1037–41.CrossRef
Metadaten
Titel
Diagnosis of mycoplasma pneumoniae by loop-mediated isothermal amplification: systematic review and meta-analysis
verfasst von
Zi-Hong Cai
Yuan-Yuan Dai
Lin-Yan Huang
Wen-Sheng Zhang
Xu-Guang Guo
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
BMC Infectious Diseases / Ausgabe 1/2019
Elektronische ISSN: 1471-2334
DOI
https://doi.org/10.1186/s12879-019-3799-4

Weitere Artikel der Ausgabe 1/2019

BMC Infectious Diseases 1/2019 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.