Diagnostic Accuracy of Caries and Periapical Lesions on a Monitor with and without DICOM-GSDF Calibration Under Different Ambient Light Conditions

verfasst von: Rangel Teles Freire, Agnaldo Rocha Prata-Júnior, John Nadson Andrade Pinho, Wilton Mitsunari Takeshita

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2022

Einloggen, um Zugang zu erhalten

Abstract

To evaluate the diagnostic accuracy of caries and periapical lesions on a monitor with and without DICOM part 14: grayscale standard display function (DICOM-GSDF) calibration under different ambient light conditions. Forty digital bitewing radiographs were selected, with or without radiographic images of carious lesions and forty digital periapical radiographs with or without periapical lesions were selected from archives of the Radiology Department at the University Hospital of the Federal University of Sergipe. The gold standard radiographic images were determined through consensus between two radiologists with more than 15 and 30 years of experience. The selected radiographs were evaluated on a LG LED monitor with and without DICOM-GSDF calibration under different ambient light conditions: Lx1 (low ambient lighting), Lx2 (moderate ambient lighting) and Lx3 (high ambient lighting). Kappa (Kw) values determined that evaluator 1 showed almost perfect agreement for all devices, while evaluator 2 presented a substantial agreement for all devices. Monitors with and without DICOM-GSDF calibration have similar accuracy values. The three ambient light conditions analyzed have similar accuracy and can be used for caries lesions diagnosis (p > 0.05); however, the best diagnostic accuracy of periapical lesions was found in Lx 2. The displays with and without DICOM-GSDF calibration studied in this research have similar accuracy and can be used to evaluate digital radiographs without changing the diagnostic capacity. The different ambient lighting conditions did not influence the evaluation of caries lesions. The best diagnostic accuracy of periapical lesions was found in moderate ambient lighting.
Literatur
3.
Zurück zum Zitat Takeshita WM, Vessoni Iwaki LC, Da Silva MC, Filho LI, Queiroz Ade F, Geron LB: Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography. Contemp Clin Dent 4(3):338–342, 2013. https://doi.org/10.4103/0976-237X.118391. Takeshita WM, Vessoni Iwaki LC, Da Silva MC, Filho LI, Queiroz Ade F, Geron LB: Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography. Contemp Clin Dent 4(3):338–342, 2013. https://​doi.​org/​10.​4103/​0976-237X.​118391.
5.
Zurück zum Zitat Kallio-Pulkkinen S, Haapea M, Liukkonen E, Huumonen S, Tervonen O, Nieminen MT: Comparison between DICOM-calibrated and uncalibrated consumer grade and 6-MP displays under different lighting conditions in panoramic radiography. Dentomaxillofac Radiol 44(5):1–7, 2015. https://doi.org/10.1259/dmfr.20140365.CrossRef Kallio-Pulkkinen S, Haapea M, Liukkonen E, Huumonen S, Tervonen O, Nieminen MT: Comparison between DICOM-calibrated and uncalibrated consumer grade and 6-MP displays under different lighting conditions in panoramic radiography. Dentomaxillofac Radiol 44(5):1–7, 2015. https://​doi.​org/​10.​1259/​dmfr.​20140365.CrossRef
6.
Zurück zum Zitat Melo CA, Santos MAL, Menezes LS, Santana FS, Melo MFB, Takeshita WM: Use of smartphones and tablets in radiographic evaluation: accuracy of caries detection on bitewing radiographs. Gen Dent 69(4):28–34, 2021.PubMed Melo CA, Santos MAL, Menezes LS, Santana FS, Melo MFB, Takeshita WM: Use of smartphones and tablets in radiographic evaluation: accuracy of caries detection on bitewing radiographs. Gen Dent 69(4):28–34, 2021.PubMed
9.
Zurück zum Zitat Odlum N, Spalla G, Van Assche N, Vandenberghe B, Jacobs R, Quirynen M: Preliminary display comparison for dental diagnostic applications. Medical imaging 2012: image perception, observer Performance, And Technology Assessment. In: Proceedings Of SPIE 8318:4–9, 2012. Odlum N, Spalla G, Van Assche N, Vandenberghe B, Jacobs R, Quirynen M: Preliminary display comparison for dental diagnostic applications. Medical imaging 2012: image perception, observer Performance, And Technology Assessment. In: Proceedings Of SPIE 8318:4–9, 2012.
10.
Zurück zum Zitat Fleiss JL, Levin B, Paik MC: Statistical methods for rates and proportions. New Jersey: John Wiley & Sons, 2003.CrossRef Fleiss JL, Levin B, Paik MC: Statistical methods for rates and proportions. New Jersey: John Wiley & Sons, 2003.CrossRef
11.
Zurück zum Zitat Deprá L de C, Vessoni Iwaki LC, Chicarelli M, Takeshita WM: Influence of image filters and variation in horizontal angle of incidence of x-ray beam in digital interproximal radiographs for diagnosis of secondary caries in esthetic restorations. J Contemp Dent Pract 16(10):805–812, 2015. https://doi.org/10.5005/jp-journals-10024-1761. Deprá L de C, Vessoni Iwaki LC, Chicarelli M, Takeshita WM: Influence of image filters and variation in horizontal angle of incidence of x-ray beam in digital interproximal radiographs for diagnosis of secondary caries in esthetic restorations. J Contemp Dent Pract 16(10):805–812, 2015. https://​doi.​org/​10.​5005/​jp-journals-10024-1761.
14.
Zurück zum Zitat Landis Jr, Koch GG: The measurement of observer agreement for categorical data. Biometrics 33:159–174, 1977. Landis Jr, Koch GG: The measurement of observer agreement for categorical data. Biometrics 33:159–174, 1977.
15.
Zurück zum Zitat Samei E, Badano A, Chakraborty D, Compton K, Cornelius C, Corrigan K, Flynn MJ, Hemminger B, Hangiandreou N, Johnson J, Moxley-Stevens DM, Pavlicek W, Roehrig H, Rutz L, Shepard J, Uzenoff RA, Wang J, Willis CE: Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Med Phys 32(4):1205–12052, 2005. https://doi.org/10.1118/1.1861159.CrossRefPubMed Samei E, Badano A, Chakraborty D, Compton K, Cornelius C, Corrigan K, Flynn MJ, Hemminger B, Hangiandreou N, Johnson J, Moxley-Stevens DM, Pavlicek W, Roehrig H, Rutz L, Shepard J, Uzenoff RA, Wang J, Willis CE: Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Med Phys 32(4):1205–12052, 2005. https://​doi.​org/​10.​1118/​1.​1861159.CrossRefPubMed
16.
Zurück zum Zitat Shah N, Bansai N, Logani A: Recent advances in imaging technologies in dentistry. World J Radiol 6(10):794, 2014.CrossRef Shah N, Bansai N, Logani A: Recent advances in imaging technologies in dentistry. World J Radiol 6(10):794, 2014.CrossRef
Metadaten
Titel
Diagnostic Accuracy of Caries and Periapical Lesions on a Monitor with and without DICOM-GSDF Calibration Under Different Ambient Light Conditions
verfasst von
Rangel Teles Freire
Agnaldo Rocha Prata-Júnior
John Nadson Andrade Pinho
Wilton Mitsunari Takeshita
Publikationsdatum
15.02.2022
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2022
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-022-00596-w

Neu im Fachgebiet Radiologie

Ringen um den richtigen Umgang mit Zufallsbefunden

Wenn 2026 in Deutschland das Lungenkrebsscreening mittels Low-Dose-Computertomografie (LDCT) eingeführt wird, wird es auch viele Zufallsbefunde ans Licht bringen. Das birgt Chancen und Risiken.

Bald 5% der Krebserkrankungen durch CT verursacht

Die jährlich rund 93 Millionen CTs in den USA könnten künftig zu über 100.000 zusätzlichen Krebserkrankungen führen, geht aus einer Modellrechnung hervor. Damit würde eine von 20 Krebserkrankungen auf die ionisierende Strahlung bei CT-Untersuchungen zurückgehen.

Röntgen-Thorax oder LDCT fürs Lungenscreening nach HNSCC?

Personen, die an einem Plattenepithelkarzinom im Kopf-Hals-Bereich erkrankt sind, haben ein erhöhtes Risiko für Metastasen oder zweite Primärmalignome der Lunge. Eine Studie hat untersucht, wie die radiologische Überwachung aussehen sollte.

Statine: Was der G-BA-Beschluss für Praxen bedeutet

Nach dem G-BA-Beschluss zur erweiterten Verordnungsfähigkeit von Lipidsenkern rechnet die DEGAM mit 200 bis 300 neuen Dauerpatienten pro Praxis. Im Interview erläutert Präsidiumsmitglied Erika Baum, wie Hausärztinnen und Hausärzte am besten vorgehen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.