Skip to main content
Erschienen in: Heart and Vessels 10/2020

29.04.2020 | Original Article

Diagnostic performance of coronary angiography utilizing intraprocedural 320-row computed tomography with minimal contrast medium

verfasst von: Misato Chimura, Tomohito Ohtani, Kensuke Yokoi, Tatsuya Shiraki, Themistoklis Katsimichas, Takashi Kitao, Masaki Awata, Isamu Mizote, Shungo Hikoso, Satoru Sumitsuji, Yasushi Sakata

Erschienen in: Heart and Vessels | Ausgabe 10/2020

Einloggen, um Zugang zu erhalten

Abstract

Recently developed coronary angiography with intraprocedural 320-row computed tomography can be performed in a catheterization laboratory (XACT) by injecting contrast medium from a place close to the coronary arteries, thereby requiring a minimal amount of contrast medium. However, its clinical application has not yet been established. This study aimed to evaluate the diagnostic accuracy of XACT angiography with a minimal volume of contrast medium in patients with suspected coronary artery disease (CAD). A total of 167 coronary segments were analyzed in 14 patients (9 males, median age 70 years) with suspected CAD by XACT angiography with 7.5 ml of contrast medium and invasive coronary angiography (ICA) with standard techniques. The segmental-based diagnostic accuracy of XACT angiography in detecting stenosis of ≥ 50% and ≥ 75% and visualized by ICA was good (sensitivity: 74% and 62%, specificity: 99% and 99%, positive predictive value: 93% and 80%, and negative predictive value: 97% and 97%, respectively). These results suggest that XACT angiography with a very low amount of contrast medium may have strong clinical utility for screening coronary arteries in patients with renal dysfunction or undergoing clinical procedures such as pacemaker implantation.
Literatur
1.
Zurück zum Zitat Yokoi K, Mizote I, Shiraki T, Ide S, Ohtani T, Hikoso S, Ikari Y, Sakata Y (2019) Mechanism of good back-up support with a deep-seated guiding catheter during percutaneous coronary intervention. Circ J 83:1763CrossRef Yokoi K, Mizote I, Shiraki T, Ide S, Ohtani T, Hikoso S, Ikari Y, Sakata Y (2019) Mechanism of good back-up support with a deep-seated guiding catheter during percutaneous coronary intervention. Circ J 83:1763CrossRef
2.
Zurück zum Zitat Nyman U, Bjork J, Aspelin P, Marenzi G (2008) Contrast medium dose-to-GFR ratio: a measure of systemic exposure to predict contrast-induced nephropathy after percutaneous coronary intervention. Acta Radiol 49:658–667CrossRef Nyman U, Bjork J, Aspelin P, Marenzi G (2008) Contrast medium dose-to-GFR ratio: a measure of systemic exposure to predict contrast-induced nephropathy after percutaneous coronary intervention. Acta Radiol 49:658–667CrossRef
3.
Zurück zum Zitat Wang K, Li HL, Bei WJ, Guo XS, Chen SQ, Islam SMS, Chen JY, Liu Y, Tan N (2017) Association of left ventricular ejection fraction with contrast-induced nephropathy and mortality following coronary angiography or intervention in patients with heart failure. Ther Clin Risk Manag 13:887–895CrossRef Wang K, Li HL, Bei WJ, Guo XS, Chen SQ, Islam SMS, Chen JY, Liu Y, Tan N (2017) Association of left ventricular ejection fraction with contrast-induced nephropathy and mortality following coronary angiography or intervention in patients with heart failure. Ther Clin Risk Manag 13:887–895CrossRef
4.
Zurück zum Zitat Kato E, Fujimoto S, Takamura K, Kawaguchi Y, Aoshima C, Hiki M, Kumamaru KK, Daida H (2018) Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography. Heart Vessels 33:462–469CrossRef Kato E, Fujimoto S, Takamura K, Kawaguchi Y, Aoshima C, Hiki M, Kumamaru KK, Daida H (2018) Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography. Heart Vessels 33:462–469CrossRef
5.
Zurück zum Zitat Harigaya H, Motoyama S, Sarai M, Inoue K, Hara T, Okamura M, Naruse H, Ishii J, Hishida H, Ozaki Y (2010) Prediction of the no-reflow phenomenon during percutaneous coronary intervention using coronary computed tomography angiography. Heart Vessels 26:363–369CrossRef Harigaya H, Motoyama S, Sarai M, Inoue K, Hara T, Okamura M, Naruse H, Ishii J, Hishida H, Ozaki Y (2010) Prediction of the no-reflow phenomenon during percutaneous coronary intervention using coronary computed tomography angiography. Heart Vessels 26:363–369CrossRef
6.
Zurück zum Zitat Yokoi K, Hara M, Ueda Y, Sumitsuji S, Awata M, Salah YK, Kabata D, Shintani A, Sakata Y (2017) Ideal guiding catheter position during bilaterally engaged percutaneous coronary intervention. Am J Cardiol 119:1518–1524CrossRef Yokoi K, Hara M, Ueda Y, Sumitsuji S, Awata M, Salah YK, Kabata D, Shintani A, Sakata Y (2017) Ideal guiding catheter position during bilaterally engaged percutaneous coronary intervention. Am J Cardiol 119:1518–1524CrossRef
7.
Zurück zum Zitat Tasai I, Lee T, Tsai W, Chen M, Wu M, Lee W, Ting H (2008) Contrast enhancement in cardiac MDCT: comparison of iodixanol 320 versus iohexol 350. AJR Am J Roentgenol 190:W47–W53CrossRef Tasai I, Lee T, Tsai W, Chen M, Wu M, Lee W, Ting H (2008) Contrast enhancement in cardiac MDCT: comparison of iodixanol 320 versus iohexol 350. AJR Am J Roentgenol 190:W47–W53CrossRef
8.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40CrossRef Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40CrossRef
9.
Zurück zum Zitat Raff GL, Abidov A, Achenbach S, Berman DS, Boxt LM, Budoff MJ, Cheng V, DeFrance T, Hellinger JC, Karlsberg RP (2009) SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography. J Cardiovasc Comput Tomogr 3:122–136CrossRef Raff GL, Abidov A, Achenbach S, Berman DS, Boxt LM, Budoff MJ, Cheng V, DeFrance T, Hellinger JC, Karlsberg RP (2009) SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography. J Cardiovasc Comput Tomogr 3:122–136CrossRef
10.
Zurück zum Zitat Cerci R, Vavere A, Miller J, Yoneyama K, Rochitte C, Dewey M, Niinuma H, Clouse M, Laham R, Bush D, Shapiro E, Lardo A, Cox C, Brinker J, Lima J, Arbab-Zadeh A (2013) Patterns of coronary arterial lesion calcification by a novel, cross-sectional CT angiographic assessment. Int J Cardiovasc Imaging 29:1619–1627CrossRef Cerci R, Vavere A, Miller J, Yoneyama K, Rochitte C, Dewey M, Niinuma H, Clouse M, Laham R, Bush D, Shapiro E, Lardo A, Cox C, Brinker J, Lima J, Arbab-Zadeh A (2013) Patterns of coronary arterial lesion calcification by a novel, cross-sectional CT angiographic assessment. Int J Cardiovasc Imaging 29:1619–1627CrossRef
11.
Zurück zum Zitat Mowatt G, Cook JA, Hillis GS, Walker S, Fraser C, Jia X, Waugh N (2008) 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94:1386–1393CrossRef Mowatt G, Cook JA, Hillis GS, Walker S, Fraser C, Jia X, Waugh N (2008) 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94:1386–1393CrossRef
12.
Zurück zum Zitat de Graaf FR, Schuijf JD, van Velzen JE, Kroft LJ, de Roos A, Reiber JH, Boersma E, Schalij MJ, Spano F, Jukema JW, van der Wall EE, Bax JJ (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease. Eur Heart J 31:1908–1915CrossRef de Graaf FR, Schuijf JD, van Velzen JE, Kroft LJ, de Roos A, Reiber JH, Boersma E, Schalij MJ, Spano F, Jukema JW, van der Wall EE, Bax JJ (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease. Eur Heart J 31:1908–1915CrossRef
13.
Zurück zum Zitat Uehara M, Takaoka H, Kobayashi Y, Funabashi N (2013) Diagnostic accuracy of 320-slice computed-tomography for detection of significant coronary artery stenosis in patients with various heart rates and heart rhythms compared with conventional coronary-angiography. Int J Cardiol 167:809–815CrossRef Uehara M, Takaoka H, Kobayashi Y, Funabashi N (2013) Diagnostic accuracy of 320-slice computed-tomography for detection of significant coronary artery stenosis in patients with various heart rates and heart rhythms compared with conventional coronary-angiography. Int J Cardiol 167:809–815CrossRef
14.
Zurück zum Zitat Rubinshtein R, Halon DA, Gaspar T, Jaffe R, Karkabi B, Flugelman MY, Kogan A, Shapira R, Peled N, Lewis BS (2007) Usefulness of 64-slice cardiac computed tomographic angiography for diagnosing acute coronary syndromes and predicting clinical outcome in emergency department patients with chest pain of uncertain origin. Circulation 115:1762–1768CrossRef Rubinshtein R, Halon DA, Gaspar T, Jaffe R, Karkabi B, Flugelman MY, Kogan A, Shapira R, Peled N, Lewis BS (2007) Usefulness of 64-slice cardiac computed tomographic angiography for diagnosing acute coronary syndromes and predicting clinical outcome in emergency department patients with chest pain of uncertain origin. Circulation 115:1762–1768CrossRef
15.
Zurück zum Zitat Hamon M, Biondi-Zoccai GG, Malagutti P, Agostoni P, Morello R, Valgimigli M, Hamon M (2006) Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography: a meta-analysis. J Am Coll Cardiol 48:1896–1910CrossRef Hamon M, Biondi-Zoccai GG, Malagutti P, Agostoni P, Morello R, Valgimigli M, Hamon M (2006) Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography: a meta-analysis. J Am Coll Cardiol 48:1896–1910CrossRef
16.
Zurück zum Zitat Li S, Ni Q, Wu H, Peng L, Dong R, Chen L, Liu J (2013) Diagnostic accuracy of 320-slice computed tomography angiography for detection of coronary artery stenosis: meta-analysis. Int J Cardiol 168:2699–2705CrossRef Li S, Ni Q, Wu H, Peng L, Dong R, Chen L, Liu J (2013) Diagnostic accuracy of 320-slice computed tomography angiography for detection of coronary artery stenosis: meta-analysis. Int J Cardiol 168:2699–2705CrossRef
17.
Zurück zum Zitat Tsai TT, Patel UD, Chang TI, Kennedy KF, Masoudi FA, Matheny ME, Kosiborod M, Amin AP, Messenger JC, Rumsfeld JS, Spertus JA (2014) Contemporary incidence, predictors, and outcomes of acute kidney injury in patients undergoing percutaneous coronary interventions: insights from the NCDR Cath-PCI registry. JACC Cardiovasc Interv 7:1–9CrossRef Tsai TT, Patel UD, Chang TI, Kennedy KF, Masoudi FA, Matheny ME, Kosiborod M, Amin AP, Messenger JC, Rumsfeld JS, Spertus JA (2014) Contemporary incidence, predictors, and outcomes of acute kidney injury in patients undergoing percutaneous coronary interventions: insights from the NCDR Cath-PCI registry. JACC Cardiovasc Interv 7:1–9CrossRef
18.
Zurück zum Zitat Aurelio A, Durante A (2014) Contrast-induced nephropathy in percutaneous coronary interventions: pathogenesis, risk factors, outcome, prevention and treatment. Cardiology 128:62–72CrossRef Aurelio A, Durante A (2014) Contrast-induced nephropathy in percutaneous coronary interventions: pathogenesis, risk factors, outcome, prevention and treatment. Cardiology 128:62–72CrossRef
19.
Zurück zum Zitat Parfrey P (2005) The clinical epidemiology of contrast-induced nephropathy. Cardiovasc Intervent Radiol 28:S3–S11CrossRef Parfrey P (2005) The clinical epidemiology of contrast-induced nephropathy. Cardiovasc Intervent Radiol 28:S3–S11CrossRef
20.
Zurück zum Zitat Rybicki F, Mather R, Kumamaru K, Brinker J, Chen M, Cox C, Matheson M, Dewey M, DiCarli M, Miller J, Geleijns J, George R, Paul N, Texter J, Vavere A, Yaw T, Lima J, Clouse M (2015) Comprehensive assessment of radiation dose estimates for the CORE320 Study. AJR Am J Roentgenol 204:W27–W36CrossRef Rybicki F, Mather R, Kumamaru K, Brinker J, Chen M, Cox C, Matheson M, Dewey M, DiCarli M, Miller J, Geleijns J, George R, Paul N, Texter J, Vavere A, Yaw T, Lima J, Clouse M (2015) Comprehensive assessment of radiation dose estimates for the CORE320 Study. AJR Am J Roentgenol 204:W27–W36CrossRef
21.
Zurück zum Zitat van der Bijl N, de Bruin PW, Geleijns J, Bax JJ, Schuijf JD, de Roos A, Kroft LJ (2010) Assessment of coronary artery calcium by using volumetric 320-row multi-detector computed tomography: comparison of 0.5 mm with 3.0 mm slice reconstructions. Int J Cardiovasc Imaging 26:473–482CrossRef van der Bijl N, de Bruin PW, Geleijns J, Bax JJ, Schuijf JD, de Roos A, Kroft LJ (2010) Assessment of coronary artery calcium by using volumetric 320-row multi-detector computed tomography: comparison of 0.5 mm with 3.0 mm slice reconstructions. Int J Cardiovasc Imaging 26:473–482CrossRef
22.
Zurück zum Zitat Szilveszter B, Celeng C, Maurovich-Horvat P (2016) Plaque assessment by coronary CT. Int J Cardiovasc Imaging 32:161–172CrossRef Szilveszter B, Celeng C, Maurovich-Horvat P (2016) Plaque assessment by coronary CT. Int J Cardiovasc Imaging 32:161–172CrossRef
23.
Zurück zum Zitat Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schonberg SO, Luchner A, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T (2013) MR-IMPACT II: magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur Heart J 34:775–781CrossRef Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schonberg SO, Luchner A, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T (2013) MR-IMPACT II: magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur Heart J 34:775–781CrossRef
24.
Zurück zum Zitat Ishida N, Sakuma H, Motoyasu M, Okinaka T, Isaka N, Nakano T, Takeda K (2003) Noninfarcted myocardium: correlation between dynamic first-pass contrast-enhanced myocardial MR imaging and quantitative coronary angiography. Radiology 229:209–216CrossRef Ishida N, Sakuma H, Motoyasu M, Okinaka T, Isaka N, Nakano T, Takeda K (2003) Noninfarcted myocardium: correlation between dynamic first-pass contrast-enhanced myocardial MR imaging and quantitative coronary angiography. Radiology 229:209–216CrossRef
25.
Zurück zum Zitat Bruder O, Schneider S, Nothnagel D, Dill T, Hombach V, Schulz-Menger J, Nagel E, Lombardi M, van Rossum AC, Wagner A, Schwitter J, Senges J, Sabin GV, Sechtem U, Mahrholdt H (2009) EuroCMR registry: results of the German pilot phase. J Am Coll Cardiol 54:1457–1466CrossRef Bruder O, Schneider S, Nothnagel D, Dill T, Hombach V, Schulz-Menger J, Nagel E, Lombardi M, van Rossum AC, Wagner A, Schwitter J, Senges J, Sabin GV, Sechtem U, Mahrholdt H (2009) EuroCMR registry: results of the German pilot phase. J Am Coll Cardiol 54:1457–1466CrossRef
26.
Zurück zum Zitat Morton G, Plein S, Nagel E (2010) Noninvasive coronary angiography using computed tomography versus magnetic resonance imaging. Ann Inter Med 152:827–828CrossRef Morton G, Plein S, Nagel E (2010) Noninvasive coronary angiography using computed tomography versus magnetic resonance imaging. Ann Inter Med 152:827–828CrossRef
Metadaten
Titel
Diagnostic performance of coronary angiography utilizing intraprocedural 320-row computed tomography with minimal contrast medium
verfasst von
Misato Chimura
Tomohito Ohtani
Kensuke Yokoi
Tatsuya Shiraki
Themistoklis Katsimichas
Takashi Kitao
Masaki Awata
Isamu Mizote
Shungo Hikoso
Satoru Sumitsuji
Yasushi Sakata
Publikationsdatum
29.04.2020
Verlag
Springer Japan
Erschienen in
Heart and Vessels / Ausgabe 10/2020
Print ISSN: 0910-8327
Elektronische ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-020-01610-3

Weitere Artikel der Ausgabe 10/2020

Heart and Vessels 10/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.