Skip to main content
main-content

01.12.2018 | Research | Ausgabe 1/2018 Open Access

Annals of Intensive Care 1/2018

Diaphragm function and weaning from mechanical ventilation: an ultrasound and phrenic nerve stimulation clinical study

Zeitschrift:
Annals of Intensive Care > Ausgabe 1/2018
Autoren:
Martin Dres, Ewan C. Goligher, Bruno-Pierre Dubé, Elise Morawiec, Laurence Dangers, Danielle Reuter, Julien Mayaux, Thomas Similowski, Alexandre Demoule
Wichtige Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1186/​s13613-018-0401-y) contains supplementary material, which is available to authorized users.

Abstract

Background

Diaphragm dysfunction is defined by a value of twitch tracheal pressure in response to magnetic phrenic stimulation (twitch pressure) amounting to less than 11 cmH2O. This study assessed whether this threshold or a lower one would predict accurately weaning failure from mechanical ventilation. Twitch pressure was compared to ultrasound measurement of diaphragm function.

Methods

In patients undergoing a first spontaneous breathing trial, diaphragm function was evaluated by twitch pressure and by diaphragm ultrasound (thickening fraction). Receiver operating characteristics curves were computed to determine the best thresholds predicting failure of spontaneous breathing trial.

Results

Seventy-six patients were evaluated, 48 (63%) succeeded and 28 (37%) failed the spontaneous breathing trial. The optimal thresholds of twitch pressure and thickening fraction to predict failure of the spontaneous breathing trial were, respectively, 7.2 cmH2O and 25.8%, respectively. The receiver operating characteristics curves were 0.80 (95% CI 0.70–0.89) for twitch pressure and 0.82 (95% CI 0.73–0.93) for thickening fraction. Both receiver operating characteristics curves were similar (p = 0.83). A twitch pressure value lower than 11 cmH2O (the traditional cutoff for diaphragm dysfunction) predicted failure of the spontaneous breathing trial with a sensitivity of 89% (95% CI 72–98%) and a specificity of 45% (95% CI 30–60%).

Conclusions

Failure of spontaneous breathing trial can be predicted with a lower value of twitch pressure than the value defining diaphragm dysfunction. Twitch pressure and thickening fraction had similar strong performance in the prediction of failure of the spontaneous breathing trial.
Zusatzmaterial
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 1/2018

Annals of Intensive Care 1/2018 Zur Ausgabe