Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2018

16.01.2017 | Knee

Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty

verfasst von: Hagen Fritzsche, Franziska Beyer, Anne Postler, Jörg Lützner

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of this study was the comparison of intraoperative kinematics, stability, and range of motion (ROM) between the native osteoarthritic knee and cruciate-substituting fixed-bearing total knee arthroplasty (TKA) using both an ultracongruent (UC) and a posterior-stabilized (PS) insert design in the same patient. We hypothesized less knee flexion and less antero-posterior stability in the UC TKA.

Methods

Intraoperative measurements of kinematics, stability, and ROM were performed in 40 patients before soft-tissue release and bone cuts, and after implantation of the final femoral and tibial implants with both a UC insert and a PS insert. All measurements were performed using a navigation system.

Results

Kinematics changed significantly from a constant posterior femoral rollback before surgery to a paradoxical anterior translation during initial knee flexion with both inserts, but less pronounced with the PS insert (p < 0.001). There was significantly more posterior femoral rollback with the PS insert compared to the UC insert (p < 0.01). Stability measurements demonstrated no differences at full extension and 30° of knee flexion but significantly increased antero-posterior translation in 60° and 90° of knee flexion with the UC insert compared to the PS insert (p < 0.001). ROM measurements demonstrated improvement of knee flexion from 118° at the beginning of the surgery to 123° with the UC insert and 128° with the PS insert (p < 0.001).

Conclusion

The use of a UC insert intraoperatively resulted in less antero-posterior stability and slightly less knee flexion compared to a PS insert. Surgeons should be aware of these differences when deciding for one of these options to substitute the posterior cruciate ligament (PCL). The impact of these findings on clinical outcome needs further investigation.

Level of evidence

II.
Literatur
1.
Zurück zum Zitat Arnout N, Vanlommel L, Vanlommel J et al (2015) Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs. Knee Surg Sports Traumatol Arthrosc 23:3343–3353CrossRefPubMed Arnout N, Vanlommel L, Vanlommel J et al (2015) Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs. Knee Surg Sports Traumatol Arthrosc 23:3343–3353CrossRefPubMed
2.
Zurück zum Zitat Banks S, Bellemans J, Nozaki H et al (2003) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138CrossRef Banks S, Bellemans J, Nozaki H et al (2003) Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 410:131–138CrossRef
3.
Zurück zum Zitat Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304CrossRefPubMed Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304CrossRefPubMed
4.
Zurück zum Zitat Belvedere C, Tamarri S, Notarangelo DP et al (2013) Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements. Knee Surg Sports Traumatol Arthrosc 21:2375–2383CrossRefPubMed Belvedere C, Tamarri S, Notarangelo DP et al (2013) Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements. Knee Surg Sports Traumatol Arthrosc 21:2375–2383CrossRefPubMed
5.
Zurück zum Zitat Bignozzi S, Zaffagnini S, Akkawi I et al (2014) Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences. Knee Surg Sports Traumatol Arthrosc 22:3113–3120CrossRefPubMed Bignozzi S, Zaffagnini S, Akkawi I et al (2014) Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences. Knee Surg Sports Traumatol Arthrosc 22:3113–3120CrossRefPubMed
6.
Zurück zum Zitat Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15:576–583CrossRefPubMed Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15:576–583CrossRefPubMed
7.
Zurück zum Zitat Hozack WJ, Rothman RH, Booth RE Jr, Balderston RA (1989) The patellar clunk syndrome. A complication of posterior stabilized total knee arthroplasty. Clin Orthop Relat Res 241:203–208 Hozack WJ, Rothman RH, Booth RE Jr, Balderston RA (1989) The patellar clunk syndrome. A complication of posterior stabilized total knee arthroplasty. Clin Orthop Relat Res 241:203–208
8.
Zurück zum Zitat Johal P, Williams A, Wragg P, Hunt D, Gedroyc W (2005) Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI. J Biomech 38:269–276CrossRefPubMed Johal P, Williams A, Wragg P, Hunt D, Gedroyc W (2005) Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI. J Biomech 38:269–276CrossRefPubMed
9.
Zurück zum Zitat Kim TW, Lee SM, Seong SC et al (2015) Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:3036–3043CrossRefPubMed Kim TW, Lee SM, Seong SC et al (2015) Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:3036–3043CrossRefPubMed
10.
Zurück zum Zitat Ko YB, Jang EC, Park SM et al (2015) No difference in clinical and radiologic outcomes after total knee arthroplasty with a new ultra-congruent mobile bearing system and rotating platform mobile bearing systems after minimum 5-year follow-up. J Arthroplasty 30:379–383CrossRefPubMed Ko YB, Jang EC, Park SM et al (2015) No difference in clinical and radiologic outcomes after total knee arthroplasty with a new ultra-congruent mobile bearing system and rotating platform mobile bearing systems after minimum 5-year follow-up. J Arthroplasty 30:379–383CrossRefPubMed
11.
Zurück zum Zitat Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRef Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRef
12.
Zurück zum Zitat Lee DC, Kim DH, Scott RD, Suthers K (1998) Intraoperative flexion against gravity as an indication of ultimate range of motion in individual cases after total knee arthroplasty. J Arthroplasty 13:500–503CrossRefPubMed Lee DC, Kim DH, Scott RD, Suthers K (1998) Intraoperative flexion against gravity as an indication of ultimate range of motion in individual cases after total knee arthroplasty. J Arthroplasty 13:500–503CrossRefPubMed
13.
Zurück zum Zitat Lützner J, Beyer F, Dexel J, Fritzsche H, Lützner C, Kirschner S (2016) No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty—a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-4331-7 (epub ahead of print) PubMed Lützner J, Beyer F, Dexel J, Fritzsche H, Lützner C, Kirschner S (2016) No difference in range of motion between ultracongruent and posterior stabilized design in total knee arthroplasty—a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-4331-7 (epub ahead of print) PubMed
14.
Zurück zum Zitat Lützner J, Firmbach FP, Lützner C, Dexel J, Kirschner S (2015) Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23:1638–1643CrossRefPubMed Lützner J, Firmbach FP, Lützner C, Dexel J, Kirschner S (2015) Similar stability and range of motion between cruciate-retaining and cruciate-substituting ultracongruent insert total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23:1638–1643CrossRefPubMed
15.
Zurück zum Zitat Machhindra MV, Kang JY, Kang YG, Chowdhry M, Kim TK (2015) Functional outcomes of a new mobile-bearing ultra-congruent TKA system: comparison with the posterior stabilized system. J Arthroplasty 30:2137–2142CrossRefPubMed Machhindra MV, Kang JY, Kang YG, Chowdhry M, Kim TK (2015) Functional outcomes of a new mobile-bearing ultra-congruent TKA system: comparison with the posterior stabilized system. J Arthroplasty 30:2137–2142CrossRefPubMed
16.
Zurück zum Zitat Massin P, Boyer P, Sabourin M (2012) Less femorotibial rotation and AP translation in deep-dished total knee arthroplasty. An intraoperative kinematic study using navigation. Knee Surg Sports Traumatol Arthrosc 20:1714–1719CrossRefPubMed Massin P, Boyer P, Sabourin M (2012) Less femorotibial rotation and AP translation in deep-dished total knee arthroplasty. An intraoperative kinematic study using navigation. Knee Surg Sports Traumatol Arthrosc 20:1714–1719CrossRefPubMed
17.
Zurück zum Zitat Matziolis G, Mehlhorn S, Schattat N et al (2012) How much of the PCL is really preserved during the tibial cut? Knee Surg Sports Traumatol Arthrosc 20:1083–1086CrossRefPubMed Matziolis G, Mehlhorn S, Schattat N et al (2012) How much of the PCL is really preserved during the tibial cut? Knee Surg Sports Traumatol Arthrosc 20:1083–1086CrossRefPubMed
18.
Zurück zum Zitat Mihalko WM, Lowell J, Higgs G, Kurtz S (2016) Total knee post-cam design variations and their effects on kinematics and wear patterns. Orthopedics 39:45–49CrossRef Mihalko WM, Lowell J, Higgs G, Kurtz S (2016) Total knee post-cam design variations and their effects on kinematics and wear patterns. Orthopedics 39:45–49CrossRef
19.
Zurück zum Zitat Parsley BS, Conditt MA, Bertolusso R, Noble PC (2006) Posterior cruciate ligament substitution is not essential for excellent postoperative outcomes in total knee arthroplasty. J Arthroplasty 21:127–131CrossRefPubMed Parsley BS, Conditt MA, Bertolusso R, Noble PC (2006) Posterior cruciate ligament substitution is not essential for excellent postoperative outcomes in total knee arthroplasty. J Arthroplasty 21:127–131CrossRefPubMed
20.
Zurück zum Zitat Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472:175–180CrossRefPubMed Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472:175–180CrossRefPubMed
21.
Zurück zum Zitat Uvehammer J (2001) Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl 72:1–52CrossRefPubMed Uvehammer J (2001) Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop Scand Suppl 72:1–52CrossRefPubMed
22.
Zurück zum Zitat Wajsfisz A, Biau D, Boisrenoult P, Beaufils P (2010) Comparative study of intraoperative knee flexion with three different TKR designs. Orthop Traumatol Surg Res 96:242–248CrossRefPubMed Wajsfisz A, Biau D, Boisrenoult P, Beaufils P (2010) Comparative study of intraoperative knee flexion with three different TKR designs. Orthop Traumatol Surg Res 96:242–248CrossRefPubMed
Metadaten
Titel
Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty
verfasst von
Hagen Fritzsche
Franziska Beyer
Anne Postler
Jörg Lützner
Publikationsdatum
16.01.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 5/2018
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-017-4427-8

Weitere Artikel der Ausgabe 5/2018

Knee Surgery, Sports Traumatology, Arthroscopy 5/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.