Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

verfasst von: Hao Tang, Dejin Yang, Shengjie Guo, Jing Tang, Jian Liu, Dacheng Wang, Yixin Zhou

Erschienen in: Skeletal Radiology | Ausgabe 11/2016

Einloggen, um Zugang zu erhalten

Abstract

Objectives

For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components.

Materials and methods

We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria.

Results

For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT.

Conclusions

By minimizing metal artifacts in the bone–implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons.

Level of evidence

Level II, diagnostic cohort study.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Collier JP, Mayor MB, Chae JC, Surprenant VA, Surprenant HP, Dauphinais LA. Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. Clin Orthop Relat Res. 1988;235:173–80.PubMed Collier JP, Mayor MB, Chae JC, Surprenant VA, Surprenant HP, Dauphinais LA. Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. Clin Orthop Relat Res. 1988;235:173–80.PubMed
2.
Zurück zum Zitat Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg (Br). 1987;69(1):45–55. Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg (Br). 1987;69(1):45–55.
3.
Zurück zum Zitat Temmerman OP, Raijmakers PG, Berkhof J, Hoekstra OS, Teule GJ, Heyligers IC. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. J Bone Joint Surg (Br). 2005;87(6):781–5.CrossRef Temmerman OP, Raijmakers PG, Berkhof J, Hoekstra OS, Teule GJ, Heyligers IC. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. J Bone Joint Surg (Br). 2005;87(6):781–5.CrossRef
4.
Zurück zum Zitat Patel AR, Sweeney P, Ochenjele G, Wixson R, Stulberg SD, Puri LM. Radiographically silent loosening of the acetabular component in hip arthroplasty. Am J Orthop (Belle Mead NJ). 2015;44(9):406–10. Patel AR, Sweeney P, Ochenjele G, Wixson R, Stulberg SD, Puri LM. Radiographically silent loosening of the acetabular component in hip arthroplasty. Am J Orthop (Belle Mead NJ). 2015;44(9):406–10.
5.
Zurück zum Zitat Tonkopi E, Ross AA. Assessment of effective dose from cone beam Ct imaging in SPECT/CT examination in comparison with other modalities. Radiat Prot Dosimetry. 2016. doi:10.1093/rpd/ncv534. Tonkopi E, Ross AA. Assessment of effective dose from cone beam Ct imaging in SPECT/CT examination in comparison with other modalities. Radiat Prot Dosimetry. 2016. doi:10.​1093/​rpd/​ncv534.
6.
Zurück zum Zitat Koyama S, Aoyama T, Oda N, Yamauchi-Kawaura C. Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom. Med Phys. 2010;37(8):4298–306.CrossRefPubMed Koyama S, Aoyama T, Oda N, Yamauchi-Kawaura C. Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom. Med Phys. 2010;37(8):4298–306.CrossRefPubMed
7.
Zurück zum Zitat Zotti MG, Campbell DG, Woodman R. Detection of periprosthetic osteolysis around total knee arthroplasties an in vitro study. J Arthroplasty. 2012;27(2):317–22.CrossRefPubMed Zotti MG, Campbell DG, Woodman R. Detection of periprosthetic osteolysis around total knee arthroplasties an in vitro study. J Arthroplasty. 2012;27(2):317–22.CrossRefPubMed
8.
Zurück zum Zitat Gothlin JH, Geijer M. The utility of digital linear tomosynthesis imaging of total hip joint arthroplasty with suspicion of loosening: a prospective study in 40 patients. Biomed Res Int. 2013;2013:594631.CrossRefPubMedPubMedCentral Gothlin JH, Geijer M. The utility of digital linear tomosynthesis imaging of total hip joint arthroplasty with suspicion of loosening: a prospective study in 40 patients. Biomed Res Int. 2013;2013:594631.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Xia W, Yin XR, Wu JT, Wu HT. Comparative study of DTS and CT in the skeletal trauma imaging diagnosis evaluation and radiation dose. Eur J Radiol. 2013;82(2):e76–80.CrossRefPubMed Xia W, Yin XR, Wu JT, Wu HT. Comparative study of DTS and CT in the skeletal trauma imaging diagnosis evaluation and radiation dose. Eur J Radiol. 2013;82(2):e76–80.CrossRefPubMed
10.
Zurück zum Zitat Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN. Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am. 2009;91(8):1882–9.CrossRefPubMed Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN. Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am. 2009;91(8):1882–9.CrossRefPubMed
11.
Zurück zum Zitat Haruhiko Machida TY, Mori T. Optimizing parameters for flat-panel detector digital tomosynthesis. RadioGraphics. 2010;30:549–62.CrossRefPubMed Haruhiko Machida TY, Mori T. Optimizing parameters for flat-panel detector digital tomosynthesis. RadioGraphics. 2010;30:549–62.CrossRefPubMed
12.
Zurück zum Zitat Sakimoto T, Nishino K. Metal artifact reduction in tomosynthesis by metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. SPIE Med Imag; 2013: Int Soc Optics Photo. 2013; 86685M-86685M-86688. Sakimoto T, Nishino K. Metal artifact reduction in tomosynthesis by metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. SPIE Med Imag; 2013: Int Soc Optics Photo. 2013; 86685M-86685M-86688.
13.
Zurück zum Zitat Minoda Y, Yoshida T, Sugimoto K, Baba S, Ikebuchi M, Nakamura H. Detection of small periprosthetic bone defects after total knee arthroplasty. J Arthroplasty. 2014;29(12):2280–4.CrossRefPubMed Minoda Y, Yoshida T, Sugimoto K, Baba S, Ikebuchi M, Nakamura H. Detection of small periprosthetic bone defects after total knee arthroplasty. J Arthroplasty. 2014;29(12):2280–4.CrossRefPubMed
14.
Zurück zum Zitat Lakstein D, Backstein D, Safir O, Kosashvili Y, Gross AE. Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res. 2010;468(5):1310–5.CrossRefPubMed Lakstein D, Backstein D, Safir O, Kosashvili Y, Gross AE. Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res. 2010;468(5):1310–5.CrossRefPubMed
15.
Zurück zum Zitat Spinarelli A, Patella V, Conserva V, Vicenti G, Pesce V, Patella S. Hip painful prosthesis: surgical view. Clin Cases Miner Bone Metab. 2011;8(2):14–8.PubMedPubMedCentral Spinarelli A, Patella V, Conserva V, Vicenti G, Pesce V, Patella S. Hip painful prosthesis: surgical view. Clin Cases Miner Bone Metab. 2011;8(2):14–8.PubMedPubMedCentral
16.
Zurück zum Zitat Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol. 2010;194(4):881–9.CrossRefPubMed Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol. 2010;194(4):881–9.CrossRefPubMed
17.
Zurück zum Zitat Meding JB, Ritter MA, Keating EM, Faris PM. Clinical and radiographic evaluation of long-stem femoral components following revision total hip arthroplasty. J Arthroplasty. 1994;9(4):399–408.CrossRefPubMed Meding JB, Ritter MA, Keating EM, Faris PM. Clinical and radiographic evaluation of long-stem femoral components following revision total hip arthroplasty. J Arthroplasty. 1994;9(4):399–408.CrossRefPubMed
18.
Zurück zum Zitat Valle AG, Zoppi A, Peterson MG, Salvati EA. Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Joint Surg Am. 2004;86-A(9):1998–2004.PubMed Valle AG, Zoppi A, Peterson MG, Salvati EA. Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Joint Surg Am. 2004;86-A(9):1998–2004.PubMed
19.
Zurück zum Zitat Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990;257:107–28.PubMed Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990;257:107–28.PubMed
20.
Zurück zum Zitat Barrack RL, Tanzer M, Kattapuram SV, Harris WH. The value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components. Skeletal Radiol. 1994;23(1):37–41.CrossRefPubMed Barrack RL, Tanzer M, Kattapuram SV, Harris WH. The value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components. Skeletal Radiol. 1994;23(1):37–41.CrossRefPubMed
21.
Zurück zum Zitat Thomas A, Gruen GMM. Modes of failure of cemented femoral stem. Clin Orthop Relat Res. 1979;141:17–27. Thomas A, Gruen GMM. Modes of failure of cemented femoral stem. Clin Orthop Relat Res. 1979;141:17–27.
22.
Zurück zum Zitat Jesse G, Delee JC. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthopoed Relat Research. 1976;121:20–32. Jesse G, Delee JC. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthopoed Relat Research. 1976;121:20–32.
23.
Zurück zum Zitat Park KS, Yoon TR, Song EK, Lee KB. Results of isolated femoral component revision with well-fixed acetabular implant retention. J Arthroplasty. 2010;25(8):1188–95.CrossRefPubMed Park KS, Yoon TR, Song EK, Lee KB. Results of isolated femoral component revision with well-fixed acetabular implant retention. J Arthroplasty. 2010;25(8):1188–95.CrossRefPubMed
24.
Zurück zum Zitat Cho HJ, Han SB, Park JH, Park SW. An analysis of stably fixed femoral components retained during revision total hip arthroplasty. J Arthroplasty. 2011;26(8):1239–44.CrossRefPubMed Cho HJ, Han SB, Park JH, Park SW. An analysis of stably fixed femoral components retained during revision total hip arthroplasty. J Arthroplasty. 2011;26(8):1239–44.CrossRefPubMed
25.
Zurück zum Zitat Whiteside LA, White SE, Engh CA, Head W. Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. J Arthroplasty. 1993;8(2):147–55.CrossRefPubMed Whiteside LA, White SE, Engh CA, Head W. Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. J Arthroplasty. 1993;8(2):147–55.CrossRefPubMed
26.
Zurück zum Zitat Machida H, Yuhara T, Sabol JM, Tamura M, Shimada Y, Ueno E. Postoperative follow-up of olecranon fracture by digital tomosynthesis radiography. Jpn J Radiol. 2011;29(8):583–6.CrossRefPubMed Machida H, Yuhara T, Sabol JM, Tamura M, Shimada Y, Ueno E. Postoperative follow-up of olecranon fracture by digital tomosynthesis radiography. Jpn J Radiol. 2011;29(8):583–6.CrossRefPubMed
27.
Zurück zum Zitat Kim W, Oravec D, Nekkanty S, Yerramshetty J, Sander EA, Divine GW, et al. Digital tomosynthesis (DTS) for quantitative assessment of trabecular microstructure in human vertebral bone. Med Eng Phys. 2014. Kim W, Oravec D, Nekkanty S, Yerramshetty J, Sander EA, Divine GW, et al. Digital tomosynthesis (DTS) for quantitative assessment of trabecular microstructure in human vertebral bone. Med Eng Phys. 2014.
28.
Zurück zum Zitat Krismer M, Klar M, Klestil T, Frischhut B. Aseptic loosening of straight- and curved-stem Muller femoral prostheses. Arch Orthop Trauma Surg. 1991;110(4):190–4.CrossRefPubMed Krismer M, Klar M, Klestil T, Frischhut B. Aseptic loosening of straight- and curved-stem Muller femoral prostheses. Arch Orthop Trauma Surg. 1991;110(4):190–4.CrossRefPubMed
29.
Zurück zum Zitat Moore MS, McAuley JP, Young AM, Engh Sr CA. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–83.CrossRefPubMed Moore MS, McAuley JP, Young AM, Engh Sr CA. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–83.CrossRefPubMed
30.
Zurück zum Zitat Gomi T, Hirano H. Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty. J Digit Imaging. 2008;21(3):312–22.CrossRefPubMed Gomi T, Hirano H. Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty. J Digit Imaging. 2008;21(3):312–22.CrossRefPubMed
31.
Zurück zum Zitat Solomon LB, Stamenkov RB, MacDonald AJ, Yaikwavong N, Neale SD, Moss MJ, et al. Imaging periprosthetic osteolysis around total knee arthroplasties using a human cadaver model. J Arthroplasty. 2012;27(6):1069–74.CrossRefPubMed Solomon LB, Stamenkov RB, MacDonald AJ, Yaikwavong N, Neale SD, Moss MJ, et al. Imaging periprosthetic osteolysis around total knee arthroplasties using a human cadaver model. J Arthroplasty. 2012;27(6):1069–74.CrossRefPubMed
32.
Zurück zum Zitat Morsbach F, Bickelhaupt S, Wanner GA, Krauss A, Schmidt B, Alkadhi H. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions. Radiology. 2013;268(1):237–44.CrossRefPubMed Morsbach F, Bickelhaupt S, Wanner GA, Krauss A, Schmidt B, Alkadhi H. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions. Radiology. 2013;268(1):237–44.CrossRefPubMed
33.
Zurück zum Zitat Abele JT, Swami VG, Russell G, Masson EC, Flemming JP. The accuracy of single photon emission computed tomography/computed tomography arthrography in evaluating aseptic loosening of hip and knee prostheses. J Arthroplasty. 2015;30(9):1647–51.CrossRefPubMed Abele JT, Swami VG, Russell G, Masson EC, Flemming JP. The accuracy of single photon emission computed tomography/computed tomography arthrography in evaluating aseptic loosening of hip and knee prostheses. J Arthroplasty. 2015;30(9):1647–51.CrossRefPubMed
Metadaten
Titel
Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients
verfasst von
Hao Tang
Dejin Yang
Shengjie Guo
Jing Tang
Jian Liu
Dacheng Wang
Yixin Zhou
Publikationsdatum
02.09.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 11/2016
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-016-2466-8

Weitere Artikel der Ausgabe 11/2016

Skeletal Radiology 11/2016 Zur Ausgabe

Browser's Notes

Browser’s Notes

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.