Skip to main content
main-content

01.12.2014 | Research Article | Ausgabe 6/2014

Magnetic Resonance Materials in Physics, Biology and Medicine 6/2014

Direct 17O MRI with partial volume correction: first experiences in a glioblastoma patient

Zeitschrift:
Magnetic Resonance Materials in Physics, Biology and Medicine > Ausgabe 6/2014
Autoren:
Stefan H. Hoffmann, Alexander Radbruch, Michael Bock, Wolfhard Semmler, Armin M. Nagel

Abstract

Object

In tumor cells the energy production is shifted from aerobic to anaerobic metabolization of glucose, which makes the cerebral metabolic rate of oxygen consumption (CMRO2) a diagnostic parameter for tissue viability. Direct oxygen-17 (17O) MRI during inhalation of 17O gas allows for a non-invasive determination of the CMRO2. However, the low spatial resolution and the fast transverse relaxation of 17O lead to partial volume effects that severely bias the quantification of signal intensities. The aim of this work was to determine the CMRO2 in a tumor patient by 17O MRI in combination with a partial volume correction (PVC) scheme.

Materials and methods

Direct 17O MRI was performed in a glioblastoma patient (F, 51 years) prior to surgery at 7 T. The ‘geometric transfer matrix’ algorithm for volume of interest based PVC was adapted to 17O MRI to recover the true signal intensities. We determined the CMRO2 values of gray matter (GM), white matter (WM), cerebrospinal fluid (CSF) and the tumor areas of the contrast enhancing rim (CE), the necrotic center (NE), and the perifocal edema (PE) using a three-phase metabolic model.

Results

Large differences in the signal increase during 17O2 inhalation were obtained ranging from less than 2 % in the tumor center up to more than 20 % in GM areas. After PVC of the signal time curves, we determined CMRO2 values of 0.67 ± 0.08 μmol/g/min (WM), 3.57 ± 0.67 μmol/g/min (GM), 0.35 ± 0.09 μmol/g/min (CE), and 0.42 ± 0.05 μmol/g/min (PE). In CSF and NE no oxygen uptake (i.e. CMRO2 = 0) was determined from the corrected signals, well in accordance with the underlying physiology in these regions.

Conclusion

The results show that PVC has a strong effect on the resulting CMRO2 values obtained by 17O MRI. We found substantial differences—especially in GM tissue—between corrected and non-corrected CMRO2 values. Additionally, we demonstrated the feasibility of CMRO2 assessment in a glioblastoma patient by 17O MRI.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 6/2014

Magnetic Resonance Materials in Physics, Biology and Medicine 6/2014 Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Radiologie

Meistgelesene Bücher aus der Radiologie

2016 | Buch

Medizinische Fremdkörper in der Bildgebung

Thorax, Abdomen, Gefäße und Kinder

Dieses einzigartige Buch enthält ca. 1.600 hochwertige radiologische Abbildungen und Fotos iatrogen eingebrachter Fremdmaterialien im Röntgenbild und CT.

Herausgeber:
Dr. med. Daniela Kildal

2011 | Buch

Atlas Klinische Neuroradiologie des Gehirns

Radiologie lebt von Bildern! Der vorliegende Atlas trägt dieser Tatsache Rechnung. Sie finden zu jedem Krankheitsbild des Gehirns Referenzbilder zum Abgleichen mit eigenen Befunden.

Autoren:
Priv.-Doz. Dr. med. Jennifer Linn, Prof. Dr. med. Martin Wiesmann, Prof. Dr. med. Hartmut Brückmann

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Radiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise