Skip to main content
Erschienen in: Heart and Vessels 4/2013

01.07.2013 | Case Report

Dislodged and mechanically distorted stent stuck within a previously implanted drug-eluting stent

verfasst von: Hiroaki Watabe, Akira Sato, Tomoya Hoshi, Kenichi Obara, Ryo Kawamura, Kazutaka Aonuma

Erschienen in: Heart and Vessels | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Coronary stent loss during percutaneous coronary intervention is rare and is often associated with significant morbidity. Several retrieval techniques, overlying stent deployment and crushing, and surgical removal can be used to deal with a stent lost in the coronary system. We successfully treated a dislodged and mechanically distorted coil stent stuck within a previously implanted drug-eluting stent (DES) by stent-crush technique. This case might provide insight into the mechanisms responsible for the longitudinal fragility of cobalt alloy and coil-structure stents and stent fracture of DES. In the DES era, careful attention should be paid to such complications when attempting to deliver a stent to a distal vessel through a pre-existing DES.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Kammler J, Leisch F, Kerschner K, Kypta A, Steinwender C, Kratochwill H, Lukas T, Hofmann R (2006) Long-term follow-up in patients with lost coronary stents during interventional procedures. Am J Cardiol 98:367–369PubMedCrossRef Kammler J, Leisch F, Kerschner K, Kypta A, Steinwender C, Kratochwill H, Lukas T, Hofmann R (2006) Long-term follow-up in patients with lost coronary stents during interventional procedures. Am J Cardiol 98:367–369PubMedCrossRef
2.
Zurück zum Zitat Brilakis ES, Best PJ, Elesber A, Barsness GW, Lennon RJ, Holmes DR Jr, Rihal CS, Garratt KN (2005) Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience. Catheter Cardiovasc Interv 66:333–340PubMedCrossRef Brilakis ES, Best PJ, Elesber A, Barsness GW, Lennon RJ, Holmes DR Jr, Rihal CS, Garratt KN (2005) Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience. Catheter Cardiovasc Interv 66:333–340PubMedCrossRef
3.
Zurück zum Zitat Eggebrecht H, Haude M, von Birgelen C, Oldenburg O, Baumgart D, Herrmann J, Welge D, Bartel T, Dagres N, Erbel R (2000) Nonsurgical retrieval of embolized coronary stents. Catheter Cardiovasc Interv 51:432–440PubMedCrossRef Eggebrecht H, Haude M, von Birgelen C, Oldenburg O, Baumgart D, Herrmann J, Welge D, Bartel T, Dagres N, Erbel R (2000) Nonsurgical retrieval of embolized coronary stents. Catheter Cardiovasc Interv 51:432–440PubMedCrossRef
4.
Zurück zum Zitat Ormiston JA, Webber B, Webster MW (2011) Stent longitudinal integrity bench insights into a clinical problem. JACC Cardiovasc Interv 4:1310–1317PubMedCrossRef Ormiston JA, Webber B, Webster MW (2011) Stent longitudinal integrity bench insights into a clinical problem. JACC Cardiovasc Interv 4:1310–1317PubMedCrossRef
5.
Zurück zum Zitat Pitney M, Pitney K, Jepson N, Friedman D, Nguyen-Dang T, Matthews J, Giles R, Taylor D (2011) Major stent deformation/pseudofracture of 7 Crown Endeavor/Micro Driver stent platform: incidence and causative factors. EuroIntervention 7(2):256–262PubMedCrossRef Pitney M, Pitney K, Jepson N, Friedman D, Nguyen-Dang T, Matthews J, Giles R, Taylor D (2011) Major stent deformation/pseudofracture of 7 Crown Endeavor/Micro Driver stent platform: incidence and causative factors. EuroIntervention 7(2):256–262PubMedCrossRef
6.
Zurück zum Zitat Tanaka N, Pijls NH, Koolen JJ, Botman KJ, Michels HR, Brueren BR, Peels K, Shindo N, Yamashita J, Yamashina A (2011) Assessment of optimum stent deployment by stent boost imaging: comparison with intravascular ultrasound. Heart Vessels. doi:10.1007/s00380-011-0202-9 Tanaka N, Pijls NH, Koolen JJ, Botman KJ, Michels HR, Brueren BR, Peels K, Shindo N, Yamashita J, Yamashina A (2011) Assessment of optimum stent deployment by stent boost imaging: comparison with intravascular ultrasound. Heart Vessels. doi:10.​1007/​s00380-011-0202-9
7.
Zurück zum Zitat Buja P, Lanzellotti D, Isabella G, Napodano M, Panfili M, Favaretto E, Iliceto S, Tarantini G (2011) Comparison between sirolimus- and paclitaxel-eluting stents for the treatment of older patients affected by coronary artery disease: results from a single-center allcomers registry. Heart Vessels. doi:10.1007/s00380-011-0194-5 PubMed Buja P, Lanzellotti D, Isabella G, Napodano M, Panfili M, Favaretto E, Iliceto S, Tarantini G (2011) Comparison between sirolimus- and paclitaxel-eluting stents for the treatment of older patients affected by coronary artery disease: results from a single-center allcomers registry. Heart Vessels. doi:10.​1007/​s00380-011-0194-5 PubMed
Metadaten
Titel
Dislodged and mechanically distorted stent stuck within a previously implanted drug-eluting stent
verfasst von
Hiroaki Watabe
Akira Sato
Tomoya Hoshi
Kenichi Obara
Ryo Kawamura
Kazutaka Aonuma
Publikationsdatum
01.07.2013
Verlag
Springer Japan
Erschienen in
Heart and Vessels / Ausgabe 4/2013
Print ISSN: 0910-8327
Elektronische ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-012-0290-1

Weitere Artikel der Ausgabe 4/2013

Heart and Vessels 4/2013 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.