Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 1/2012

01.01.2012 | Original Article

Distal plate placement for distal radius fractures limits wrist motion

verfasst von: Shingo Komura, Hiroyuki Tanahashi, Yoshihisa Yamada, Tatsuo Yokoi, Hidehiko Nonomura, Yasushi Suzuki

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To investigate the influence of distal plate placement for distal radius fractures on risk of flexor tendon complications and wrist motion by performing hardware removal.

Materials and methods

Fourteen patients treated with a Synthes 2.4 mm juxta-articular LCP Distal Radius Plate underwent hardware removal at ≥6 months postoperatively when improvement of range of motion and grip strength were obtained. Location of plate placement, condition of the flexor tendons, range of motion, grip strength, and postoperative complications were evaluated.

Results

The average minimum distance between the plate and joint line was 2.0 mm (range, 0.4–4.5 mm), and average distance at the base of the styloid process was 7.5 mm (range, 4.2–9.6 mm). All plates were located distal to the watershed line. Pathological conditions of flexor tendons were observed in 3 patients—adhesion of flexor pollicis longus in 1 and flexor tendon synovitis in 2—however, there were no cases of abrasion or rupture. The average active wrist flexion improved from 53.6° to 61.1°, extension from 67.5° to 70.7°, and the flexion–extension arc of motion improved from 121.1° to 131.8°. The flexion and flexion–extension arc were significantly improved (P = 0.0003 and P = 0.007, respectively). The average grip strength increased from 18.5 to 19.4 kg (not significant). Temporary median nerve disturbance was observed in 1 patient as a postoperative complication.

Conclusions

Removal of juxta-articular LCP Distal Radius Plate improved wrist motion. Plates located distal to the watershed line may increase the risk of flexor tendon complications and limit wrist motion.
Literatur
1.
Zurück zum Zitat Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322PubMedCrossRef Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322PubMedCrossRef
2.
Zurück zum Zitat Downing ND, Karantana A (2008) A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 90:1271–1275PubMedCrossRef Downing ND, Karantana A (2008) A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 90:1271–1275PubMedCrossRef
3.
Zurück zum Zitat Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M (2010) Unstable distal radius fractures in the elderly patient-volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 68:992–998PubMed Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M (2010) Unstable distal radius fractures in the elderly patient-volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 68:992–998PubMed
4.
Zurück zum Zitat Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67PubMed Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67PubMed
5.
Zurück zum Zitat Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31:359–365PubMedCrossRef Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31:359–365PubMedCrossRef
6.
Zurück zum Zitat Bhattacharyya T, Wadgaonkar AD (2008) Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases. J Bone Joint Surg Am 90:401–403PubMedCrossRef Bhattacharyya T, Wadgaonkar AD (2008) Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases. J Bone Joint Surg Am 90:401–403PubMedCrossRef
7.
Zurück zum Zitat Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 34:471–474CrossRef Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 34:471–474CrossRef
8.
Zurück zum Zitat Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33:164–167PubMedCrossRef Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33:164–167PubMedCrossRef
9.
Zurück zum Zitat Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714–719PubMed Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714–719PubMed
10.
Zurück zum Zitat Cognet JM, Dujardin C, Popescu A, Gouzou S, Simon P (2005) Rupture of the flexor tendons on an anterior plate for distal radial fracture: four cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 91:476–481PubMedCrossRef Cognet JM, Dujardin C, Popescu A, Gouzou S, Simon P (2005) Rupture of the flexor tendons on an anterior plate for distal radial fracture: four cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 91:476–481PubMedCrossRef
11.
Zurück zum Zitat Buzzell JE, Weikert DR, Watson JT, Lee DH (2008) Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 33:1144–1152PubMedCrossRef Buzzell JE, Weikert DR, Watson JT, Lee DH (2008) Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 33:1144–1152PubMedCrossRef
12.
Zurück zum Zitat Müller ME (1987) Distal radius. In: Müller ME, Nazarian S, Koch P, Schatzker J (eds) AO classification of fractures. etc. Springer, Berlin, pp 106–115 Müller ME (1987) Distal radius. In: Müller ME, Nazarian S, Koch P, Schatzker J (eds) AO classification of fractures. etc. Springer, Berlin, pp 106–115
13.
Zurück zum Zitat Jacques G (1981) Atlas of human limb joints. Springer, Berlin, p 182 Jacques G (1981) Atlas of human limb joints. Springer, Berlin, p 182
14.
Zurück zum Zitat Park JH, Hagopian J, Ilyas AM (2010) Variable-angle locking screw volar plating of distal radius fractures. Hand Clin 26:373–380PubMedCrossRef Park JH, Hagopian J, Ilyas AM (2010) Variable-angle locking screw volar plating of distal radius fractures. Hand Clin 26:373–380PubMedCrossRef
Metadaten
Titel
Distal plate placement for distal radius fractures limits wrist motion
verfasst von
Shingo Komura
Hiroyuki Tanahashi
Yoshihisa Yamada
Tatsuo Yokoi
Hidehiko Nonomura
Yasushi Suzuki
Publikationsdatum
01.01.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 1/2012
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-011-0809-7

Weitere Artikel der Ausgabe 1/2012

European Journal of Orthopaedic Surgery & Traumatology 1/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.