Skip to main content
Erschienen in:

05.01.2022 | Original Paper

Distribution of anterior chamber angle measurements in South African young adults: an optical coherence tomography study

verfasst von: Nishanee Rampersad, Rekha Hansraj

Erschienen in: International Ophthalmology | Ausgabe 6/2022

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Assessment of anterior chamber angle (ACA) variables is important to screen, diagnose and monitor ocular anomalies. Even though data on ACA variables, such as angle-opening distance taken at 500 µm (AOD500) and trabecular-iris angle (TIA), are available in the literature, limited information is available about these variables in African sub-populations. The purpose of this study is to describe the distribution of ACA measurements (AOD500 and TIA) in a South African young adult population.

Methods

In this cross-sectional study, 700 young adults were recruited from a university student population using two-stage random sampling. The Optovue iVue 100 optical coherence tomographer was used to measure the ACA variables. The distribution of the AOD500 and TIA measurements was analysed using descriptive and inferential statistics. Data from only the right eyes were analysed because the ACA measurements in the two eyes showed high levels of interocular symmetry.

Results

The measurements for the nasal and temporal ACAs were asymmetrically distributed (p < 0.001). The median AOD500 measurements in the nasal and temporal angles were 539 µm and 542 µm, respectively. The median TIA measurements were similar (~ 36°) in the two horizontal angles. The temporal ACA measurements were slightly higher than the nasal ACA measurements. Females had higher median ACA measurements than males (p ≥ 0.029).

Conclusion

The ACA measurements in South African young adults resemble non-Gaussian curves. The ACA measurements are different from that reported in other sub-populations worldwide and most participants had ACA measurements associated with non-occludable ACAs.
Literatur
1.
Zurück zum Zitat Ackland P, Resnikoff S, Bourne RRA (2017) World blindness and visual impairment: despite many successes, the problem is growing. Community Eye Health 30:71–73PubMed Ackland P, Resnikoff S, Bourne RRA (2017) World blindness and visual impairment: despite many successes, the problem is growing. Community Eye Health 30:71–73PubMed
2.
Zurück zum Zitat Amerasinghe N, Foster PJ, Wong TY, Htoon HM, He M, Shen SY, Aung HT, Saw SM, Aung T (2009) Variation of angle parameters in Asians: anterior segment optical coherence tomography study in a population of Singapore Malays. Invest Ophthalmol Vis Sci 50:2626–2631PubMedCrossRef Amerasinghe N, Foster PJ, Wong TY, Htoon HM, He M, Shen SY, Aung HT, Saw SM, Aung T (2009) Variation of angle parameters in Asians: anterior segment optical coherence tomography study in a population of Singapore Malays. Invest Ophthalmol Vis Sci 50:2626–2631PubMedCrossRef
3.
Zurück zum Zitat Bland JM (2015) The normal distribution. An introduction to medical statistics. Oxford Univeristy Press, New York, pp 85–100 Bland JM (2015) The normal distribution. An introduction to medical statistics. Oxford Univeristy Press, New York, pp 85–100
4.
Zurück zum Zitat Campa C, Pierro L, Bettin P, Bandello F (2011) Anterior chamber angle assessment techniques. In: Rumelt S (ed) Glaucoma—basic and clinical concepts. INTECH Open access Publisher, Crotia, pp 371–390 Campa C, Pierro L, Bettin P, Bandello F (2011) Anterior chamber angle assessment techniques. In: Rumelt S (ed) Glaucoma—basic and clinical concepts. INTECH Open access Publisher, Crotia, pp 371–390
5.
Zurück zum Zitat Cheng JW, Zong Y, Zeng YY, Wei RL (2014) The prevalence of primary angle closure glaucoma in adult Asians: a systematic review and meta-analysis. PLoS ONE 9:e103222PubMedPubMedCentralCrossRef Cheng JW, Zong Y, Zeng YY, Wei RL (2014) The prevalence of primary angle closure glaucoma in adult Asians: a systematic review and meta-analysis. PLoS ONE 9:e103222PubMedPubMedCentralCrossRef
6.
Zurück zum Zitat Cheon MH, Sung KR, Choi EH, Kang SY, Cho JW, Lee S, Kim JY, Tchah HW, Kook MS (2010) Effect of age on anterior chamber angle configuration in Asians determined by anterior segment optical coherence tomography: clinic-based study. Acta Ophthalmol 88:205–210CrossRef Cheon MH, Sung KR, Choi EH, Kang SY, Cho JW, Lee S, Kim JY, Tchah HW, Kook MS (2010) Effect of age on anterior chamber angle configuration in Asians determined by anterior segment optical coherence tomography: clinic-based study. Acta Ophthalmol 88:205–210CrossRef
7.
Zurück zum Zitat Congdon NG, Foster PJ, Wamsley S, Gutmark J, Nolan W, Seah SK, Johnson GJ, Broman AT (2002) Biometric gonioscopy and the effects of age, race, and sex on the anterior chamber angle. Br J Ophthalmol 86:18–22PubMedPubMedCentralCrossRef Congdon NG, Foster PJ, Wamsley S, Gutmark J, Nolan W, Seah SK, Johnson GJ, Broman AT (2002) Biometric gonioscopy and the effects of age, race, and sex on the anterior chamber angle. Br J Ophthalmol 86:18–22PubMedPubMedCentralCrossRef
8.
Zurück zum Zitat Dacosta S, Fernandes G, Rajendran B, Janakiraman P (2008) Assessment of anterior segment parameters under photopic and scotopic conditions in Indian eyes using anterior segment optical coherence tomography. Indian J Ophthalmol 56:17–22PubMedPubMedCentralCrossRef Dacosta S, Fernandes G, Rajendran B, Janakiraman P (2008) Assessment of anterior segment parameters under photopic and scotopic conditions in Indian eyes using anterior segment optical coherence tomography. Indian J Ophthalmol 56:17–22PubMedPubMedCentralCrossRef
9.
Zurück zum Zitat Fernández-Vigo J, García-Feijóo J, Martínez-de-la-Casa JM, García-Bella J, Arriola-Villalobos P, Fernández-Pérez C, Fernández-Vigo JÁ (2016) Fourier domain optical coherence topography to assess the iridocorneal angle and correlation study in a large Caucasian population. BMC Ophthalmol 16:1–7CrossRef Fernández-Vigo J, García-Feijóo J, Martínez-de-la-Casa JM, García-Bella J, Arriola-Villalobos P, Fernández-Pérez C, Fernández-Vigo JÁ (2016) Fourier domain optical coherence topography to assess the iridocorneal angle and correlation study in a large Caucasian population. BMC Ophthalmol 16:1–7CrossRef
10.
Zurück zum Zitat Flaxman SR, Bourne RRA, Resnikoff S, Ackland P, Braithwaite T, Cicinelli MV, Das A, Jonas JB, Keeffe J, Kempen JH, Leasher J, Limburg H, Naidoo K, Pesudovs K, Silvester A, Stevens GA, Tahhan N, Wong TY, Taylor HR (2017) Global causes of blindness and distance visual impairment 1990–2020: a systematic review and meta-analysis. Lancet Glob Health 5:1221–1234CrossRef Flaxman SR, Bourne RRA, Resnikoff S, Ackland P, Braithwaite T, Cicinelli MV, Das A, Jonas JB, Keeffe J, Kempen JH, Leasher J, Limburg H, Naidoo K, Pesudovs K, Silvester A, Stevens GA, Tahhan N, Wong TY, Taylor HR (2017) Global causes of blindness and distance visual impairment 1990–2020: a systematic review and meta-analysis. Lancet Glob Health 5:1221–1234CrossRef
11.
Zurück zum Zitat Friedman DS, Gazzard G, Min CB, Broman AT, Quigley H, Tielsch J, Seah S, Foster PJ (2008) Age and sex variation in angle findings among normal Chinese subjects: a comparison of UBM, Scheimpflug, and gonioscopic assessment of the anterior chamber angle. J Glaucoma 17:5–10PubMedCrossRef Friedman DS, Gazzard G, Min CB, Broman AT, Quigley H, Tielsch J, Seah S, Foster PJ (2008) Age and sex variation in angle findings among normal Chinese subjects: a comparison of UBM, Scheimpflug, and gonioscopic assessment of the anterior chamber angle. J Glaucoma 17:5–10PubMedCrossRef
12.
Zurück zum Zitat Friedman DS, He M (2008) Anterior chamber angle assessment techniques. Surv Ophthalmol 53:250–273PubMedCrossRef Friedman DS, He M (2008) Anterior chamber angle assessment techniques. Surv Ophthalmol 53:250–273PubMedCrossRef
13.
14.
Zurück zum Zitat Grewal DS, Brar GS, Jain R, Grewal SPS (2011) Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles. Eye 25:603–611PubMedPubMedCentralCrossRef Grewal DS, Brar GS, Jain R, Grewal SPS (2011) Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles. Eye 25:603–611PubMedPubMedCentralCrossRef
15.
Zurück zum Zitat Hashemi H, Khabazkhoob M, Mehravaran S, Yazdani K, Mohammad K, Fotouhi A (2009) The distribution of anterior chamber depth in a Tehran population: the Tehran eye study. Ophthalmic Physiol Opt 29:436–442PubMedCrossRef Hashemi H, Khabazkhoob M, Mehravaran S, Yazdani K, Mohammad K, Fotouhi A (2009) The distribution of anterior chamber depth in a Tehran population: the Tehran eye study. Ophthalmic Physiol Opt 29:436–442PubMedCrossRef
16.
Zurück zum Zitat Henzan IM, Tomidokoro A, Uejo C, Sakai H, Sawaguchi S, Iwase A, Araie M (2010) Ultrasound biomicroscopic configurations of the anterior ocular segment in a population-based study: the Kumejima study. Ophthalmology 117:1720–1728PubMedCrossRef Henzan IM, Tomidokoro A, Uejo C, Sakai H, Sawaguchi S, Iwase A, Araie M (2010) Ultrasound biomicroscopic configurations of the anterior ocular segment in a population-based study: the Kumejima study. Ophthalmology 117:1720–1728PubMedCrossRef
17.
Zurück zum Zitat Henzan IM, Tomidokoro A, Uejo C, Sakai H, Sawaguchi S, Iwase A, Araie M (2011) Comparison of ultrasound biomicroscopic configurations among primary angle closure, its suspects, and nonoccludable angles: the Kumejima study. Am J Ophthalmol 151:1065–1073PubMedCrossRef Henzan IM, Tomidokoro A, Uejo C, Sakai H, Sawaguchi S, Iwase A, Araie M (2011) Comparison of ultrasound biomicroscopic configurations among primary angle closure, its suspects, and nonoccludable angles: the Kumejima study. Am J Ophthalmol 151:1065–1073PubMedCrossRef
18.
Zurück zum Zitat Hosseini SMA, Abolbashari F, Mohidin N (2013) Anterior segment parameters in Indian young adults using the Pentacam. Int Ophthalmol 33:621–626CrossRef Hosseini SMA, Abolbashari F, Mohidin N (2013) Anterior segment parameters in Indian young adults using the Pentacam. Int Ophthalmol 33:621–626CrossRef
19.
Zurück zum Zitat Jin P, Li M, He X, Lu L, Zhu J, Chang TC, Zou H (2016) Anterior-chamber angle and axial length measurements in normal Chinese children. J Glaucoma 25:692–697PubMedCrossRef Jin P, Li M, He X, Lu L, Zhu J, Chang TC, Zou H (2016) Anterior-chamber angle and axial length measurements in normal Chinese children. J Glaucoma 25:692–697PubMedCrossRef
20.
Zurück zum Zitat Kapetanakis VV, Chan MPY, Foster PJ, Cook DG, Owen CG, Rudnicka AR (2016) Global variations and time trends in the prevalence of primary open angle glaucoma (POAG): a systematic review and meta-analysis. Br J Ophthalmol 100:86–93PubMedCrossRef Kapetanakis VV, Chan MPY, Foster PJ, Cook DG, Owen CG, Rudnicka AR (2016) Global variations and time trends in the prevalence of primary open angle glaucoma (POAG): a systematic review and meta-analysis. Br J Ophthalmol 100:86–93PubMedCrossRef
21.
Zurück zum Zitat Kim DY, Sung KR, Kang SY, Cho JW, Lee KS, Park SB, Kim ST, Kook MS (2011) Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography. Acta Ophthalmol 89:435–441PubMedCrossRef Kim DY, Sung KR, Kang SY, Cho JW, Lee KS, Park SB, Kim ST, Kook MS (2011) Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography. Acta Ophthalmol 89:435–441PubMedCrossRef
22.
Zurück zum Zitat Kobayashi H, Ono H, Kiryu J, Kobayashi K, Kondo T (1999) Ultrasound biomicroscopic measurement of development of the anterior chamber angle. Br J Ophthalmol 83:559–562PubMedPubMedCentralCrossRef Kobayashi H, Ono H, Kiryu J, Kobayashi K, Kondo T (1999) Ultrasound biomicroscopic measurement of development of the anterior chamber angle. Br J Ophthalmol 83:559–562PubMedPubMedCentralCrossRef
23.
Zurück zum Zitat Kyari F, Abdull MM, Bastawrous A, Gilbert CE, Faal H (2013) Epidemiology of glaucoma in Sub-Saharan Africa: prevalence, incidence and risk factors. Middle East Afr J Ophthalmol 20:111–125PubMedPubMedCentralCrossRef Kyari F, Abdull MM, Bastawrous A, Gilbert CE, Faal H (2013) Epidemiology of glaucoma in Sub-Saharan Africa: prevalence, incidence and risk factors. Middle East Afr J Ophthalmol 20:111–125PubMedPubMedCentralCrossRef
24.
Zurück zum Zitat Leung CK, Li H, Weinreb RN, Liu J, Cheung CYL, Lai RYK, Pang CP, Lam DSC (2008) Anterior chamber angle measurement with anterior segment optical coherence tomography: a comparison between slit lamp OCT and Visante OCT. Invest Ophthalmol Vis Sci 49:3469–3474PubMedCrossRef Leung CK, Li H, Weinreb RN, Liu J, Cheung CYL, Lai RYK, Pang CP, Lam DSC (2008) Anterior chamber angle measurement with anterior segment optical coherence tomography: a comparison between slit lamp OCT and Visante OCT. Invest Ophthalmol Vis Sci 49:3469–3474PubMedCrossRef
25.
Zurück zum Zitat Leung CK, Palmiero PM, Weinreb RN, Li H, Sbeity Z, Dorairaj S, Leung D, Liu S, Liebmann JM, Congdon N, Lam DS, Ritch R (2010) Comparison of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography. Br J Ophthalmol 94:1184–1189PubMedCrossRef Leung CK, Palmiero PM, Weinreb RN, Li H, Sbeity Z, Dorairaj S, Leung D, Liu S, Liebmann JM, Congdon N, Lam DS, Ritch R (2010) Comparison of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography. Br J Ophthalmol 94:1184–1189PubMedCrossRef
26.
Zurück zum Zitat Li H, Leung CKS, Cheung CYL, Wong L, Pang CP, Weinreb RN, Lam DSC (2007) Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography. Br J Ophthalmol 91:1490–1492PubMedPubMedCentralCrossRef Li H, Leung CKS, Cheung CYL, Wong L, Pang CP, Weinreb RN, Lam DSC (2007) Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography. Br J Ophthalmol 91:1490–1492PubMedPubMedCentralCrossRef
27.
Zurück zum Zitat Liu S, Yu M, Ye C, Lam DSC, Leung CKS (2011) Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurements. Invest Ophthalmol Vis Sci 52:8598–8603PubMedCrossRef Liu S, Yu M, Ye C, Lam DSC, Leung CKS (2011) Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurements. Invest Ophthalmol Vis Sci 52:8598–8603PubMedCrossRef
28.
Zurück zum Zitat Maruyama Y, Mori K, Ikeda Y, Ueno M, Kinoshita S (2014) Morphological analysis of age-related iridocorneal angle changes in normal and glaucomatous cases using anterior segment optical coherence tomography. Clin Ophthalmol 8:113–118PubMed Maruyama Y, Mori K, Ikeda Y, Ueno M, Kinoshita S (2014) Morphological analysis of age-related iridocorneal angle changes in normal and glaucomatous cases using anterior segment optical coherence tomography. Clin Ophthalmol 8:113–118PubMed
29.
Zurück zum Zitat Mou D, Fu J, Li S, Wang L, Wang X, Wu G, Qing G, Peng Y, Wang N (2010) Narrow-and open-angle measurements with anterior-segment optical coherence tomography and Pentacam. Ophthalmic Surg Lasers Imaging Retina 41:622–628CrossRef Mou D, Fu J, Li S, Wang L, Wang X, Wu G, Qing G, Peng Y, Wang N (2010) Narrow-and open-angle measurements with anterior-segment optical coherence tomography and Pentacam. Ophthalmic Surg Lasers Imaging Retina 41:622–628CrossRef
30.
Zurück zum Zitat Müller M, Dahmen G, Pӧrksen E, Geerling G, Laqua H, Ziegler A, Hoerauf H (2006) Anterior chamber angle measurement with optical coherence tomography: intraobserver and interobserver variability. J Cataract Refract Surg 32:1803–1308PubMedCrossRef Müller M, Dahmen G, Pӧrksen E, Geerling G, Laqua H, Ziegler A, Hoerauf H (2006) Anterior chamber angle measurement with optical coherence tomography: intraobserver and interobserver variability. J Cataract Refract Surg 32:1803–1308PubMedCrossRef
31.
Zurück zum Zitat Narayanaswamy A, Sakata LM, He M, Friedman DS, Chan YH, Lavanya R, Baskaran M, Foster PJ, Aung T (2010) Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study. Arch Ophthalmol 128:1321–1327PubMedCrossRef Narayanaswamy A, Sakata LM, He M, Friedman DS, Chan YH, Lavanya R, Baskaran M, Foster PJ, Aung T (2010) Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study. Arch Ophthalmol 128:1321–1327PubMedCrossRef
32.
Zurück zum Zitat Narayanaswamy A, Vijaya L, Shantha B, Baskaran M, Sathidevi AV, Baluswamy S (2004) Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy. Jpn J Ophthalmol 48:44–49PubMedCrossRef Narayanaswamy A, Vijaya L, Shantha B, Baskaran M, Sathidevi AV, Baluswamy S (2004) Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy. Jpn J Ophthalmol 48:44–49PubMedCrossRef
33.
Zurück zum Zitat Oh YG, Minelli S, Spaeth GL, Steinman WC (1994) The anterior chamber angle is different in different racial groups: a gonioscopy study. Eye 8:104–108PubMedCrossRef Oh YG, Minelli S, Spaeth GL, Steinman WC (1994) The anterior chamber angle is different in different racial groups: a gonioscopy study. Eye 8:104–108PubMedCrossRef
34.
Zurück zum Zitat Optovue (2011) iVue100 user's manual version 1.9. Optovue, USA. Optovue (2011) iVue100 user's manual version 1.9. Optovue, USA.
35.
Zurück zum Zitat Pavlin CJ, Harasiewicz K, Foster FS (1992) Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol 113:381–389PubMedCrossRef Pavlin CJ, Harasiewicz K, Foster FS (1992) Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol 113:381–389PubMedCrossRef
36.
Zurück zum Zitat Qin B, Zhou XT, Huang D, Chu RY (2011) Effects of age on ocular anterior segment dimensions measured by optical coherence tomography. Chin Med J 124:1829–1834PubMed Qin B, Zhou XT, Huang D, Chu RY (2011) Effects of age on ocular anterior segment dimensions measured by optical coherence tomography. Chin Med J 124:1829–1834PubMed
38.
Zurück zum Zitat Radhakrishnan S, Goldsmith J, Huang D, Westphal V, Dueker DK, Rollins AM, Izatt JA, Smith SD (2005) Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. Arch Ophthalmol 123:1053–1059PubMedCrossRef Radhakrishnan S, Goldsmith J, Huang D, Westphal V, Dueker DK, Rollins AM, Izatt JA, Smith SD (2005) Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. Arch Ophthalmol 123:1053–1059PubMedCrossRef
39.
Zurück zum Zitat Radhakrishnan S, Huang D, Smith SD (2005) Optical coherence tomography imaging of the anterior chamber angle. Ophthalmol Clin North Am 18:375–381PubMedCrossRef Radhakrishnan S, Huang D, Smith SD (2005) Optical coherence tomography imaging of the anterior chamber angle. Ophthalmol Clin North Am 18:375–381PubMedCrossRef
40.
Zurück zum Zitat Radhakrishnan S, See J, Smith SD, Nolan WP, Ce Z, Friedman D, Huang D, Li Y, Aung T, Chew PTK (2007) Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci 48:3683–3688PubMedCrossRef Radhakrishnan S, See J, Smith SD, Nolan WP, Ce Z, Friedman D, Huang D, Li Y, Aung T, Chew PTK (2007) Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci 48:3683–3688PubMedCrossRef
41.
Zurück zum Zitat Ramani KK, Mani B, Ronnie G, Joseph R, Lingam V (2007) Gender variation in ocular biometry and ultrasound biomicroscopy of primary angle closure suspects and normal eyes. J Glaucoma 16:122–128PubMedCrossRef Ramani KK, Mani B, Ronnie G, Joseph R, Lingam V (2007) Gender variation in ocular biometry and ultrasound biomicroscopy of primary angle closure suspects and normal eyes. J Glaucoma 16:122–128PubMedCrossRef
42.
Zurück zum Zitat Rotchford AP, Kirwan JF, Muller MA, Johnson GJ, Roux P (2003) Temba glaucoma study: a population-based cross-sectional survey in urban South Africa. Ophthalmology 110:376–382PubMedCrossRef Rotchford AP, Kirwan JF, Muller MA, Johnson GJ, Roux P (2003) Temba glaucoma study: a population-based cross-sectional survey in urban South Africa. Ophthalmology 110:376–382PubMedCrossRef
43.
Zurück zum Zitat Rüfer F, Schrӧder A, Klettner A, Frimpong-Boateng A, Roider JB, Erb C (2010) Anterior chamber depth and iridocorneal angle in healthy White subjects: effects of age, gender and refraction. Acta Ophthalmol 88:885–890PubMedCrossRef Rüfer F, Schrӧder A, Klettner A, Frimpong-Boateng A, Roider JB, Erb C (2010) Anterior chamber depth and iridocorneal angle in healthy White subjects: effects of age, gender and refraction. Acta Ophthalmol 88:885–890PubMedCrossRef
44.
Zurück zum Zitat Sakata LM, Wong TTL, Wong HT, Kumar RS, Htoon HM, Aung HT, He M, Aung T (2010) Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle. Eye 24:578–587PubMedCrossRef Sakata LM, Wong TTL, Wong HT, Kumar RS, Htoon HM, Aung HT, He M, Aung T (2010) Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle. Eye 24:578–587PubMedCrossRef
45.
Zurück zum Zitat Schuster AK, Pfeiffer N, Nickels S, Schulz A, Höhn R, Wild PS, Binder H, Münzel T, Beutel ME, Vossmerbaeumer U (2016) Distribution of anterior chamber angle width and correlation with age, refraction, and anterior chamber depth—the Gutenberg health study. Invest Ophthalmol Vis Sci 57:3740–3746PubMedCrossRef Schuster AK, Pfeiffer N, Nickels S, Schulz A, Höhn R, Wild PS, Binder H, Münzel T, Beutel ME, Vossmerbaeumer U (2016) Distribution of anterior chamber angle width and correlation with age, refraction, and anterior chamber depth—the Gutenberg health study. Invest Ophthalmol Vis Sci 57:3740–3746PubMedCrossRef
46.
Zurück zum Zitat Shimizu Y, Nakakura S, Nagasawa T, Okamoto A, Tabuchi H, Kiuchi Y (2017) Comparison of the anterior chamber angle structure between children and adults. J AAPOS 21:57–62PubMedCrossRef Shimizu Y, Nakakura S, Nagasawa T, Okamoto A, Tabuchi H, Kiuchi Y (2017) Comparison of the anterior chamber angle structure between children and adults. J AAPOS 21:57–62PubMedCrossRef
47.
Zurück zum Zitat Sihota R, Vashisht P, Sharma A, Chakraborty S, Gupta V, Pandey RM (2012) Anterior segment optical coherence tomography characteristics in an Asian population. J Glaucoma 21:180–185PubMedCrossRef Sihota R, Vashisht P, Sharma A, Chakraborty S, Gupta V, Pandey RM (2012) Anterior segment optical coherence tomography characteristics in an Asian population. J Glaucoma 21:180–185PubMedCrossRef
48.
Zurück zum Zitat Sun JH, Sung KR, Yun SC, Cheon MH, Tchah HW, Kim MJ, Kim JY (2012) Factors associated with anterior chamber narrowing with age: an optical coherence tomography study. Invest Ophthalmol Vis Sci 53:2607–2610PubMedCrossRef Sun JH, Sung KR, Yun SC, Cheon MH, Tchah HW, Kim MJ, Kim JY (2012) Factors associated with anterior chamber narrowing with age: an optical coherence tomography study. Invest Ophthalmol Vis Sci 53:2607–2610PubMedCrossRef
49.
Zurück zum Zitat Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040. Ophthalmology 121:2081–2090PubMedCrossRef Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040. Ophthalmology 121:2081–2090PubMedCrossRef
50.
Zurück zum Zitat Wang D, Chiu C, He M, Wu L, Kao A, Lin S (2011) Differences in baseline dark and the dark-to-light changes in anterior chamber angle parameters in whites and ethnic Chinese. Invest Ophthalmol Vis Sci 52:9404–9410PubMedPubMedCentralCrossRef Wang D, Chiu C, He M, Wu L, Kao A, Lin S (2011) Differences in baseline dark and the dark-to-light changes in anterior chamber angle parameters in whites and ethnic Chinese. Invest Ophthalmol Vis Sci 52:9404–9410PubMedPubMedCentralCrossRef
51.
Zurück zum Zitat Wang D, Pekmezci M, Basham RP, He M, Seider MI, Lin SC (2009) Comparison of different modes in optical coherence tomography and ultrasound biomicroscopy in anterior chamber angle assessment. J Glaucoma 18:472–478PubMedCrossRef Wang D, Pekmezci M, Basham RP, He M, Seider MI, Lin SC (2009) Comparison of different modes in optical coherence tomography and ultrasound biomicroscopy in anterior chamber angle assessment. J Glaucoma 18:472–478PubMedCrossRef
52.
Zurück zum Zitat Wirbelauer C, Karandish A, Häberle H, Pham DT (2005) Noncontact goniometry with optical coherence tomography. Arch Ophthalmol 123:179–185PubMedCrossRef Wirbelauer C, Karandish A, Häberle H, Pham DT (2005) Noncontact goniometry with optical coherence tomography. Arch Ophthalmol 123:179–185PubMedCrossRef
53.
Zurück zum Zitat Wong HT, Lim MC, Sakata LM, Aung HT, Amerasinghe N, Friedman DS, Aung T (2009) High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol 127:256–260PubMedCrossRef Wong HT, Lim MC, Sakata LM, Aung HT, Amerasinghe N, Friedman DS, Aung T (2009) High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol 127:256–260PubMedCrossRef
54.
Zurück zum Zitat Wylęgała E, Teper S, Nowińska AK, Milka M, Dobrowolski D (2009) Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 35:1410–1414PubMedCrossRef Wylęgała E, Teper S, Nowińska AK, Milka M, Dobrowolski D (2009) Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 35:1410–1414PubMedCrossRef
55.
Zurück zum Zitat Xu L, Cao W, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing eye study. Am J Ophthalmol 145:929–936PubMedCrossRef Xu L, Cao W, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing eye study. Am J Ophthalmol 145:929–936PubMedCrossRef
Metadaten
Titel
Distribution of anterior chamber angle measurements in South African young adults: an optical coherence tomography study
verfasst von
Nishanee Rampersad
Rekha Hansraj
Publikationsdatum
05.01.2022
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 6/2022
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-021-02164-7

Neu im Fachgebiet Augenheilkunde

Zirkulierende Tumorzellen bei uvealem Melanom

Die Erstbeschreibung von Tumorzellen in der Blutbahn erfolgte 1869 durch Thomas Ashworth. Dieser beschrieb in der Blutprobe eines metastasierten Krebskranken „cells identical with those of the cancer itself“ und postulierte, dass diese „may tend …

Elektrophysiologie in der Augenheilkunde

Mit elektrophysiologischen Untersuchungen kann man in der Augenheilkunde die Funktionalität der Neurone der Sehbahn untersuchen. Weil elektrophysiologische Ableitungen von der subjektiven Wahrnehmung und Antwort des Patienten unabhängig sind …

„Liquid biopsy“ bei Retinoblastom

Die „liquid biopsy“ spielt eine zunehmend wichtige Rolle bei der Diagnose und Behandlung des Retinoblastoms. Die Möglichkeit der sicheren und unkomplizierten Entnahme und Untersuchung von Kammerwasser aus der Vorderkammer trägt wesentlich zur …

Die „onkologische Spur“: zirkulierende Tumor-DNA beim Aderhautmelanom

In Körperflüssigkeiten wurde zirkulierende Desoxyribonukleinsäure (DNA) bereits vor mehr als 75 Jahren beschrieben [ 19 ]. Aber erst durch die eindrucksvolle technische Weiterentwicklung im Bereich der Nukleinsäureanalyse in den letzten Jahren ist …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.