Skip to main content
Erschienen in: Lasers in Medical Science 9/2018

13.06.2018 | Original Article

Diurnal variations and pulpal status: is there a need for FFT besides LDF?

verfasst von: Herman J.J. Roeykens, Roeland J.G. De Moor

Erschienen in: Lasers in Medical Science | Ausgabe 9/2018

Einloggen, um Zugang zu erhalten

Abstract

The aim of this article was to investigate the use of laser Doppler flowmetry (LDF) combined with a fast Fourier transformation (FFT). LDF data in relation to three different scenarios were evaluated: (a) LDF records of a right central upper incisor of one patient were used for FFT analysis. These records were obtained by means of 30 pre-manufactured splints, handled by dentists without any experience in LDF recording. (b) Diurnal variations in one patient were analysed with LDF and FFT using 11 splints by one and same experienced investigator at four specific moments of the day. (c) Pulpal status was analysed using 17 splints. Eleven for a patient, standing as case model and six splints for six other patients. In this specific group, each patient had one vital and one non-vital central maxillary incisor and was analysed separately by LDF and FFT. The data of assessment (b) showed diurnal variations on LDF values of almost 80%, indicating that LDF registration is best performed in the same time period of the day. Data verification with FFT confirmed the findings without FFT of assessment (a) and (b). In assessment, (c) FFT demonstrated a clear distinction between a vital and a non-vital pulp for those cases with one vital tooth and one root canal treated tooth. In those cases with one vital incisor and the other traumatised, FFT was undeterminated. Considered that FFT was obtained after LDF recording and remained undeterminated for a decision in cases with decreasing pulpal blood flow in time, the added value of FFT in pulpal traumatology was minimal.
Literatur
1.
Zurück zum Zitat Jafarzadeh H, Abbott PV (2010) Review of pulp sensibility tests. Part I: general information and thermal tests. Int Endod J 43:738–762CrossRef Jafarzadeh H, Abbott PV (2010) Review of pulp sensibility tests. Part I: general information and thermal tests. Int Endod J 43:738–762CrossRef
2.
Zurück zum Zitat Jafarzadeh H, Abbott PV (2010) Review of pulp sensibility tests. Part II: electric pulp tests and test cavities. Int Endod J 43:945–958CrossRef Jafarzadeh H, Abbott PV (2010) Review of pulp sensibility tests. Part II: electric pulp tests and test cavities. Int Endod J 43:945–958CrossRef
3.
Zurück zum Zitat McMorrow RC, Mythen MG (2006) Pulse oximetry. Curr Opin Crit Care 12:269–271PubMed McMorrow RC, Mythen MG (2006) Pulse oximetry. Curr Opin Crit Care 12:269–271PubMed
4.
Zurück zum Zitat Calil E, Calderia CL, Gavini G, Lemos EM (2008) Determination of pulp vitality in vivo with pulse oximetry. Int Endod J 41:741–746CrossRef Calil E, Calderia CL, Gavini G, Lemos EM (2008) Determination of pulp vitality in vivo with pulse oximetry. Int Endod J 41:741–746CrossRef
5.
Zurück zum Zitat Gopikrishna V, Tinagupta K, Kandaswamy D (2007) Evaluation of efficacy of a new custom-made pulse oximeter dental probe in comparison with the electrical and thermal tests for assessing pulp vitality. J Endod 33:411–414CrossRef Gopikrishna V, Tinagupta K, Kandaswamy D (2007) Evaluation of efficacy of a new custom-made pulse oximeter dental probe in comparison with the electrical and thermal tests for assessing pulp vitality. J Endod 33:411–414CrossRef
6.
Zurück zum Zitat Chen E, Abbott PV (2009) Dental pulp testing: a review. Int J Dent 2009:365785CrossRef Chen E, Abbott PV (2009) Dental pulp testing: a review. Int J Dent 2009:365785CrossRef
7.
Zurück zum Zitat Gazelius B, Olgart L, Edwall B, Edwall L (1986) Non-invasive recording of blood flow in human dental pulp. Endod Dent Traumatol 2:219–221CrossRef Gazelius B, Olgart L, Edwall B, Edwall L (1986) Non-invasive recording of blood flow in human dental pulp. Endod Dent Traumatol 2:219–221CrossRef
8.
Zurück zum Zitat Wilder-Smith PE (1988) A new method for the non-invasive measurement of pulpal blood flow. Int Endod J 21:307–312CrossRef Wilder-Smith PE (1988) A new method for the non-invasive measurement of pulpal blood flow. Int Endod J 21:307–312CrossRef
9.
Zurück zum Zitat Ôberg PA (1990) Laser-Doppler flowmetry. Crit Review Biomed Engin 18:125–163 Ôberg PA (1990) Laser-Doppler flowmetry. Crit Review Biomed Engin 18:125–163
10.
Zurück zum Zitat Musselwhite JM, Klitzman B, Maixner W, Burkes EJ Jr (1997) Laser Doppler flowmetry: a clinical test of pulpal vitality. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 84:411–419CrossRef Musselwhite JM, Klitzman B, Maixner W, Burkes EJ Jr (1997) Laser Doppler flowmetry: a clinical test of pulpal vitality. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 84:411–419CrossRef
11.
Zurück zum Zitat Fratkin RD, Kenny DJ, Johnston DH (1999) Evaluation of a laser Doppler flowmeter to assess blood flow in human primary incisor teeth. Pediatr Dent 21:53–56PubMed Fratkin RD, Kenny DJ, Johnston DH (1999) Evaluation of a laser Doppler flowmeter to assess blood flow in human primary incisor teeth. Pediatr Dent 21:53–56PubMed
12.
Zurück zum Zitat Jafarzadeh H (2009) Laser Doppler flowmetry in endodontics: a review. Int Endod J 42:476–490CrossRef Jafarzadeh H (2009) Laser Doppler flowmetry in endodontics: a review. Int Endod J 42:476–490CrossRef
13.
Zurück zum Zitat Hartmann A, Azérad J, Boucher Y (1996) Environmental effects on laser Doppler pulpal blood-flow measurements in man. Arch Oral Biol 41:333–339CrossRef Hartmann A, Azérad J, Boucher Y (1996) Environmental effects on laser Doppler pulpal blood-flow measurements in man. Arch Oral Biol 41:333–339CrossRef
14.
Zurück zum Zitat Sasano T, Kuriwada S, Sanjo D (1989) Arterial blood pressure regulation of pulpal blood flow as determined by laser Doppler. J Dent Res 68:791–795CrossRef Sasano T, Kuriwada S, Sanjo D (1989) Arterial blood pressure regulation of pulpal blood flow as determined by laser Doppler. J Dent Res 68:791–795CrossRef
15.
Zurück zum Zitat Ajcharanukul O, Chunhacheevachaloke E, Vorachart P, Chidchuangchai W (2013) The postural autonomic regulation of pulpal blood flow. J Dent Res 92:156–160CrossRef Ajcharanukul O, Chunhacheevachaloke E, Vorachart P, Chidchuangchai W (2013) The postural autonomic regulation of pulpal blood flow. J Dent Res 92:156–160CrossRef
16.
Zurück zum Zitat Aoki K, Shiojiri T, Shibasaki M, Takano S, Kondo N, Iwata A (1995) The effect of diurnal variation on the regional differences in sweating and skin blood flow during exercise. Eur J Appl Physiol 71:276–280CrossRef Aoki K, Shiojiri T, Shibasaki M, Takano S, Kondo N, Iwata A (1995) The effect of diurnal variation on the regional differences in sweating and skin blood flow during exercise. Eur J Appl Physiol 71:276–280CrossRef
17.
Zurück zum Zitat Svalestad J, Hellem S, VaagbØ G, Irgens Å, Thorsen E (2010) Reproducibility of transcutaneous oximetry and laser Doppler flowmetry in facial skin and gingival tissue. Microvasc Res 79:29–33CrossRef Svalestad J, Hellem S, VaagbØ G, Irgens Å, Thorsen E (2010) Reproducibility of transcutaneous oximetry and laser Doppler flowmetry in facial skin and gingival tissue. Microvasc Res 79:29–33CrossRef
18.
Zurück zum Zitat Roeykens HJ, Deschepper E, De Moor RJ (2016) Laser Doppler flowmetry: reproducibility, reliability, and diurnal blood flow variations. Lasers Med Sci 31(6):1083–1092CrossRef Roeykens HJ, Deschepper E, De Moor RJ (2016) Laser Doppler flowmetry: reproducibility, reliability, and diurnal blood flow variations. Lasers Med Sci 31(6):1083–1092CrossRef
19.
Zurück zum Zitat Akpinar KE, Er K, Polat S, Polat NT (2004) Effect of gingiva on laser Doppler pulpal blood flow measurements. J Endod 30:138–140CrossRef Akpinar KE, Er K, Polat S, Polat NT (2004) Effect of gingiva on laser Doppler pulpal blood flow measurements. J Endod 30:138–140CrossRef
20.
Zurück zum Zitat Soo-ampon S, Vongsavan N, Soo-ampon M, Chuckpaiwong S, Matthews B (2003) The sources of laser Doppler blood-flow signals recorded from human teeth. Arch Oral Biol 48(5):353–360CrossRef Soo-ampon S, Vongsavan N, Soo-ampon M, Chuckpaiwong S, Matthews B (2003) The sources of laser Doppler blood-flow signals recorded from human teeth. Arch Oral Biol 48(5):353–360CrossRef
21.
Zurück zum Zitat Polat S, Er K, Akpinar K, Polat N (2004) The sources of laser Doppler blood-flow signals recorded from vital and root canal treated teeth. Arch Oral Biol 49(1):53–57CrossRef Polat S, Er K, Akpinar K, Polat N (2004) The sources of laser Doppler blood-flow signals recorded from vital and root canal treated teeth. Arch Oral Biol 49(1):53–57CrossRef
22.
Zurück zum Zitat Ramsey DS, Artun J, Martinen SS (1991) Reliability of pulpal blood-flow measurements utilizing laser Doppler flowmetry. J Dent Res 70:1427–1430CrossRef Ramsey DS, Artun J, Martinen SS (1991) Reliability of pulpal blood-flow measurements utilizing laser Doppler flowmetry. J Dent Res 70:1427–1430CrossRef
23.
Zurück zum Zitat Setzer FC, Challagulla P, Kataoka SHH, Trope M (2013) Effect of tooth isolation on laser Doppler readings. Int Endod J 46:517–522CrossRef Setzer FC, Challagulla P, Kataoka SHH, Trope M (2013) Effect of tooth isolation on laser Doppler readings. Int Endod J 46:517–522CrossRef
24.
Zurück zum Zitat Ingólfsson AR, Tronstad L, Hersh EV, Riva CE (1993) Effect of probe design on the suitability of laser Doppler flowmetry in vitality testing of human teeth. Endod Dent Traumatol 9:65–70CrossRef Ingólfsson AR, Tronstad L, Hersh EV, Riva CE (1993) Effect of probe design on the suitability of laser Doppler flowmetry in vitality testing of human teeth. Endod Dent Traumatol 9:65–70CrossRef
25.
Zurück zum Zitat Ingólfsson AR, Tronstad L, Riva CE (1994) Reliability of laser Doppler flowmetry in testing vitality of human teeth. Endod Dent Traumatol 10:185–187CrossRef Ingólfsson AR, Tronstad L, Riva CE (1994) Reliability of laser Doppler flowmetry in testing vitality of human teeth. Endod Dent Traumatol 10:185–187CrossRef
26.
Zurück zum Zitat Odor TM, Ford TR, McDonald F (1996) Effect of probe design and bandwidth on laser Doppler readings from vital and root-filled teeth. Med Eng Phys 18:359–364CrossRef Odor TM, Ford TR, McDonald F (1996) Effect of probe design and bandwidth on laser Doppler readings from vital and root-filled teeth. Med Eng Phys 18:359–364CrossRef
27.
Zurück zum Zitat Shimazaki T, Shimada J, Yamazaki Y et al (1989) Measurement of oral and facial blood flow with a laser Doppler flowmeter. 4. Alteration of oral blood flow by position change. Meikai Daigaku Shigaku Zasshi 18(3):302–306PubMed Shimazaki T, Shimada J, Yamazaki Y et al (1989) Measurement of oral and facial blood flow with a laser Doppler flowmeter. 4. Alteration of oral blood flow by position change. Meikai Daigaku Shigaku Zasshi 18(3):302–306PubMed
28.
Zurück zum Zitat Roeykens H, Van Maele G, De Moor R, Martens L (1999) Reliability of laser Doppler flowmetry in a 2-probe assessment of pulpal blood flow. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 87:742–748CrossRef Roeykens H, Van Maele G, De Moor R, Martens L (1999) Reliability of laser Doppler flowmetry in a 2-probe assessment of pulpal blood flow. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 87:742–748CrossRef
29.
Zurück zum Zitat Roeykens HJ, De Moor RJ. Laser Doppler flowmetry (2016) In G. Olivi et al. Lasers in endodontics: scientific background and clinical applications, Springer International Publishing Switserland. p. 171–90 Roeykens HJ, De Moor RJ. Laser Doppler flowmetry (2016) In G. Olivi et al. Lasers in endodontics: scientific background and clinical applications, Springer International Publishing Switserland. p. 171–90
30.
Zurück zum Zitat Bruning RS, Kenney WL, Alexander LM (2015 Jan) Altered skin flowmotion in hypertensive humans. Microvasc Res 97:81–87CrossRef Bruning RS, Kenney WL, Alexander LM (2015 Jan) Altered skin flowmotion in hypertensive humans. Microvasc Res 97:81–87CrossRef
31.
Zurück zum Zitat Miles B, Davis S, Crandall C, Ellis E 3rd (2010) Laser-Doppler examination of the blood supply in pericranial flaps. J Oral Maxillofac Surg 68(8):1740–1745CrossRef Miles B, Davis S, Crandall C, Ellis E 3rd (2010) Laser-Doppler examination of the blood supply in pericranial flaps. J Oral Maxillofac Surg 68(8):1740–1745CrossRef
32.
Zurück zum Zitat Siegert R, Klitzing L. (1996) Laser Doppler flow signal frequency analysis in physiological and drug modified nasal flow motion. HNO. Sep;44(9):497–502. GermanCrossRef Siegert R, Klitzing L. (1996) Laser Doppler flow signal frequency analysis in physiological and drug modified nasal flow motion. HNO. Sep;44(9):497–502. GermanCrossRef
33.
Zurück zum Zitat Stansberry KB, Shapiro SA, Hill MA, McNitt PM, Meyer MD, Vinik AI. (1996) Impaired peripheral vasomotion in diabetes. Diabetes Care. Jul;19(7):715–721CrossRef Stansberry KB, Shapiro SA, Hill MA, McNitt PM, Meyer MD, Vinik AI. (1996) Impaired peripheral vasomotion in diabetes. Diabetes Care. Jul;19(7):715–721CrossRef
34.
Zurück zum Zitat Michelson G, Schmauss B (1995) Two dimensional mapping of the perfusion of the retina and optic nerve head. Br J Ophthalmol 79(12):1126–1132CrossRef Michelson G, Schmauss B (1995) Two dimensional mapping of the perfusion of the retina and optic nerve head. Br J Ophthalmol 79(12):1126–1132CrossRef
35.
Zurück zum Zitat Stefanovska A, Bračič M (1999) Physics of the human cardiovascular system. Contemp Phys 40(1):31–55CrossRef Stefanovska A, Bračič M (1999) Physics of the human cardiovascular system. Contemp Phys 40(1):31–55CrossRef
36.
Zurück zum Zitat Bračič M., McClintock P, Stefanovska A. (2000) Characteristic frequencies of the human blood distribution system. Stochastic and Chaotic Dynamics in the Lakes. Broomhead D. S, Luchinskaya E. A, McClintock P.V.E, Mullin T. Eds. Melville, NY: American Institute of Physics, 2000,146–53 Bračič M., McClintock P, Stefanovska A. (2000) Characteristic frequencies of the human blood distribution system. Stochastic and Chaotic Dynamics in the Lakes. Broomhead D. S, Luchinskaya E. A, McClintock P.V.E, Mullin T. Eds. Melville, NY: American Institute of Physics, 2000,146–53
37.
Zurück zum Zitat Kvandal P, Landsverk SA, Bernjak A, Stefanovska A, Kvernmo HD, Kirkebøen KA (2006) Low-frequency oscillations of the laser Doppler perfusion signal in human skin. Microvasc Res 72(3):120–127CrossRef Kvandal P, Landsverk SA, Bernjak A, Stefanovska A, Kvernmo HD, Kirkebøen KA (2006) Low-frequency oscillations of the laser Doppler perfusion signal in human skin. Microvasc Res 72(3):120–127CrossRef
38.
Zurück zum Zitat Stefanovska A (2007) Coupled oscillators. Complex but not complicated cardiovascular and brain interactions. IEEE Eng Med Biol Mag 26(6):25–29CrossRef Stefanovska A (2007) Coupled oscillators. Complex but not complicated cardiovascular and brain interactions. IEEE Eng Med Biol Mag 26(6):25–29CrossRef
39.
Zurück zum Zitat Kijsamanmith K, Timpawat S, Vongsavan N, Matthews B (2011) A comparison between red and infrared light for recording pulpal blood flow from human anterior teeth with a laser Doppler flow meter. Arch Oral Biol 56:614–618CrossRef Kijsamanmith K, Timpawat S, Vongsavan N, Matthews B (2011) A comparison between red and infrared light for recording pulpal blood flow from human anterior teeth with a laser Doppler flow meter. Arch Oral Biol 56:614–618CrossRef
Metadaten
Titel
Diurnal variations and pulpal status: is there a need for FFT besides LDF?
verfasst von
Herman J.J. Roeykens
Roeland J.G. De Moor
Publikationsdatum
13.06.2018
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 9/2018
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-018-2550-5

Weitere Artikel der Ausgabe 9/2018

Lasers in Medical Science 9/2018 Zur Ausgabe