Skip to main content
Erschienen in: Neuroradiology 7/2018

20.04.2018 | Interventional Neuroradiology

Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?

verfasst von: Jeongjun Lee, Young Dae Cho, Dong Hyun Yoo, Hyun-Seung Kang, Won-Sang Cho, Jeong Eun Kim, Jusun Moon, Moon Hee Han

Erschienen in: Neuroradiology | Ausgabe 7/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Self-expandable stents have enabled endovascular treatment of wide-necked aneurysms (ordinarily viewed as technically prohibitive), with favorable outcomes. However, the impact of stent type on occlusive stability has not been adequately investigated. In small-sized unruptured saccular aneurysms, we generated estimates of stent-assisted coil embolization outcomes during follow-up monitoring. Stent type and other risk factors linked to recanalization were analyzed.

Methods

A cohort of 286 patients harboring 312 small-sized unruptured aneurysms (< 10 mm) was subjected to mid-term and extended follow-up monitoring after stent-assisted coiling. Three types of stents (Enterprise, 192; Neuroform, 27; LVIS, 93) were deployed in this population; all medical records and radiologic data of which were reviewed. Mid-term recanalization rates and related risk factors were assessed using binary logistic regression analysis.

Results

A total of 49 aneurysms (15.7%) displayed recanalization at 6 months postembolization, with 34 and 15 instances of minor and major recanalization, respectively. Multivariate analysis indicated that wide-necked aneurysms (> 4 mm) (HR = 2.362; p = 0.017), incomplete occlusion at time of coiling (HR = 2.949; p = 0.002), and stent type (p = 0.048) were significant factors in mid-term recanalization, whereas hypertension (p = 0.095) and packing density ≤ 30% (p = 0.213) fell short of statistical significance. Compared with Enterprise (HR = 2.828) or Neuroform (HR = 4.206) stents, outcomes proved more favorable with use of LVIS.

Conclusions

Above findings demonstrate that in addition to occlusive status at time of coil embolization and neck size, stent type may affect follow-up outcomes of stent-assisted coil embolization in small-sized aneurysms. LVIS (vs Enterprise or Neuroform stents) performed best during follow-up monitoring in terms of limiting recanalization.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Lee SJ, Cho YD, Kang HS, Kim JE, Han MH (2013) Coil embolization using the self-expandable closed-cell stent for intracranial saccular aneurysm: a single-center experience of 289 consecutive aneurysms. Clin Radiol 68:256–263CrossRefPubMed Lee SJ, Cho YD, Kang HS, Kim JE, Han MH (2013) Coil embolization using the self-expandable closed-cell stent for intracranial saccular aneurysm: a single-center experience of 289 consecutive aneurysms. Clin Radiol 68:256–263CrossRefPubMed
2.
Zurück zum Zitat Cho YD, Kang HS, Kim JE, Cho WS, Kwon HJ, Koh HS, Han MH (2014) Modified protection using far proximal portion of self-expandable closed-cell stents for embolization of wide-necked intracranial aneurysms. Neuroradiology 56:851–857CrossRefPubMed Cho YD, Kang HS, Kim JE, Cho WS, Kwon HJ, Koh HS, Han MH (2014) Modified protection using far proximal portion of self-expandable closed-cell stents for embolization of wide-necked intracranial aneurysms. Neuroradiology 56:851–857CrossRefPubMed
3.
Zurück zum Zitat Cho YD, Kang HS, Lee WJ et al (2103) Stent-assisted coil embolization of wide-necked posterior inferior cerebellar artery aneurysms. Neuroradiology 55:877–882CrossRef Cho YD, Kang HS, Lee WJ et al (2103) Stent-assisted coil embolization of wide-necked posterior inferior cerebellar artery aneurysms. Neuroradiology 55:877–882CrossRef
4.
Zurück zum Zitat Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, Moret J (2010) Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110–115CrossRefPubMed Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, Moret J (2010) Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110–115CrossRefPubMed
5.
Zurück zum Zitat Spiotta AM, Miranpuri A, Chaudry MI et al (2013) Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms. J Neurointerv Surg 5(Suppl 3):iii79–iii82CrossRefPubMed Spiotta AM, Miranpuri A, Chaudry MI et al (2013) Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms. J Neurointerv Surg 5(Suppl 3):iii79–iii82CrossRefPubMed
6.
Zurück zum Zitat Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRefPubMed Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRefPubMed
7.
Zurück zum Zitat Aenis M, Stancampiano AP, Wakhloo AK, Lieber BB (1997) Modeling of flow in a straight stented and nonstented side wall aneurysm model. J Biomech Eng 119:206–212CrossRefPubMed Aenis M, Stancampiano AP, Wakhloo AK, Lieber BB (1997) Modeling of flow in a straight stented and nonstented side wall aneurysm model. J Biomech Eng 119:206–212CrossRefPubMed
8.
Zurück zum Zitat Phatouros CC, Sasaki TY, Higashida RT et al (2000) Stent-supported coil embolization: the treatment of fusiform and wide-neck aneurysms and pseudoaneurysms. Neurosurgery 47:107–113PubMed Phatouros CC, Sasaki TY, Higashida RT et al (2000) Stent-supported coil embolization: the treatment of fusiform and wide-neck aneurysms and pseudoaneurysms. Neurosurgery 47:107–113PubMed
9.
Zurück zum Zitat Cho YD, Sohn CH, Kang HS, Kim JE, Cho WS, Hwang G, Kwon OK, Ko MS, Park NM, Han MH (2014) Coil embolization of intracranial saccular aneurysms using the low-profile visualized intraluminal support (LVIS™) device. Neuroradiology 56:543–551CrossRefPubMed Cho YD, Sohn CH, Kang HS, Kim JE, Cho WS, Hwang G, Kwon OK, Ko MS, Park NM, Han MH (2014) Coil embolization of intracranial saccular aneurysms using the low-profile visualized intraluminal support (LVIS™) device. Neuroradiology 56:543–551CrossRefPubMed
10.
Zurück zum Zitat Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, Lamoureux J, Chagnon M, Roy D (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403CrossRefPubMed Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, Lamoureux J, Chagnon M, Roy D (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403CrossRefPubMed
11.
Zurück zum Zitat Jeon JP, Cho YD, Rhim JK, Yoo DH, Kang HS, Kim JE, Cho WS, Han MH (2016) Extended monitoring of coiled aneurysms completely occluded at 6-month follow-up: late recanalization rate and related risk factors. Eur Radiol 26:3319–3326CrossRefPubMed Jeon JP, Cho YD, Rhim JK, Yoo DH, Kang HS, Kim JE, Cho WS, Han MH (2016) Extended monitoring of coiled aneurysms completely occluded at 6-month follow-up: late recanalization rate and related risk factors. Eur Radiol 26:3319–3326CrossRefPubMed
12.
Zurück zum Zitat Cho YD, Jeon JP, Rhim JK, Park JJ, Yoo RE, Kang HS, Kim JE, Cho WS, Han MH (2015) Progressive thrombosis of small saccular aneurysms filled with contrast immediately after coil embolization: analysis of related factors and long-term follow-up. Neuroradiology 57:615–623CrossRefPubMed Cho YD, Jeon JP, Rhim JK, Park JJ, Yoo RE, Kang HS, Kim JE, Cho WS, Han MH (2015) Progressive thrombosis of small saccular aneurysms filled with contrast immediately after coil embolization: analysis of related factors and long-term follow-up. Neuroradiology 57:615–623CrossRefPubMed
13.
Zurück zum Zitat Gao B, Baharoglu MI, Cohen AD, Malek AM (2012) Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle remodeling. AJNR Am J Neuroradiol 33:649–654CrossRefPubMed Gao B, Baharoglu MI, Cohen AD, Malek AM (2012) Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle remodeling. AJNR Am J Neuroradiol 33:649–654CrossRefPubMed
14.
Zurück zum Zitat Cho YD, Lee WJ, Kim KM, Kang HS, Kim JE, Han MH (2013) Stent-assisted coil embolization of posterior communicating artery aneurysms. AJNR Am J Neuroradiol 34:2171–2176CrossRefPubMed Cho YD, Lee WJ, Kim KM, Kang HS, Kim JE, Han MH (2013) Stent-assisted coil embolization of posterior communicating artery aneurysms. AJNR Am J Neuroradiol 34:2171–2176CrossRefPubMed
15.
Zurück zum Zitat Fiorella D, Albuquerque FC, Han P et al (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16CrossRefPubMed Fiorella D, Albuquerque FC, Han P et al (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–16CrossRefPubMed
16.
Zurück zum Zitat Higashida RT, Halbach VV, Dowd CF, Juravsky L, Meagher S (2005) Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent. AJNR Am J Neuroradiol 26:1751–1756PubMed Higashida RT, Halbach VV, Dowd CF, Juravsky L, Meagher S (2005) Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent. AJNR Am J Neuroradiol 26:1751–1756PubMed
17.
Zurück zum Zitat Cho WS, Hong HS, Kang HS, Kim JE, Cho YD, Kwon OK, Bang JS, Hwang G, Son YJ, Oh CW, Han MH (2015) Stability of cerebral aneurysms after stent-assisted coil embolization: a propensity score-matched analysis. Neurosurgery 77:208–216CrossRefPubMed Cho WS, Hong HS, Kang HS, Kim JE, Cho YD, Kwon OK, Bang JS, Hwang G, Son YJ, Oh CW, Han MH (2015) Stability of cerebral aneurysms after stent-assisted coil embolization: a propensity score-matched analysis. Neurosurgery 77:208–216CrossRefPubMed
18.
Zurück zum Zitat Phan K, Huo YR, Jia F, Phan S, Rao PJ, Mobbs RJ, Mortimer AM (2016) Meta-analysis of stent-assisted coiling versus coiling-only for the treatment of intracranial aneurysms. J Clin Neurosci 31:15–22CrossRefPubMed Phan K, Huo YR, Jia F, Phan S, Rao PJ, Mobbs RJ, Mortimer AM (2016) Meta-analysis of stent-assisted coiling versus coiling-only for the treatment of intracranial aneurysms. J Clin Neurosci 31:15–22CrossRefPubMed
19.
Zurück zum Zitat Cho YD, Lee JY, Seo JH, Lee SJ, Kang HS, Kim JE, Son YJ, Jung KH, Kwon OK, Han MH (2012) Does stent implantation improve the result of repeat embolization in recanalized aneurysms? Neurosurgery 71:ons253–ons259CrossRefPubMed Cho YD, Lee JY, Seo JH, Lee SJ, Kang HS, Kim JE, Son YJ, Jung KH, Kwon OK, Han MH (2012) Does stent implantation improve the result of repeat embolization in recanalized aneurysms? Neurosurgery 71:ons253–ons259CrossRefPubMed
20.
Zurück zum Zitat Kim DJ, Suh SH, Lee JW, Kim BM, Lee JW, Huh SK, Kim DI (2010) Influences of stents on the outcome of coil embolized intracranial aneurysms: comparison between a stent-remodeled and non-remodeled treatment. Acta Neurochir 152:423–429CrossRefPubMed Kim DJ, Suh SH, Lee JW, Kim BM, Lee JW, Huh SK, Kim DI (2010) Influences of stents on the outcome of coil embolized intracranial aneurysms: comparison between a stent-remodeled and non-remodeled treatment. Acta Neurochir 152:423–429CrossRefPubMed
21.
Zurück zum Zitat Izar B, Rai A, Raghuram K, Rotruck J, Carpenter J (2011) Comparison of devices used for stent-assisted coiling of intracranial aneurysms. PLoS One 6:e24875CrossRefPubMedPubMedCentral Izar B, Rai A, Raghuram K, Rotruck J, Carpenter J (2011) Comparison of devices used for stent-assisted coiling of intracranial aneurysms. PLoS One 6:e24875CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Meng H, Wang Z, Kim M, Ecker RD, Hopkins LN (2006) Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting. AJNR Am J Neuroradiol 27:1861–1865PubMedPubMedCentral Meng H, Wang Z, Kim M, Ecker RD, Hopkins LN (2006) Saccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting. AJNR Am J Neuroradiol 27:1861–1865PubMedPubMedCentral
23.
Zurück zum Zitat Tateshima S, Tanishita K, Hakata Y, Tanoue SY, Viñuela F (2009) Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation. J Neurosurg 111:22–27CrossRefPubMed Tateshima S, Tanishita K, Hakata Y, Tanoue SY, Viñuela F (2009) Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation. J Neurosurg 111:22–27CrossRefPubMed
24.
Zurück zum Zitat Vanninen R, Manninen H, Ronkainen A (2003) Broad-based intracranial aneurysms: thrombosis induced by stent placement. AJNR Am J Neuroradiol 24:263–266PubMed Vanninen R, Manninen H, Ronkainen A (2003) Broad-based intracranial aneurysms: thrombosis induced by stent placement. AJNR Am J Neuroradiol 24:263–266PubMed
25.
Zurück zum Zitat Molyneux AJ, Kerr RS, Yu LM, Clarke M, Sneade M, Yarnold JA, Sandercock P, International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2005) International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 366:809–817CrossRefPubMed Molyneux AJ, Kerr RS, Yu LM, Clarke M, Sneade M, Yarnold JA, Sandercock P, International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2005) International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 366:809–817CrossRefPubMed
26.
Zurück zum Zitat Ferns SP, Sprengers ME, van Rooij WJ et al (2009) Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates. Stroke 40:e523–e529CrossRefPubMed Ferns SP, Sprengers ME, van Rooij WJ et al (2009) Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates. Stroke 40:e523–e529CrossRefPubMed
27.
Zurück zum Zitat Ries T, Siemonsen S, Thomalla G, Grzyska U, Zeumer H, Fiehler J (2007) Long-term follow-up of cerebral aneurysms after endovascular therapy prediction and outcome of retreatment. AJNR Am J Neuroradiol 28:1755–1761CrossRefPubMed Ries T, Siemonsen S, Thomalla G, Grzyska U, Zeumer H, Fiehler J (2007) Long-term follow-up of cerebral aneurysms after endovascular therapy prediction and outcome of retreatment. AJNR Am J Neuroradiol 28:1755–1761CrossRefPubMed
28.
Zurück zum Zitat Chalouhi N, Jabbour P, Singhal S, Drueding R, Starke RM, Dalyai RT, Tjoumakaris S, Gonzalez LF, Dumont AS, Rosenwasser R, Randazzo CG (2013) Stent-assisted coiling of intracranial aneurysms: predictors of complications, recanalization, and outcome in 508 cases. Stroke 44:1348–1353CrossRefPubMed Chalouhi N, Jabbour P, Singhal S, Drueding R, Starke RM, Dalyai RT, Tjoumakaris S, Gonzalez LF, Dumont AS, Rosenwasser R, Randazzo CG (2013) Stent-assisted coiling of intracranial aneurysms: predictors of complications, recanalization, and outcome in 508 cases. Stroke 44:1348–1353CrossRefPubMed
29.
Zurück zum Zitat McLaughlin N, McArthur DL, Martin NA (2013) Use of stent-assisted coil embolization for the treatment of wide-necked aneurysms: a systematic review. Surg Neurol Int 4:43CrossRefPubMedPubMedCentral McLaughlin N, McArthur DL, Martin NA (2013) Use of stent-assisted coil embolization for the treatment of wide-necked aneurysms: a systematic review. Surg Neurol Int 4:43CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Handa A, Abdo G, Yilmaz H, Lovblad KO, Lylyk P, Rüfenacht DA (2004) Efficacy and limitations of the neuroform stent system for intracranial aneurysms. Interv Neuroradiol 10(Suppl 2):62–68CrossRefPubMedPubMedCentral Handa A, Abdo G, Yilmaz H, Lovblad KO, Lylyk P, Rüfenacht DA (2004) Efficacy and limitations of the neuroform stent system for intracranial aneurysms. Interv Neuroradiol 10(Suppl 2):62–68CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Fiorella D, Albuquerque FC, Woo H, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Neuroform in-stent stenosis: incidence, natural history, and treatment strategies. Neurosurgery 59:34–42CrossRefPubMed Fiorella D, Albuquerque FC, Woo H, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Neuroform in-stent stenosis: incidence, natural history, and treatment strategies. Neurosurgery 59:34–42CrossRefPubMed
33.
Zurück zum Zitat Mohlenbruch M, Herweh C, Behrens L et al (2014) The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy. Neuroradiology 56:389–395CrossRefPubMed Mohlenbruch M, Herweh C, Behrens L et al (2014) The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy. Neuroradiology 56:389–395CrossRefPubMed
34.
Zurück zum Zitat Poncyljusz W, Bilinski P, Safranow K et al (2015) The LVIS/LVIS Jr. stents in the treatment of wide-neck intracranial aneurysms: multicentre registry. J Neurointerv Surg 7:524–529CrossRefPubMed Poncyljusz W, Bilinski P, Safranow K et al (2015) The LVIS/LVIS Jr. stents in the treatment of wide-neck intracranial aneurysms: multicentre registry. J Neurointerv Surg 7:524–529CrossRefPubMed
35.
Zurück zum Zitat Shankar JJ, Quateen A, Weill A et al (2017) Canadian Registry of LVIS Jr for treatment of intracranial aneurysms (CaRLA). J Neurointerv Surg 9:849–853CrossRefPubMed Shankar JJ, Quateen A, Weill A et al (2017) Canadian Registry of LVIS Jr for treatment of intracranial aneurysms (CaRLA). J Neurointerv Surg 9:849–853CrossRefPubMed
36.
Zurück zum Zitat Fiorella D, Arthur A, Boulos A, Diaz O, Jabbour P, Pride L, Turk AS, Woo HH, Derdeyn C, Millar J, Clifton A (2016) Final results of the US humanitarian device exemption study of the low-profile visualized intraluminal support (LVIS) device. J Neurointerv Surg 8:894–897CrossRefPubMed Fiorella D, Arthur A, Boulos A, Diaz O, Jabbour P, Pride L, Turk AS, Woo HH, Derdeyn C, Millar J, Clifton A (2016) Final results of the US humanitarian device exemption study of the low-profile visualized intraluminal support (LVIS) device. J Neurointerv Surg 8:894–897CrossRefPubMed
37.
Zurück zum Zitat Feng Z, Fang Y, Xu Y, Hong B, Zhao W, Liu J, Huang Q (2016) The safety and efficacy of low profile visualized intraluminal support (LVIS) stents in assisting coil embolization of intracranial saccular aneurysms: a single center experience. J Neurointerv Surg 8:1192–1196CrossRefPubMed Feng Z, Fang Y, Xu Y, Hong B, Zhao W, Liu J, Huang Q (2016) The safety and efficacy of low profile visualized intraluminal support (LVIS) stents in assisting coil embolization of intracranial saccular aneurysms: a single center experience. J Neurointerv Surg 8:1192–1196CrossRefPubMed
38.
Zurück zum Zitat Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS, Fiorella DJ, Hoh BL, Howington JU, Jankowitz BT, Liebma N KM, Rai AT, Rodriguez-Mercado R, Siddiqui AH, Veznedaroglu E, Hopkins LN, Levy EI (2009) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39CrossRefPubMed Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS, Fiorella DJ, Hoh BL, Howington JU, Jankowitz BT, Liebma N KM, Rai AT, Rodriguez-Mercado R, Siddiqui AH, Veznedaroglu E, Hopkins LN, Levy EI (2009) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39CrossRefPubMed
39.
Zurück zum Zitat Fargen KM, Hoh BL, Welch BG, Pride GL, Lanzino G, Boulos AS, Carpenter JS, Rai A, Veznedaroglu E, Ringer A, Rodriguez-Mercado R, Kan P, Siddiqui A, Levy EI, Mocco J (2012) Long-term results of enterprise stent-assisted coiling of cerebral aneurysms. Neurosurgery 71:239–244CrossRefPubMed Fargen KM, Hoh BL, Welch BG, Pride GL, Lanzino G, Boulos AS, Carpenter JS, Rai A, Veznedaroglu E, Ringer A, Rodriguez-Mercado R, Kan P, Siddiqui A, Levy EI, Mocco J (2012) Long-term results of enterprise stent-assisted coiling of cerebral aneurysms. Neurosurgery 71:239–244CrossRefPubMed
40.
Zurück zum Zitat Kim SW, Sung SO, Chae KS, Park HS, Lee SH (2015) Clinical and angiographic outcomes of aneurysms treated with two self-expanding stent-assisted coiling systems: a comparison of solitaire AB and Enterprise VRD stents. J Cerebrovasc Endovasc Neurosurg 17:149–156CrossRefPubMedPubMedCentral Kim SW, Sung SO, Chae KS, Park HS, Lee SH (2015) Clinical and angiographic outcomes of aneurysms treated with two self-expanding stent-assisted coiling systems: a comparison of solitaire AB and Enterprise VRD stents. J Cerebrovasc Endovasc Neurosurg 17:149–156CrossRefPubMedPubMedCentral
41.
Zurück zum Zitat King B, Vaziri S, Singla A, Fargen KM, Mocco J (2015) Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature. J Neurointerv Surg 7:905–909CrossRefPubMed King B, Vaziri S, Singla A, Fargen KM, Mocco J (2015) Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature. J Neurointerv Surg 7:905–909CrossRefPubMed
42.
Zurück zum Zitat Gentric JC, Biondi A, Piotin M, Mounayer C, Lobotesis K, Bonafé A, Costalat V, French SENAT Investigators (2013) Safety and efficacy of neuroform for treatment of intracranial aneurysms: a prospective, consecutive, French multicentric study. AJNR Am J Neuroradiol 34:1203–1208CrossRefPubMed Gentric JC, Biondi A, Piotin M, Mounayer C, Lobotesis K, Bonafé A, Costalat V, French SENAT Investigators (2013) Safety and efficacy of neuroform for treatment of intracranial aneurysms: a prospective, consecutive, French multicentric study. AJNR Am J Neuroradiol 34:1203–1208CrossRefPubMed
43.
Zurück zum Zitat Kulcsar Z, Goricke SL, Gizewski ER et al (2013) Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates. Neuroradiology 55:459–465CrossRefPubMed Kulcsar Z, Goricke SL, Gizewski ER et al (2013) Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates. Neuroradiology 55:459–465CrossRefPubMed
44.
Zurück zum Zitat Maldonado IL, Machi P, Costalat V, Mura T, Bonafé A (2011) Neuroform stent-assisted coiling of unruptured intracranial aneurysms: short- and midterm results from a single-center experience with 68 patients. AJNR Am J Neuroradiol 32:131–136CrossRefPubMed Maldonado IL, Machi P, Costalat V, Mura T, Bonafé A (2011) Neuroform stent-assisted coiling of unruptured intracranial aneurysms: short- and midterm results from a single-center experience with 68 patients. AJNR Am J Neuroradiol 32:131–136CrossRefPubMed
45.
Zurück zum Zitat Durst CR, Khan P, Gaughen J, Patrie J, Starke RM, Conant P, Liu KC, Jensen ME, Evans AJ (2014) Direct comparison of Neuroform and Enterprise stents in the treatment of wide-necked intracranial aneurysms. Clin Radiol 69:e471–e476CrossRefPubMed Durst CR, Khan P, Gaughen J, Patrie J, Starke RM, Conant P, Liu KC, Jensen ME, Evans AJ (2014) Direct comparison of Neuroform and Enterprise stents in the treatment of wide-necked intracranial aneurysms. Clin Radiol 69:e471–e476CrossRefPubMed
46.
Zurück zum Zitat Ge H, Lv X, Yang X, He H, Jin H, Li Y (2016) LVIS stent versus Enterprise stent for the treatment of unruptured intracranial aneurysms. World Neurosurg 91:365–370CrossRefPubMed Ge H, Lv X, Yang X, He H, Jin H, Li Y (2016) LVIS stent versus Enterprise stent for the treatment of unruptured intracranial aneurysms. World Neurosurg 91:365–370CrossRefPubMed
47.
Zurück zum Zitat Dholakia R, Sadasivan C, Fiorella DJ, Woo HH, Lieber BB (2017) Hemodynamics of flow diverters. J Biomech Eng 139:021002CrossRef Dholakia R, Sadasivan C, Fiorella DJ, Woo HH, Lieber BB (2017) Hemodynamics of flow diverters. J Biomech Eng 139:021002CrossRef
48.
Zurück zum Zitat Wang C, Tian Z, Liu J, Jing L, Paliwal N, Wang S, Zhang Y, Xiang J, Siddiqui AH, Meng H, Yang X (2016) Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the pipeline device. J Transl Med 14:199CrossRefPubMedPubMedCentral Wang C, Tian Z, Liu J, Jing L, Paliwal N, Wang S, Zhang Y, Xiang J, Siddiqui AH, Meng H, Yang X (2016) Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the pipeline device. J Transl Med 14:199CrossRefPubMedPubMedCentral
49.
Zurück zum Zitat Palmaz JC (1993) Intravascular stents: tissue-stent interactions and design considerations. AJR Am J Roentgenol 160:613–618CrossRefPubMed Palmaz JC (1993) Intravascular stents: tissue-stent interactions and design considerations. AJR Am J Roentgenol 160:613–618CrossRefPubMed
50.
Zurück zum Zitat Seshadhri S, Janiga G, Beuing O et al (2011) Impact of stents and flow diverters on hemodynamics in idealized aneurysm models. J Biomech Eng 133:071005CrossRefPubMed Seshadhri S, Janiga G, Beuing O et al (2011) Impact of stents and flow diverters on hemodynamics in idealized aneurysm models. J Biomech Eng 133:071005CrossRefPubMed
51.
Zurück zum Zitat Kojima M, Irie K, Fukuda T, Hirose Y, Negoro M, Arai F (2012) The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters. Asian J Neurosurg 7:159–165CrossRefPubMedPubMedCentral Kojima M, Irie K, Fukuda T, Hirose Y, Negoro M, Arai F (2012) The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters. Asian J Neurosurg 7:159–165CrossRefPubMedPubMedCentral
52.
Zurück zum Zitat Li C, Wang S, Chen J, Yu H, Zhang Y, Jiang F, Mu S, Li H, Yang X (2012) Influence of hemodynamics on recanalization of totally occluded intracranial aneurysms: a patient-specific computational fluid dynamic simulation study. J Neurosurg 117:276–283CrossRefPubMed Li C, Wang S, Chen J, Yu H, Zhang Y, Jiang F, Mu S, Li H, Yang X (2012) Influence of hemodynamics on recanalization of totally occluded intracranial aneurysms: a patient-specific computational fluid dynamic simulation study. J Neurosurg 117:276–283CrossRefPubMed
53.
Zurück zum Zitat Luo B, Yang X, Wang S, Li H, Chen J, Yu H, Zhang Y, Zhang Y, Mu S, Liu Z, Ding G (2011) High shear stress and flow velocity in partially occluded aneurysms prone to recanalization. Stroke 42:745–753CrossRefPubMed Luo B, Yang X, Wang S, Li H, Chen J, Yu H, Zhang Y, Zhang Y, Mu S, Liu Z, Ding G (2011) High shear stress and flow velocity in partially occluded aneurysms prone to recanalization. Stroke 42:745–753CrossRefPubMed
54.
Zurück zum Zitat Jeon JP, Cho YD, Rhim JK, Park JJ, Cho WS, Kang HS, Kim JE, Han MH (2016) Effect of stenting on progressive occlusion of small unruptured saccular intracranial aneurysms with residual sac immediately after coil embolization: a propensity score analysis. J Neurointerv Surg 8:1025–1029CrossRefPubMed Jeon JP, Cho YD, Rhim JK, Park JJ, Cho WS, Kang HS, Kim JE, Han MH (2016) Effect of stenting on progressive occlusion of small unruptured saccular intracranial aneurysms with residual sac immediately after coil embolization: a propensity score analysis. J Neurointerv Surg 8:1025–1029CrossRefPubMed
55.
Zurück zum Zitat Cho YD, Kim KM, Lee WJ, Sohn CH, Kang HS, Kim JE, Han MH (2014) Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images. Korean J Radiol 15:161–168CrossRefPubMedPubMedCentral Cho YD, Kim KM, Lee WJ, Sohn CH, Kang HS, Kim JE, Han MH (2014) Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images. Korean J Radiol 15:161–168CrossRefPubMedPubMedCentral
56.
Zurück zum Zitat Choi JW, Roh HG, Moon WJ, Chun YI, Kang CH (2011) Optimization of MR parameters of 3D TOF-MRA for various intracranial stents at 3.0T MRI. Neurointervention 6:71–77CrossRefPubMedPubMedCentral Choi JW, Roh HG, Moon WJ, Chun YI, Kang CH (2011) Optimization of MR parameters of 3D TOF-MRA for various intracranial stents at 3.0T MRI. Neurointervention 6:71–77CrossRefPubMedPubMedCentral
57.
Zurück zum Zitat van Amerongen MJ, Boogaarts HD, de Vries J, Verbeek ALM, Meijer FJA, Prokop M, Bartels RHMA (2014) MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis. AJNR Am J Neuroradiol 35:1655–1661CrossRefPubMed van Amerongen MJ, Boogaarts HD, de Vries J, Verbeek ALM, Meijer FJA, Prokop M, Bartels RHMA (2014) MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis. AJNR Am J Neuroradiol 35:1655–1661CrossRefPubMed
Metadaten
Titel
Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?
verfasst von
Jeongjun Lee
Young Dae Cho
Dong Hyun Yoo
Hyun-Seung Kang
Won-Sang Cho
Jeong Eun Kim
Jusun Moon
Moon Hee Han
Publikationsdatum
20.04.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Neuroradiology / Ausgabe 7/2018
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-018-2022-4

Weitere Artikel der Ausgabe 7/2018

Neuroradiology 7/2018 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.