Abstract

Purpose

Some data indicate that first-generation highly cross-linked polyethylene (HXLPE) can oxidise in vivo and is associated with reduced mechanical properties. To overcome these limitations, a natural anti-oxidant vitamin E has been added to HXLPE to preserve the mechanical properties and decrease oxidative degradation whilst conserving high wear resistance. We hypothesised that after a minimal three years of follow-up the use of vitamin E-blended HXLPE would result in lower radiographic wear when compared with ultra-high molecular weight polyethylene (UHMWPE).

Methods

One hundred patients were randomised to receive hybrid total hip arthroplasty (THA) using a monoblock cementless acetabular component made either of UHMWPE or vitamin E-blended HXLPE. All other parameters were identical in both groups. Complete follow-up was available for 74 of these patients. Femoral head penetration was measured using a validated computer-assisted method.

Results

The median creep measured 0.111 mm (range, −0.576 – +0.444 mm) in the vitamin E-blended group versus 0.170 mm (range, −0.861 – +0.884 mm) in the UHMWPE group (difference of medians, 0.059; p = 0.046). The median steady state penetration rate was −0.008 mm/year (range, −0.88 – +0.64 mm/year) in the vitamin E-blended group versus 0.133 mm/year (range, −0.84 – +0.85 mm/year) in the UHMWPE group (difference of medians 0.141, p = 0.043).

Conclusions

This study demonstrated that femoral head penetration was lower when using vitamin E-blended HXLPE when compared with UHMWPE, with a steady-state penetration rate far below the osteolysis threshold. Longer-term follow-up is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening.
Literatur
1.
Zurück zum Zitat Warth LC, Callaghan JJ, Liu SS et al (2014) Thirty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old. A concise follow-up of previous reports. J Bone Joint Surg Am 96:1814–1819. doi:10.2106/JBJS.M.01573 CrossRefPubMed Warth LC, Callaghan JJ, Liu SS et al (2014) Thirty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old. A concise follow-up of previous reports. J Bone Joint Surg Am 96:1814–1819. doi:10.​2106/​JBJS.​M.​01573 CrossRefPubMed
2.
Zurück zum Zitat Berry DJ, Harmsen WS, Cabanela ME, Morrey BF (2002) Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am 84-A:171–177CrossRefPubMed Berry DJ, Harmsen WS, Cabanela ME, Morrey BF (2002) Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am 84-A:171–177CrossRefPubMed
3.
Zurück zum Zitat Muratoglu OK, Bragdon CR, O’Connor DO et al (2001) A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 16:149–160. doi:10.1054/arth.2001.20540 CrossRefPubMed Muratoglu OK, Bragdon CR, O’Connor DO et al (2001) A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 16:149–160. doi:10.​1054/​arth.​2001.​20540 CrossRefPubMed
4.
5.
Zurück zum Zitat Glyn-Jones S, Thomas GER, Garfjeld-Roberts P et al (2014) The John Charnley award: highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. Clin Orthop Relat Res 473:432–438. doi:10.1007/s11999-014-3735-2 CrossRefPubMedCentral Glyn-Jones S, Thomas GER, Garfjeld-Roberts P et al (2014) The John Charnley award: highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. Clin Orthop Relat Res 473:432–438. doi:10.​1007/​s11999-014-3735-2 CrossRefPubMedCentral
6.
Zurück zum Zitat Langlois J, Atlan F, Scemama C et al (2015) A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components. Bone Joint J 97-B:1458–1462. doi:10.1302/0301-620X.97B11.36219 CrossRefPubMed Langlois J, Atlan F, Scemama C et al (2015) A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components. Bone Joint J 97-B:1458–1462. doi:10.​1302/​0301-620X.​97B11.​36219 CrossRefPubMed
7.
Zurück zum Zitat Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661CrossRefPubMed Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661CrossRefPubMed
8.
11.
Zurück zum Zitat Rowell SL, Muratoglu OK (2016) Investigation of surgically retrieved, vitamin E-stabilized, crosslinked UHMWPE implants after short-term in vivo service. J Biomed Mater Res B Appl Biomater 104:1132-1140. doi:10.1002/jbm.b.33465 CrossRefPubMed Rowell SL, Muratoglu OK (2016) Investigation of surgically retrieved, vitamin E-stabilized, crosslinked UHMWPE implants after short-term in vivo service. J Biomed Mater Res B Appl Biomater 104:1132-1140. doi:10.​1002/​jbm.​b.​33465 CrossRefPubMed
12.
Zurück zum Zitat Salemyr M, Muren O, Ahl T et al (2015) Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial. Int Orthop 39:1499–1505. doi:10.1007/s00264-015-2680-3 CrossRefPubMed Salemyr M, Muren O, Ahl T et al (2015) Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial. Int Orthop 39:1499–1505. doi:10.​1007/​s00264-015-2680-3 CrossRefPubMed
13.
Zurück zum Zitat Shareghi B, Johanson P-E, Kärrholm J (2015) Femoral head penetration of vitamin E-infused highly cross-linked polyethylene liners: a randomized radiostereometric study of seventy hips followed for two years. J Bone Joint Surg Am 97:1366–1371. doi:10.2106/JBJS.N.00595 CrossRefPubMed Shareghi B, Johanson P-E, Kärrholm J (2015) Femoral head penetration of vitamin E-infused highly cross-linked polyethylene liners: a randomized radiostereometric study of seventy hips followed for two years. J Bone Joint Surg Am 97:1366–1371. doi:10.​2106/​JBJS.​N.​00595 CrossRefPubMed
14.
Zurück zum Zitat Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641CrossRefPubMed Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641CrossRefPubMed
16.
Zurück zum Zitat Merle D’Augibné R (1970) Numerical evaluation of hip function. Rev Chir Orthop Reparatrice Appar Mot 56:481–486PubMed Merle D’Augibné R (1970) Numerical evaluation of hip function. Rev Chir Orthop Reparatrice Appar Mot 56:481–486PubMed
17.
Zurück zum Zitat Yan Y, Chen H, Feng J et al (2016) Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles. Int Orthop. doi:10.1007/s00264-016-3217-0 Yan Y, Chen H, Feng J et al (2016) Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles. Int Orthop. doi:10.​1007/​s00264-016-3217-0
19.
Zurück zum Zitat Kuzyk PRT, Saccone M, Sprague S et al (2011) Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials. J Bone Joint Surg (Br) 93:593–600. doi:10.1302/0301-620X.93B5.25908 CrossRef Kuzyk PRT, Saccone M, Sprague S et al (2011) Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials. J Bone Joint Surg (Br) 93:593–600. doi:10.​1302/​0301-620X.​93B5.​25908 CrossRef
20.
Zurück zum Zitat Martell JM, Berkson E, Berger R, Jacobs J (2003) Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am 85-A:1111–1117CrossRefPubMed Martell JM, Berkson E, Berger R, Jacobs J (2003) Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am 85-A:1111–1117CrossRefPubMed
21.
Zurück zum Zitat Ihle M, Mai S, Pfluger D, Siebert W (2008) The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg (Br) 90:1284–1290. doi:10.1302/0301-620X.90B10.20274 CrossRef Ihle M, Mai S, Pfluger D, Siebert W (2008) The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg (Br) 90:1284–1290. doi:10.​1302/​0301-620X.​90B10.​20274 CrossRef
22.
Zurück zum Zitat Triclot P, Grosjean G, El Masri F et al (2007) A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg (Br) 89:1439–1445. doi:10.1302/0301-620X.89B11.19543 CrossRef Triclot P, Grosjean G, El Masri F et al (2007) A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg (Br) 89:1439–1445. doi:10.​1302/​0301-620X.​89B11.​19543 CrossRef
23.
Zurück zum Zitat Digas G, Kärrholm J, Thanner J et al (2004) The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res (429):6–16 Digas G, Kärrholm J, Thanner J et al (2004) The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res (429):6–16
24.
Metadaten
Titel
Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial
verfasst von
Caroline Scemama
Philippe Anract
Valérie Dumaine
Antoine Babinet
Jean Pierre Courpied
Moussa Hamadouche
Publikationsdatum
04.11.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 6/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3320-2

Weitere Artikel der Ausgabe 6/2017

International Orthopaedics 6/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.