Skip to main content
Erschienen in: International Ophthalmology 6/2018

23.10.2017 | Original Paper

“Double scleral tunnel in tandem” technique for glaucoma drainage tube implants

verfasst von: Dimitrios Brouzas, Maria Dettoraki, Konstantinos Andreanos, Nikolaos Nomikarios, Chryssanthi Koutsandrea, Marilita M. Moschos

Erschienen in: International Ophthalmology | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To describe a new technique of Ahmed glaucoma valve implantation in patients with refractory glaucoma and present the long-term results.

Methods

Twenty-eight eyes of 28 patients with refractory glaucoma participated in the study. “Double scleral tunnel in tandem” technique was used for glaucoma valve implantation in all patients. The technique consists of the formation of two scleral tunnels in tandem so as to completely cover the extraocular part of valve’s tube and facilitate a parallel to the iris placement of the intraocular part of the tube.

Results

Postoperative hypotony developed in two (7.1%) cases which resolved within 3 days in all cases. One (3.6%) eye manifested postoperative hyphema that resolved without complications within a week, and two (7.1%) cases presented with exposure of the tube. The average highest postoperative intraocular pressure (IOP) during the follow-up period was 19 mmHg (range 8–38 mmHg) without medications, and the average IOP at the last follow-up visit was 14.5 mmHg (range 8–22 mmHg). Additional treatment for IOP control was necessary in 11 (39.3%) cases. The average follow-up period was 60 months.

Conclusion

This novel technique was found to be easy to master, effective and with low cost and rate of complications.
Literatur
1.
Zurück zum Zitat Kiddee W, Trope G (2013) Glaucoma tube imaging using anterior segment optical coherence tomography in patients with opaque cornea. J Glaucoma 22:773–775CrossRef Kiddee W, Trope G (2013) Glaucoma tube imaging using anterior segment optical coherence tomography in patients with opaque cornea. J Glaucoma 22:773–775CrossRef
2.
Zurück zum Zitat Krebs DB, Liebmann JM, Ritch R, Spealer M (1992) Late infectious endophthalmitis from exposed glaucoma setons. Arch Ophthalmol 110:174–175CrossRef Krebs DB, Liebmann JM, Ritch R, Spealer M (1992) Late infectious endophthalmitis from exposed glaucoma setons. Arch Ophthalmol 110:174–175CrossRef
3.
Zurück zum Zitat Raviv T, Greenfield DS, Liebmann JM et al (1998) Pericardial patch graft in glaucoma implant Surgery. J Glaucoma 7:27–32CrossRef Raviv T, Greenfield DS, Liebmann JM et al (1998) Pericardial patch graft in glaucoma implant Surgery. J Glaucoma 7:27–32CrossRef
4.
Zurück zum Zitat Tanji TM, Lundy DC, Minckler DS et al (1996) Fascia lata patch graft in glaucoma tube surgery. Ophthalmology 103:1309–1312CrossRef Tanji TM, Lundy DC, Minckler DS et al (1996) Fascia lata patch graft in glaucoma tube surgery. Ophthalmology 103:1309–1312CrossRef
5.
Zurück zum Zitat Brandt JD (1993) Patch graft of dehydrated cadaveric dura mater for tube-shunt glaucoma surgery. Arch Ophthalmol 111:1436–1439CrossRef Brandt JD (1993) Patch graft of dehydrated cadaveric dura mater for tube-shunt glaucoma surgery. Arch Ophthalmol 111:1436–1439CrossRef
6.
Zurück zum Zitat Freedman J (1987) Scleral patch grafts with Molteno setons. Ophthalmic Surg 18:532–534PubMed Freedman J (1987) Scleral patch grafts with Molteno setons. Ophthalmic Surg 18:532–534PubMed
7.
Zurück zum Zitat Seiff SR, Chang JSJ, Hurt MH, Khayam-Bashi H (1994) Polymerase chain reaction identification of human immunodeficiency virus-I in preserved human sclera. Am J Ophthalmol 118:528–530CrossRef Seiff SR, Chang JSJ, Hurt MH, Khayam-Bashi H (1994) Polymerase chain reaction identification of human immunodeficiency virus-I in preserved human sclera. Am J Ophthalmol 118:528–530CrossRef
8.
Zurück zum Zitat Thandani V, Penar PL, Parthington J et al (1998) Creutzfeld–Jakob disease probably acquired from a cadaveric dura mater graft. J Neurosurg 69:766–769 Thandani V, Penar PL, Parthington J et al (1998) Creutzfeld–Jakob disease probably acquired from a cadaveric dura mater graft. J Neurosurg 69:766–769
9.
Zurück zum Zitat Brandt JD (1993) Patch grafts of dehydrated cadaveric dura mater for tube—shunt glaucoma surgery. Arch Ophthalmol 111:1436–1439CrossRef Brandt JD (1993) Patch grafts of dehydrated cadaveric dura mater for tube—shunt glaucoma surgery. Arch Ophthalmol 111:1436–1439CrossRef
10.
Zurück zum Zitat Ollila M, Falck A, Airaksinen PJ (2005) Placing the Molteno implant in a long scleral tunnel to prevent postoperative tube exposure. Acta Ophthalmol Scand 83:302–305CrossRef Ollila M, Falck A, Airaksinen PJ (2005) Placing the Molteno implant in a long scleral tunnel to prevent postoperative tube exposure. Acta Ophthalmol Scand 83:302–305CrossRef
11.
Zurück zum Zitat Chun YS, Kim KW, Kim JC (2013) Autologous tragal perichondrium patch graft for ahmed glaucoma valve tube exposure. J Glaucoma 22:e27–e30CrossRef Chun YS, Kim KW, Kim JC (2013) Autologous tragal perichondrium patch graft for ahmed glaucoma valve tube exposure. J Glaucoma 22:e27–e30CrossRef
12.
Zurück zum Zitat Tamçelik N, Sarici AM, Yetik H et al (2010) A novel surgical technique to prevent postoperative Ahmed valve tube exposure through conjunctiva: tenon advancement and duplication. Ophthalmic Surg Lasers Imaging 41:370–374CrossRef Tamçelik N, Sarici AM, Yetik H et al (2010) A novel surgical technique to prevent postoperative Ahmed valve tube exposure through conjunctiva: tenon advancement and duplication. Ophthalmic Surg Lasers Imaging 41:370–374CrossRef
13.
Zurück zum Zitat Tamcelik N, Ozkok A, Sarıcı AM et al (2013) Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma. Jpn J Ophthalmol 57(4):359–364CrossRef Tamcelik N, Ozkok A, Sarıcı AM et al (2013) Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma. Jpn J Ophthalmol 57(4):359–364CrossRef
14.
Zurück zum Zitat Kim D-H, Park C-K, Ahn M-D (2003) Clinical results of Ahmed valve implantation in the aspects of complications. J Korean Ophthalmol Soc 44:888–895 Kim D-H, Park C-K, Ahn M-D (2003) Clinical results of Ahmed valve implantation in the aspects of complications. J Korean Ophthalmol Soc 44:888–895
15.
Zurück zum Zitat Huang MC, Netland PA, Coleman AL et al (1999) Intermediate-term clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 127:27–33CrossRef Huang MC, Netland PA, Coleman AL et al (1999) Intermediate-term clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 127:27–33CrossRef
16.
Zurück zum Zitat Ayyala RS, Zurakowski D, Smith JA et al (1998) A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma. Ophthalmology 105:1968–1976CrossRef Ayyala RS, Zurakowski D, Smith JA et al (1998) A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma. Ophthalmology 105:1968–1976CrossRef
17.
Zurück zum Zitat Kil YG, Chung DY (1999) Ahmed glaucoma valve implant for neovascular glaucoma. J Korean Ophthalmol Soc 40:1950–1959 Kil YG, Chung DY (1999) Ahmed glaucoma valve implant for neovascular glaucoma. J Korean Ophthalmol Soc 40:1950–1959
18.
Zurück zum Zitat Ozdamar A, Aras C, Ustundag C et al (2001) Scleral tunnel for the implantation of glaucoma seton devices. Ophthalmic Surg Lasers 32:432–435PubMed Ozdamar A, Aras C, Ustundag C et al (2001) Scleral tunnel for the implantation of glaucoma seton devices. Ophthalmic Surg Lasers 32:432–435PubMed
19.
Zurück zum Zitat Kugu S, Erdogan G, Sevim MS, Ozerturk Y (2015) Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva. Semin Ophthalmol 30(1):1–5CrossRef Kugu S, Erdogan G, Sevim MS, Ozerturk Y (2015) Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva. Semin Ophthalmol 30(1):1–5CrossRef
20.
Zurück zum Zitat Stein JD, McCoy AN, Asrani S et al (2009) Surgical management of hypotony owing to overfiltration in eyes receiving glaucoma drainage devices. J Glaucoma 18:638–641CrossRef Stein JD, McCoy AN, Asrani S et al (2009) Surgical management of hypotony owing to overfiltration in eyes receiving glaucoma drainage devices. J Glaucoma 18:638–641CrossRef
21.
Zurück zum Zitat Coleman AL, Hill R, Wilson MR et al (1995) Initial clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 120:23–31CrossRef Coleman AL, Hill R, Wilson MR et al (1995) Initial clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 120:23–31CrossRef
22.
Zurück zum Zitat Smith M, Buys YM, Trope GE (2009) Second Ahmed valve insertion in the same eye. J Glaucoma 18:336–340CrossRef Smith M, Buys YM, Trope GE (2009) Second Ahmed valve insertion in the same eye. J Glaucoma 18:336–340CrossRef
23.
Zurück zum Zitat Robert M-C, Hamel P, Blondeau P, Lesk M (2013) Persistent leak after glaucoma aqueous shunt implantation. J Glaucoma 22:647–651CrossRef Robert M-C, Hamel P, Blondeau P, Lesk M (2013) Persistent leak after glaucoma aqueous shunt implantation. J Glaucoma 22:647–651CrossRef
24.
Zurück zum Zitat Park HY, Lee NY, Park CK (2009) Risk factors of shallow anterior chamber other than hypotony after Ahmed glaucoma valve implant. J Glaucoma 18:44–48CrossRef Park HY, Lee NY, Park CK (2009) Risk factors of shallow anterior chamber other than hypotony after Ahmed glaucoma valve implant. J Glaucoma 18:44–48CrossRef
25.
Zurück zum Zitat Smith M, Buys YM, Trope GE (2009) Replacement of Ahmed aqueous drainage devices in eyes with device-related complications. J Glaucoma 18:484–487CrossRef Smith M, Buys YM, Trope GE (2009) Replacement of Ahmed aqueous drainage devices in eyes with device-related complications. J Glaucoma 18:484–487CrossRef
26.
Zurück zum Zitat Sarkisian SR (2009) Tube shunt complications and their prevention. Curr Opin Ophthalmol 20:126–130CrossRef Sarkisian SR (2009) Tube shunt complications and their prevention. Curr Opin Ophthalmol 20:126–130CrossRef
27.
Zurück zum Zitat Minckler DS, Vedula SS, Li TJ et al (2006) Aqueous shunt for glaucoma. Cochrane Database Syst Rev 2:CD004918 Minckler DS, Vedula SS, Li TJ et al (2006) Aqueous shunt for glaucoma. Cochrane Database Syst Rev 2:CD004918
28.
Zurück zum Zitat Hong CH, Arosemena A, Zurakowski D et al (2005) Glaucoma drainage devices: a systemic literature review and current controversies. Surv Ophthalmol 50:48–60CrossRef Hong CH, Arosemena A, Zurakowski D et al (2005) Glaucoma drainage devices: a systemic literature review and current controversies. Surv Ophthalmol 50:48–60CrossRef
29.
Zurück zum Zitat Smith MF, Doyle JW, Ticmey JW Jr (2002) A comparison of glaucoma drainage implant tube coverage. J Glaucoma 11(2):143–147CrossRef Smith MF, Doyle JW, Ticmey JW Jr (2002) A comparison of glaucoma drainage implant tube coverage. J Glaucoma 11(2):143–147CrossRef
30.
Zurück zum Zitat Kurnaz E, Kubaloglu A, Yilmaz Y, Koytak A, Ozerturk Y (2005) The effect of adjunctive Mitomycin C in Ahmed glaucoma valve implantation. Eur J Ophthalmol 15(1):27–31CrossRef Kurnaz E, Kubaloglu A, Yilmaz Y, Koytak A, Ozerturk Y (2005) The effect of adjunctive Mitomycin C in Ahmed glaucoma valve implantation. Eur J Ophthalmol 15(1):27–31CrossRef
31.
Zurück zum Zitat Lankaranian D, Reis R, Henderer JD, Choe S, Moster MR (2008) Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome. J Glaucoma 17(1):48–51CrossRef Lankaranian D, Reis R, Henderer JD, Choe S, Moster MR (2008) Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome. J Glaucoma 17(1):48–51CrossRef
32.
Zurück zum Zitat Ekici F, Moster MR, Cvintal V, Hu WD, Waisbourd M (2015) Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft). Clin Ophthalmol 9:751–755CrossRef Ekici F, Moster MR, Cvintal V, Hu WD, Waisbourd M (2015) Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft). Clin Ophthalmol 9:751–755CrossRef
Metadaten
Titel
“Double scleral tunnel in tandem” technique for glaucoma drainage tube implants
verfasst von
Dimitrios Brouzas
Maria Dettoraki
Konstantinos Andreanos
Nikolaos Nomikarios
Chryssanthi Koutsandrea
Marilita M. Moschos
Publikationsdatum
23.10.2017
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 6/2018
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0733-x

Weitere Artikel der Ausgabe 6/2018

International Ophthalmology 6/2018 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.