Abstract

To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 × 1.5 × 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests. Dynamic pelvic floor MR imaging is feasible at 3.0 T. Our preliminary data indicate that evaluation of pelvic floor disease seems to be possible with 3.0 T equally well as compared to 1.5 T.
Literatur
1.
Zurück zum Zitat Goh V, Halligan S, Kaplan G, Healy JC, Bartram CI (2000) Dynamic MR imaging of the pelvic floor in asymptomatic subjects. AJR 174:661–666PubMed Goh V, Halligan S, Kaplan G, Healy JC, Bartram CI (2000) Dynamic MR imaging of the pelvic floor in asymptomatic subjects. AJR 174:661–666PubMed
2.
Zurück zum Zitat Kelvin FM, Maglinte DD, Hale DS, Benson JT (2000) Female pelvic organ prolpase: a comparison of triphasic dynamic MR Imaging and triphasic fluoroscopic cystocolpoproctography. AJR 174:81–88PubMed Kelvin FM, Maglinte DD, Hale DS, Benson JT (2000) Female pelvic organ prolpase: a comparison of triphasic dynamic MR Imaging and triphasic fluoroscopic cystocolpoproctography. AJR 174:81–88PubMed
3.
Zurück zum Zitat Lienemann A, Anthuber C, Baron A, Kohz P, Reiser M (1997) Dynamic MR colpocystorectography assessing pelvic-floor descent. Eur Radiol 7:1309–1317PubMedCrossRef Lienemann A, Anthuber C, Baron A, Kohz P, Reiser M (1997) Dynamic MR colpocystorectography assessing pelvic-floor descent. Eur Radiol 7:1309–1317PubMedCrossRef
4.
Zurück zum Zitat Morakkabati-Spitz N, Gieseke J, Kuhl C, Lutterbey G, von Falkenhausen M, Traeber F, Zivanovic O, Schild HH (2005) 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences. Eur Radiol 15:639–644PubMedCrossRef Morakkabati-Spitz N, Gieseke J, Kuhl C, Lutterbey G, von Falkenhausen M, Traeber F, Zivanovic O, Schild HH (2005) 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences. Eur Radiol 15:639–644PubMedCrossRef
5.
Zurück zum Zitat Morakkabati-Spitz N, Gieseke J, Kuhl C, Lutterbey G, von Falkenhausen M, Traeber F, Park-Simon TW, Zivanovic O, Schild HH (2006) MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time. Eur Radiol 16:634–641PubMedCrossRef Morakkabati-Spitz N, Gieseke J, Kuhl C, Lutterbey G, von Falkenhausen M, Traeber F, Park-Simon TW, Zivanovic O, Schild HH (2006) MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time. Eur Radiol 16:634–641PubMedCrossRef
6.
Zurück zum Zitat Morakkabati-Spitz N, Schild HH, Kuhl C, Lutterbey G, von Falkenhausen M, Traeber F, Gieseke J (2006) Female pelvis: MR Imaging at 3.0T with sensitivity encoding and flip-angle sweep technique. Radiology 241:538–545PubMedCrossRef Morakkabati-Spitz N, Schild HH, Kuhl C, Lutterbey G, von Falkenhausen M, Traeber F, Gieseke J (2006) Female pelvis: MR Imaging at 3.0T with sensitivity encoding and flip-angle sweep technique. Radiology 241:538–545PubMedCrossRef
7.
Zurück zum Zitat Femlee JP, Bernstein MA, Huston J (2002) Analysis of RF heating at 3.0 T. Proc 8th Meeting ISMRM, p 2002 Femlee JP, Bernstein MA, Huston J (2002) Analysis of RF heating at 3.0 T. Proc 8th Meeting ISMRM, p 2002
8.
Zurück zum Zitat Lin C, Bernstein M, Huston J, Fain S (2001) In-vivo and in-vitro measurements of T1 relaxation at 3.0 T. Proc 9th Meeting ISMRM, p 1391 Lin C, Bernstein M, Huston J, Fain S (2001) In-vivo and in-vitro measurements of T1 relaxation at 3.0 T. Proc 9th Meeting ISMRM, p 1391
9.
Zurück zum Zitat Hussain SM, van den Bos IC, Oliveto JM, Martin DR (2006) MR imaging of the female pelvis at 3T. Magn Reson Imaging Clin N Am 14:537–544PubMedCrossRef Hussain SM, van den Bos IC, Oliveto JM, Martin DR (2006) MR imaging of the female pelvis at 3T. Magn Reson Imaging Clin N Am 14:537–544PubMedCrossRef
10.
Zurück zum Zitat Kataoka M, Kido A, Koyama T, Isoda H, Umeoka S, Tamai K, Nakamoto Y, Maetani Y, Morisawa N, Saga T, Togashi K (2007) MRI of the female pelvis at 3T compared to 1.5T: evaluation on high-resolution T2-weighted and HASTE images. J Magn Reson Imaging 25:527–534PubMedCrossRef Kataoka M, Kido A, Koyama T, Isoda H, Umeoka S, Tamai K, Nakamoto Y, Maetani Y, Morisawa N, Saga T, Togashi K (2007) MRI of the female pelvis at 3T compared to 1.5T: evaluation on high-resolution T2-weighted and HASTE images. J Magn Reson Imaging 25:527–534PubMedCrossRef
11.
Zurück zum Zitat Kaul MG, Stork A, Bansmann PM, Nolte-Ernsting C, Lund GK, Weber C, Adam G (2004) Evaluation of a balanced steady-state free precession (TrueFISP) and k-space segmented Gradient echo sequence for 3D coronary MR angiography with navigator gating at 3 Tesla. Fortsch Röntgenstr 176:1560–1565CrossRef Kaul MG, Stork A, Bansmann PM, Nolte-Ernsting C, Lund GK, Weber C, Adam G (2004) Evaluation of a balanced steady-state free precession (TrueFISP) and k-space segmented Gradient echo sequence for 3D coronary MR angiography with navigator gating at 3 Tesla. Fortsch Röntgenstr 176:1560–1565CrossRef
12.
Zurück zum Zitat Tyler DJ, Hudsmith LE, Petersen SE, Francis JM, Weale P, Neubauer S, Clarke K, Robson MD (2006) Cardiac cine MR imaging at 3T: FLASH vs SSFP. Journal of Cardiovascular Magnetic Resonance 8:709–715PubMedCrossRef Tyler DJ, Hudsmith LE, Petersen SE, Francis JM, Weale P, Neubauer S, Clarke K, Robson MD (2006) Cardiac cine MR imaging at 3T: FLASH vs SSFP. Journal of Cardiovascular Magnetic Resonance 8:709–715PubMedCrossRef
13.
Zurück zum Zitat Li W, Storey P, Chen Q, Li BS, Prasad PV, Edelman RR (2004) Dark flow artefacts with steady-state free precession cine MR technique: Causes and implications for cardiac MR imaging. Radiology 230:569–575PubMedCrossRef Li W, Storey P, Chen Q, Li BS, Prasad PV, Edelman RR (2004) Dark flow artefacts with steady-state free precession cine MR technique: Causes and implications for cardiac MR imaging. Radiology 230:569–575PubMedCrossRef
14.
Zurück zum Zitat Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMed Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMed
15.
Zurück zum Zitat Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) Imaging in the steady state. Magnetic resonance imaging: physical principles and sequence design. Wiley, New York, NY, pp 472–482 Haacke EM, Brown RW, Thompson MR, Venkatesan R (1999) Imaging in the steady state. Magnetic resonance imaging: physical principles and sequence design. Wiley, New York, NY, pp 472–482
16.
Zurück zum Zitat Stuber M, Botnar RM, Fischer SE, Lamerichs R, Smink J, Harvey P, Manning WJ (2002) Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48:425–429PubMedCrossRef Stuber M, Botnar RM, Fischer SE, Lamerichs R, Smink J, Harvey P, Manning WJ (2002) Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48:425–429PubMedCrossRef
17.
Zurück zum Zitat Kuhl CK, Gieseke J, von Falkenhausen M, Textor J, Gernert S, Sonntag C, Schild HH (2005) Sensitivity Encoding for diffusionweighted MR imaging at 3.0 T: an intraindividual comparative study. Radiology 234:517–526PubMedCrossRef Kuhl CK, Gieseke J, von Falkenhausen M, Textor J, Gernert S, Sonntag C, Schild HH (2005) Sensitivity Encoding for diffusionweighted MR imaging at 3.0 T: an intraindividual comparative study. Radiology 234:517–526PubMedCrossRef
18.
Zurück zum Zitat Macura KJ, Genadry RR, Bluemke DA (2006) MR Imaging of the female urethra and supporting ligaments in assessment of urinary incontinence: spectrum of abnormalities. Radiographics 26:1135–1149PubMedCrossRef Macura KJ, Genadry RR, Bluemke DA (2006) MR Imaging of the female urethra and supporting ligaments in assessment of urinary incontinence: spectrum of abnormalities. Radiographics 26:1135–1149PubMedCrossRef
19.
Zurück zum Zitat Fielding JR (2002) Practical MR Imaging of female pelvic floor weakness. Radiographics 22:295–304PubMed Fielding JR (2002) Practical MR Imaging of female pelvic floor weakness. Radiographics 22:295–304PubMed
21.
Zurück zum Zitat Pannu HK, Kaufman HS, Cundiff GW, Genadry R, Bluemke DA, Fishman EK (2000) Dynamic MR Imaging of pelvic organ proplapse: spectrum of abnormalities. Radiographics 20:1567–1582PubMed Pannu HK, Kaufman HS, Cundiff GW, Genadry R, Bluemke DA, Fishman EK (2000) Dynamic MR Imaging of pelvic organ proplapse: spectrum of abnormalities. Radiographics 20:1567–1582PubMed
22.
Zurück zum Zitat Stoker J, Halligan S, Bartram CI (2001) Pelvic floor Imaging. Radiology 218:621–641PubMed Stoker J, Halligan S, Bartram CI (2001) Pelvic floor Imaging. Radiology 218:621–641PubMed
23.
Zurück zum Zitat Unterweger M, Marincek B, Gottstein-Aalame N, Debatin JF, Seifert B, Ochsenbein-Imhof N, Perucchini D, Kubik-Huch RA (2001) Ultrafast MR imaging of the pelvic floor. AJR 176:959–63PubMed Unterweger M, Marincek B, Gottstein-Aalame N, Debatin JF, Seifert B, Ochsenbein-Imhof N, Perucchini D, Kubik-Huch RA (2001) Ultrafast MR imaging of the pelvic floor. AJR 176:959–63PubMed
24.
Zurück zum Zitat Seynaeve R, Billiet I, Vossaert P, Verleyen P, Steegmans A (2006) MR imaging of the pelvic floor. JBR-BTR 89:182–189PubMed Seynaeve R, Billiet I, Vossaert P, Verleyen P, Steegmans A (2006) MR imaging of the pelvic floor. JBR-BTR 89:182–189PubMed
25.
Zurück zum Zitat Dietz HP, Haylen BT, Broome J (2001) Ultrasound in the quantification of female pelvic organ prolapse. Ultrasound Obstet Gynecol 18:511–514PubMedCrossRef Dietz HP, Haylen BT, Broome J (2001) Ultrasound in the quantification of female pelvic organ prolapse. Ultrasound Obstet Gynecol 18:511–514PubMedCrossRef
Metadaten
Titel
Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results
verfasst von
Nuschin Morakkabati-Spitz
Jürgen Gieseke
Winfried A. Willinek
Patrick J. Bastian
Bettina Schmitz
Frank Träber
Ursula Jaeger
Stefan C. Mueller
Hans H. Schild
Publikationsdatum
01.11.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 11/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1030-x

Weitere Artikel der Ausgabe 11/2008

European Radiology 11/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.