Skip to main content
main-content

19.10.2018 | Handsurgery | Ausgabe 12/2018

Archives of Orthopaedic and Trauma Surgery 12/2018

Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate

Zeitschrift:
Archives of Orthopaedic and Trauma Surgery > Ausgabe 12/2018
Autoren:
Stefan Quadlbauer, Ch. Pezzei, J. Jurkowitsch, R. Rosenauer, A. Pichler, S. Schättin, T. Hausner, M. Leixnering
Wichtige Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s00402-018-3051-5) contains supplementary material, which is available to authorized users.

Abstract

Introduction

Distal radius fractures (DRF) are the most common fractures of the upper extremities. The incidence is expected to continue rising in the next years due to the increased life expectancy. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF with a complication rate of 8–39% reported in the literature. Main aim of this study was to investigate the incidence of complications after DRF stabilization using palmar angular stable locking plate.

Methods

A retrospective medical records review conducted from January 2013 to December 2016 included a total of 392 patients with DRF, that were stabilized using palmar angular stable locking plate and showed a minimum follow-up of 3 months. The group comprised 259 female and 133 male patients with a mean follow-up interval of 11 months (range 3–52 months). All recorded complications were documented. Range of motion (ROM) in extension, flexion, supination, pronation, radial- and ulnar deviation of the last follow-up was noted. Age was divided into younger than 65 years (< 65 years) and older than 65 years (≥ 65 years). The primary, immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off.

Results

A total of 51 (13%) early and 17 late (4%) complications were recorded in 392 patients. The most common complications included carpal tunnel syndrome (3%), complex regional pain syndrome (3%) and loss of reduction (2%). Of the 68 complications, only 25 (6%) were directly related to the plate. 73% of all complications occurred in AO type C fractures. Patients without complications showed a significantly better ROM in extension, flexion, pronation and supination than patients with complications. No significant differences in incidence of complications, ROM or loss of reduction could be found between patients over and under 65 years of age. Gender and type of immobilization showed no significant influence on the complication rate.

Conclusions

Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment. In the majority of the cases a good clinical and radiological outcome with no complications was documented. Gender and type of immobilization had no impact on the complication rate and an age over 65 years is not associated with an increased risk for complications or restricted ROM.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Zusatzmaterial
Supplementary material 1 (DOC 92 KB)
402_2018_3051_MOESM1_ESM.doc
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 12/2018

Archives of Orthopaedic and Trauma Surgery 12/2018 Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Orthopädie und Unfallchirurgie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Orthopädie und Unfallchirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise