Abstract

The aim of this study was to evaluate the early functional outcome and survivorship of a bicompartmental knee arthroplasty implant (Journey-Deuce) in a cohort of patients with combined medial and patellofemoral degenerative osteoarthritis. Fifteen patients with a mean age of 57 years were followed up prospectively and evaluated with clinical examination, Oxford knee score and radiology imaging. Poor pain scores, concerns about the tibial fixation, early aseptic loosening of the tibial component and a revision rate of 60 % at a minimum follow-up of 54 months are reported. Implantation of this prosthesis was stopped at our institution well before the first revision due to an unfavourable early clinical response. This was further endorsed by an unacceptable revision rate. The outcome of the Journey-Deuce bicompartmental knee replacement was considerably worse than the published outcome of total knee replacement.
Literatur
1.
Zurück zum Zitat Ledingham J, Regan M, Jones A, Doherty M (1993) Radiographic patterns and associations of osteoarthritis of the knee in patients referred to hospital. Ann Rheum Dis 52:520–526CrossRefPubMedPubMedCentral Ledingham J, Regan M, Jones A, Doherty M (1993) Radiographic patterns and associations of osteoarthritis of the knee in patients referred to hospital. Ann Rheum Dis 52:520–526CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Rolston L, Bresch J, Engh G, Franz A, Kreuzer S, Nadaud M, Puri L, Wood D (2007) Bicompartmental knee arthroplasty: a bone-sparing, ligament-sparing, and minimally invasive alternative for active patients. Orthopedics 30(Suppl):70–73PubMed Rolston L, Bresch J, Engh G, Franz A, Kreuzer S, Nadaud M, Puri L, Wood D (2007) Bicompartmental knee arthroplasty: a bone-sparing, ligament-sparing, and minimally invasive alternative for active patients. Orthopedics 30(Suppl):70–73PubMed
3.
Zurück zum Zitat Rolston L, Siewert K (2009) Assessment of knee alignment after bicompartmental knee arthroplasty. J Arthroplast 24:1111–1114CrossRef Rolston L, Siewert K (2009) Assessment of knee alignment after bicompartmental knee arthroplasty. J Arthroplast 24:1111–1114CrossRef
4.
Zurück zum Zitat Wünschel M, Lo J, Dilger T, Wülker N, Müller O (2011) Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint. BMC Musculoskelet Disord 12:29CrossRefPubMedPubMedCentral Wünschel M, Lo J, Dilger T, Wülker N, Müller O (2011) Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint. BMC Musculoskelet Disord 12:29CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Morrison TA, Nyce JD, Macaulay WB, Geller JA (2011) Early adverse results with bicompartmental knee arthroplasty: a prospective cohort comparison to total knee arthroplasty. J Arthroplast 26(Suppl):35–39CrossRef Morrison TA, Nyce JD, Macaulay WB, Geller JA (2011) Early adverse results with bicompartmental knee arthroplasty: a prospective cohort comparison to total knee arthroplasty. J Arthroplast 26(Suppl):35–39CrossRef
6.
Zurück zum Zitat Muller M, Matziolos G, Falk R, Hommel H (2012) The bicompartmental knee joint prosthesis Journey Deuce: failure analysis and optimization strategies. Orthopade 41:894–904CrossRefPubMed Muller M, Matziolos G, Falk R, Hommel H (2012) The bicompartmental knee joint prosthesis Journey Deuce: failure analysis and optimization strategies. Orthopade 41:894–904CrossRefPubMed
7.
Zurück zum Zitat Palumbo BT, Henderson ER, Edwards PK, Burris RB, Gutiérrez S, Raterman SJ (2011) Initial experience of the Journey-Deuce bicompartmental knee prosthesis: a review of 36 cases. J Arthroplast 26(Suppl):40–45CrossRef Palumbo BT, Henderson ER, Edwards PK, Burris RB, Gutiérrez S, Raterman SJ (2011) Initial experience of the Journey-Deuce bicompartmental knee prosthesis: a review of 36 cases. J Arthroplast 26(Suppl):40–45CrossRef
8.
Zurück zum Zitat Kozinn S, Scott R (1989) Unicondylar knee arthroplasty. J Bone Joint Surg Am 71:145–150PubMed Kozinn S, Scott R (1989) Unicondylar knee arthroplasty. J Bone Joint Surg Am 71:145–150PubMed
9.
Zurück zum Zitat Mercier N, Wimsey S, Saragaglia D (2010) Long-term clinical results of the Oxford medial unicompartmental knee arthroplasty. Int Orthop 34:1137–1143CrossRefPubMed Mercier N, Wimsey S, Saragaglia D (2010) Long-term clinical results of the Oxford medial unicompartmental knee arthroplasty. Int Orthop 34:1137–1143CrossRefPubMed
10.
Zurück zum Zitat Lundberg-Jensen A, Kourakis AH, Rossen B, Kofoed H (2002) Radiolucency adjacent to the tibial component in total knee arthroplasty. Orthopedics 25:49–51PubMed Lundberg-Jensen A, Kourakis AH, Rossen B, Kofoed H (2002) Radiolucency adjacent to the tibial component in total knee arthroplasty. Orthopedics 25:49–51PubMed
11.
Zurück zum Zitat Colebatch AN, Hart DJ, Zhai G, Williams FM, Spector TD, Arden NK (2009) Effective measurement of knee alignment using AP knee radiographs. Knee 16:42–45CrossRefPubMed Colebatch AN, Hart DJ, Zhai G, Williams FM, Spector TD, Arden NK (2009) Effective measurement of knee alignment using AP knee radiographs. Knee 16:42–45CrossRefPubMed
13.
Zurück zum Zitat Scott CE, Eaton MJ, Nutton RW, Wade FA, Pankaj P, Evans SL (2013) Proximal tibial strain in medial unicompartmental knee replacements: a biomechanical study of implant design. Bone Joint J 95-B:1339–1347CrossRefPubMed Scott CE, Eaton MJ, Nutton RW, Wade FA, Pankaj P, Evans SL (2013) Proximal tibial strain in medial unicompartmental knee replacements: a biomechanical study of implant design. Bone Joint J 95-B:1339–1347CrossRefPubMed
Metadaten
Titel
Early failure with the Journey-Deuce bicompartmental knee arthroplasty
verfasst von
A. G. Dudhniwala
N. K. Rath
S. Joshy
M. C. Forster
S. P. White
Publikationsdatum
21.03.2016
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 5/2016
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-016-1760-4

Weitere Artikel der Ausgabe 5/2016

European Journal of Orthopaedic Surgery & Traumatology 5/2016 Zur Ausgabe

Original Article • LOWER LIMB - FRACTURES

Double locking plate fixation for femoral shaft nonunion

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.