Skip to main content
Erschienen in: International Orthopaedics 4/2011

01.04.2011 | Original Paper

Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study

verfasst von: David Campbell, Graham Mercer, Kjell G. Nilsson, Vanessa Wells, John R. Field, Stuart A. Callary

Erschienen in: International Orthopaedics | Ausgabe 4/2011

Einloggen, um Zugang zu erhalten

Abstract

Measurement of early stem subsidence can be used to predict the likelihood of long-term femoral component loosening and clinical failure. Data that examines the early migration pattern of clinically proven stems will provide clinicians with useful baseline data with which to compare new stem designs. This study was performed to evaluate the early migration pattern of a hydroxyapatite-coated press-fit femoral component that has been in use for over ten years. We enrolled 30 patients who underwent THA for osteoarthritis. The median age was 70 years (range, 55–80 years). Patients were clinically assessed using the Harris hip score. Radiostereometric analysis was used to evaluate stem migration at three to four days, six months, one year and two years. We observed a mean subsidence of 0.73 mm at six months, 0.62 mm at one year and 0.58 mm at two years and a mean retroversion of 1.82° at six months, 1.90° at one year and 1.59° at two years. This data suggests that subsidence is confined to the first six months after which there was no further subsidence. The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs.
Literatur
1.
Zurück zum Zitat Australian Orthopaedic Association National Joint Replacement Registry (2008) Annual Report. AOA, Adelaide Australian Orthopaedic Association National Joint Replacement Registry (2008) Annual Report. AOA, Adelaide
2.
Zurück zum Zitat Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89:780–785PubMedCrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89:780–785PubMedCrossRef
3.
Zurück zum Zitat Mazoochian F, Schrimpf FM, Kircher J, Mayer W, Hauptmann S, Fottner A, Muller PE, Pellengahr C, Jansson V (2007) Proximal loading of the femur leads to low subsidence rates: first clinical results of the CR-stem. Arch Orthop Trauma Surg 127:397–401PubMedCrossRef Mazoochian F, Schrimpf FM, Kircher J, Mayer W, Hauptmann S, Fottner A, Muller PE, Pellengahr C, Jansson V (2007) Proximal loading of the femur leads to low subsidence rates: first clinical results of the CR-stem. Arch Orthop Trauma Surg 127:397–401PubMedCrossRef
4.
Zurück zum Zitat Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH (2004) Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty 19:151–156PubMedCrossRef Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH (2004) Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty 19:151–156PubMedCrossRef
5.
Zurück zum Zitat Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V (2008) Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am 90:2160–2170PubMedCrossRef Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V (2008) Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am 90:2160–2170PubMedCrossRef
6.
Zurück zum Zitat Lubbeke A, Katz JN, Perneger TV, Hoffmeyer P (2007) Primary and revision hip arthroplasty: 5-year outcomes and influence of age and comorbidity. J Rheumatol 34:394–400PubMed Lubbeke A, Katz JN, Perneger TV, Hoffmeyer P (2007) Primary and revision hip arthroplasty: 5-year outcomes and influence of age and comorbidity. J Rheumatol 34:394–400PubMed
7.
Zurück zum Zitat Gheduzzi S, Miles AW (2007) A review of pre-clinical testing of femoral stem subsidence and comparison with clinical data. Proc Inst Mech Eng [H] 221:39–46 Gheduzzi S, Miles AW (2007) A review of pre-clinical testing of femoral stem subsidence and comparison with clinical data. Proc Inst Mech Eng [H] 221:39–46
8.
Zurück zum Zitat Froimson MI, Garino J, Machenaud A, Vidalain JP (2007) Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty 22:1–7PubMedCrossRef Froimson MI, Garino J, Machenaud A, Vidalain JP (2007) Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty 22:1–7PubMedCrossRef
9.
Zurück zum Zitat Karrholm J, Borssen B, Lowenhielm G, Snorrason F (1994) Does early micromotion of femoral stem prostheses matter? 4–7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76:912–917PubMed Karrholm J, Borssen B, Lowenhielm G, Snorrason F (1994) Does early micromotion of femoral stem prostheses matter? 4–7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76:912–917PubMed
10.
Zurück zum Zitat Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J (1997) Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res 94–110 Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J (1997) Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res 94–110
11.
Zurück zum Zitat Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66:418–424PubMedCrossRef Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66:418–424PubMedCrossRef
12.
Zurück zum Zitat Onsten I, Berzins A, Shott S, Sumner DR (2001) Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models. J Orthop Res 19:1162–1167PubMedCrossRef Onsten I, Berzins A, Shott S, Sumner DR (2001) Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models. J Orthop Res 19:1162–1167PubMedCrossRef
13.
Zurück zum Zitat Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty 22:125–129PubMedCrossRef Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty 22:125–129PubMedCrossRef
14.
Zurück zum Zitat Grant P, Aamodt A, Falch JA, Nordsletten L (2005) Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem. A randomized study with use of radiostereometry and bone densitometry. J Orthop Res 23:1280–1285PubMed Grant P, Aamodt A, Falch JA, Nordsletten L (2005) Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem. A randomized study with use of radiostereometry and bone densitometry. J Orthop Res 23:1280–1285PubMed
15.
Zurück zum Zitat Stefansdottir A, Franzen H, Johnsson R, Ornstein E, Sundberg M (2004) Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years. Acta Orthop Scand 75:408–414PubMedCrossRef Stefansdottir A, Franzen H, Johnsson R, Ornstein E, Sundberg M (2004) Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years. Acta Orthop Scand 75:408–414PubMedCrossRef
16.
Zurück zum Zitat Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI (2007) Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 89:1574–1580PubMedCrossRef Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI (2007) Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 89:1574–1580PubMedCrossRef
17.
Zurück zum Zitat Reikeras O, Gunderson RB (2003) Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8–12 years. Acta Orthop Scand 74:140–145PubMedCrossRef Reikeras O, Gunderson RB (2003) Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8–12 years. Acta Orthop Scand 74:140–145PubMedCrossRef
18.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed
19.
Zurück zum Zitat Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572PubMedCrossRef Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572PubMedCrossRef
20.
Zurück zum Zitat Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br 81:273–280PubMedCrossRef Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br 81:273–280PubMedCrossRef
21.
Zurück zum Zitat Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K (2003) The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand 74:525–530PubMedCrossRef Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K (2003) The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand 74:525–530PubMedCrossRef
22.
Zurück zum Zitat Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res 454:127–132PubMedCrossRef Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res 454:127–132PubMedCrossRef
23.
Zurück zum Zitat Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 22:1122–1129PubMedCrossRef Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 22:1122–1129PubMedCrossRef
24.
Zurück zum Zitat Kroell A, Beaule P, Krismer M, Behensky H, Stoeckl B, Biedermann R (2008) Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation. Int Orthop. doi:10.1007/s00264-008-0701-1 PubMed Kroell A, Beaule P, Krismer M, Behensky H, Stoeckl B, Biedermann R (2008) Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation. Int Orthop. doi:10.​1007/​s00264-008-0701-1 PubMed
Metadaten
Titel
Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
verfasst von
David Campbell
Graham Mercer
Kjell G. Nilsson
Vanessa Wells
John R. Field
Stuart A. Callary
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 4/2011
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0913-z

Weitere Artikel der Ausgabe 4/2011

International Orthopaedics 4/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.