Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study

verfasst von: Dietrich Pape, Olaf Lorbach, Christian Schmitz, Lüder C. Busch, Nicolien Van Giffen, Romain Seil, Dieter M. Kohn

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 2/2010

Einloggen, um Zugang zu erhalten

Abstract

Open-wedge high tibial osteotomy (HTO) is becoming increasingly popular for the treatment of varus gonarthrosis in the active patient. The various implants used in HTO differ with regard to its design, the fixation stability and osteotomy technique. It is assumed that the combination of a plate fixator with a biplanar, v-shaped osteotomy supports bone healing. So far, there are no biomechanical studies that quantify the stabilizing effect of a biplanar versus uniplanar osteotomy. We hypothesized that a significant increase in primary stability of bone-implant constructs is achieved when using a biplanar as opposed to a uniplanar osteotomy. Twenty-four fresh-frozen human tibiae were mounted in a metal cylinder, and open-wedge osteotomy (12 mm wedge size) was performed in a standardized fashion. Proximal and distal tibial segments were marked with tantalum markers of 0.8 mm diameter. Two different plates with locking screws were used for fixation: a short spacer plate (group 1, n = 12) and a plate fixator (group 2, n = 12). In six specimens of each group, a biplanar V-shaped osteotomy with a 110° angulated anterior cut behind the tuberosity parallel to the ventral tibial shaft axis was performed. In the remaining six specimens of each group, a simple uniplanar osteotomy was performed in an oblique fashion. Axial compression of the tibiae was performed using a material testing machine under standardized alignment of the loading axis. Load-controlled cyclical staircase loading tests were performed. The specimens were radiographed simultaneously in two planes together with a biplanar calibration cage in front of a film plane with and without load after each subcycle. Radiostereometry allowed for serial quantification of plastic and elastic micromotion at the osteotomy site reflecting the stability provided by the combination of implant and osteotomy technique. No significant additional stabilizing effect of a biplanar osteotomy in craniocaudal and mediolateral plane was found. However, additional stability was achieved in anteroposterior (AP) and all rotational planes in those specimens fixated with a short spacer plate. In this biomechanical set-up with axial load, the additional stabilizing effect of a biplanar osteotomy did not come into effect in the presence of a long and rigid plate fixator. However, biplanar osteotomy increased the fixation stability significantly in AP and rotational planes when a short spacer plate was used. Clinically, the biplanar osteotomy promotes bone healing regardless of the implant used. Biomechanically, biplanar osteotomy is advantageous for shorter plate designs to increase primary stability of the bone-implant construct.
Literatur
1.
Zurück zum Zitat Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14:291–300CrossRefPubMed Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14:291–300CrossRefPubMed
2.
Zurück zum Zitat Dahlberg G (1940) Statistical methods for medical and biological students. Interscience Publications, New York Dahlberg G (1940) Statistical methods for medical and biological students. Interscience Publications, New York
3.
Zurück zum Zitat Dorsey WO, Miller BS, Tadje JP, Bryant CR (2006) The stability of three commercially available implants used in medial opening wedge high tibial osteotomy. J Knee Surg 19:95–98PubMed Dorsey WO, Miller BS, Tadje JP, Bryant CR (2006) The stability of three commercially available implants used in medial opening wedge high tibial osteotomy. J Knee Surg 19:95–98PubMed
4.
Zurück zum Zitat Flamme CH, Kohn D, Kirsch L, Hurschler C (1999) Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119:450–455CrossRefPubMed Flamme CH, Kohn D, Kirsch L, Hurschler C (1999) Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119:450–455CrossRefPubMed
5.
Zurück zum Zitat Flierl S, Sabo D, Hornig K, Perlick L (1996) Open wedge high tibial osteotomy using fractioned drill osteotomy: a surgical modification that lowers the complication rate. Knee Surg Sports Traumatol Arthrosc 4:149–153CrossRefPubMed Flierl S, Sabo D, Hornig K, Perlick L (1996) Open wedge high tibial osteotomy using fractioned drill osteotomy: a surgical modification that lowers the complication rate. Knee Surg Sports Traumatol Arthrosc 4:149–153CrossRefPubMed
6.
Zurück zum Zitat Fowler P, Tan L, Brown G (2000) Medial opening wedge high tibial osteotomy: how I do it. Oper Tech Sports Med 8:32–38CrossRef Fowler P, Tan L, Brown G (2000) Medial opening wedge high tibial osteotomy: how I do it. Oper Tech Sports Med 8:32–38CrossRef
7.
Zurück zum Zitat Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
8.
Zurück zum Zitat Gaasbeek RD, Welsing RT, Verdonschot N, Rijnberg WJ, van Loon CJ, van Kampen A (2005) Accuracy and initial stability of open- and closed-wedge high tibial osteotomy: a cadaveric RSA study. Knee Surg Sports Traumatol Arthrosc 13:689–694CrossRefPubMed Gaasbeek RD, Welsing RT, Verdonschot N, Rijnberg WJ, van Loon CJ, van Kampen A (2005) Accuracy and initial stability of open- and closed-wedge high tibial osteotomy: a cadaveric RSA study. Knee Surg Sports Traumatol Arthrosc 13:689–694CrossRefPubMed
9.
Zurück zum Zitat Kellgren JH, Lawrence JS (1957) Radiological assessment of osteo-arthrosis. Ann Rheum Dis 16:494–502CrossRefPubMed Kellgren JH, Lawrence JS (1957) Radiological assessment of osteo-arthrosis. Ann Rheum Dis 16:494–502CrossRefPubMed
10.
Zurück zum Zitat Lobenhoffer P, De Simoni C, Staubli A (2002) Open-wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1:93–105 Lobenhoffer P, De Simoni C, Staubli A (2002) Open-wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1:93–105
11.
Zurück zum Zitat Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11:132–138PubMed Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11:132–138PubMed
12.
Zurück zum Zitat Miller BS, Dorsey WO, Bryant CR, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy. Am J Sports Med 33:1552–1557CrossRefPubMed Miller BS, Dorsey WO, Bryant CR, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy. Am J Sports Med 33:1552–1557CrossRefPubMed
13.
Zurück zum Zitat Pape D, Adam F, Seil R, Georg T, Kohn D (2005) Fixation stability following high tibial osteotomy: a radiostereometric analysis. J Knee Surg 18:108–115PubMed Pape D, Adam F, Seil R, Georg T, Kohn D (2005) Fixation stability following high tibial osteotomy: a radiostereometric analysis. J Knee Surg 18:108–115PubMed
14.
Zurück zum Zitat Pape D, Duchow J, Rupp S, Seil R, Kohn D (2006) Partial release of the superficial medial collateral ligament for open-wedge high tibial osteotomy. A human cadaver study evaluating medial joint opening by stress radiography. Knee Surg Sports Traumatol Arthrosc 14:141–148CrossRefPubMed Pape D, Duchow J, Rupp S, Seil R, Kohn D (2006) Partial release of the superficial medial collateral ligament for open-wedge high tibial osteotomy. A human cadaver study evaluating medial joint opening by stress radiography. Knee Surg Sports Traumatol Arthrosc 14:141–148CrossRefPubMed
15.
Zurück zum Zitat Selvik G (1978) A stereophotogrammetric system for the study of human movements. Scand J Rehabil Med Suppl 6:16–20PubMed Selvik G (1978) A stereophotogrammetric system for the study of human movements. Scand J Rehabil Med Suppl 6:16–20PubMed
16.
Zurück zum Zitat Selvik G, Alberius P, Aronson AS (1983) A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy. Acta Radiol 24:343–352 Selvik G, Alberius P, Aronson AS (1983) A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy. Acta Radiol 24:343–352
17.
Zurück zum Zitat Spahn G, Muckley T, Kahl E, Hofmann GO (2006) Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech 21:272–278CrossRef Spahn G, Muckley T, Kahl E, Hofmann GO (2006) Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech 21:272–278CrossRef
18.
Zurück zum Zitat Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate and the tomofix plate. Clin Biomech 19:944–950CrossRef Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate and the tomofix plate. Clin Biomech 19:944–950CrossRef
19.
Zurück zum Zitat Stuart MJ, Beachy AM, Grabowski JJ, An KN, Kaufman KR (1999) Biomechanical evaluation of a proximal tibial opening-wedge osteotomy plate. Am J Knee Surg 12:148–153PubMed Stuart MJ, Beachy AM, Grabowski JJ, An KN, Kaufman KR (1999) Biomechanical evaluation of a proximal tibial opening-wedge osteotomy plate. Am J Knee Surg 12:148–153PubMed
20.
Zurück zum Zitat Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572CrossRefPubMed Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572CrossRefPubMed
21.
Zurück zum Zitat Taylor WR, Heller MO, Bergmann G, Duda GN (2004) Tibio-femoral loading during human gait and stair climbing. J Orthop Res 22:625–629CrossRefPubMed Taylor WR, Heller MO, Bergmann G, Duda GN (2004) Tibio-femoral loading during human gait and stair climbing. J Orthop Res 22:625–629CrossRefPubMed
22.
Zurück zum Zitat Zhim F, Laflamme GY, Viens H, Laflamme GH, Yahia L (2006) Biomechanical stability of a retrotubercle opening-wedge high tibial osteotomy. J Knee Surg 19:28–321PubMed Zhim F, Laflamme GY, Viens H, Laflamme GH, Yahia L (2006) Biomechanical stability of a retrotubercle opening-wedge high tibial osteotomy. J Knee Surg 19:28–321PubMed
Metadaten
Titel
Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study
verfasst von
Dietrich Pape
Olaf Lorbach
Christian Schmitz
Lüder C. Busch
Nicolien Van Giffen
Romain Seil
Dieter M. Kohn
Publikationsdatum
01.02.2010
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 2/2010
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-009-0929-3

Weitere Artikel der Ausgabe 2/2010

Knee Surgery, Sports Traumatology, Arthroscopy 2/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.