Skip to main content
main-content

05.06.2018 | Original Article

Effect of circulatory system response to motor control in one-sided contractions

Zeitschrift:
European Journal of Applied Physiology
Autoren:
Terumasa Takahara, Hidetaka Yamaguchi, Kazutoshi Seki, Megumi Murata, Sho Onodera
Wichtige Hinweise
Communicated by Toshio Moritani.

Abstract

Purpose

The purpose of this study was to clarify the effect one-sided skeletal muscle contraction has on the circulatory system, spinal α-motoneuron excitability, and somatosensory-system-evoked potential.

Method

Nine healthy males maintained tension at 10, 20, and 30% of maximal voluntary contraction in static gripping in right hand. Heart rate, ln high frequency (HF), blood pressure (BP), F-wave, and somatosensory-evoked potential (SEP) were recorded during gripping task. BP, F-wave and SEP were recorded from left hand (contralateral side from contracting side).

Result and conclusion

There were significant main effects of contractions strength on heart rate (0%: 68.2 ± 6.8 bpm, 10%: 67.6 ± 7.4 bpm, 20%: 69.7 ± 8.5 bpm, 30%: 73.7 ± 9.3 bpm, F3.24=9.18, P < 0.01), systolic BP (0%: 127.7 ± 15 mmHg, 10%: 136.2 ± 13.5 mmHg, 20%: 136.2 ± 13.5 mmHg, 30%: 140.0 ± 17.1 mmHg, F3.24=23.93, P < 0.01), diastolic BP (0%: 69.3 ± 8.5 mmHg, 10%: 76.9 ± 11.1 mmHg, 20%: 79.9 ± 12.5 mmHg, 30%: 86.2 ± 14 mmHg, F3.24=17.09, P < 0.01), and F-wave appearance rate (0%: 29.7 ± 15.6%, 10%: 39.3 ± 20.5%, 20%: 47.5 ± 22.9%, 30%: 55.2 ± 21.8%, F3.24=14.04, P < 0.01). For the ln HF (0%: 5.9 ± 0.6, 10%: 6.3 ± 0.9, 20%: 6.3 ± 1.3, 30%: 6.0 ± 1.0, F3.24=2.43, P = 0.08), F-wave latency (0%: 29.6 ± 1.7 ms, 10%: 26.9 ± 2.1 ms, 20%: 26.5 ± 3.6 ms, 30%: 26.9 ± 2.3 ms, F3.24=0.11, P = 0.96), F-wave amplitude (0%: 2.0 ± 0.9%, 10%: 2.2 ± 0.9%, 20%: 2.3 ± 0.7%, 30%: 2.8 ± 1.1%, F3.24=2.80, P = 0.06), and N20 amplitude (0%: 3.9 ± 1.7 µV, 10%: 3.7 ± 1.7 µV, 20%: 3.9 ± 1.7 µV, 30%: 3.9 ± 1.8 µV, F3.24=0.61, P = 0.62), between the conditions. We conclude that regulation of the circulatory system and motor system has a limited effect on sensory input.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Arbeitsmedizin

09.07.2018 | Leitthema | Ausgabe 8/2018 Open Access

Ist Stillen in der Öffentlichkeit gesellschaftlich akzeptiert?

Erfahrungen und Einstellungen der Bevölkerung und stillender Mütter