Skip to main content
Erschienen in: Obesity Surgery 3/2021

Open Access 27.11.2020 | Original Contributions

Effect of Intraoperative Goal-Directed Fluid Management on Tissue Oxygen Tension in Obese Patients: a Randomized Controlled Trial

Erschienen in: Obesity Surgery | Ausgabe 3/2021

Abstract

Background

Perioperative subcutaneous tissue oxygen tension (PsqO2) is substantially reduced in obese surgical patients. Goal-directed fluid therapy optimizes cardiac performance and thus tissue perfusion and oxygen delivery. We therefore tested the hypothesis that intra- and postoperative PsqO2 is significantly reduced in obese patients undergoing standard fluid management compared to goal-directed fluid administration.

Methods

We randomly assigned 60 obese patients (BMI ≥ 30 kg/m2) undergoing laparoscopic bariatric surgery to receive either esophageal Doppler-guided goal-directed fluid management or conventional fluid treatment. Our primary outcome parameter was intra- and postoperative PsqO2 measured with a polarographic electrode in the subcutaneous tissue of the upper arm. A random effects linear regression model was used to analyze the effect of intervention.

Results

Overall, mean (± SD) PsqO2 was significantly higher in obese patients receiving goal-directed therapy compared to conventional fluid therapy (65.8 ± 28.0 mmHg vs. 53.7 ± 21.7, respectively; repeated measures design adjusted difference: 13.0 mmHg [95% CI 2.3 to 23.7; p = 0.017]). No effect was seen intraoperatively (69.6 ± 27.9 mmHg vs. 61.4 ± 28.8, difference: 9.7 mmHg [95% CI -3.8 to 23.2; p = 0.160]); however, goal-directed fluid management improved PsqO2 in the early postoperative phase (63.1 ± 27.9 mmHg vs. 48.4 ± 12.5, difference: 14.5 mmHg [95% CI 4.1 to 24.9; p = 0.006]). Intraoperative fluid requirements did not differ between the two groups.

Conclusions

Goal-directed fluid therapy improved subcutaneous tissue oxygenation in obese patients. This effect was more pronounced in the early postoperative period.

Clinical Trial Number and Registry

The study was registered at ClinicalTrials.​gov (NCT 01052519).
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Obesity is a major health care problem and its prevalence is rapidly increasing worldwide [1]. Laparoscopic bariatric surgery offers the most effective treatment to produce sustained weight loss and to resolve obesity-associated comorbidities [2]. Obesity is accompanied by significant pathophysiological conditions; therefore, obese patients require specific perioperative care [3]. Several guidelines and consensus statements for the anesthetic management of obese surgical patients have recently been developed [4, 5]. However, generally accepted evidence-based recommendations on fluid management are scarce [6]. Obesity is associated with body composition alterations mainly affecting the different fluid compartments. Absolute fluid volumes and thus cardiac output are increased [7], while the ratio of blood volume to total body weight decreases in a non-linear manner with an increase in body mass index (BMI) [8, 9]. Blood flow in the adipose tissue is inversely related to fat cell mass [10]. Thus, the estimation of fluid requirements to maintain normovolemia and hence optimized tissue perfusion and oxygenation remains challenging during the perioperative period. Inadequate tissue perfusion and hypoxia increase postoperative morbidity [11]. Subcutaneous tissue oxygenation is crucial for wound healing and serves as a major predictive factor for the development of surgical wound infections [12, 13]. In obese patients undergoing anesthesia and surgery, subcutaneous tissue oxygen tension (PsqO2) was substantially reduced compared to non-obese patients, and even supplemental oxygen failed to increase tissue oxygen availability [14, 15]. Beside factors such as the capillary rarefication of adipose tissue [16] and the increased sympathetic activity with subsequent alpha-adrenergic vasoconstriction [17], a suboptimal intravascular volume status might also have contributed to the observed tissue hypoxia. At present, individualized goal-directed fluid therapy (GDFT) is the most effective way to optimize cardiac performance and to improve oxygen delivery in the perioperative period [13]. We therefore evaluated perioperative subcutaneous tissue oxygenation in obese patients receiving GDFT compared to conventional fluid treatment. More specifically, we tested the hypothesis that intra- and postoperative PsqO2 is significantly reduced in obese patients undergoing conventional fluid management (control group) compared to goal-directed fluid administration.

Methods

Study Design and Objectives

This investigator-initiated, prospective, randomized, controlled trial was conducted at a single center (Medical University of Vienna, Austria). The study was approved by the ethics committee of the Medical University Vienna and was performed in compliance with the Good Clinical Practice guidelines and the principles of the Declaration of Helsinki. The study was registered at ClinicalTrials.​gov (NCT 01052519) and reported in accordance with the recommendations in the CONSORT statement [18].

Study Population

In total, 60 patients aged 18–65 years with a BMI ≥ 30 kg/m2 scheduled for laparoscopic gastric bypass surgery were recruited for this study. Exclusion criteria included decompensated heart failure, documented coronary or peripheral artery disease, renal insufficiency, severe chronic obstructive disease, and insulin-dependent diabetes mellitus. Furthermore, we did not include patients with obstructive sleep apnea syndrome requiring continuous positive airway pressure overnight. We also excluded patients with any known aortic or esophageal abnormalities, other than gastro-esophageal reflux.

Randomization

After induction of general anesthesia and insertion of the esophageal probe for Doppler monitoring, obese patients were randomized into either the goal-directed obese group (GDFT) or the control group (CG) using a random number generator in sealed envelopes.

Anesthetic Management

Prior to surgery, 500 mL of lactated Ringer’s solution (LR) was administered intravenously. Following a preoxygenation period of 5 min with 18 L oxygen flow, general anesthesia was induced with fentanyl (2–3 μg kg−1 ideal body weight), propofol (2–3 mg kg−1 total body weight), and rocuronium (0.9 mg kg−1 ideal body weight), and direct view laryngoscopy was performed in the ramped position. After induction of anesthesia, a 20G cannula was inserted into a radial artery. To standardize tissue oxygen availability in all patients, inspired oxygen fraction (FiO2) was adapted during the intraoperative period to maintain arterial oxygen pressure (PaO2) near 250 mmHg. Patients were mechanically ventilated with a tidal volume of 6–8 mL kg−1 ideal body weight at a rate sufficient to maintain end-tidal carbon dioxide partial pressure (etCO2) near 40 mmHg. Positive end-expiratory pressure was set between 7 and 10 cm H2O, and peak airway pressure was kept below 30 cm H2O. Subsequently, general anesthesia was maintained with sevoflurane in a carrier gas of inspired oxygen and air. A supplemental bolus dose of fentanyl (100 μg) was given when heart rate or arterial pressure exceeded 120% of the baseline value. Repeated doses of rocuronium were administered as deemed necessary.
Upper-body forced air warming (Bair Hugger system, 3M, MN) was used to keep patients normothermic, while local warming of the measurement site was strictly avoided. After induction, all patients were placed in the 25° reverse Trendelenburg position for the subsequent laparoscopic procedure. Capnoperitoneum was routinely maintained at 15 mmHg in obese patients. At the end of the procedure, following complete reversal of neuromuscular blockade, all patients were extubated in the semi recumbent position following manual hyperinflation and transferred to the postoperative anesthesia care unit (PACU).

Intraoperative Fluid Management

After induction of anesthesia, a lubricated esophageal Doppler probe (CardioQ, Deltex Medical Group PLC, UK) was inserted orally into the esophagus and advanced to the mid-thoracic level to monitor stroke volume (SV) and corrected flow time (FTc). Measurements started as soon as an optimum descending aortic waveform was obtained and were continued during surgery whenever possible. During placement of the calibration bougie for the surgical procedure, the probe was retracted and Doppler monitoring was discontinued for approximately two measurements.
In the GDFT group, fluid management was strictly controlled. A maintenance rate of 2 mL kg−1 h−1 of crystalloid normalized to ideal body weight, which was calculated according to the Robinson formula [19], was administered throughout the entire study period. Additional fluid was administered based on a previously published and validated algorithm [20]. In short, patients received additional boluses of 250 mL LR guided by esophageal Doppler monitoring in order to achieve stroke volume optimization. Fluid responsiveness was defined as an increase in stroke volume > 10%. Boluses were given as long as fluid responsiveness was verified. If SV increased ≤ 10% after bolus administration, the patient was considered “non-responsive” and received another fluid bolus only when SV decreased > 10% from the most recent baseline.
The CG received fluid management according to the attending anesthesiologist. In this case, the esophageal Doppler monitor was turned away from the anesthesia care provider and the screen was covered with an opaque card. A researcher not involved in fluid management collected the displayed variables during surgery. In case of a mean arterial pressure < 65 mmHg and, as available, no Doppler-based signs of hypovolemia, intravenous vasopressors were administered at the discretion of the attending anesthesiologist.

Postoperative Management

Patients were closely observed over 2 hours in the PACU after the surgical procedure. Postoperative pain was treated with intravenous fractionated piritramid and metamizol 1000 mg according to patients’ requirements by clinicians not involved in the study. Oxygen was delivered via a facemask to maintain PaO2 near 150 mmHg in the post-anesthesia care unit. In addition to the maintenance rate, crystalloid was given as deemed necessary by attending anesthesiologists.

Measurements

Demographic and morphometric data, American Society of Anesthesiologists (ASA) physical status scores, comorbidities, and preoperative hemoglobin values were collected. We recorded routine variables, including duration of anesthesia and surgery, fluid balance data, hemodynamic- and Doppler-derived parameters, and anesthesia specific data. We measured intraoperative core temperature at the distal esophagus and forearm to fingertip skin temperature gradients with cutaneous Mon-a-Therm thermocouples as an indicator for arterio-venous shunt flow. Skin temperature gradients ≥ 0 °C were considered vasoconstriction [21]. Arterial blood gas analysis was performed as necessary to maintain PaO2 at the predetermined levels. Moreover, during their PACU stay, patients were asked to rate pain and nausea at 30-min intervals using a visual analog scale.

Subcutaneous Tissue Oxygen Tension (PsqO2)

Our primary outcome parameter was intra- and postoperative subcutaneous tissue oxygen tension (PsqO2) measured from a surrogate wound in the upper arm. After induction of anesthesia, an implantable Silastic tonometer was inserted into the subcutaneous tissue of the right lateral upper arm for the measurement of PsqO2 and tissue temperature (TsqO2). Each tonometer consisted of 15 cm of tubing filled with hypoxic saline, with 10 cm of the tubing being tunneled subcutaneously. A Clark-type oxygen sensor and thermistor (Licox, Gesellschaft für Medizinische Sondensysteme, GmbH, Kiel, Germany) were inserted into the subcutaneous portion of both tonometers as previously described [22]. The disposable micro-probes were connected to a digital bedside monitor (Licox, Gesellschaft für Medizinische Sondensysteme, GmbH, Kiel, Germany), which displayed tissue oxygen and temperature values continuously. Recording of PsqO2 started after an equilibration time of 30 min and was continued during the intraoperative and postoperative study period. The probes were removed from the patient before transfer to the surgical ward.
In vitro accuracy of the oxygen sensors is ± 3 mmHg for the range from 0 to 100 mmHg, and ± 5% for 100 to 360 mmHg (in a water bath at 37 °C). Temperature sensitivity is 0.25%/°C, thermistors were incorporated into the probes, and temperature compensation was included in the PsqO2 calculations. Oxygen sensor calibration remains stable (within 8% of baseline value for room air) in vivo for at least 8 h. The electrodes are individually factory-calibrated, but calibration was confirmed by exposing the electrode to room air (ambient PO2 of 154 mmHg); in all cases, measurements in air were within 10% of 154 mmHg. To exclude a significant drift of the oxygen sensor, probes were again exposed to room air after each investigation; none differed by more than 10% from baseline values.

Sample Size Consideration and Statistical Analysis

Sample size consideration was based on previous studies evaluating the effect of obesity on tissue oxygen tension [14, 15]. Based on the assumption of an average difference in PsqO2 of approximately 15 mmHg between the BMI groups, and an average standard deviation of 15 mmHg, 27 patients in each group would be required. This is based on the acceptance of a type I error risk of 5% and a type II error risk of 10% (power 90%). We therefore included 30 patients in each group.
We presented metric data as mean ± between subject standard deviation; not normally distributed data were presented as median and interquartile range (IQR); categorized variables are presented as absolute count and relative frequency. The data analysis follows the intention-to-treat principle. The primary outcome was the metric variable PsqO2, which we assumed to be normally distributed. To allow for a variable number of repeated measurements, we used random effects linear regression with treatment group allocation as the explaining covariable to estimate the difference in the outcome between the two groups. We present the effect of the intervention as the mean difference between the intervention group and control group together with a 95% confidence interval. We present separate estimates for the intraoperative phase as well as for the postoperative phase. A sensitivity analysis with the naturally log transformed PsqO2 as the outcome variable was performed to investigate the normality assumption. We analyzed metric secondary outcomes using ordinary linear regression or t tests with treatment group allocation as the explaining covariable. Binary secondary outcomes were analyzed using logistic regression models. For secondary outcomes with repeated measures, we used random effects regression as detailed above. To investigate randomization success, we tabulated baseline characteristics and compared these formally between the treatment groups. For metric variables, we used the independent sample t test or a Mann-Whitney U test; for categorized variables, we used the Fisher’s exact test. For data management and analysis, we used MS Excel and Stata 14.0 (Stata Corp, College Station, TX). Generally, a two-sided p value < 0.05 was considered statistically significant.

Results

In total, 60 patients were included and randomized to receive either goal-directed or conventional fluid treatment (Fig. 1). All included patients received the allocated intervention according to the protocol; there were no cases in which the assigned treatment was discontinued. Demographic and baseline characteristics of included patients are shown in Table 1; there were no significant differences between the two groups.
Table 1
Demographic and baseline patient characteristics
Parameters
GDFT group (n = 30)
Control group (n = 30)
P value
Baseline data
  Age (years), mean (SD)
38 (11)
39 (11)
0.760
  Female sex, n (%)
24 (80)
25 (83)
1.000
  Weight (cm), mean (SD)
128 (17)
131 (21)
0.545
  Height (kg), mean (SD)
168 (8)
167 (10)
0.817
  BMI (kg m−2), mean (SD)
45.1 (3.9)
45.8 (6.3)
0.609
  ASA score, n (%)
0.301
  1
3 (10)
4 (13)
 
  2
24 (80)
19 (63)
  3
3 (10)
7 (23)
Comorbidities
  Arterial hypertension, n (%)
7 (23)
13 (43)
0.170
  NIDDM, n (%)
3 (10)
8 (27)
0.181
  Smoker, n (%)
16 (53)
9 (30)
0.115
  Hb preoperative (g dl−1), mean (SD)
13.5 (1.3)
13.6 (1.1)
0.628
Data are expressed as mean (SD), if not otherwise specified
GDFT, goal-directed fluid therapy; SD, standard deviation; BMI, body mass index; ASA, American Society of Anesthesiologists; NIDDM, non-insulin-dependent diabetes mellitus; Hb, hemoglobin
Continuous data in groups were compared using t test; discrete data were compared using chi-square test

Subcutaneous Tissue Oxygen Tension

Measurement of intra- and postoperative subcutaneous tissue oxygen tension was performed in all of the included patients. Overall, mean (± SD) PsqO2 was significantly higher in obese patients receiving goal-directed therapy compared to conventional fluid therapy (65.8 ± 28.0 mmHg vs. 53.7 ± 21.7, respectively; repeated measures design adjusted difference: 13.0 mmHg [95% CI 2.3 to 23.7; p = 0.017]). The intraoperative PsqO2 showed no significant difference (69.6 ± 27.9 mmHg vs. 61.4 ± 28.8, repeated measures design adjusted difference: 9.7 mmHg [95% CI -3.8 to 23.2; p = 0.160]). However, in the postoperative period, PsqO2 improved significantly in the GDFT group (63.1 ± 27.9 mmHg vs. 48.4 ± 12.5, repeated measures design adjusted difference: 14.5 mmHg [95% CI 4.1 to 24.9; p = 0.006]) (Fig. 2).

Intraoperative Period

Duration of anesthesia and surgery was comparable between the groups. It is also noteworthy that fluid requirements did not differ between the two groups (for details, see Table 2). Anesthetic management was comparable between the groups. Patients assigned to goal-directed fluid therapy received a median dose of 0 mg (IQR 0 to 0.12) phenylephrine while patients in the control group received 0 mg (IQR 0 to 0.08) phenylephrine (p = 0.478) during surgery. Furthermore, there was no effect of vasopressor use on overall tissue oxygenation (coefficient: − 7.7 mmHg [95% CI − 34.1 to 18.7; p = 0.568]). As expected, mean (± SD) corrected flow time (FTc) was significantly higher in the goal-directed group compared to standard treatment (357 ± 33 msec vs. 339 ± 42, respectively; repeated measures design adjusted difference: 16 msec [95% CI 2 to 30; p = 0.029]). All other hemodynamics and Doppler-derived parameters (mean arterial pressure, heart rate, stroke volume, cardiac index, and cardiac output) did not differ between goal-directed and conventional fluid management in obese patients (Table 2, Fig. 3). Intraoperative core temperature was interestingly minimal different between the two groups (36.2 ± 0.5 °C vs. 36.5 ± 0.5, repeated measures design adjusted difference: − 0.3 °C [95% CI − 0.5 to − 0; p = 0.017]), while skin temperature gradients showed no significant difference (Table 2).
Table 2
Intraoperative management
Parameters
GDFT group (n = 30)
Control group (n = 30)
Estimate (95% CI)
Duration
  Anesthesia (min), mean (SD)
156 (39)
162 (39)
6 (− 14 to 26)
  Surgery (min), mean (SD)
110 (33)
106 (41)
− 4 (− 24 to 15)
Fluid management
  Crystalloid (mL), mean (SD)
1357 (393)
1363 (434)
− 6 (− 220 to 208)
  Bolus (count), mean (SD)
4.3 (1.3)
0 (0)
4.3 (3.8–4.8)*
Hemodynamic and Doppler-derived parameters
  Mean arterial blood pressure (mmHg), mean (SD)
80 (15)
80 (14)
0 (− 5 to 6)
  Heart rate (beats min−1), mean (SD)
75 (14)
75 (14)
0 (− 6 to 6)
  Corrected flow time (msec), mean (SD)
357 (33)
339 (42)
16 (2 to 30)*
  Stroke volume (mL), mean (SD)
81 (21)
74 (24)
6 (− 3 to 15)
  Cardiac index (L min−1 m−2), mean (SD)
2.6 (0.7)
2.4 (0.9)
0.1 (− 0.2 to 0.5)
  Cardiac output (L min−1), mean (SD)
5.9 (1.7)
5.4 (1.9)
0.4 (− 0.4 to 1.2)
Anesthetic management
  Fraction of inspired oxygen (vol%), mean (SD)
72 (15)
69 (15)
3 (− 4 to 9)
  Et Sevoflurane (vol%), mean (SD)
2.0 (0.4)
2.0 (0.4)
0 (− 0.1 to 0.2)
  Fentanyl (μg), mean (SD)
583159)
575 (230)
− 8 (− 111 to 94)
  Phenylephrine (yes/no), n (%)
13 (43)
10 (33)
1.5 (0.5 to 4.4)§
Blood gas analysis and temperature
  PaO2 (mmHg), mean (SD)
229 (78)
236 (79)
− 8 (− 34 to 19)
  PaCo2 (mmHg), mean (SD)
44.7 (4.8)
43.7 (5.2)
1.1 (− 0.6 to 2.7)
  TsqO2 (°C), mean (SD)
32.5 (1.6)
32.5 (1.4)
0 (− 0.7 to 0.7)
  Core temperature (°C), mean (SD)
36.2 (0.5)
36.5 (0.5)
− 0.3 (− 0.5 to 0)*
  Skin temperature gradient (°C), mean (SD)
− 2.5 (1.8)
− 3.0 (1.8)
0.5 (− 0.2 to 1.3)
Data are expressed as mean (SD) or median, if not otherwise specified
SD, standard deviation; PaO2, arterial oxygen partial pressure; PaCO2, arterial carbon dioxide partial pressure; TsqO2, subcutaneous tissue temperature; skin temperature gradient, forearm-fingertip skin temperature; CI, confidence interval
For statistical comparisons, a random effects GLS regression model was used
Difference between study groups if not otherwise defined
§Odds ratio
*p < 0.05

Postoperative Period

During the postoperative period, no difference was seen regarding hemodynamic parameters (mean arterial pressure, heart rate) or temperature parameters (skin temperature gradient, TsqO2) (Table 3). None of our patients required vasopressor therapy during the postoperative period. However, intraoperative goal-directed fluid management improved PsqO2 in the postoperative period (63.1 ± 27.9 mmHg vs. 48.4 ± 12.5, repeated measures design adjusted difference: 14.5 mmHg [95% CI 4.1 to 24.9; p = 0.006]) (Fig. 2).
Table 3
Postoperative management
Parameters
GDFT group (n = 30)
Control group (n = 30)
Estimate (95% CI)
Hemodynamic parameters
  Mean arterial blood pressure (mmHg), mean (SD)
107 (14)
108 (12)
− 1 (− 7 to 5)
  Heart rate (beats min−1), mean (SD)
75 (12)
75 (13)
0 (− 6 to 6)
Blood gas analysis and temperature
  PaO2 (mmHg), mean (SD)
141 (44)
142 (45)
0 (− 18 to 17)
  PaCo2 (mmHg), mean (SD)
42.4 (4.5)
42.2 (4.9)
0 (− 2.2 to 1.8)
  TsqO2 (°C), mean (SD)
32.5 (1.5)
32.6 (1.6)
0 (− 0.6 to 0.6)
  Skin temperature gradient (°C), mean (SD)
− 0.5 (2.6)
− 0.2 (2.5)
− 0.2 (− 1.3 to 0.9)
Postoperative course
  Urin (mL), mean (SD)
192 (207)
259 (245)
68 (− 49 to 185)
  VAS, mean (SD)
3 (3)
3 (2)
0 (− 1 to 1)
  PONV (yes/no), n (%)
19 (63)
19 (63)
0 (0 to 3)§
  Antiemetic treatment (yes/no), n (%)
17 (57)
17 (57)
1 (0 to 3)§
  Piritramid (mg), mean (SD)
9 (6)
8 (6)
− 1 (− 4 to 2)
Data are expressed as mean (SD) or median, if not otherwise specified
SD, standard deviation; PaO2, arterial oxygen partial pressure; PaCO2, arterial carbon dioxide partial pressure; Tsq, subcutaneous tissue temperature; Skin temperature gradient, forearm-fingertip skin temperature; VAS, visual analog scale; PONV, postoperative nausea and vomiting; CI, confidence interval
For statistical comparisons, a random effects GLS regression model was used
Difference between study groups if not otherwise defined
§Odds ratio
*p < 0.05

Discussion

Obesity, defined as a BMI ≥ 30 kg/m2, is a major determinant of perioperative tissue oxygenation. Subcutaneous tissue and wound hypoxia are common in obese patients during the perioperative period [14]. Even with supplemental oxygen, tissue oxygen tension is reduced to partial pressures, which are associated with a substantial increase in surgical site infections [12].
In this study, overall subcutaneous tissue oxygen tension increased significantly in obese patients undergoing laparoscopic surgery receiving Doppler-guided fluid administration. While no difference was observed intraoperatively, the effect of intervention resulted in raised tissue oxygenation in the early postoperative period. Our findings are in accordance with a recently published paper showing that subcutaneous tissue oxygen tension was high and well maintained in lean, overweight, and obese patients undergoing Doppler-guided fluid management during open gynecological surgery [23]. However, the previously published study did not include a representative control group and thus no direct comparison with patients receiving conventional fluid treatment was possible. This must be deemed a major limitation of this study. Additionally, obese patients had an average BMI of 33 kg/m2, which is far below the BMI range of the typical patient who is referred to weight loss surgery. The study presented here adds further weight to the evidence, as morbidly obese patients undergoing bariatric surgery with an average BMI of approximately 45 kg/m2 were included and randomly assigned to a treatment group and a conventional group.
We have previously shown that subcutaneous tissue oxygenation in obese patients undergoing laparoscopic surgery was reduced by roughly 15 mmHg compared to non-obese patients [15], which is comparable to our observed difference of 13 mmHg between both groups. However, in the abovementioned trial, patients received a fixed and rather low maintenance dose of fluid instead of an individualized guided fluid regimen. Thus, the absolute volumes administered were substantially lower when compared to our study. Our administered total volumes of fluid did not differ between the two groups. This is in accordance with recent evidence that BMI, at least in a lower range, does not determine fluid requirements [23]. There is evidence that the exact timing of bolus administration is a crucial factor and has more impact than the actual amount or type of fluid administered [13, 24, 25].
Laparoscopic case volumes have increased over time; especially in obese patients with an increased risk of wound healing complications, laparoscopic interventions represent state-of-the-art techniques. However, tissue oxygen tension is decreased during laparoscopic colonic surgery compared to open surgery [26]. Duration of surgery was considerably longer and arterial oxygen partial pressures were maintained at a lower level compared to our study. Thus, indirect comparisons between both studies are not feasible. During pneumoperitoneum, systemic vascular resistance is increased, which in turn decreases cardiac output [27].
Interestingly, our observed improvement of tissue oxygen tension in obese patients assigned to the goal-directed group was not reflected by systemic hemodynamics, which remained unchanged between both groups. One may argue that goal-directed volume optimization has a more pronounced effect during open abdominal procedures. So far, only a few studies have focused on the coherence between optimized global hemodynamics and microcirculation during perioperative GDFT [28, 29]. In a heterogeneous intensive care population, microvascular flow index improved independently of changes in stroke volume after fluid challenge [30]. This indicates that timely fluid administration enhances impaired microcirculation, i.e., peripheral blood flow and thus oxygen delivery to peripheral tissues independently of microcirculation.
Given the cardiovascular peculiarities of obese patients, the assumption of hemodynamic coherence, in the specific setting of pneumoperitoneum, remains questionable. Alongside macro- and microcirculation, arterial oxygenation constitutes a major determinate of tissue oxygen availability [31]. One strength of our study is that intraoperative arterial partial pressures were comparable and well controlled in both groups. The benefit of intraoperative individualized GDFT in terms of postoperative morbidity is well established [32]. So far, only a few studies have evaluated GDFT protocols in bariatric patients. In general, treatment algorithms based on dynamic preload parameters such as stroke volume variation or pleth variability index and their effect on fluid requirements and postoperative renal function have been evaluated [33, 34]. Stroke volume optimization according to arterial pressure waveform analysis decreased the incidence of postoperative nausea and vomiting and shortened length of hospital stay [35]. As far as we are aware, we have shown for the first time the feasibility of esophageal Doppler monitoring in this specific setting; except for approximately two measurements during placement of the calibration bougie for gastric pouch sizing, we were able to obtain stable Doppler signals over the time period. Compared to dynamic preload parameters, esophageal Doppler monitoring is not influenced by tidal volume and increased abdominal pressure, and might therefore provide more reliability during the specific condition of pneumoperitoneum.
The use of vasopressors and subsequent vasoconstriction is an important confounding factor for tissue oxygen tension. However, phenylephrine use in our study was comparable in both arms and had no effect on tissue oxygen tension.
A limitation is that we did not measure gut or wound tissue oxygen tension but instead evaluated PsqO2 from a needle-induced surrogate wound in the upper arm. This represents the classical method of measuring tissue oxygenation and has been validated and used in numerous previous studies [22]. The benefit of this location is that measurements can be conducted easily during surgery. Microscopic tissue injury to subcutaneous tissues at the sensor insertion site in the upper arm is not only inevitable, but is indeed a deliberate feature of this model, which is designed to mimic surgical trauma [36].
All our patients were relatively healthy; obese patients were predominately female and procedures were short. The beneficial effect of guided stroke volume optimization might be more obvious in patients with cardiovascular compromise, in male patients with a higher degree of central obesity and during longer procedures with more extended fluid shifts. We did not expect any long-lasting effects of our fluid regimen, which was restricted to the intraoperative period. Thus, we only measured tissue oxygen tension during a short period of time in the immediate postoperative period. The first hours after surgical trauma are considered to represent a decisive period for the establishment of surgical site infection and are thus of major interest [37].

Conclusion

Regardless of similar systemic hemodynamics and comparable fluid requirements, goal-directed fluid therapy improved subcutaneous tissue oxygen partial pressure in the early postoperative period in obese patients undergoing laparoscopic bariatric surgery. To enhance peripheral perfusion and thus tissue oxygen availability, the timely administration of fluid boluses according to patients’ needs might be more important than the total amount of fluid. Given the laparoscopic approach and the short duration of surgery, our findings might have more impact in patients undergoing open abdominal surgery associated with significant fluid shifts.

Compliance with Ethical Standards

Conflict of Interest

The authors declare that they have no conflict of interest.

Ethics Approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Informed consent was obtained from all individual participants included in the study.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
1.
Zurück zum Zitat Collaboration NCDRF. Trends in adult body-mass index in 200 countries from 1975 to 2014: a pooled analysis of 1698 population-based measurement studies with 19.2 million participants. Lancet. 2016;387:1377–96.CrossRef Collaboration NCDRF. Trends in adult body-mass index in 200 countries from 1975 to 2014: a pooled analysis of 1698 population-based measurement studies with 19.2 million participants. Lancet. 2016;387:1377–96.CrossRef
2.
Zurück zum Zitat Heymsfield SB, Wadden TA. Mechanisms, pathophysiology, and management of obesity. N Engl J Med. 2017;376:254–66.CrossRef Heymsfield SB, Wadden TA. Mechanisms, pathophysiology, and management of obesity. N Engl J Med. 2017;376:254–66.CrossRef
3.
Zurück zum Zitat Adams JP, Murphy PG. Obesity in anaesthesia and intensive care. Br J Anaesth. 2000;85:91–108.CrossRef Adams JP, Murphy PG. Obesity in anaesthesia and intensive care. Br J Anaesth. 2000;85:91–108.CrossRef
4.
Zurück zum Zitat Bellamy MC, Margarson MP. Designing intelligent anesthesia for a changing patient demographic: a consensus statement to provide guidance for specialist and non-specialist anesthetists written by members of and endorsed by the Society for Obesity and Bariatric Anaesthesia (SOBA). Perioper Med (Lond). 2013;2:12.CrossRef Bellamy MC, Margarson MP. Designing intelligent anesthesia for a changing patient demographic: a consensus statement to provide guidance for specialist and non-specialist anesthetists written by members of and endorsed by the Society for Obesity and Bariatric Anaesthesia (SOBA). Perioper Med (Lond). 2013;2:12.CrossRef
5.
Zurück zum Zitat Members of the Working P, Nightingale CE, Margarson MP, et al. Peri-operative management of the obese surgical patient 2015: Association of Anaesthetists of Great Britain and Ireland Society for Obesity and Bariatric Anaesthesia. Anaesthesia. 2015;70:859–76.CrossRef Members of the Working P, Nightingale CE, Margarson MP, et al. Peri-operative management of the obese surgical patient 2015: Association of Anaesthetists of Great Britain and Ireland Society for Obesity and Bariatric Anaesthesia. Anaesthesia. 2015;70:859–76.CrossRef
6.
Zurück zum Zitat Ingrande J, Brodsky JB. Intraoperative fluid management and bariatric surgery. Int Anesthesiol Clin. 2013;51:80–9.CrossRef Ingrande J, Brodsky JB. Intraoperative fluid management and bariatric surgery. Int Anesthesiol Clin. 2013;51:80–9.CrossRef
7.
Zurück zum Zitat Alpert MA. Obesity cardiomyopathy: pathophysiology and evolution of the clinical syndrome. Am J Med Sci. 2001;321:225–36.CrossRef Alpert MA. Obesity cardiomyopathy: pathophysiology and evolution of the clinical syndrome. Am J Med Sci. 2001;321:225–36.CrossRef
8.
Zurück zum Zitat Feldschuh J, Enson Y. Prediction of the normal blood volume. Relation of blood volume to body habitus. Circulation. 1977;56:605–12.CrossRef Feldschuh J, Enson Y. Prediction of the normal blood volume. Relation of blood volume to body habitus. Circulation. 1977;56:605–12.CrossRef
9.
Zurück zum Zitat Lemmens HJ, Bernstein DP, Brodsky JB. Estimating blood volume in obese and morbidly obese patients. Obes Surg. 2006;16:773–6.CrossRef Lemmens HJ, Bernstein DP, Brodsky JB. Estimating blood volume in obese and morbidly obese patients. Obes Surg. 2006;16:773–6.CrossRef
10.
Zurück zum Zitat Di Girolamo M, Skinner Jr NS, Hanley HG, et al. Relationship of adipose tissue blood flow to fat cell size and number. Am J Phys. 1971;220:932–7.CrossRef Di Girolamo M, Skinner Jr NS, Hanley HG, et al. Relationship of adipose tissue blood flow to fat cell size and number. Am J Phys. 1971;220:932–7.CrossRef
11.
Zurück zum Zitat Shoemaker WC, Appel PL, Kram HB. Role of oxygen debt in the development of organ failure sepsis, and death in high-risk surgical patients. Chest. 1992;102:208–15.CrossRef Shoemaker WC, Appel PL, Kram HB. Role of oxygen debt in the development of organ failure sepsis, and death in high-risk surgical patients. Chest. 1992;102:208–15.CrossRef
12.
Zurück zum Zitat Hopf HW, Hunt TK, West JM, et al. Wound tissue oxygen tension predicts the risk of wound infection in surgical patients. Arch Surg. 1997;132:997–1004. discussion 5CrossRef Hopf HW, Hunt TK, West JM, et al. Wound tissue oxygen tension predicts the risk of wound infection in surgical patients. Arch Surg. 1997;132:997–1004. discussion 5CrossRef
13.
Zurück zum Zitat Reiterer C, Kabon B, Zotti O, et al. Effect of goal-directed crystalloid- versus colloid-based fluid strategy on tissue oxygen tension: a randomised controlled trial. Br J Anaesth. 2019;123:768–76.CrossRef Reiterer C, Kabon B, Zotti O, et al. Effect of goal-directed crystalloid- versus colloid-based fluid strategy on tissue oxygen tension: a randomised controlled trial. Br J Anaesth. 2019;123:768–76.CrossRef
14.
Zurück zum Zitat Kabon B, Nagele A, Reddy D, et al. Obesity decreases perioperative tissue oxygenation. Anesthesiology. 2004;100:274–80.CrossRef Kabon B, Nagele A, Reddy D, et al. Obesity decreases perioperative tissue oxygenation. Anesthesiology. 2004;100:274–80.CrossRef
15.
Zurück zum Zitat Fleischmann E, Kurz A, Niedermayr M, et al. Tissue oxygenation in obese and non-obese patients during laparoscopy. Obes Surg. 2005;15:813–9.CrossRef Fleischmann E, Kurz A, Niedermayr M, et al. Tissue oxygenation in obese and non-obese patients during laparoscopy. Obes Surg. 2005;15:813–9.CrossRef
16.
Zurück zum Zitat Pasarica M, Sereda OR, Redman LM, et al. Reduced adipose tissue oxygenation in human obesity: evidence for rarefaction, macrophage chemotaxis, and inflammation without an angiogenic response. Diabetes. 2009;58:718–25.CrossRef Pasarica M, Sereda OR, Redman LM, et al. Reduced adipose tissue oxygenation in human obesity: evidence for rarefaction, macrophage chemotaxis, and inflammation without an angiogenic response. Diabetes. 2009;58:718–25.CrossRef
17.
Zurück zum Zitat Thorp AA, Schlaich MP. Relevance of sympathetic nervous system activation in obesity and metabolic syndrome. J Diabetes Res. 2015;2015:341583.CrossRef Thorp AA, Schlaich MP. Relevance of sympathetic nervous system activation in obesity and metabolic syndrome. J Diabetes Res. 2015;2015:341583.CrossRef
18.
Zurück zum Zitat Moher D, Hopewell S, Schulz KF, et al. CONSORT 2010 explanation and elaboration: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c869.CrossRef Moher D, Hopewell S, Schulz KF, et al. CONSORT 2010 explanation and elaboration: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c869.CrossRef
19.
Zurück zum Zitat Robinson JD, Lupkiewicz SM, Palenik L, et al. Determination of ideal body weight for drug dosage calculations. Am J Hosp Pharm. 1983;40:1016–9.PubMed Robinson JD, Lupkiewicz SM, Palenik L, et al. Determination of ideal body weight for drug dosage calculations. Am J Hosp Pharm. 1983;40:1016–9.PubMed
20.
Zurück zum Zitat Waldron NH, Miller TE, Thacker JK, et al. A prospective comparison of a noninvasive cardiac output monitor versus esophageal Doppler monitor for goal-directed fluid therapy in colorectal surgery patients. Anesth Analg. 2014;118:966–75.CrossRef Waldron NH, Miller TE, Thacker JK, et al. A prospective comparison of a noninvasive cardiac output monitor versus esophageal Doppler monitor for goal-directed fluid therapy in colorectal surgery patients. Anesth Analg. 2014;118:966–75.CrossRef
21.
Zurück zum Zitat Rubinstein EH, Sessler DI. Skin-surface temperature gradients correlate with fingertip blood flow in humans. Anesthesiology. 1990;73:541–5.CrossRef Rubinstein EH, Sessler DI. Skin-surface temperature gradients correlate with fingertip blood flow in humans. Anesthesiology. 1990;73:541–5.CrossRef
22.
Zurück zum Zitat Hopf HW, Hunt TK, Scheuenstuhl H, et al. Measuring oxygen in wounds. Methods Enzymol. 2004;381:539–64.CrossRef Hopf HW, Hunt TK, Scheuenstuhl H, et al. Measuring oxygen in wounds. Methods Enzymol. 2004;381:539–64.CrossRef
23.
Zurück zum Zitat Holzer A, Sitter B, Kimberger O, et al. Body mass index does not affect intraoperative goal-directed fluid requirements. Minerva Anestesiol. 2019;85:1071–9.CrossRef Holzer A, Sitter B, Kimberger O, et al. Body mass index does not affect intraoperative goal-directed fluid requirements. Minerva Anestesiol. 2019;85:1071–9.CrossRef
24.
Zurück zum Zitat Noblett SE, Snowden CP, Shenton BK, et al. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg. 2006;93:1069–76.CrossRef Noblett SE, Snowden CP, Shenton BK, et al. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg. 2006;93:1069–76.CrossRef
25.
Zurück zum Zitat Jhanji S, Vivian-Smith A, Lucena-Amaro S, et al. Haemodynamic optimisation improves tissue microvascular flow and oxygenation after major surgery: a randomised controlled trial. Crit Care. 2010;14:R151.CrossRef Jhanji S, Vivian-Smith A, Lucena-Amaro S, et al. Haemodynamic optimisation improves tissue microvascular flow and oxygenation after major surgery: a randomised controlled trial. Crit Care. 2010;14:R151.CrossRef
26.
Zurück zum Zitat Fleischmann E, Kugener A, Kabon B, et al. Laparoscopic surgery impairs tissue oxygen tension more than open surgery. Br J Surg. 2007;94:362–8.CrossRef Fleischmann E, Kugener A, Kabon B, et al. Laparoscopic surgery impairs tissue oxygen tension more than open surgery. Br J Surg. 2007;94:362–8.CrossRef
27.
Zurück zum Zitat Atkinson TM, Giraud GD, Togioka BM, et al. Cardiovascular and ventilatory consequences of laparoscopic surgery. Circulation. 2017;135:700–10.CrossRef Atkinson TM, Giraud GD, Togioka BM, et al. Cardiovascular and ventilatory consequences of laparoscopic surgery. Circulation. 2017;135:700–10.CrossRef
28.
Zurück zum Zitat Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg. 1995;130:423–9.CrossRef Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg. 1995;130:423–9.CrossRef
29.
Zurück zum Zitat Kimberger O, Arnberger M, Brandt S, et al. Goal-directed colloid administration improves the microcirculation of healthy and perianastomotic colon. Anesthesiology. 2009;110:496–504.CrossRef Kimberger O, Arnberger M, Brandt S, et al. Goal-directed colloid administration improves the microcirculation of healthy and perianastomotic colon. Anesthesiology. 2009;110:496–504.CrossRef
30.
Zurück zum Zitat Pranskunas A, Koopmans M, Koetsier PM, et al. Microcirculatory blood flow as a tool to select ICU patients eligible for fluid therapy. Intensive Care Med. 2013;39:612–9.CrossRef Pranskunas A, Koopmans M, Koetsier PM, et al. Microcirculatory blood flow as a tool to select ICU patients eligible for fluid therapy. Intensive Care Med. 2013;39:612–9.CrossRef
31.
Zurück zum Zitat De Santis V, Singer M. Tissue oxygen tension monitoring of organ perfusion: rationale, methodologies, and literature review. Br J Anaesth. 2015;115:357–65.CrossRef De Santis V, Singer M. Tissue oxygen tension monitoring of organ perfusion: rationale, methodologies, and literature review. Br J Anaesth. 2015;115:357–65.CrossRef
32.
Zurück zum Zitat Sun Y, Chai F, Pan C, et al. Effect of perioperative goal-directed hemodynamic therapy on postoperative recovery following major abdominal surgery-a systematic review and meta-analysis of randomized controlled trials. Crit Care. 2017;21:141.CrossRef Sun Y, Chai F, Pan C, et al. Effect of perioperative goal-directed hemodynamic therapy on postoperative recovery following major abdominal surgery-a systematic review and meta-analysis of randomized controlled trials. Crit Care. 2017;21:141.CrossRef
33.
Zurück zum Zitat Jain AK, Dutta A. Stroke volume variation as a guide to fluid administration in morbidly obese patients undergoing laparoscopic bariatric surgery. Obes Surg. 2010;20:709–15.CrossRef Jain AK, Dutta A. Stroke volume variation as a guide to fluid administration in morbidly obese patients undergoing laparoscopic bariatric surgery. Obes Surg. 2010;20:709–15.CrossRef
34.
Zurück zum Zitat Demirel I, Bolat E, Altun AY, et al. Efficacy of goal-directed fluid therapy via pleth variability index during laparoscopic Roux-en-Y gastric bypass surgery in morbidly obese patients. Obes Surg. 2018;28:358–63.CrossRef Demirel I, Bolat E, Altun AY, et al. Efficacy of goal-directed fluid therapy via pleth variability index during laparoscopic Roux-en-Y gastric bypass surgery in morbidly obese patients. Obes Surg. 2018;28:358–63.CrossRef
35.
Zurück zum Zitat Munoz JL, Gabaldon T, Miranda E, et al. Goal-directed fluid therapy on laparoscopic sleeve gastrectomy in morbidly obese patients. Obes Surg. 2016;26:2648–53.CrossRef Munoz JL, Gabaldon T, Miranda E, et al. Goal-directed fluid therapy on laparoscopic sleeve gastrectomy in morbidly obese patients. Obes Surg. 2016;26:2648–53.CrossRef
36.
Zurück zum Zitat Goodson 3rd WH, Hunt TK. Development of a new miniature method for the study of wound healing in human subjects. J Surg Res. 1982;33:394–401.CrossRef Goodson 3rd WH, Hunt TK. Development of a new miniature method for the study of wound healing in human subjects. J Surg Res. 1982;33:394–401.CrossRef
37.
Zurück zum Zitat Miles AA, Miles EM, Burke J. The value and duration of defence reactions of the skin to the primary lodgement of bacteria. Br J Exp Pathol. 1957;38:79–96.PubMedPubMedCentral Miles AA, Miles EM, Burke J. The value and duration of defence reactions of the skin to the primary lodgement of bacteria. Br J Exp Pathol. 1957;38:79–96.PubMedPubMedCentral
Metadaten
Titel
Effect of Intraoperative Goal-Directed Fluid Management on Tissue Oxygen Tension in Obese Patients: a Randomized Controlled Trial
Publikationsdatum
27.11.2020
Erschienen in
Obesity Surgery / Ausgabe 3/2021
Print ISSN: 0960-8923
Elektronische ISSN: 1708-0428
DOI
https://doi.org/10.1007/s11695-020-05106-x

Weitere Artikel der Ausgabe 3/2021

Obesity Surgery 3/2021 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.