Skip to main content
Erschienen in: Health and Quality of Life Outcomes 1/2016

Open Access 01.12.2016 | Research

Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials

verfasst von: Chi-Wen Kao, Miao-Yi Chen, Ting-Yu Chen, Pai-Hui Lin

Erschienen in: Health and Quality of Life Outcomes | Ausgabe 1/2016

Abstract

Background

Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients’ mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs.

Methods

We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration’s Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I 2 statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling.

Results

Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p < 0.001), but did not significantly affect mental component summary (MCS) scores (mean difference 0.84, 95 % CI -1.68 to 3.35, p = 0.52).

Conclusion

Our meta-analysis demonstrates that psycho-educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.
Abkürzungen
CBT
Cognitive behavioral therapy
CI
Confidence interval
ICD
Implantable cardioverter defibrillator
MCS
Mental component summary score
MeSH
Medical Subject Heading
NYHA
New York heart association
PCS
Physical component summary score
PRISMA
Preferred Reporting Items for Systematic Reviews and Meta-Analysis
QOL
Quality of life
SF-36
36-Item Short Form Health Survey
WHO
World Health Organization

Background

Implantable cardioverter defibrillator (ICD) has been established as an efficient treatment for primary and secondary prevention of sudden cardiac death [14]. Thus, the number of ICD implantations worldwide is growing exponentially every year. In the United States, the ICD implantation rate increased from 6.1 % in 1993 to 46.2 % in 2006, with the average rate significantly increasing 17.9 % per year (95 % confidence interval [CI]: 17.6-18.3 %, p < 0.001) [5]. In Australia, the number of ICD implantations nationwide increased from 708 in 2000 to 3198 in 2009, with the implantation rate significantly increasing 19.2 % per year (p < 0.001) [6].
Once the device is implanted, patients face various ICD-related changes that affect their quality of life (QOL). For example, patients with ICDs in a systematic review of qualitative studies were found to experience changes that were both physical (e.g., discomfort, sleep disturbance, fatigue) and psychological (e.g., fear of shocks from the ICD, uncertainty about the future, worry about ICD function), which negatively affected their daily activities and QOL [7]. Several other factors related to worse QOL have been identified in patients with ICDs, such as worry about the duration and number of shocks [711], uncertainty in daily life [12], anxiety [9, 13, 14], feeling loss of control in life [7, 9], ICD-related concerns [10], lower level of device-related acceptance [13], depression [14, 15], high comorbidity burden [16], Type D personality [17], and negative attitudes toward technology dependency [18]. A significant proportion of ICD recipients experience psychological distress. Indeed, 11–28 % of ICD patients were diagnosed as depressed [1921], and furthermore a systematic review of 45 studies indicated that 5–41 % of ICD patients had elevated depressive symptoms when assessed by self-report instruments [22]. In the same systematic review with more than 5000 ICD recipients, 11–26 % of patients were diagnosed with anxiety disorders [22]. Thus, healthcare providers should be concerned not only with how long patients live (their quantity of life) with an ICD, but also their QOL.
Drawing overall conclusions about the effect of an ICD on QOL is difficult because of inconsistent results reported [23]. For example, ICD recipients in a systematic review of studies from 1994 to 2006 had better QOL than patients treated with antiarrhythmic medication, but worse than that of the general public or patients with pacemakers [18]. On the other hand, a more recent study found varying results in 80 ICD recipients: 44.7, 20.7, and 34.2 % had no change in QOL, worse QOL, and better QOL, respectively, after implantation [9]. Furthermore, a study conducted in Hong Kong showed that the 85 ICD recipients in this study had a lower level of QOL compared with the general population [13]. In contrast, QOL (SF-36 scores) of 300 patients with ICDs was improved in all domains during the 1-year follow-up, except for the emotional role functioning domain [24].
Quality of life is an important outcome for patients with ICDs since it predicts survival in the first year after implantation [25]. Moreover, the psychological aspects of QOL were cited by the American Heart Association as desirable outcomes of psychological and educational interventions for ICD patients [26]. The return to normal QOL in ICD patients has been shown to be facilitated by structured follow-up and the development of psycho-educational intervention programs [7, 10, 2729].
During the past decade, various psychological and educational interventions have been designed and provided to ICD patients. Moreover, the effectiveness of these interventions in improving ICD patients’ QOL has been examined in several randomized controlled trials. However, the current evidence for the effectiveness of these trials has not been comprehensively reviewed. Therefore, the aim of this systematic review and meta-analysis was to evaluate the overall effectiveness of psycho-educational interventions on QOL in patients with ICDs.

Methods

This systematic review and meta-analysis was guided by the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guideline [30].

Search strategy

We systematically searched the literature in following databases: Medline, PubMed, Cochrane Library, and CINAHL. The databases were searched from inception to April 2015. Search key words used were “implantable cardioverter defibrillator,” “psychosocial intervention,” “psychological intervention,” “psycho-education intervention,” and “quality of life.” We also used Medical Subject Headings (MeSH) to identify the terminology of key words. To find additional studies and data, we hand searched the references of relevant publications and contacted the authors.

Study selection criteria

Studies were eligible for review if they met following criteria: (1) a randomized controlled trial, (2) subjects were adult patients with ICDs, (3) a psycho-educational intervention was administered, (4) QOL was measured using the SF-36 or SF-12, and (5) written in English or Chinese.
We selected SF-36 or SF-12 scores as the outcome indicator for QOL to preserve sufficient homogeneity for meta-analysis because these instruments have good properties and are the most widely used to measure QOL in studies on the ICD population internationally [8]. SF-36 or SF-12 scores are calculated and aggregated into two summary scores, a mental component summary score (MCS), and a physical component summary score (PCS) [31, 32].

Quality assessment

The methodological quality of each trial was independently evaluated by two reviewers (CWK and TYC) using a quality-assessment scale. [33]. This Jadad scale includes 11 items: (1) Was the study designed as randomized? (2) Was the study designed as double blind? (3) Was there a description of withdrawals and drop outs? (4) Were the objects of the study defined? (5) Were the outcome measures defined clearly? (6) Was there a clear description of the inclusion and exclusion criteria? (7) Was the sample size justified? (8) Was there a clear description of the interventions? (9) Was there at least one control group? (10) Was the method used to assess adverse effects described? (11) Were the methods of statistical analysis described? The maximum possible score was 13, and more than nine points was identified as good. Any disagreements in the quality evaluation between two reviewers were resolved by discussion.

Data extraction

Each selected article was examined to abstract the following data: title of study, authors, publication year, sample size (number of participants in the experimental and control groups), participants’ age and sex, intervention details (type, course, duration, and follow-up), type of control, and the SF-36 or SF-12 score at less than 6 months post-intervention. To assure the accuracy of data extraction, two reviewers abstracted data independently, and discussed any inconsistencies to reach consensus.

Data analysis and synthesis

The meta-analysis was conducted using RevMan 5.3 (Cochrane Collaboration) software. SF-36 or SF-12 scores are continuous data, which were analyzed as mean differences and 95 % CIs. The statistical heterogeneity among trials was measured by Q statistics and I2. Higher values of I2 indicate greater heterogeneity, with I2 values of 25, 50, and 75 % signifying mild, moderate, and high heterogeneity, respectively [34, 35]. Depending on the heterogeneity findings, data were pooled to estimate the overall effect of all interventions by random-effect or fixed-effect modeling. Publication bias was assessed using the funnel plot method, whose asymmetrical shape shows bias [36].

Results

Characteristics of trials

The flow diagram for the study selection process is presented in Fig. 1. Of the 151 articles retrieved from our initial search, we reviewed abstracts and removed 35 duplicate articles and 88 articles that were inconsistent with the aim of the meta-analysis. Among the remaining 28 full-length articles, we excluded 17 studies that did not meet the inclusion criteria. Among the remaining 11 studies, four were not included. One study did not provide the mean and standard deviation of SF-36 scores even after we contacted the authors [37], one study had high dropout rates in each group [38], and two studies [39, 40] analyzed the long-term follow-up outcome of one randomized controlled trial, but we already included the post-intervention outcomes of this trial in our analysis. Therefore, the final data analysis included seven studies [4147] (Table 1).
Table 1
Characteristics of included RCTs
First author, year [ref]
No. of participants (I/C)
Mean age (years)
Mean EF
Intervention
Course
QoL Measure
Measure Time
Berg et al. 2014 [41]
99/97
57.15
32.44 %
Comprehensive cardiac rehabilitation
 
SF-36
Baseline, 3 m, 6 m, 12 m
Exercise training; twice a week
12w
Psycho-education; once/month for 6 months, and every 2 months for the next 6 months
12 m
Habibovic et al. 2014 [42]
146/143
55.9
≤ 35 % (63.7 % of patients)
Online problem-solving course based on CBT principles
12w
SF-12
Baseline, 3 m, 6 m, 12 m
Irvine et al. 2011 [43]
94/91
64.39
≤ 35 % (19.7 % of patients)
CBT in eight telephone sessions, psycho-educational book, CD with meditation exercises, muscle relaxation
8w
SF-36
Baseline, 6 m, 12 m
Crössmann et al. 2010 [44]
63/56
60.71
No report
Psychological treatment by phone call
6 m
SF-36
Baseline, 6 m
Kuhl et al. 2009 [45]
15/15
57.44
≤ 35 % (78.2 % of patients)
PACER-CD-ROM-based on psycho-educational CBT
4w
SF-12
Baseline, 1 m
Sears et al. 2007 [46]
15/15
59.77
No report
Components of ICD Shock and Stress Management Program
6w
SF-12
Baseline, 2 m, 4 m
ICD-specific education
Relaxation/stress management training
Cognitive-behavioral techniques
Group discussion and social support
Dougherty et al. 2004 [47]
84/84
64.04
33.78 %
Nursing telephone support
8w
SF-12
Baseline, 1 m, 3 m
ICD recovery management
Enhance self-confidence
Reduce emotional distress
Structure information provided
I intervention, C control, EF ejection fraction, QoL quality of life, w weeks, m months, CBT cognitive-behavioral therapy
These seven studies included 1017 ICD recipients as participants, with 516 randomly assigned to the experimental group, and 501 to the control group. The majority of participants were male (80.4 %, n = 818), with mean age across the studies ranging from 55.9 to 64.4 years, and mean ejection fraction lower than 35 % in five studies [4143, 45, 47] and not reported in two studies [44, 46]. QOL outcomes were measured in four studies with the SF-12 [42, 4547], and in three studies using the SF-36 [41, 43, 44].
Table 2 presents the quality assessment of the reviewed studies according to the 11-item Jadad Scale. Five studies had Jadad scores ≥ 9 points, indicating good quality [33]. Two studies had Jadad scores of eight points because they did not meet four of the 11 criteria: double blind, description of dropouts, sample size justified, and report of adverse effects.
Table 2
Quality assessment of the included RCTs
References
randomized
double blind
description of drop outs
objects defined
outcome measures defined
Inclusion/ exclusion criteria
sample size justified
description of the interventions
control group
adverse effects
statistical analysis
Jadad Score
Berg et al. [41]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
13
Irvine et al. [43]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
13
Habibovic et al. [42]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
12
Crössmann et al. [44]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
12
Dougherty et al. [47]
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
9
Kuhl et al. [45]
Yes
No
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
8
Sears et al. [46]
Yes
No
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
8

Effect of psycho-educational intervention on QOL

The effect of psycho-educational interventions on QOL was examined by separately considering the effects on PCS and MCS, respectively. For the intervention effect on PCS, we used fixed-effect modeling since no heterogeneity was detected among trials (χ2 = 2.51, p = 0.87; I2 = 0 %). The mean difference in PCS scores between experimental and control groups in all seven studies was estimated as 2.08 (95 % CI 0.86 to 3.29, p < 0.001). This result indicates that the psycho-educational interventions significantly improved the physical component of QOL in patients with ICDs (Fig. 2).
For the intervention effect on MCS, we used random-effect modeling since heterogeneity was identified among trials (χ 2 = 21.33, p = 0.002; I2 = 72 %). The mean difference in MCS scores between the experimental and control groups was estimated as 0.84 (95 % CI -1.68 to 3.35, p = 0.52), indicating that the psycho-educational interventions were not effective in improving the mental component of QOL in patients with ICDs (Fig. 3). Since ICD patients’ anxiety and depressive symptoms have been suggested to respond to cognitive behavioral therapy (CBT), we conducted a subgroup analysis of three randomized control trials that used CBT approaches in their interventions [43, 45, 46] to determine if these interventions were effective for the mental component of QOL. The effectiveness of these studies in improving MCS was assessed using random-effect modeling since heterogeneity was identified among trials (χ2 = 10.64, p = 0.005; I2 = 81 %). The mean difference in MCS scores between the experimental and control groups was 3.29 (95 % CI -3.16 to 9.73, p = 0.32). The result revealed that using the CBT approach in the psycho-educational interventions for ICD patients was still not significantly effective in improving their mental component of QOL.
As two studies had Jadad scores of 8 points, we eliminated these two studies and conducted a meta-analysis of five randomized controlled trials [4144, 47]. The psycho-educational interventions still significantly improved the physical component of QOL (95 % CI 0.65 to 3.19, p = 0.003), but not the mental component of QOL (95 % CI -3.46 to 1.47, p = 0.43) in patients with ICDs.

Publication bias

Our funnel plot assessment of PCS and MCS showed no evidence of asymmetry, indicating the absence of publication bias.

Discussion

Our systematic review and meta-analysis of seven randomized controlled trials on 1017 ICD patients provides evidence that psycho-educational interventions effectively improve the physical component but not the mental component of patients’ QOL. Although the majority of recipients regard the ICD as a life-saving medical device that offers them a new chance in life [24, 48], they are affected physically and emotionally by adjustments to the ICD [7]. The psycho-education interventions in the seven reviewed studies were designed to improve recipients’ physical capacity, self-management of ICD-specific care, and self-perceived health [4147]. The psycho-education interventions included exercise training, psycho-education, problem-solving, ICD-specific education and recovery management, as well as relaxation training. ICD recipients in the experimental groups received more information and strategies to deal with life changes related to ICD implantation, which may have improved their perceived health. Finally, the findings of this meta-analysis indicate that the psycho-educational interventions effectively and significantly improved the physical component of ICD recipients’ QOL (PCS).
Most of the psycho-educational interventions in the seven randomized controlled trials we analyzed aimed to deal with ICD patients’ documented psychological distress and improve their QOL [4147]. However, our meta-analysis did not detect any effectiveness of these psycho-educational interventions in improving the mental component of QOL. This lack of effect may have been due to the psycho-educational interventions not adequately addressing psychological distress. We also conducted the subgroup analysis of three randomized control trials which used CBT in their interventions [43, 45, 46] to determine whether CBT was effective for the mental component of QOL since ICD patients’ anxiety and depressive symptoms have been suggested to respond to CBT [44, 49]. One study provided CBT in eight telephone consultations with supporting literature [43], another study provided CBT with a patient-assisted computerized intervention program [45], and the third study provided CBT in the context of a 6-week or 1-day ICD shock-and-stress management program [46]. However, the finding cannot support a statistically significant effectiveness.
This lack of effect may have been due to low statistical power of the studies. Among these three studies, two had relatively small samples, with only 15 participants in each group [45, 46]. Another contributing factor may have been limitations of the SF-36, which is a generic measurement to assess health status and QOL. Even though the SF-36 is commonly used in ICD population studies, it may not detect ICD-specific QOL outcomes, especially mental health well-being [16]. Indeed, the mental health subscale of the SF-36 was reported to be less sensitive to changes in mental health than the WHO-Five Well-Being Scale [50]. In addition, MCS scoring assigns positive weights to four domains (vitality, social functioning, role-emotional, and emotional well-being) and negative weights to four other domains (physical functioning, role-physical, bodily pain, and general health). [51]. The ICD patients recruited in these seven studies had poor health due to their heart condition. Most of them had a heart failure history in NYHA class III or IV, and left ventricular ejection fraction < 35 % [4147]. Therefore, their responses to questions on the negatively weighted last four domains may have driven down their MCS scores.
Among participants in these seven studies, those in five studies experienced ICD shocks [41, 43, 44, 46, 47], those in one study were reported not to experience any ICD shock during the study [45], and the ICD shock experiences of those in another study were not reported [42]. Most people living with an ICD have to cope with stressful or even traumatic events, including having ICD shocks [52]. ICD shocks can be appropriate or inappropriate (not related to therapeutic outcomes), and all ICD shocks adversely affect patients’ mental health [53]. In one qualitative study, ICD patients described their reactions to receiving a shock as losing consciousness, feeling anxious, fearing death and pain, despairing, and worrying about the device not working effectively [37]. Even worse, patients’ psychological distress was greater due to fear of shocks than to actual shocks [54]. In our meta-analysis, we did not detect any effectiveness of psycho-educational interventions on improving the mental component of ICD patients’ QOL (MCS).

Limitations

The strengths of our study are that it is, to the best of our knowledge, the first meta-analysis of randomized control trials on the effects of psycho-educational interventions on QOL in ICD recipients, the meta-analysis followed the PRISMA guidelines, and we avoided publication bias by hand searching retrieved articles for other studies and tried to contact researchers to ask for unpublished data.
However, this meta-analysis had some limitations. The studies included in the meta-analysis were diverse, with different psycho-educational interventions. To address this issue, we analyzed studies for heterogeneity and, based on these findings, used fixed- or random-effect modeling to pool the data to determine an overall intervention effect. We only included studies published in English or Chinese, which may have introduced publication bias. Finally, only seven studies qualified for inclusion in our meta-analysis, six of which had relatively small samples (<100 participants). Therefore, even though psycho-educational interventions in the original studies [41, 43, 4547] reported improvements in psychological distress, e.g., depression and anxiety, we did not find that the pooled data from the psycho-educational interventions improved the mental component of QOL (MCS) in ICD recipients.

Conclusions

The findings of this meta-analysis provide evidence that psycho-educational interventions improved the physical component of QOL (PCS), but not the mental component of QOL (MCS) in patients with ICDs. Nonetheless, we recommend that healthcare providers should still consider the psycho-social adaptation issues of ICD recipients. Identifying effective psycho-educational interventions for improving QOL in ICD recipients will require conducting large-scale randomized clinical trials. Further long-term evaluation follow-up may be needed to examine the durable effectiveness of psycho-educational interventions in patients with ICDs.

Acknowledgements

We are grateful to the authors who responded to our emails and provided additional information about their studies.

Funding

Not applicable.

Availability of data and material

The data will not be shared because we do not have the raw data. This manuscript reported results of a meta-analysis, which we extracted the data for meta-analysis from published papers.

Authors’ contributions

CWK, MYC, and PHL conducted the systematical search, and data extraction. CWK, MYC, and TYC analyzed the data. CWK and TYC evaluated the quality of each study. CWK wrote the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.
Not applicable.
Not applicable.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Ezekowitz JA, Armstrong PW, McAlister FA. Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials. Ann Intern Med. 2003;138:445–52.CrossRefPubMed Ezekowitz JA, Armstrong PW, McAlister FA. Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials. Ann Intern Med. 2003;138:445–52.CrossRefPubMed
2.
Zurück zum Zitat Bokhari F, Newman D, Greene M, et al. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS). Circulation. 2004;110:112–6.CrossRefPubMed Bokhari F, Newman D, Greene M, et al. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS). Circulation. 2004;110:112–6.CrossRefPubMed
3.
Zurück zum Zitat Greenberg H, Case RB, Moss AJ, et al. Analysis of mortality events in the Multicenter Automatic Defibrillator Implantation Trial (MADIT-II). J Am Coll Cardiol. 2004;43:1459–65.CrossRefPubMed Greenberg H, Case RB, Moss AJ, et al. Analysis of mortality events in the Multicenter Automatic Defibrillator Implantation Trial (MADIT-II). J Am Coll Cardiol. 2004;43:1459–65.CrossRefPubMed
4.
Zurück zum Zitat Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter defibrillator for congestive heart failure. N Engl J Med. 2005;352:225–37.CrossRefPubMed Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter defibrillator for congestive heart failure. N Engl J Med. 2005;352:225–37.CrossRefPubMed
5.
Zurück zum Zitat Kurtz SM, Ochoa JA, Lau E, et al. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillator in the United States: 1993–2006. PACE. 2010;33:705–11.CrossRefPubMed Kurtz SM, Ochoa JA, Lau E, et al. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillator in the United States: 1993–2006. PACE. 2010;33:705–11.CrossRefPubMed
6.
Zurück zum Zitat Burch AWT, Wong CX, Sullivan T, et al. Trends in the use of implantable cardioverter defibrillators in Australia: a 10-year nationwide study from 2000-2009. Intern Med J. 2013;43:888–95.CrossRefPubMed Burch AWT, Wong CX, Sullivan T, et al. Trends in the use of implantable cardioverter defibrillators in Australia: a 10-year nationwide study from 2000-2009. Intern Med J. 2013;43:888–95.CrossRefPubMed
7.
Zurück zum Zitat Palacios-Ceña D, Losa-Iglesias ME, Álvarez-López C, et al. Patients, intimate partners and family experiences of implantable cardioverter defibrillators: qualitative systematic review. J Adv Nurs. 2011;67:2537–50.CrossRefPubMed Palacios-Ceña D, Losa-Iglesias ME, Álvarez-López C, et al. Patients, intimate partners and family experiences of implantable cardioverter defibrillators: qualitative systematic review. J Adv Nurs. 2011;67:2537–50.CrossRefPubMed
8.
Zurück zum Zitat Francis J, Johnson B, Niehaus M. Quality of life in patients with implantable cardioverter defibrillators. Indian Pacing Electrophysiol J. 2006;6:173–81.PubMedPubMedCentral Francis J, Johnson B, Niehaus M. Quality of life in patients with implantable cardioverter defibrillators. Indian Pacing Electrophysiol J. 2006;6:173–81.PubMedPubMedCentral
9.
Zurück zum Zitat Dickerson SS, Kennedy M, Wu YWB, Underhill M, Othman A. Factors related to quality-of-life pattern changes in recipients of implantable defibrillators. Heart Lung. 2010;39:466–76.CrossRefPubMed Dickerson SS, Kennedy M, Wu YWB, Underhill M, Othman A. Factors related to quality-of-life pattern changes in recipients of implantable defibrillators. Heart Lung. 2010;39:466–76.CrossRefPubMed
10.
Zurück zum Zitat Thylén I, Dekker RL, Jaarsma T, Strömberg A, Moser DK. Characteristics associated with anxiety, depressive symptoms, and quality-of-life in a large cohort of implantable cardioverter defibrillator recipients. J Psychosom Res. 2014;77:122–7.CrossRefPubMed Thylén I, Dekker RL, Jaarsma T, Strömberg A, Moser DK. Characteristics associated with anxiety, depressive symptoms, and quality-of-life in a large cohort of implantable cardioverter defibrillator recipients. J Psychosom Res. 2014;77:122–7.CrossRefPubMed
11.
Zurück zum Zitat Mark DB, Anstrom KJ, Sun JL, et al. Quality of life with defibrillator therapy or amiodarone in heart failure. N Engl J Med. 2008;359:999–1008.CrossRefPubMedPubMedCentral Mark DB, Anstrom KJ, Sun JL, et al. Quality of life with defibrillator therapy or amiodarone in heart failure. N Engl J Med. 2008;359:999–1008.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Flemme I, Hallberg U, Johansson I, Strömberg A. Uncertainty is a major concern for patients with implantable cardioverter defibrillators. Heart Lung. 2011;40:420–8.CrossRefPubMed Flemme I, Hallberg U, Johansson I, Strömberg A. Uncertainty is a major concern for patients with implantable cardioverter defibrillators. Heart Lung. 2011;40:420–8.CrossRefPubMed
13.
Zurück zum Zitat Chair SY, Lee CK, Choi KC, Sears SF. Quality of life outcomes in Chinese patients with implantable cardioverter defibrillators. PACE. 2011;34:858–67.CrossRefPubMed Chair SY, Lee CK, Choi KC, Sears SF. Quality of life outcomes in Chinese patients with implantable cardioverter defibrillators. PACE. 2011;34:858–67.CrossRefPubMed
14.
Zurück zum Zitat Wheeler EC, Pretzer-Aboff I, Hardie T, DiSabatino A, Saylor J, Lucey R. Psychological impact of implantable cardioverter defibrillator on their patients. Dimens Crit Care. 2009;28:176–81.CrossRef Wheeler EC, Pretzer-Aboff I, Hardie T, DiSabatino A, Saylor J, Lucey R. Psychological impact of implantable cardioverter defibrillator on their patients. Dimens Crit Care. 2009;28:176–81.CrossRef
15.
Zurück zum Zitat Hallas CN, Burke JL, White DG, Connelly DT. A prospective 1-year study of changes in neuropsychological functioning after implantable cardioverter- defibrillator surgery. Circ Arrhythm Electrophysiol. 2010;3:170–7.CrossRefPubMed Hallas CN, Burke JL, White DG, Connelly DT. A prospective 1-year study of changes in neuropsychological functioning after implantable cardioverter- defibrillator surgery. Circ Arrhythm Electrophysiol. 2010;3:170–7.CrossRefPubMed
16.
Zurück zum Zitat Hoogwegt MT, Kupper N, Jordaens L, Pedersen SS, Theuns DAMJ. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator. Europace. 2013;15:1468–74.CrossRefPubMed Hoogwegt MT, Kupper N, Jordaens L, Pedersen SS, Theuns DAMJ. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator. Europace. 2013;15:1468–74.CrossRefPubMed
17.
Zurück zum Zitat Habibovic M, van den Broek KC, Theuns DAMJ, et al. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator. Europace. 2011;13:1723–30.CrossRefPubMed Habibovic M, van den Broek KC, Theuns DAMJ, et al. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator. Europace. 2011;13:1723–30.CrossRefPubMed
18.
Zurück zum Zitat Udlis KA. The impact of technology dependency on device acceptance and quality of life in persons with implantable cardioverter defibrillators. J Cardiovasc Nurs. 2013;28:E65–73.CrossRefPubMed Udlis KA. The impact of technology dependency on device acceptance and quality of life in persons with implantable cardioverter defibrillators. J Cardiovasc Nurs. 2013;28:E65–73.CrossRefPubMed
19.
Zurück zum Zitat Crow SM, Collins J, Justic M, Goetz R, Adler S. Psychopathology following cardioverter defibrillator implantation. Psychosomatics. 1998;39:305–10.CrossRefPubMed Crow SM, Collins J, Justic M, Goetz R, Adler S. Psychopathology following cardioverter defibrillator implantation. Psychosomatics. 1998;39:305–10.CrossRefPubMed
20.
Zurück zum Zitat Godemann F, Butter C, Lampe F, Linden M, et al. Panic disorders and agoraphobia: Side effects of treatment with an implantable cardioverter defibrillator. Clin Cardiol. 2004;27:321–6.CrossRefPubMed Godemann F, Butter C, Lampe F, Linden M, et al. Panic disorders and agoraphobia: Side effects of treatment with an implantable cardioverter defibrillator. Clin Cardiol. 2004;27:321–6.CrossRefPubMed
21.
Zurück zum Zitat Jacq F, Foulldrin G, Savoure A, Anselme F, et al. A comparison of anxiety, depression and quality of life between device shock and nonshock groups in implantable cardioverter defibrillator recipients. Gen Hosp Psychiatry. 2009;31:266–73.CrossRefPubMed Jacq F, Foulldrin G, Savoure A, Anselme F, et al. A comparison of anxiety, depression and quality of life between device shock and nonshock groups in implantable cardioverter defibrillator recipients. Gen Hosp Psychiatry. 2009;31:266–73.CrossRefPubMed
22.
Zurück zum Zitat Magyar-Russell G, Thombs BD, Cai JX, et al. The prevalence of anxiety and depression in adults with implantable cardioverter defibrillators: a systematic review. J Psychosom Res. 2011;71:223–31.CrossRefPubMed Magyar-Russell G, Thombs BD, Cai JX, et al. The prevalence of anxiety and depression in adults with implantable cardioverter defibrillators: a systematic review. J Psychosom Res. 2011;71:223–31.CrossRefPubMed
23.
Zurück zum Zitat Groeneveld PW, Matta MA, Suh JJ, Heidenreich PA, Shea JA. Costs and quality-of-life effects of implantable cardioverter-defibrillators. Am J Cardiol. 2006;98:1409–15.CrossRefPubMed Groeneveld PW, Matta MA, Suh JJ, Heidenreich PA, Shea JA. Costs and quality-of-life effects of implantable cardioverter-defibrillators. Am J Cardiol. 2006;98:1409–15.CrossRefPubMed
24.
Zurück zum Zitat Starrenburg A, Pedersen S, van den Broek K, Karrier K, Scholten M, van der Palen J. Gender differences in psychological distress and quality of life in patients with ICD 1-year postimplant. PACE. 2014;37:843–52.CrossRefPubMed Starrenburg A, Pedersen S, van den Broek K, Karrier K, Scholten M, van der Palen J. Gender differences in psychological distress and quality of life in patients with ICD 1-year postimplant. PACE. 2014;37:843–52.CrossRefPubMed
25.
Zurück zum Zitat Kao CW, Friedmann E, Thomas SA. Quality of life predicts one-year survival in patients with implantable cardioverter defibrillators. Qual Life Res. 2010;19:307–15.CrossRefPubMed Kao CW, Friedmann E, Thomas SA. Quality of life predicts one-year survival in patients with implantable cardioverter defibrillators. Qual Life Res. 2010;19:307–15.CrossRefPubMed
26.
Zurück zum Zitat Dunbar SB, Dougherty CM, Sears SF, et al. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association. Circulation. 2012;126:2146–72.CrossRefPubMed Dunbar SB, Dougherty CM, Sears SF, et al. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association. Circulation. 2012;126:2146–72.CrossRefPubMed
27.
Zurück zum Zitat Bostwick JM, Sola CL. An updated review of implantable cardioverter defibrillators induced anxiety, and quality of life. Heart Failure Clin. 2011;7:101–8.CrossRef Bostwick JM, Sola CL. An updated review of implantable cardioverter defibrillators induced anxiety, and quality of life. Heart Failure Clin. 2011;7:101–8.CrossRef
28.
Zurück zum Zitat Wilson MH, Engelke MK, Sears SF, Swanson M, Neil JA. Disease-specific quality of life-patient acceptance. J Cardiovasc Nurs. 2013;28:285–93.CrossRefPubMed Wilson MH, Engelke MK, Sears SF, Swanson M, Neil JA. Disease-specific quality of life-patient acceptance. J Cardiovasc Nurs. 2013;28:285–93.CrossRefPubMed
29.
Zurück zum Zitat Cesarino CB, Beccaria LM, Aroni MM, Rodrigues LCC, Pacheco SS. Quality of life of patients with implantable cardioverter-defibrillator: the usage of SF-36 questionnaire. Rev Bras Cir Cardiovasc. 2011;26:238–43.PubMed Cesarino CB, Beccaria LM, Aroni MM, Rodrigues LCC, Pacheco SS. Quality of life of patients with implantable cardioverter-defibrillator: the usage of SF-36 questionnaire. Rev Bras Cir Cardiovasc. 2011;26:238–43.PubMed
30.
Zurück zum Zitat Moher D, Shamseer L, Clarke M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. System Rev. 2015;4:1–9.CrossRef Moher D, Shamseer L, Clarke M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. System Rev. 2015;4:1–9.CrossRef
32.
Zurück zum Zitat Ware JE, Kosinski M. Physical & mental health summary scales: a manual for users of version 1. 2nd ed. RI: QualityMetric Incorporated; 2001. Ware JE, Kosinski M. Physical & mental health summary scales: a manual for users of version 1. 2nd ed. RI: QualityMetric Incorporated; 2001.
33.
Zurück zum Zitat Jadad R, Moore RA, Carrol D, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17:1–12.CrossRefPubMed Jadad R, Moore RA, Carrol D, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17:1–12.CrossRefPubMed
34.
Zurück zum Zitat Higgins JP, Thompson SG, Deeks JJ, Altman DG. Statistical heterogeneity in systematic reviews of clinical trials: a critical appraisal of guideline and practice. J Health Serv Res Policy. 2002;7:51–61.CrossRefPubMed Higgins JP, Thompson SG, Deeks JJ, Altman DG. Statistical heterogeneity in systematic reviews of clinical trials: a critical appraisal of guideline and practice. J Health Serv Res Policy. 2002;7:51–61.CrossRefPubMed
35.
Zurück zum Zitat Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. Br Med J. 2003;327:557–60.CrossRef Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. Br Med J. 2003;327:557–60.CrossRef
36.
Zurück zum Zitat Littell JH, Corcoran J, Pillai V. Systematic reviews and meta-analysis. New York: Oxford University Press; 2008.CrossRef Littell JH, Corcoran J, Pillai V. Systematic reviews and meta-analysis. New York: Oxford University Press; 2008.CrossRef
37.
Zurück zum Zitat Cinar FI, Tosun N, Kose S. Evaluation of an education and follow-up programme for implantable cardioverter defibrillator-implanted patients. J Clin Nurs. 2013;22:2474–86.CrossRefPubMed Cinar FI, Tosun N, Kose S. Evaluation of an education and follow-up programme for implantable cardioverter defibrillator-implanted patients. J Clin Nurs. 2013;22:2474–86.CrossRefPubMed
38.
Zurück zum Zitat Lewin RJ, Coulton S, Frizelle DJ, Kaye G, Cox H. A brief cognitive behavioral preimplantation and rehabilitation programme for patients receiving an implantable cardioverter-defibrillator improves physical health and reduces psychological morbidity and unplanned readmissions. Heart. 2009;95:63–9.CrossRefPubMed Lewin RJ, Coulton S, Frizelle DJ, Kaye G, Cox H. A brief cognitive behavioral preimplantation and rehabilitation programme for patients receiving an implantable cardioverter-defibrillator improves physical health and reduces psychological morbidity and unplanned readmissions. Heart. 2009;95:63–9.CrossRefPubMed
39.
Zurück zum Zitat Dougherty CM, Thompson EA, Lewis FM. Long-term outcomes of a telephone intervention after an ICD. PACE. 2005;28:1157–67.CrossRefPubMed Dougherty CM, Thompson EA, Lewis FM. Long-term outcomes of a telephone intervention after an ICD. PACE. 2005;28:1157–67.CrossRefPubMed
40.
Zurück zum Zitat Christensen AV, Zwisler AD, Svendsen JH, et al. Effect of cardiac rehabilitation in patients with ICD: Are gender differences present? Results from the COPE-ICD trial. PACE. 2015;38:18–27.CrossRefPubMed Christensen AV, Zwisler AD, Svendsen JH, et al. Effect of cardiac rehabilitation in patients with ICD: Are gender differences present? Results from the COPE-ICD trial. PACE. 2015;38:18–27.CrossRefPubMed
41.
Zurück zum Zitat Berg SK, Pedersen PU, Zwisler AD, et al. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator: findings from the COPE-ICD randomized clinical trial. Eur J Cardiovasc Nurs. 2014;14:34–44. Berg SK, Pedersen PU, Zwisler AD, et al. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator: findings from the COPE-ICD randomized clinical trial. Eur J Cardiovasc Nurs. 2014;14:34–44.
42.
Zurück zum Zitat Habibovic M, Denollet J, Coupers P, et al. E-health to manage distress in patients with an implantable cardioverter-defibrillator: primary results of the WEBCARE trial. Psychosom Med. 2014;76:593–602.CrossRefPubMed Habibovic M, Denollet J, Coupers P, et al. E-health to manage distress in patients with an implantable cardioverter-defibrillator: primary results of the WEBCARE trial. Psychosom Med. 2014;76:593–602.CrossRefPubMed
43.
Zurück zum Zitat Irvine J, Firestone J, Ong L, et al. A randomized controlled trial of cognitive behavior therapy tailored to psychological adaptation to an implantable cardioverter defibrillator. Psychosom Med. 2011;73:226–33.CrossRefPubMed Irvine J, Firestone J, Ong L, et al. A randomized controlled trial of cognitive behavior therapy tailored to psychological adaptation to an implantable cardioverter defibrillator. Psychosom Med. 2011;73:226–33.CrossRefPubMed
44.
Zurück zum Zitat Crössmann A, Schulz SM, Kühlkamp V, et al. A randomized controlled trial of secondary prevention of anxiety and distress in a German sample of patients with implantable cardioverter defibrillator. Psychosom Med. 2010;72:434–41.CrossRefPubMed Crössmann A, Schulz SM, Kühlkamp V, et al. A randomized controlled trial of secondary prevention of anxiety and distress in a German sample of patients with implantable cardioverter defibrillator. Psychosom Med. 2010;72:434–41.CrossRefPubMed
45.
Zurück zum Zitat Kuhl EA, Sears SF, Vazquez LD, Conti JB. Patient-assisted computerized education for recipients of implantable cardioverter defibrillators: a randomized controlled trial of the PACER program. J Cardiovasc Nurs. 2009;24:225–31.CrossRefPubMed Kuhl EA, Sears SF, Vazquez LD, Conti JB. Patient-assisted computerized education for recipients of implantable cardioverter defibrillators: a randomized controlled trial of the PACER program. J Cardiovasc Nurs. 2009;24:225–31.CrossRefPubMed
46.
Zurück zum Zitat Sears SF, Sowell LV, Kuhl EA, et al. The ICD shock and stress management program: a randomized trial of psychosocial treatment to optimize quality of life in ICD patients. PACE. 2007;30:858–64.CrossRefPubMed Sears SF, Sowell LV, Kuhl EA, et al. The ICD shock and stress management program: a randomized trial of psychosocial treatment to optimize quality of life in ICD patients. PACE. 2007;30:858–64.CrossRefPubMed
47.
Zurück zum Zitat Dougherty CM, Lewis FM, Thompson EA, Baer JD, Kim W. Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator. PACE. 2004;27:1594–602.CrossRefPubMed Dougherty CM, Lewis FM, Thompson EA, Baer JD, Kim W. Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator. PACE. 2004;27:1594–602.CrossRefPubMed
48.
Zurück zum Zitat Eckert M, Jones T. How does an implantable cardioverter defibrillator affect the lives of patients and their families? Int J Nurs Pract. 2002;8:152–7.CrossRefPubMed Eckert M, Jones T. How does an implantable cardioverter defibrillator affect the lives of patients and their families? Int J Nurs Pract. 2002;8:152–7.CrossRefPubMed
49.
Zurück zum Zitat Spek V, Cuijpers P, Nyklicek I, Riper H, Keyzer J, Pop V. Internet-based cognitive behavior therapy for symptoms of depression and anxiety: a meta-analysis. Psychol Med. 2007;37:319–28. Spek V, Cuijpers P, Nyklicek I, Riper H, Keyzer J, Pop V. Internet-based cognitive behavior therapy for symptoms of depression and anxiety: a meta-analysis. Psychol Med. 2007;37:319–28.
50.
Zurück zum Zitat Bech P, Olsen LR, Kjoller M, Rasmussen NK. Measuring well-being rather than the absence of distress symptoms: a comparison of the SF-36 Mental Health subscale and WHO-Five Well-Being Scale. Int J Methods Psychiatr Res. 2003;12:85–91.CrossRefPubMed Bech P, Olsen LR, Kjoller M, Rasmussen NK. Measuring well-being rather than the absence of distress symptoms: a comparison of the SF-36 Mental Health subscale and WHO-Five Well-Being Scale. Int J Methods Psychiatr Res. 2003;12:85–91.CrossRefPubMed
51.
Zurück zum Zitat Farivar SS, Cunningham WE, Hays RD. Correlated physical and mental health summary scores for the SF-36 and SF-12 health survey, v.1. Health and Quality of Life Outcomes. 2007;5:54-61. Farivar SS, Cunningham WE, Hays RD. Correlated physical and mental health summary scores for the SF-36 and SF-12 health survey, v.1. Health and Quality of Life Outcomes. 2007;5:54-61.
52.
Zurück zum Zitat Ford J, Sears S, Shea JB, Cahill J. Coping with trauma and stressful events as a patient with an implantable cardioverter-defibrillator. Circulation. 2013;127:e426–30.CrossRefPubMed Ford J, Sears S, Shea JB, Cahill J. Coping with trauma and stressful events as a patient with an implantable cardioverter-defibrillator. Circulation. 2013;127:e426–30.CrossRefPubMed
53.
Zurück zum Zitat Borne RT, Varosy PD, Masoudi FA. Implantable cardioverter-defibrillator shocks: epidemiology, outcomes, and therapeutic approaches. JAMA Intern Med. 2013;173:859–65.CrossRefPubMed Borne RT, Varosy PD, Masoudi FA. Implantable cardioverter-defibrillator shocks: epidemiology, outcomes, and therapeutic approaches. JAMA Intern Med. 2013;173:859–65.CrossRefPubMed
54.
Zurück zum Zitat Vazquez LD, Conti JB, Sears SF. Female-specific education, management, and lifestyle enhancement for implantable cardioverter defibrillator patients: the FEMALWE-ICD study. PACE. 2010;33:1131–40.CrossRefPubMed Vazquez LD, Conti JB, Sears SF. Female-specific education, management, and lifestyle enhancement for implantable cardioverter defibrillator patients: the FEMALWE-ICD study. PACE. 2010;33:1131–40.CrossRefPubMed
Metadaten
Titel
Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials
verfasst von
Chi-Wen Kao
Miao-Yi Chen
Ting-Yu Chen
Pai-Hui Lin
Publikationsdatum
01.12.2016
Verlag
BioMed Central
Erschienen in
Health and Quality of Life Outcomes / Ausgabe 1/2016
Elektronische ISSN: 1477-7525
DOI
https://doi.org/10.1186/s12955-016-0543-2

Weitere Artikel der Ausgabe 1/2016

Health and Quality of Life Outcomes 1/2016 Zur Ausgabe